Entryphone 500 Series Quick start guide

DOOR ENTRY SYSTEMS
Entryphone
®
500 Series Video
Schematics, connection diagrams and installer's notes
For the system installed at:
By:

Entryphone®page 3Entryphone®page 2
ImportantContents
Page
Important 3
Schematic and connection diagrams - examples
One line system - looped wiring 4
Three way system - single run wiring 6
Six-way system - two riser looped wiring 8
Ten-way system - two riser looped and single run wiring 10
Panel connections 12
Phone binary codes 14
Installer's notes 15
DIP Switch set to
address no.6
Jumper (J1) on Jumper (J1) off
Entryphone 500 Series equipment is designed to enable video systems to be installed on
standard audio wiring. The video, speech, signalling and power are on ve common conductors
to every part of the system.
There are two very important things that must be done to ensure a system works well.
1. The video signal is balanced and therefore termination jumpers must be inserted at line
ends or removed from mid-line equipment.
Schematics and wiring diagrams show when jumpers should be tted.
NOTE: If, on test, a video screen seems over bright or washed out it is likely that the line
has not been terminated properly, either a jumper is inserted mid-line or missing at the
end of the line.
2. There are no individual call lines for the 500 series systems, instead each phone has a
switch setting that should be set when the telephone is installed.
The phone's address is set as a binary number on an eight way DIL (dual in-line) switch
(up to 255 addresses available) tted in each phone. When planning a system it is good
practice to determine which address is to be assigned to which phone and noted on the
numbering sheet on page 14 of these instructions.
System Layout
Whether installing a system on existing or new wiring it is best to determine the layout of the
cabling and positions of the apparatus before starting the installation. There are a number of
layout examples and their corresponding connection diagrams in this booklet.
Please make a note of the phone codes and sketch the layout of the system on pages 14 and 15
of this booklet. Leave this booklet with the installed system.
Door Release.
Telephones
Multi-button Entrance
Unit.
12345678
03
DIP Switch
Setting
Power Supply
Relay Unit
Jumper Setting
Remote Camera
see pages 4/5 and
12/13
Single button
Entrance
Unit
Extension
Sounder
see pages 4/5
4 Way Splitter
Timeswitch
see pages 6/7

Entryphone®page 5Entryphone®page 4
System Description
One line system - looped wiring
A one-way system with two parallel
phones with wiring looped from
phone to phone.
Second camera: There is an option
to t a second camera to the system.
The camera should be connected
to the 2nd camera terminals on
the door amplier printed circuit
board (see page 12/13) and link J2V
should be inserted. When the J2V
link is inserted the cameras switch
over every two seconds. The camera
button on the phone will switch
between cameras or lock view to
one camera.
Single button panel's call address is
set to 01.
Schematic Connections
GRN/
WHT
1 Video -
WHT/
GRN
2Video +
BLU/
WHT
3Data
WHT/
BLU
424V-
ORG/
WHI
524V+
BRN/
WHT
6 Lock Data +
WHT/
BRN
7 Lock Data -
Key: line function
Se co nd cam er a
12v D C Max 300mA
OU T 2
OU T 1
1D 2D 3D 4 D 5 D 6 D 7 D
n/ o C n/c
R elease
500PSU
Entrance PanelC am 2
12 v 0v
12 v 0v V
12 v 0v V
T E L 1
J1 T E L 31 2 3 4 5
T o 1 2 v D C exter nal
sounder . M ax 200 m A
Sounder term inal om itted from other
telephones show n on this diagram for c larity
1 2 3 4 5 1 2 3 4 5 1 D 2D 3D 4D 5D 6D 7 D
1 2 3 4 5 T E L 2
1 2 3 4 5
J1
J1
J1
R+ R-
J2V
2
7
5
5
5
12345 6 7 8
0 1
2
3
12345 6 7 8
0 1
12345 6 7 8
0 1

Entryphone®page 7Entryphone®page 6
System Description
Three way system - single run wiring
A three-way system with wiring in
single runs from the power supply
to each phone.
Trades time-switch allows access at
preselected times via a button on
the entrance panel.
Note: In this example the link in the
power supply is removed as the
input terminals are mid-line.
Schematic Connections
GRN/
WHT
1 Video -
WHT/
GRN
2Video +
BLU/
WHT
3Data
WHT/
BLU
424V-
ORG/
WHI
524V+
BRN/
WHT
6 Lock Data +
WHT/
BRN
7 Lock Data -
Key: line function
2
9
5
5
5
12345 6 7 8
0 1
12345 6 7 8
0 2
12345 6 7 8
0 3
3
T im e sw it c h
OU T 2OU T 1
1D 2D 3D 4D 5 D 6 D 7 D
n/ o C n/c
R elease
D A5 00 P SU
Entrance Panel
12 v 0v
T E L 1
1 2 3 4 5 1 D 2 D 3D 4D 5D 6D 7D
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5 1 2 3 4 5
J1 J1
Link
R em o ve d
T E L 2 T E L 3
J1
J1
N C N O C O + -

Entryphone®page 9Entryphone®page 8
2
5
5
5
5
4
5
12345 6 7 8
0 1
12345 6 7 8
0 3
12345 6 7 8
05
1234567 8
0 2
1234567 8
0 4
1234567 8
06
5
5
OU T 2OU T 1
1 D 2 D 3 D 4D 5D 6D 7D
1 D 2 D 3 D 4D 5D 6D 7D
n/o C n/c
R elease
1 2 3 4 5 1 2 3 4 5
OU T 1 OU T 2 OU T 3 OU T 4
1 2 3 4 5
IN
500VS 4 S plitter
24 v 0 v
12 v 0v
1 2 3 4 5 1 2 3 4 5
J1
J1
J1
T E L
J1
1 2 3 4 5
T E L
1 2 3 4 5
J1 1 2 3 4 5
T E L
1 2 3 4 5 J1
T E L
J1
1 2 3 4 5
T E L
1 2 3 4 5
J1 1 2 3 4 5
T E L
1 2 3 4 5
Entrance unit
500LSV
Power Supply
500PSU
Schematic Connections
System Description
Six-way system - two riser looped
wiring
A six-way system with wiring in two
legs from a splitter to three loop
wired phones. Jumpers are removed
in mid-line apparatus.
Note: In this example the power
supply is in a dierent location to
the splitter. If they were in the same
place no splitter would be required.
GRN/
WHT
1 Video -
WHT/
GRN
2Video +
BLU/
WHT
3Data
WHT/
BLU
424V-
ORG/
WHI
524V+
BRN/
WHT
6 Lock Data +
WHT/
BRN
7 Lock Data -
Key: line function

Entryphone®page 11Entryphone®page 10
5
5
5
5
5
7
5
55
5
5
2
5
5
OU T 2OU T 1
1 D 2 D 3 D 4D 5D 6D 7D
1 D 2 D 3 D 4D 5D 6D 7D
n/o C n/c
R elease
1 2 3 4 5
OU T 1 OU T 2 OU T 3 OU T 4
1 2 3 4 5
IN
500VS 4 Splitter
24 v 0 v
12 v 0v
1 2 3 4 5 1 2 3 4 5
J1
J1
T E L
J1
T E L
1 2 3 4 5
J1 1 2 3 4 5
T E L
1 2 3 4 5 J1
T E L
J1
1 2 3 4 5
T E L
1 2 3 4 5
J1 1 2 3 4 5
T E L
1 2 3 4 5
Entrance unit
500LSV
Power Supply
500PSU
OU T 1 OU T 2 OU T 3 OU T 4IN
500VS 4 Splitter
24 v 0 v
J1
J1 1 2 3 4 5
T E L
1 2 3 4 5
J1 1 2 3 4 5
T E L
1 2 3 4 5
J1 1 2 3 4 5
T E L
J1 1 2 3 4 5
T E L
1 2 3 4 51 2 3 4 5
1 2 3 4 5
J1
1 2 3 4 5
1 2 3 4 5
Schematic Connections
System Description
Ten-way system - two riser looped
and single run wiring
A ten-way system with wiring
in two legs from one splitter to
three loop wired phones on two
outputs and a second splitter
with a single phone on each of
the four outputs.
Note: In this example the power
supply is in a dierent location
to the splitters. If the rst splitter
were in the same place it would
not be required.
Jumpers are removed in mid-
line apparatus - note the power
supply in this example is mid-line
and the jumper is removed.
GRN/
WHT
1 Video -
WHT/
GRN
2Video +
BLU/
WHT
3Data
WHT/
BLU
424V-
ORG/
WHI
524V+
BRN/
WHT
6 Lock Data +
WHT/
BRN
7 Lock Data -
Key: line function

Entryphone®page 13Entryphone®page 12
Panel connections
500 series entrance panels are
supplied with the 500LSV loud-
speaking amplier assembly
tted and the call buttons are
pre-wired. It is not necessary
for the installer to change the
button wiring. The call but-
tons are connected using a 7x7
matrix conguration which
is detailed here. Rather than
change the panel button wir-
ing an installer should consider
changing the phone address.
Button matrix
output pins
(see gs.1&2)
2nd Camera
input
(see g.7)
Camera angle
adjustment gimbal
assembly
Button back
lighting voltage
(see g.3)
Panel camera
input
(see g.6) Mic connector
(see g.5)
Speaker
connector
(see g.4)
2nd Camera
Jumper - J2V
inter-equipment
connector
Call buttons
CPB
(common bell push)
back-lighting
connection
(see g.3)
Mic sensitivity
Speaker volume
Lock release
time
Fig.1
Matrix connection to buttons
1- 11 shown
1234567 8
0 2
1234567 8
0 3
1234567 8
0 4
1234567 8
0 5
1234567 8
0 6
1234567 8
0 7
1234567 8
0 8
1234567 8
0 9
12345 6 7 8
1 0
1234567 8
11
1234567 8
0 1
Fig.6
Panel camera
+ -
V
Fig.5
Microphone
+ -
Fig.4
Speaker
+ -
Fig.3
Back-lighting
(note wired in series)
Fig.7
2nd Camera
12 V0
Fig.2
Matrix connection numbers 1-49
41
2
3
4
5
6
7
8
9
10
11
12
13
14
5
6
7
8
9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
3
2
1
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49

Entryphone®page 15Entryphone®page 14
Phone binary codes Installer's notes
1234567 8
1234567 8
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
1234567 8
1234567 8
1234567 8
1234567 8
1234567 8
12345 6 7 8
12345 6 7 8
1234567 8
12345 6 7 8
12345 6 7 8
12345 6 7 8
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
12345 6 7 8
12345 6 7 8
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
12345 6 7 8
12345 6 7 8
12345 6 7 8
12345 6 7 8
12345 6 7 8
12345 6 7 8
12345 6 7 8
12345 6 7 8
12345 6 7 8
12345 6 7 8
12345 6 7 8
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
12345 6 7 8
12345 6 7 8
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
12345 6 7 8
12345 6 7 8
1234567 8
1234567 8
1234567 8
12345 6 7 8
1234567 8
1234567 8
12345 6 7 8
12345 6 7 8
12345 6 7 8
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
It is good practice to decide the layout of the system and the allocation of phone codes
before starting an installation. Use the list below to indicate which code is assigned
to which phone. Bear in mind the positions of the number or names on the entrance
panel.
To work out the decimal value of the binary code add the decimal
values of each switch together. This example shows switches 2
(binary value 2), 4 (binary value 8) & 5 (binary value 16) down.
Therefore 2+8+16 = 26.
12345 6 7 8
26
16
32
64
128
8
4
2
1
Binary Value

The Entryphone Company Limited,
23 Granville Road,
London, SW18 5SD
t: 020 8870 8635 f: 020 8874 0066
e: enquiries@entryphone.co.uk w: www.entryphone.co.uk
®ENTRYPHONE is a trade mark registered in Britain No. B1037141.
Other manuals for 500 Series
1
This manual suits for next models
2
Other Entryphone Intercom System manuals