Envair Lab ecoChem Installation and operation manual

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
OPERATING & MAINTENANCE
MANUAL
EcoChem
Recirculating Fume Cupboard

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
CONTENTS
1. GENERAL 3
2. INSTALLATION 5
2A. INSTRUCTIONS AND CHECKS ON DELIVERY 5
2B. INSTALLATION REQUIREMENTS 5
2C. ELECTRICAL/GAS CONNECTION 6
2D. POSITIONING OF THE CABINET ON THE SUPPORTING TABLE 6
3. OPERATION PRINCIPLES 8
4. OPERATION 9
4A. SCOPE 9
4B. SYSTEM AND PERFORMANCE CONTROLS 9
4C. REMOTE SIGNALS (OPTIONAL AVAIBLE FOR ECOCHEM M)
10
4D. SYMBOLS OF CONTROL BOARD
11
4E. OPERATOR MENU (ONLY FOR ECOCHEM M) 14
5. HOUR COUNTER / UV TIMER (ECOCHEM S) 18
5A. Hours counter 18
5B. Energy save 18
5C. DISPOSAL OF WASTES AND CONTAMINATED MATERIALS 19
5D. ERGONOMICS 19
6. LIMITATIONS 20
7. OPERATING PROCEDURES 21
7A. GENERAL OPERATING INSTRUCTIONS 21
7B. FUME CUPBOARD SWITCHING ON 21
7C. FUME CUPBOARD SWITCHING OFF 21
8. MAINTENANCE 23
8A. INSTRUCTIONS FOR SIX-MONTH CLEANING (By The User) 23
8B. CONTROL AND MONITORING PROCEDURES 23
8C. PREFILTER REPLACEMENT (by the user) 25
8D. ACTIVATED CHARCOAL FILTER REPLACEMENT (By The User) 25
8E. FLUORESCENT LAMPS REPLACEMENT (by the user) 25
8F. MOTOR FAN REPLACEMENT (by the technical assistance staff) 26
8G. GAS SENSOR REPLACEMENT (for Elite-vesion if installed - by the technical assistance staff) 26
9. SPARE PARTS LIST 27
10. ACTIVATED CHARCOAL FILTERS AND PREFILTERS LIST 29
11. TROUBLESHOOTING 32
12. TRANSPORT, PACKING, STORAGE INSTRUCTIONS 33
13. ADDITIONAL INFORMATION 35
13A.GUARANTEE 35
13B.MAINTENANCE SERVICE ADDRESS 35
14. DRAWINGS AND DIAGRAMS 36
14A.MAINTENANCE OPERATIONS DIAGRAM 37

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
14B.FRONT DIAGRAM 38
14C.SIDE DIAGRAM 39
15. ASSEMBLY DIAGRAM FOR SUPPORT TABLE 40
16. SENSORS LIST 43
17. WIRING DIAGRAMS 44
18. DECLARATION OF CONFORMITY 46

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
1. GENERAL
The fume cupboards operating with molecular filtration system ECOCHEM are designed to meet all safety
requirements of operator and environment whenever vapours, aerosols and chemicals are used in the
routine work in laboratories.
They must not be used when large quantities of solvents are evaporated, in acid digestion procedures or
when working with unknown chemicals.
Especially suitable for applications such as:
- Chemicals handling
- Practice in schools
- Cytology
- Hematology/Pathology
- Sterilization of endoscopes
- Ria test
- Manipulation of radioactive labelled compounds
- Assembly of medical devices
The performances of the cabinets are detailed in the TESTING CERTIFICATE below, in compliance with the
requirements of:
- BS 7258-1: Laboratory Fume Cupboards Part 1: Specification for safety and performance
The fume cupboards ECOCHEM fulfil the harmonized standards EN 61010-1 as well as EN 61326 according to
the applicable European directives regarding the CE marking.
The fume cupboards ECOCHEM comply with the above-mentioned Directives ONLY if the instrumentation
that is eventually connected to the electric socket positioned inside the work chamber are "CE” marked or in
any case meets the standards mentioned in the above directives aiming to avoid any electromagnetic
interference.
All cabinets are provided with high insertion loss filters.

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
ENVAIR Lab LTD. disclaims any responsibilities for malfunctions, damages to people or properties due to non-
compliance, omitted or poor maintenance, and improper use of the equipment.
Attention: The ECOCHEM is not suitable for working in sterility and cannot be used either as biosafety
cabinet or for cytotoxic drugs.

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
2. INSTALLATION
2A. INSTRUCTIONS AND CHECKS ON DELIVERY
Installation plays an important role for ECOCHEM cupboards, whose use is sometimes critical; therefore they
should always operate under their best conditions.
The fume cupboards ECOCHEM are located on a pallet, wrapped into a stretchable film and placed inside a
multilayer strapped cardboard package.
For a general check, place the unit in its working place, open the package and remove the stretchable film,
then check if the unit has suffered from any dents or scratches due to transportation or incorrect handling.
In case of transportation, packaging and stocking by the user after a first period of use (i.e. Laboratory or
plant change), contact the technical service or the distributor in order to obtain accurate and precise
directions or to ask for the intervention of qualified technicians.
ECOCHEM fume cupboards - with or without packages - must always be sheltered from rain.
2B. INSTALLATION REQUIREMENTS
During installation, the unit shall be protected from draughts and heat sources (radiators, fan convectors) in
order to create the best working conditions.
- The clearance around the work opening shall measure at least XXXX mm.
- The front distance between the work openings of two cupboards used by one single operator shall
measure at least XXXXmm.
- No walls or obstacles should affect the air flow within XXXX mm from the work opening.
- No cupboard shall be installed where it could be disturbed by another equipment and/or unit.
- The distance between the work opening and any air source shall be at least XXXXmm.
- The distance between the front opening and the door or any other entrance way shall be at least
XXXXmm.
- The distance from the exhaust to the ceiling shall be at least XXXXmm.
Min. temperature 5 °C
Max. temperature: 40 °C
Max. Humidity: 80% at 31°C, linear drop in relative humidity down to 50% relative humidity
at 40°C.
Before connecting the fume cupboard to the main power supply, check the voltage and power on the label
next to the power cable. The room must be grounded, connected to the gas and/or vacuum network, if
required, and fitted with an air exhausting duct outside the building where the unit is to be installed (if air
shall be discharged outside, rather than recirculated in the environment).
The unit is always installed by authorized staff.

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
2C. ELECTRICAL/GAS CONNECTION
The electrical connection of the fume cupboard ECOCHEM is carried out by connecting the power cable
located on the upper of the right side of the cabinet to a suitable power point (see technical table). When
the cabinet is connected, the green light on the control panel switches on (see section 4D).
If provided by the laws in force, insert an automatic protection switch (at its maximum power) upstream on
the power input line. The switch shall be fitted with a differential relay with operating current rate not
exceeding 30 mA.
Any instrument with a heat source shall be located at a distance of at least 150 mm from the bottom and
side walls. Moreover we recommend not to use a flame at less than 300 mm from the adsorbing filter.
2D. POSITIONING OF THE CABINET ON THE SUPPORTING TABLE
ECOCHEM cupboards can be supplied with the relevant supporting table, which they have to be fixed to.
After assembling the supporting table (see instructions at section. 14) put the supporting table on a flat non
sloping floor and be sure that all the parts of the cabinet, that can be opened (control board panel and
window) are locked. Then position the cabinet on the table.

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
Technical Features Table
Description
Unit
ECOCHEM 60
ECOCHEM 90
ECOCHEM 120
ECOCHEM 150
ECOCHEM 180
Overall Dimensions (L x H x P)
mm
595x1120x760
885x1120x760
1185x1120x760
1500x1120x760
1800x1120x760
Usefull dimensions (L x H x P)
mm
553x660x600
823x660x600
1123x660x600
1438x660x600
1738x660x600
Maximum front aperture
mm
455
455
455
455
455
Working aperture
mm
200
200
200
200
200
Weigh
Kg
70
85
100
115
130
Noise level
dB (A)
52
52
52
52
52
Lighting level
Lux
>1000
>1000
>1000
>1000
>1000
Main voltage
V
230V AC 2P+T
230V AC 2P+T
230V AC 2P+T
230V AC 2P+T
230V AC 2P+T
Frequency
Hz
50
50
50
50
50
Power consumption (measured at 0.55m/s)
W
88
122
207
210
Current (measured at 0.55m/s)
A
0.527
0.665
1.06
1,23
Electrical class
1
1
1
1
1
Protection level
IP20
IP20
IP20
IP20
IP20
Internal outlet (maximum current for all the
sockets: 4A)
2P+T 230V 4A
2P+T 230V 4A
2P+T 230V 4A
2P+T 230V 4A
2P+T 230V 4A
Fluorescent lamps
W
2x15
2x18
2x30
2x36
2x58

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
3. OPERATION PRINCIPLES
The working process for the ECOCHEM is the following:
- Air is taken from outside through the front opening; the contaminant is removed at work surface level
and is carried upwards into the upper part or head of the fume cupboard, with an air flow.
- inside the fume cupboard head, air goes through a prefilter which cleans the air from particles and
aerosol or mist; then air goes through an activated charcoal filter (standard type and chemisorption
type) where the physical, chemical-physical and chemical reactions to remove the contaminant from
the air flow take place. The air is then exhausted outside the fume cupboard and recirculated in the
environment.

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
4. OPERATION
4A. SCOPE
The fume cupboards ECOCHEM are designed to protect the operator and the environment from fumes,
vapours and smells produced during routine laboratory operations whenever chemicals, reagents etc. are
used.
Their use is NOT recommended for particular workings which do not belong to laboratory routines, such as
those generating large quantities of evaporated solvents, acid digestions and the use with solvents whose
nature, structure and chemical formula are unknown.
4B. SYSTEM AND PERFORMANCE CONTROLS
The fume cupboards ECOCHEM are fitted with regulator in order to keep the airflow speed constant with the
progressive clogging/saturation of the main activated charcoal filter and prefilter.
The control panel is fitted with various controls, such as:
ECOCHEM-S
- manual regulation for airflow speed
- hours counter monitoring the real operation time of the fume cupboard
ECOCHEM-M
- microprocessor for air speed, prefilter and main filter efficiency automatic control
- alarm devices for low/high airflow speed, device monitoring possible explosive concentrations, motor
fan malfunctioning and gas sensor control
- hours counter monitoring the real operation time of the fume cupboard and the activated charcoal filter

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
4C. REMOTE SIGNALS (OPTIONAL AVAIBLE FOR ECOCHEM M)
The electronic control board can be improved with an output signal: it is possible to obtain a 12 Vdc output
to connect a LED light or alternatively a Normally Open voltage free contact to be connected to an external
circuit. This signal can be set in three different modes:
Motor ON:
The signal starts when ventilation is turned ON and stops when ventilation is OFF.
Alarm:
That signal is ON in case of any flow alarm and it is OFF when air flow rate is in the correct range.
AIR FLOW OK:
That signal is ON when air flow rate is in the correct range and it is OFF in case of any flow alarm.

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
4D. SYMBOLS OF CONTROL BOARD
List and description of all the symbols and controls of the control board:
4 15 11
1 2 3 5 6 7 8 9 10 12 13 14
1 MAIN SWITCH:
Position "OFF" in the "OFF" position, the green light of the mains voltage is on (4); the LCD
displays the model name. In this position the operator can activate only the
fluorescent light (12), the U.V. lamp (3) and the power outlet (13) (with plug
installed) and can activate the data stored in the microprocessor by
pressing the “Right Arrows” key (9-10).
Position "ON" Press the key "ON" [1], insert the password using the small numbers in the
right lower corner of the keys and press SET. Default password is 5 [9] – 4
[6]. When the password is typed in the green led of the switch lights up and
the cabinet starts operating, the motor-blower is powered and first "CHECK
PANEL" then "STAND-BY" appears on the display till the air flow reaches the
pre-set value. In addition, an audible alarm will sound intermittently during
this stand-by period, alerting the operator not to start working yet. When
the audible alarm stops and the message "STAND-BY" disappears from the
display. The air velocity is displayed.
NOTE: In any case, it is advisable to wait 5-10 minutes before starting work.

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
2 STAND BY
(Speed reduction) Not available:
3 U.V. Not available
4 LINE The green mains light switches on if the unit is connected to the mains and
the line is live
5-6UP/DOWN ARROWS Use the arrow keys to scroll through the menu, to program changing
parameters and to put in the password. Two passwords are programmed:
1) to start the cabinet and to enter the operator menu
2) to enter the main menu to change the data input (only allowed to be
authorized by technical staff and service because unsuitable interventions
can cause troubles and incorrect operation of the cabinet).
The same keys are also used to change the airflow speed within the
minimum and maximum set limits.
7 ESC ESC key deletes the operation of data input and goes back to the starting
condition.
When an alarm condition occurs, which is shown also by the message
appearing on the LCD. By pushing "ESC" the alarm stops sounding (only if
enabled). If the cause of the alarm is not resolved after 2 minutes the
buzzer starts to sound again.
8 SET SET key lets you enter the different functions or confirm the data input
going back to the upper level.
9-10LEFT/RIGHT ARROWS
(ONLY ECOCHEM M) Use the arrow keys to scroll through the menu: if pressed the following
data will appear on the display:
GAS concentration:
1, 2, Residual lifetime of filters: it is the operation time of the filters
installed in the cabinet that can be programmed by the user.
The LCD will display (for example)" RES. TIME FILTER 1=XXXX:XX h:min".
When such time is over, the message "CHECK FILTER (i.e.) 1". Will appear on
the line below.
The filters installed in the cabinet follow the numbering listed below
TYPE of FILTER
NUMBER

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
MAIN FILTER (CARBON OR HEPA)
1
SAFETY FILTER (CARBON OR HEPA)
2
LAF Power: it is shown indirectly by the power supply voltage of the motor,
expressed as percentage of max. Load voltage displayed also in proportion by a bar.
The display shows the notice (es.): "MOT.LAF = XX % " (max.100%).
Operating Time: Shows the operating time of the cabinet from the moment
when the main switch is positioned on "I"
The LCD will display (for example) "WORK TIME=XXXXXh”. This value cannot
be reset.
11 ALARM When an alarm occurs the red LED lights up.
12 LIGHT This switches on the fluorescent light; when enabled, the display shows
"Light on". Switching on the fluorescent light automatically the U.V. lamp
switches off.
13 SOCKET This supplies voltage; when enabled, if the PCB for the automatic regulation
is installed the display shows "POWER ON". The global current for all the
sockets installed on the cabinet is 4 Amps.
14 GAS Not available
15 DISPLAY ECOCHEM M: Rear light liquid crystal "LCD" display composed of 2 lines of
20 characters each showing the operating parameters and alarms.
ECOCHEM S: Rear light liquid crystal “LCD” display; it show the operating
time of the cabinet.

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk +44 (0) 1706 228416 info@envairlab.co.uk
4E. OPERATOR MENU (ONLY FOR ECOCHEM M)
It’s possible enter the operator menu, with the cabinet in stand-by mode and when the cabinet is switched on, by pressing at the same time the keys “ESC” (7) and “ARROW UP” (6).
Entering the operator menu while the ventilation is running it’s possible to set only the “ALARM CLOCK” and the “TIMER”.
OPERATOR MENU
Filter residual time
OPERATOR MENU
Language
OPERATOR MENU
Set up the clock
OPERATOR MENU
Change Password
OPERATOR MENU
History view
OPERATOR MENU
UV resid. time
STAND-BY MODE
PASSWORD
ESC + UP arrow
OPERATOR MENU
Set timer
OPERATOR MENU
Set alarm clock
OPERATOR MENU
UV program
SET TIMER
Set up hh:mm
SET ALARM CLOCK
Enable YES/NO
SET ALARM CLOCK
Date and hour
FILTER 1 LIFETIME
Set XXXX
UNAVAIBLE
FILTER 2 LIFETIME
Set XXXX
FILTER 3 LIFETIME
Set XXXX
LANGUAGE
Italiano
LANGUAGE
English
LANGUAGE
Francais
LANGUAGE
Deutsch
LANGUAGE
Espanol
SET UP THE CLOCK
Date and hour
UV LAMP
Set up 5000
CURRENT PASSWORD:
Psw:
SET UP PASSWORD:
Psw:
VERIFY PASSWORD:
Psw:

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
FILTERS RESIDUAL LIFETIME:
• Use “UP/DOWN arrow" keys [5/6] to choose the desired menu.
• select “FILTERS RESIDUAL LIFETIME.” and press "SET" [8] key; the display will show:
FILTER 1 RESIDUAL LIFETIME
Set XXXX
Where XXXX shows the number of the hours set for lifetime of the FILTER 1.
• Use the “up and down arrow” keys to adjust the hour’s parameter.
• Then press the "SET" key [8] to confirm the data and pass to filter 2 and so on up to filter 5 (as
for relation between number and type of filter see table section. 4C).
• To conclude programming, press ESC” [7] key.
LANGUAGE SELECTION
• use "UP/DOWN arrow" keys [5/6] to choose the desired menu
• select “LANGUAGE” and press the “SET” key and the following message will be shown on the display:
LANGUAGE
English
• With the “up and down arrow” keys select the desired language (Italian, English, French, German,
and Spanish).
• Press the “SET” key to confirm and exit the “LANGUAGE” menu.
• Press “ESC” [7] key to go out.

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
SET UP THE CLOCK
• use "UP/DOWN arrow" keys [5/6] to choose the desired menu
• select “SET UP THE CLOCK.” and press "SET" [8] key; the display will show:
SET UP THE CLOCK
Set XXXX
• Use the “left and right arrow” keys to select the desired parameter and set it using the “up and down
arrow” keys
• Then press the "SET" key to confirm the data and/or go back to previous menu
• To conclude programming, press ESC” [7] key.
PASSWORD CHANGE
• use "UP/DOWN arrow" keys [5/6] to choose the desired menu
• select “PASSWORD CHANGE” and press "SET" [8] key; the display will show:
CURRENT
PSW:
• digit the present Password then press “SET” key
SET UP PASSWORD
PSW:
• digit the new Password then press “SET” key
VERIFY PASSWORD
PSW:
• digit the password again and then press “SET” key to confirm the data and/or go back to previous menu
• To conclude programming, press ESC” [7] key.
DISPLAY OF HISTORICAL FILES
• use "UP/DOWN arrow" keys [5/6] to choose the desired menu
• select “ALARMS DISPLAY ” and press "SET" [8] key;
• Use “UP/DOWN arrow" keys to scroll through the list of the possible problems that have happened.
The list is in chronological order and contains up to 64 voices.
• To conclude programming, press ESC” [7] key.

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
ALARM CLOCK
• use "UP/DOWN arrow" keys [5/6] to choose the desired menu
• select “ALARM CLOCK” and press "SET" [8] key; the display will show:
Alarm clock set up
Set up XXXX
• Use the “left and right arrow” keys to select the desired parameter and set it using the “up and down
arrow” keys
• Then press the "SET" key to confirm the data and/or go back to previous menu
• Press “ESC” to abort the procedure
• When the set time is reached the buzzer start to ring and the display show this message
ALARM CLOCK
ALARM
• Press the “ESC” key to silence the acoustic signal
TIMER SET UP
• use "UP/DOWN arrow" keys [5/6] to choose the desired menu
• select “TIMER SET UP” and press "SET" [8] key; the display will show:
Timer set up
Set up XXXX
• Use the “left and right arrow” keys to select the desired parameter and set it using the “up and down
arrow” keys
• Then press the "SET" key to confirm the data and/or go back to previous menu
• Press “ESC” to abort the procedure
• At the end of the countdown the buzzer start to ring and the display will show this message:
TIMER
ALARM
• Press the “ESC” key to silence the acoustic signal

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
5. HOUR COUNTER / UV TIMER (ECOCHEM S)
Available only in English language.
5A. Hours counter
During the standard operating of the cabinet the display shows:
* CABINET LIFETIME *
0:00:42
The hour counter starts when the ventilation is switched ON and stop when the ventilation is turned OFF
It is possible RESET the hour counter pressing in sequence the following keys:
ESC – Arrow down – Arrow up – SET
After this the display will show this message:
WORKTIME RESET
Confirm? No
Change the answer with the arrow keys and press SET
5B. Energy save
The hour’s counter/UV timer PCB has the function: Energy save:
When the cabinet is in Stand by mode, after few minutes the display switch OFF (only the green LED
still remains lit).
To switch on the display it is necessary press any key
The functions of this PCB are available only in English language.

Registered in England. Company Registration Number: 10729379 VAT Registration Number: 268 3290 80
P0084EN Rev.03
www.envairlab.co.uk
+44 (0) 1706 228416
5C. DISPOSAL OF WASTES AND CONTAMINATED MATERIALS
DISPOSAL OF ELECTRIC AND ELETTRONIC DEVICES (AEE)
INFORMATION FOR EUROPEAN UNION USER
This symbol on the device means that when it needs to be disposed, it must be
handled separately from urban waste.
At the moment of the disposal, contact the dealer, to receive information about
the collect and disposal in accordance with the laws in force in the country.
Appropriate disposal of this product will help to prevent potential negative effects on health and the
environment and promotes re-use and / or recycling of materials of the equipment.
The improper disposal of the product by holder involves the application of sanctions in accordance with
the regulations in their own country.
INFORMATION FOR USERS OUTSIDE THE EUROPEAN UNION
This symbol is valid only in the European Union If you want to dispose this product, contact your local
authorities or dealer and ask for the correct method of disposal.
ATTENTION: Before disposal, the cabinet where contaminants and pathogens have been manipulated, must be
sterilized
The materials replaced during maintenance operations are activated charcoal filters and pre-filters.
Obviously, these materials are not toxic when they are new; they become toxic after using them, since they
absorb a number of contaminant agents (generally speaking chemical substances).The above materials shall
be considered just like the substances used in the fume cupboard. Therefore, for their disposal and
treatment, it is necessary to comply with the relevant local regulations and ministerial decrees.
5D. ERGONOMICS
This cabinet has been designed and manufactured according to the general directions on the ergonomics
provided for by the EN ISO 14738 standard.
Furthermore all maintenance operations are assured to be carried out in safety by merely following the
instructions given in this manual at section 7.
Table of contents
Popular Laboratory Equipment manuals by other brands

DDS Calorimeters
DDS Calorimeters CAL3K 3K-F installation guide

Leica
Leica CM1510 instruction manual

Excelitas Technologies
Excelitas Technologies X-Cite TURBO quick start guide

cytiva
cytiva Sterile Tube Fuser - Wet operating instructions

Digitus
Digitus DN-651141 Quick installation guide

Gilson
Gilson macroman user guide