EU Declaration of Conformity
According to Machinery Directive 2006/42/EC
Annex II Part 1 Section A and the Low Voltage
Directive 2014/35/EU
We, the Timilon Corporation
hereby declare as the responsible manufacturer
that
Product Name: EnviroKlenz® Air System Plus
Model: ED327-0255-230
Year of Production: 2021
Product Category: Air Purier
complies with the provisions of the relevant
Community harmonization legislation
mentioned above. All the relevant standards for
household and similar electrical appliances (EN
60335, EN 61000, EN 55014), including particular
requirements for air cleaning appliances, were
complied with.
0,6
0,6

user manual
(Original)
EnviroKlenz® Air System Plus with UVC Light,
Air Cartridge & HEPA Filter
Website: www.EnviroKlenzAirPuriers.eu
CBRN Protection GmbH
Brigittagasse 14/25-26
1200 Vienna, Austria
info@cbrn-protection.com
tel +43(0)69919667890
Timilon Corporation
3602 NW 16th Street
Topeka, KS 66618
United States of America
+1 239 330 9650

IMPORTANT SAFETY INSTRUCTIONS
Unit must be electrically grounded
• Insert plug on power cord directly into matching grounded
receptacle.
• Do not use with an adapter.
To reduce the risk of electric shock, this plug is intended to t in a
polarized outlet only one way. If the plug does not t fully in the
outlet, reserve the plug. If it still does not t, contact a qualied
electrician. Do not attempt to defeat this safety feature.
Keep wiring and motor dry
• Never use a water hose or pressure washer to clean electrical
components; water could enter the electrical compartment causing
a shock hazard.
• Do not operate in standing water.
• If electrical components become wet, allow them to dry completely
before using.
Fire and Electric Shock Hazard
2
READ AND SAVE THESE INSTRUCTIONS
Unplug this appliance from the power supply before
servicing
• Do not operate any fan with a damaged cord or plug. Discard fan
or return to an authorized service facility for examination and/or
repair.
• Do not run cord under carpeting. Do not cover cord with throw
rugs, runners, or similar coverings. Do not route cord under furniture
or appliances. Arrange cord away from trac area and where it will
not be tripped over.
Risk of Electric
Shock
Turn o the
power switch
before opening
Pull out the
main plug
before repairs &
maintenance
Do not dispose
of in a garbage
can
Do not look
directly into UV
light
• This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved.
Injury to Persons Hazard

If unit is used in hazardous or potentially hazardous environments such as mold mitigation
job sites:
• Wear protective gear when changing the HEPA lter as it may contain mold spores.
• Change The EnviroKlenz® Cartridge and HEPA lter after every remediation job.
• Dispose of used HEPA according to your local regulations.
• If using the air system in a containment work area (such as a restoration work site), turn o
all sources of power to open combustion appliances such as replaces, boilers, furnaces, water
heaters and HVAC systems to avoid the risk of back drafting deadly carbon monoxide fumes
from those appliances.
• Not recommended to stack units on top of each other.
• The unit can tip over if it is improperly set up or used.
• Falling equipment could cause bodily harm.
• Don’t sit on the unit to sit or store anything on it, nor use it as a
transportation equipment!
3
Injury to Persons Hazard
Tipping Hazard
WARNING:
UV Light Hazard
• WARNING - Skin or eye damage may result from directly viewing the light produced by the
lamp in this apparatus. Always disconnect power before relamping or servicing. Replace Lamp
With Lamp PL-L TUV 18 watt 4 pin bulb.
• You may contact EnviroKlenz®to order replacement lamps.
Not suitable for use with solid-state speed controls
The EnviroKlenz Air System Plus can be operated 24/7 and requires a replacement EnviroKlenz
Air Cartridge every 6 months and a replacement HEPA lter every 2 years. UV Bulbs should be
replaced when the exterior indicator light shows that one or both of the bulbs have burned out.
Both bulbs should be replaced at the same time, even if only one has burned out. Bulbs must
be disposed of as per your local law at an approved disposal station. The disposal fee has been
included in the purchase price.
• Children are not allowed to play with the appliance.
• Cleaning and user maintenance shall not be made by children without supervision.
Appliances that are obviously damaged must not be operated.



warnings
about enviroklenz®
inside system
set up & accessory replacement
best practices
settings & Controls
troubleshooting
contact, patents, & Product Family
warranty
2
7
8
10
13
14
16
17
18
20
table of contents
6
history & schedule

about enviroklenz®
Personal Environment Protection For Everyone
The entire EnviroKlenz team shares a commitment and passion for providing
people around the world with access to safe and eective solutions for improving
their indoor environments.
At EnviroKlenz, the goal and vision have always been dedicated to helping people
live healthier and more productive lives by providing clean air through a suite of
products and solutions.
mission
how it works
The EnviroKlenz® Air System Plus is your solution to improving your indoor
air quality by removing chemical odors, fragrances, VOCs, particulates,
microorganisms, and other allergy triggers all at once. The System utilizes
EnviroKlenz® Technology to adsorb and break down pathogens and chemical
pollutants coming from a broad array of sources. The EnviroKlenz® Air
Cartridge uses a patented blend of earth minerals that works to reduce and
remove contaminants without releasing any harmful chemicals or byproducts
back into your environment. The EnviroKlenz® Air System Plus also uses a
medical-grade HEPA lter for additional particulate capture, as well as UVC
lights for germicidal irradiation and interior sanitization.
7
warnings
about enviroklenz®
inside system
set up & accessory replacement
best practices
settings & Controls
troubleshooting
contact, patents, & Product Family
warranty
history & schedule

inside system
1. Air Intake
Air is brought in through the 3 top vented sides with 4 dierent speed
settings to choose from.
2. enviroklenz® air cartridge
The EnviroKlenz® Air Cartridge uses patented natural technology to
absorb and remove viruses, bacteria, VOCs and other chemicals without
the use of masking agents or harmful chemicals. In most situations, this
cartridge will need replacement after 6 months of use.
4. hepa filter
The HEPA lter captures particulates larger than 0.3 microns at a 99.97%
eciency rate. In most situations, the HEPA lter will need replacement
after 2 years of use.
5. clean air outtake
Filtered, clean air is directed out into the environment from the bottom vent.
On average, the air will be exchanged 3-5 times per hour on the highest set-
ting depending on the size of the room.
note: Be sure to follow your country’s electrical regulations.
8
1
3. UVC lights
UVC lamps are located above (and radiating on) the collection side of the
HEPA lter providing germicidal irradiation and interior sanitization of the
system.
5

2
3
9
4

set-up & accessory replacement
step 1: Make sure Air System is unplugged
and pull back on safety knob to slide up the
back panel to insert lters.
step 2: Slide in larger HEPA Filter with
airow arrow pointing down
10
safety knob

step 3: Install the UVC light bulbs by
carefully pushing them into the light
sockets inside the Air System.
* Avoid touching the glass portion of
the bulbs directly with your hands, as
it may shorten the lifetime of the UVC
bulbs.
11
step 4: Slide in smaller EnviroKlenz® Air
Cartridge above the UVC lights on the
rails with airow arrow facing down.

step 5: Slide down back panel by
pulling on the safety knob. Make
sure the bottom ledge is facing the
inside of the unit. Plug electrical
cord into a grounded outlet
step 7: Turn power control knob
to desired fan speed and begin
enjoying clean, allergen and
chemical free air
step 6: Turn on the UVC Lights
12

13
• Set up the air system in an area where it will provide good air circulation,
but won’t get in the way.
• To help maneuver air in the space, you may want to set up a few fans in
areas that are somewhat distant from the air unit(s). Have the
fan(s) push/blow the air towards the air unit(s). This will
help exchange the air so that it quickly gets processed through the
system.
• Do not place the air unit directly against a wall, as you want to ensure
airow.
• Leaving a system running 24/7 will help clear the air faster.
• Since the unit is relatively quiet, it can be run on medium or
high setting without disturbing normal activities.
Do’s
Don’ts
• Do not use with an ozone-producing machine because it can reduce the
efcacy of the EnviroKlenz Air System and limit the lifetime of the lters.
best practices
• The EnviroKlenz® Air Cartridge operates best when it is aligned
with the rail entrance.
• To acclimate the system to your environment, please run the system on
the whisp-air or low speed setting for the rst 24-48 hours.
• When changing the UVC bulbs
• Use protective equipment
• Only touch the lamps by the plastic sockets
• To avoid the potential for glass to enter the blower, the HEPA lter
must be installed or, if not possible, the nger protection grille
must be covered.

14
settings and Controls
• When the UVC lights are turned on, the indicator lights (2) should be
on and green. If the UVC light switch (4) is on, but the indicator light(s)
are off, the UVC bulb(s) need to be replaced.
2. UVC Light indicators
3. Speed Control Knob
1. Power Indicator Light
4. UVC Light Switch
• The Power Indicator Light (1) should illuminate when power
is owing to the system. If it is not illuminated, check the power
connection and ensure that the back panel is closed securely.

HIGH
MED
LOW
WHISP-AIR
OFF
HIGH
MED
LOW
WHISP-AIR
OFF
HIGH
MED
LOW
WHISP-AIR
OFF
HIGH
MED
LOW
WHISP-AIR
OFF
low
Setting ideal for environments with high levels
of physical particulate matter. This includes
heavy renovation, construction, re damage,
and ood damage.
Ideal for most situations in which a contaminate
source is noticeable but not overbearing, such as
cooking odors or outdoor pesticide use.
Ideal for everyday maintenance use when a
contaminate source is not overly present or
noticeable.
high
medium
Great for situations that require minimal noise
such as sleeping and watching TV.
This setting should be used for at least the rst
24-48 hours of running.
whisp-air
15

issue action
“Air System will not turn
on”
• Make sure Air System Plus is plugged in.
• Make sure the back panel is in place.
• Check power at the outlet.
• Test the on/off switch.
“The blower wheel is not
turning”
• Check for obstruction(s).
• Tighten set screw.
troubleshooting
16
“The System blower has
started to get louder” • It may be time to change your lters.
“UV indicator light(s) is
(are) off”
• Verify the UV feature is turned on
• UV Bulb may be burnt out or not properly
installed
“The HEPA lter is
difcult to remove”
• Make sure the thumbscrews holding the
HEPA in place have been loosened.
• Apply force in an upward direction on the
HEPA to loosen it from the seal with the
blower cage.

+44 20 3148 1800
Phone
Support@EnviroKlenzAirPuriers.eu
Email
contact
patents
EnviroKlenz® is a Registered Trademark of Timilon Corporation Bonita
Springs, Florida, USA. The EnviroKlenz® Air System Plus is produced in the
USA and is protected by multiple USA and International patents, including,
but not limited to patent numbers 7,276,640; 7,335,808; 7,661,483; 7,956,232;
and 8,038,935. 17
• UVC Lights or germicidal UV are at a much more specic wavelength
than what is termed “UV” broadly, which encompasses the
wavelengths of 100-380 nm. UVC are low-pressure lamps, more like a
uorescent lamp, with a specic wavelength of 253.7 nm (1182.5 THz).
• To create ozone from UV, the light wavelength would need to be in
the range from 160-240 nm.
• Since the EnviroKlenz Air System Plus uses UVC with a
wavelength of 254 nm, it is outside of the ozone-producing range.
• You can run the system without the lights being on, but you will
not get the benets of the UVC lights.
• Unintended use of the appliance or damage to the housing may result in the
escape of dangerous UV-C radiation. UV-C radiation may, even in little doses,
cause harm to the eyes and skin.
UVC Light Safety
CBRN Protection GmbH
Brigittagasse 14/25-26
1200 Vienna, Austria
info@cbrn-protection.com
tel +43(0)69919667890

Timilon Corporation warrants that for a period of two years from the date
of purchase, this product will be free from manufacturing defects. Timilon
Corporation, at its option, will repair or replace the product or any component
of the product found to have manufacturing defects during the warranty
period. If the product is no longer available, replacement may be made with
a similar product of equal or greater value.
This warranty is non-transferable and is valid from the date of the original
purchase. Proof-of-purchase is required to obtain warranty performance.
This warranty does not cover consequential damages and/or damages
resulting from negligent use or misuse of the product by failure to store,
maintain and/or use the product in accordance with directions otherwise. In
addition, disassembly, repairs, or modication by anyone other than Timilon
Corporation or acts of God such as re, ood, hurricanes, and tornadoes will
not be covered.
Limited Warranty
Timilon provides a 30-Day Return Window and the following limited
warranty. This limited warranty extends only to the original purchaser.
Please note that any warranty services or questions must be accompanied
by the order number from the transaction through which the warranted
product was purchased. The order number serves as your warranty number
and must be retained. Timilon will offer no warranty service without this
number.
Timilon warrants this product and its parts against defects in materials or
workmanship for two years labor and two-year parts from the original ship
date. During this period, Timilon will repair or replace defective parts with
new or reconditioned parts at Timilon’s option, without charge to you.
warranty
18
Table of contents
Other EnviroKlenz Air Cleaner manuals