  7. Intercom System
  8. •
  9. Entryphone CA8 Instruction manual

Entryphone CA8 Instruction manual

A2BA1LPF1G2
+-ED
- +
LH11LAMP
~~
12v
0+-
ACDC
Nameillumination
+12vDC-
DOORRELEASE
A2BA1LPF1G2
TELEPHONE
POWERSUPPLY
TELEPHONE
ENTRANCEPANEL
PWR
PWR
RTE2
NC
C
0V
NC
C
NO
NO
CODEDACCESSCA8
TAMP
TAMP
RTE1
0V
REL2REL1
NO
C
NC
N/O
C
N/C
~~
RELAY(GPRU)
BREAKGLASS
1 2
MAGLOCK
+
-
PSU
RTE
SYSTEM
RELEASEPAIR
PWR
PWR
RTE2
NC
C
0V
NC
C
NO
NO
CODEDACCESSCA8
TAMP
TAMP
RTE1
0V
REL2 REL1
buttons
5
3
1
2
4
Entryphone
CA8
Coded Access Unit
Programming instructions
and connection guide
The Entryphone Co Ltd
entryphone.co.uk
020 8870 8635
Connection examples Connection notes
Example connection showing CA8 with Entryphone audio system
A2BA1LPF1G2
+-ED
- +
LH11LAMP
~~
12v
0+-
ACDC
Nameillumination
+12vDC-
DOORRELEASE
A2BA1LPF1G2
TELEPHONE
POWERSUPPLY
TELEPHONE
ENTRANCEPANEL
PWR
PWR
RTE2
NC
C
0V
NC
C
NO
NO
CODEDACCESSCA8
TAMP
TAMP
RTE1
0V
REL2REL1
NO
C
NC
N/O
C
N/C
~~
RELAY(GPRU)
BREAKGLASS
1 2
MAGLOCK
+
-
PSU
RTE
SYSTEM
RELEASEPAIR
PWR
PWR
RTE2
NC
C
0V
NC
C
NO
NO
CODEDACCESSCA8
TAMP
TAMP
RTE1
0V
REL2 REL1
buttons
Example connection showing CA8 with maglock
1. Connection to power
Connect 12-24V AC or DC (polarity insensitive)
2. Relay volt-free switch contacts
Max switching current 6amp at 28V
NC (normally closed)
C (common)
NO (normally open).
3. Master code by-pass pins
Short pins together for more than 2 seconds to enter
programming mode without using the master code
4. RTE (request-to-exit)
Connect switch between RTE and 0V
5. Tamper contacts and micro-switch.
The micro-switch contacts on board close when the back
plate is in place. The contact terminals can be used to
trigger an alarm. Rating 6V DC @ 0.1 A.
Note: there is no alarm circuitry on the CA8.
To enter programming mode (default master code 0000):
press
Error code: If at any time you make an error the unit will
ash and beep 5 times. If this happens the unit will return to
the start and expect you to re-key the sequence.
To change the master code, for example to 8951 (up to 8 digits allowed)
LED status Sound
To leave programming mode:
press
To leave programming mode press
repeat to conrm
press
press
To add code to relay 1 , for example to 5623 (up to 8 digits allowed)
repeat to conrm
To add code to relay 2 , for example to 4455 (up to 8 digits allowed)
repeat to conrm
To add code to both relay 1 and 2, for example to 2589 (up to 8 digits allowed)
press
press
press
press
press
press
press
repeat to conrm
To delete a code, for example to 5623
repeat to conrm
repeat to conrm
To change relay 1 time, for example to 4 seconds (range 0-20, 0=toggle mode)
To change relay 2 time, for example to 12 seconds (range 0-20, 0=toggle mode)
To turn keypad tones o
or on
To change the unit settings you must be in programming mode. The yellow LED
indicates the unit is in programming mode; if it is not on you cannot change any settings.
To return unit to factory defaults (be careful, all codes will be deleted)
The Entryphone CA8 is a coded access unit that can be
supplied as a stand-alone unit or incorporated, to special
order, into an Entryphone entrance unit.
Features include:
• 1-8 digit access codes
• Master code to programme the unit
• Up to 32 access codes, each operating either or both relays
• Two 6 amp relays with change-over contacts
• Anti-hack 30 second lock-out after 5 incorrect codes
• Non-volatile memory in case of power failure
• Condence LED and beep (selectable)
• Back-lit keypad
• Relay output times 1-20 seconds and toggle mode
• Tamper-switch
• Input Supply 12/24 V AC or DC
• Power Consumption 7mA min. / 250mA max
• Operating temperature -20°C to + 50°C
Unit operation:
A user operates the unit by entering a valid programmed code
followed by the star key. Depending on the set up for that code
the unit will operate either or both the relays for the length of
time set for that output. Refer to the programming instructions
to set the parameters.
Code Input Relay 1 Relay 2 Beep
Validate
Error:
If you key a wrong code, the unit will ash
and beep ve times.
Five invalid entries will cause the keypad to ash and for the
unit to stop accepting further attempts for 30 seconds.
No. Name Code R1 R2
M Master 0000
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Programming record list
Please complete and keep in a safe place. Please remember to
change the master code from its default of 0000.
Programming Instructions

Other Entryphone Intercom System manuals

Entryphone 500 Series Quick start guide

Entryphone

Entryphone 500 Series Quick start guide

Entryphone 500 Series Quick start guide

Entryphone

Entryphone 500 Series Quick start guide

Popular Intercom System manuals by other brands

Vimar ELVOX 8000 Series instruction sheet

Vimar

Vimar ELVOX 8000 Series instruction sheet

Protect ERA Installation and operating manual

Protect

Protect ERA Installation and operating manual

Elvox Giotto 6329/C Installer's guide

Elvox

Elvox Giotto 6329/C Installer's guide

NuTone LA227WH quick start guide

NuTone

NuTone LA227WH quick start guide

Radio Active Designs UV-1G user manual

Radio Active Designs

Radio Active Designs UV-1G user manual

Aiphone IXG System Operation manual

Aiphone

Aiphone IXG System Operation manual

GE SmartCom Door Station installation instructions

GE

GE SmartCom Door Station installation instructions

SSS Siedle CLASSIC installation instructions

SSS Siedle

SSS Siedle CLASSIC installation instructions

FARFISA INTERCOMS Exhito Series quick start guide

FARFISA INTERCOMS

FARFISA INTERCOMS Exhito Series quick start guide

2N 9154100 installation manual

2N

2N 9154100 installation manual

Bellcome Touch Line VPA.1FR03.BLB04 user manual

Bellcome

Bellcome Touch Line VPA.1FR03.BLB04 user manual

Carus Adapto CAI2210 Product information

Carus

Carus Adapto CAI2210 Product information

ACTOP VDP311 user manual

ACTOP

ACTOP VDP311 user manual

DAITEM SC901AU installation manual

DAITEM

DAITEM SC901AU installation manual

SSS Siedle SE 600-0 Product information

SSS Siedle

SSS Siedle SE 600-0 Product information

Yale VISUALS 7 quick start guide

Yale

Yale VISUALS 7 quick start guide

Digitus Biometrics dbNEXII user manual

Digitus Biometrics

Digitus Biometrics dbNEXII user manual

nedis WIFICDP10xx quick start guide

nedis

nedis WIFICDP10xx quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.