ActivePure Surface & Air Guardian User manual

®
x2
®
READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION.
™

2
PRODUCT OVERVIEW
Congratulations on your purchase! Your new ActivePure®Surface & Air Guardian is designed to provide years of trouble-free,
low maintenance operation. Be sure to read and follow all service procedures outlined in this owner’s manual, and use only
genuine ActivePure replacement parts.
If you have any questions concerning this, or any ActivePure product, contact ActivePure
Customer Service at 800.572.1446 or email customerservice@ActivePure.com.
CONTENTS
Product Overview . . . . . . . . . . . . . . . . . . 2
Specifications . . . . . . . . . . . . . . . . . . . . 2
Storage and Disposal . . . . . . . . . . . . . . . . 2
Important Safety Instructions . . . . . . . . . . . . 3
For Canadian Customers Only . . . . . . . . . . . . 4
Inspection & Installation . . . . . . . . . . . . . . . 5
Unit Features . . . . . . . . . . . . . . . . . . . . 5
Operation . . . . . . . . . . . . . . . . . . . . . . 6
Seings & Adjustments . . . . . . . . . . . . . . . 6
LED Display . . . . . . . . . . . . . . . . . . . . . 7
Maintenance Reminders . . . . . . . . . . . . . . . 7
General Maintenance . . . . . . . . . . . . . . . . 8
Removing the Filter Assembly . . . . . . . . . . . . 9
Optional HEPA Filter Sheet . . . . . . . . . . . . . . 10
Removing the ActivePure®Cells. . . . . . . . . . . . 11
Installing the ActivePure®Cells . . . . . . . . . . . . 11
Troubleshooting . . . . . . . . . . . . . . . . . . . 12
Replacement Parts & Service. . . . . . . . . . . . . 13
Warranty Information . . . . . . . . . . . . . . . . 14
FCC Declaration & Responsible Party. . . . . . . . . 15
ActivePure Medical, LLC reserves the right to change or modify any
specification without notice.
SPECIFICATIONS
ActivePure Surface & Air Guardian
• Model Numbers: A1040F, A1040I
• Sales Numbers: 00758, 00763
Technology:
• ActivePure® (2 Cells) — ozone-free
• HEPA Filter Screen
• Activated Carbon Filter
• Carbon Brushes
Electrical:
• Input Voltage: 100 ~ 240 VAC; 50/60 Hz
• External Power Supply: DC 24 Volts; 1.5 Amps Max
• Power Consumption: 43 Was Max
• Conforms to UL STD 867
Mechanical:
• Nominal Airflow Rate: 40-60 CFM Adjustable
Speed Fan
Sound Level:
• 45 dB(A) on low; 55 dB(A) on high
Weight & Dimensions:
• 7.6 lbs (3.45 kg)
• 11.75” H x 9.5” W x 10” D (29.8 cm x 24.1 cm x 25.4 cm)
Operating Temperature:
• 34°F – 100°F (1.6°C – 38°C)
Recommended Maximum Coverage
in a Contiguous Space:
• Up to 1,000 sq. . (93m) depending on occupant
density and other factors. High density commercial
not to exceed 500 sq. . (46m2).
• For coverage in medical or health care environments,
Warranty:
• Limited three (3) year warranty
1. Assumes 8 foot ceilings. Solutions should be customized based upon a variety of factors
including HVAC system capabilities and seings, air flows taking into account walls, air
pressure, and doors, ambient air temperatures and humidities, variable density, known VOC
concentrations, and other layers of protection.
GENERAL INFORMATION
STORAGE AND DISPOSAL
Do not dispose of this product as household waste. Electrical
waste and electronic products should be appropriately
recycled as required by practices established by your
local authority.

3
CAUTION
Read this manual in its entirety before using your ActivePure Surface & Air Guardian
• Keep out of the reach of children
• NEVER place your unit where it may fall into a bathtub or other water container; to protect against electrical
hazards, DO NOT immerse in water or other liquids
• DO NOT touch the control panel or plug with a wet hands
• DO NOT run cord under carpeting; DO NOT cover cord with throw rugs, runners, or similar coverings; arrange
cord away from traic area and where it will not be tripped over
• DO NOT insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric
shock or fire, or damage the air cleaner
• To prevent a possible fire, DO NOT block the air intakes or exhaust in any manner; DO NOT use on so surfaces,
like a bed, where openings may become blocked
• To avoid fire or shock hazard, plug the unit directly into an electrical outlet
• To disconnect the unit, turn controls to OFF, then remove plug from outlet; pull firmly on the plug, DO NOT
unplug by pulling on the cord
• Always unplug the unit before moving or cleaning, or whenever the unit is not in use
• DO NOT use outdoors or on wet surfaces
• DO NOT aempt to repair or adjust any electrical or mechanical functions on this unit, doing so will void
your warranty
• Connect to properly grounded outlets only
• To reduce the risk of electrical shock, do not change the plug in any way; DO NOT use adapters
• Allow your ActivePure®Surface & Air Guardian to warm to room temperature before
operating; damage may result from turning on a cold unit
• Do not operate unit near heat sources, open flame, or combustible vapors or gases
• Eye damage may result from directly viewing the light produced by the lamp used in this
product; always turn o & unplug unit before removing filters or bulbs
• Do not operate this unit without the Filter Assembly and Back Cover installed
• Disconnect power cord before servicing
• When using electrical appliances, basic precautions should always be followed to reduce
risk of fire, electric shock, and injury to persons, including the following:
SAVE THESE INSTRUCTIONS
WARNING
IMPORTANT SAFETY INSTRUCTIONS

4
FOR CANADIAN CUSTOMERS ONLY
ACTIVEPURE®SURFACE AIR GUARDIAN
Sales No. : 00758, 00763
This UV device helps reduce the spread of viruses in the air.
Keep out of the reach of children
Please read the label and owner's manual before using: www.activepure.com/manuals
PRECAUTIONS:
WARNING: UV radiation emied from this device. Unintended use of the device, or damage to the housing, may result in
exposure to ultraviolet radiation. Ultraviolet radiation may cause eye and skin irritation. Avoid exposing eyes and skin to
ultraviolet radiation.
FIRST AID INSTRUCTIONS: Please contact your healthcare provider in the event of injury caused by this device.
DIRECTIONS FOR USE:
Plug the cord into a working electrical outlet, leaving at least one inch of open area to allow for airflow. Please see owner's
manual for detailed instructions on using, handling, storing and disposing of the device, and procedures to mitigate any
associated risks.
The use of this device is a supplement to and not a substitute for standard infection control practices; users must continue
to follow all current infection control practices, including those related to the cleaning and disinfection of environmental
surfaces.
FOR INQUIRIES CONTACT:
AERUS CANADA, INC.
Laird Business Park
3480 Laird Road, Units 2–5
Mississauga, Ontario, Canada, L5L 5Y4
W. Parrell, Manager
(905) 569-9399
Aerus Canada, Inc. is ailiated with ActivePure Medical, LLC
14841 Dallas Parkway, Suite 500, Dallas, TX 75254

5
INSPECTION INSTALLATION
• Exclusive ActivePure®Technology
• HEPA Filter Screen
• Activated Carbon Filter
• Multiple carbon brushes aid in the
capture of contaminants
• Five Speed Fan
• LED Display
• Maintenance Reminders
• Replaceable ActivePure®Cells
• Removable Rear Grill
• Universal Power Supply with Cords
UNIT FEATURES
1. Remove protective packaging
2. Remove unit from shipping carton
3. Remove all protective materials
4. Check for shipping damage and loose or broken parts
5. Read Owner's Manual thoroughly prior to installation
6. Determine placement location for the unit (See "Operation" on page 6)
7. Insert the Power Supply Plug into the power receptacle on the rear of the unit. Plug the
appropriate cord into the Power Supply and into a working electrical outlet
8. Using the Power Buon, turn the unit ON
®
Screwdriver

6
SETTINGS ADJUSTMENTS
OPERATION
The ActivePure Surface & Air Guardian can be turned on or o, and adjusted, using the control panel on the front of the unit.
NOTE: If you are operating your central heating and air conditioning fan or other ventilation system continuously, set
the coverage up to the total ventilated indoor area. Otherwise, set the coverage up to the size of the room.
CAUTION To prevent injury, be sure the power cord is not accessible to small children.
1. Take your ActivePure®unit out of the shipping carton
and remove all protective materials.
2. Place your unit in an appropriate location which
should be four feet or higher from the ground. Never
set it on the floor. Place in a location away from
the HVAC return duct. The rear of the unit requires
one inch or more of open area to allow unrestricted
airflow.
3. Insert the Power Supply Plug into the power
receptacle on the rear of the unit. Plug the
appropriate cord into the Power Supply and into a
working electrical outlet.
4. Push the Power button once to turn the unit on.
5. Push the A-PURE/A-PURE x2 button twice to set it
to A-PURE x2 level which will be illuminated on the
screen.
6. Push the Fan + button four times to reach the highest
speed (5th level).
• A·PURE MODE: The unit’s display shows the
fan speed (low to high) and A·PURE to indicate
that the ActivePure Cell and ionization are both
functioning normally.
• A·PURE x2 MODE: A·PURE x2 lights up, indicates
that (2) ActivePure Cells and ionization are both
functioning normally.
• ION MODE: Ion lights up, indicates only ionization
is functioning.
• CLEAN: Clean illuminates when cleaning is
required.
• RESET: Clears the maintenance reminders after
performing routine maintenance.
• CELL: The Cell light will flicker when it is time to
replace your ActivePure Cell.
For best results, run your ActivePure Surface & Air
Guardian 24 hours a day, 7 days a week, giving you
the benefits of ActivePure day and night.
POWER (STAND BY)
Turns the unit ON and OFF.
FAN UP/FAN DOWN
Adjusts the five speed fan.
A·PURE/A·PURE x2
Toggles the unit between A·PURE Mode
(ActivePure and Ionization) and A·PURE x2
Mode (2 ActivePure Cells and Ionization).
REMINDER RESET
Clears the maintenance reminders aer
performing routine maintenance.
Power ON/OFF
Reminder Reset Fan UP
Fan
DOWN
A·PURE /
A·PURE x2
x2
x2

7
x2
Modes (A·PURE /
A·PURE x2)
Fan Speed
(5 Levels)
Clean Filter
Assembly
Ion
Operation
Flicker: Replace ActivePure®Cell
Red Light: ActivePure®Cell Malfunction
LED DISPLAY
The LED Screen is used to display all current seings (see
page 6) as well as any maintenance reminders.
If a maintenance reminder or a service reminder appears, the
backlight will brighten and constantly flash until the Reminder
Reset icon is pressed or the service problem is corrected.
When maintenance is required, the Display Screen will brighten and flash and the Maintenance Reminder will appear.
MAINTENANCE REMINDERS
• Unplug the unit before performing any maintenance procedures
• Do not operate the ActivePure Surface & Air Guardian without the Filter Assembly and
Back Cover properly installed
WARNING
PERFORM CLEANING
• The perform cleaning CLEAN indicator will come on approximately every 180 days; for optimal performance, it is
recommended to perform cleaning on your unit every 30 days
• Clean the Filter Assembly (See Page 9)
• Vacuum the ActivePure Cells
• Vacuum Top and Rear Grill openings
NOTE: Be sure to press the Reminder Reset icon to clear the reminder following regular maintenance (See Page 6)
When the CLEAN indicator starts flashing, it reminds you to clean the filter.
Follow the steps below to remove the filter and clean it. While powered on, hold the Reset buon, approximately
three seconds, untilyou hear a beep sound alerting you that it has been cleared.
Hand Strap
1. Unplug unit
2. Press the top of
the back cover to
release the back
panel
3. Li up to remove
the back panel
4. Use the included
screwdriver to
unscrew the Filter
Assembly
5. Li the Filter
Assembly up
and out to
remove

8
Do not operate the ActivePure®Surface & Air Guardian without the Filter Assembly and
Back Cover properly installed.
WARNING
REPLACE ACTIVEPURE CELL
The CELL indicator will light up if the ActivePure Cell is no longer working. To order a new ActivePure Cell, contact
your sales representative or contact our Customer Service line at 800.572.1446.
NOTE: The ActivePure Cell should be replaced every one (1) year, even if the unit does not display this message.
When the CELL indicator starts flashing, you will need to perform the following operations to reset:
• Aer 1 year of cumulative use, the CELL indicator starts flashing. Aer the user replaces the new ActivePure Cell
according to the operation steps on page 10 of the manual, long press the RESET buon for three seconds
under the power o / standby state, you will hear a beep sound to let you know the reminder has been cleared.
When the CELL indicator starts flashing in red, you will need to perform the following operations to reset:
• The CELL indicator flashes in red to remind the user that ActivePure Cell is not properly installed. Aer
disconnecting the power supply, reinstall ActivePure Cell and check whether the socket is installed properly.
Aer the installation is successful, there is no need to press the RESET icon, the red light will automatically turn
o. Aer the above operations, if the indicator remains flashing in red, ActivePure Cell is possibly damaged. In
this case, contact Customer Service at 800.572.1446.
Reseing the Reminders
The reminders you need to reset are the PERFORM CLEANING and REPLACE ACTIVEPURE CELL indicators (aer
performing maintenance, press the Reset icon and the screen will stop flashing to let you know the reminder has been
cleared, please see above instructions for each indicator).
GENERAL MAINTENANCE
Unplug the unit before performing any maintenance procedures.
WARNING
Periodic maintenance is required to ensure that your ActivePure Surface & Air Guardian operates properly. The unit will
display a PERFORM CLEANING reminder when it's time to perform regular maintenance. If you are operating your unit in a
severely polluted environment, cleaning of the unit, ActivePure Cell, and Filter Assembly should be done more frequently.
Shown here are basic procedures that should be carried out to keep your unit running at top performance.
For optimal performance, and to prevent damage not covered by your warranty, install the Optional HEPA Filter. Failure to
perform routine maintenance could adversely aect the proper function of the unit or cause it to fail prematurely.
NOTE: If a unit is returned for repair, and it is determined that neglect of the unit or unauthorized tampering with any
mechanical or electronic component of the unit caused the failure, ActivePure reserves the right to void the
product warranty. This will require the owner to pay for any required repairs.
MAINTENANCE REMINDERS CONTINUED

9
REMOVING THE FILTER ASSEMBLY
WARNING
• Unplug the unit before performing any maintenance procedures
• Do not operate the ActivePure Surface & Air Guardian without the Filter Assembly and
Back Cover properly installed
Cleaning the Case
Wipe the unit with a so cloth dampened (not wet) with water. Do not use chemicals or solvents. Vacuum the Top and Rear
Grills periodically to remove any lint buildup.
Cleaning the ActivePure® Cells
Remove the ActivePure Cells and carefully vacuum accumulated lint. Do not wash the ActivePure Cells. Damage from water
may result.
Filter Assembly Cleaning
1. When visibly dirty, simply remove the Rear Filter Assembly from the unit (see page 8), and with a hand-held vacuum,
remove the heavy particulate. This method will extend the life of the Filter Assembly.
2. If the Filter Assembly can’t be cleaned by vacuuming, replace the Filter Assembly.
Filter Assembly Replacement
Contact your sales representative or ActivePure Customer Service at 800.572.1446 for replacement filters (see pages 9 – 10
for removal and installation instructions).
NOTE: Filter Assembly life will vary based on the operating environment.
Changing the ActivePure Cell
The ActivePure Cell should be replaced when REPLACE ACTIVEPURE CELL appears on the display, or twelve (12) months
when used continuously To change the ActivePure Cell, follow the instructions on page 11.
GENERAL MAINTENANCE CONTINUED
Hand Strap
1. Unplug unit
2. Press the top of
the back cover to
release the back
panel
3. Li up to remove
the back panel
4. Use the included
screwdriver to
unscrew the Filter
Assembly
5. Li the Filter
Assembly up
and out to
remove

10
The Optional HEPA Filter Sheet is designed specifically for areas with tobacco smoke, multiple pets, or anywhere
contaminants in the air could be prevalent.
• Protects your unit from indoor contaminants, which may shorten the life of your product
• Reduces monthly maintenance and cleaning time up to 90%
• Helps reduce odors
• Great in kitchen environments
• Helps reduce VOCs and other contaminants
NOTE: Removing the Optional HEPA Filter Sheet will increase the airflow of the unit.
UNINSTALLING THE OPTIONAL HEPA FILTER SHEET
Unplug the unit before performing any maintenance procedures.
WARNING
1. Remove the Filter
Assembly
(See Page 8)
2. Remove the
Optional HEPA Filter
Sheet on top of the
Prefilter
3. Replace the Filter
Assembly, inserting
the boom of the
Filter Assembly first
4. Use the included
screwdriver to screw
in the Filter
Assembly
5. Replace the Filter
Assembly, inserting
the boom of the
Filter Assembly first

11
REMOVING THE ACTIVEPURE®CELLS
CAUTION
Do not look directly at the glowing lamp. Prolonged exposure, even to reflected UV light,
can cause eye damage according to the American Conference of Governmental Industrial
Hygienists (ACGIH) Standards.
WARNING
• Unplug the unit before performing any maintenance procedures
• Do not operate the ActivePure Surface & Air Guardian without the Filter Assembly and
Back Cover properly installed
NOTE: Use genuine ActivePure replacement parts only. Parts from anyone other than ActivePure may damage your unit
and void your warranty.
1. Unlock the ActivePure Cell
connector by pressing on
the connector’s locking
tabs.
2. Pull the connector
straight out to
unplug.
3. Remove two (2)
thumbscrews.
4. Slide the ActivePure
Cell down and out of
the unit.
INSTALLING THE ACTIVEPURE®CELLS
WARNING
• Unplug the unit before performing any maintenance procedures
• Do not operate the ActivePure Surface & Air Guardian without the Filter Assembly and
Back Cover properly installed
1. Slide the ActivePure Cell up and
into the unit. Be sure the back lip
of the ActivePure Cell engages
the two sloed protrusions at the
rear of the unit, and that the angle
brackets and studs are correctly
aligned.
3. Press the connector firmly
until the two tabs lock into
place.
5. Use the included screwdriver
to screw in the Filter Assembly
6. Replace the Back Cover by
inserting the boom in first
and snapping it into place.
2. Insert the two thumbscrews
and tighten. Insert the
ActivePure Cell connector into
the plug at the rear of the unit.
4. Replace the Filter Assembly,
inserting the boom of the
Filter Assembly first

12
TROUBLESHOOTING
Indicators of Operation
When the unit is on, the LED display will show either the fan seing and A·PURE, A·PURE x2, or Ion.
Troubleshooting — What To Look For First
1. I have plugged in the unit, pressed the ON buon on the ActivePure® Surface & Air Guardian, and nothing happens.
What’s wrong?
• Make sure the power cord is inserted completely into the receptacle on the back of the unit
• Make sure the electrical outlet is capable of providing power to the unit
2. The UV Lamp is not functioning / I’m geing a “Replace ActivePure Cell” Message.
• Check ActivePure Cell for proper installation
• Replace the ActivePure Cell
3. What are the most typical application problems?
• Symptom: A belief that the proper equipment is placed in the environment and the equipment appears unsuccessful
• Problem: Lack of air movement, improper placement of the unit
• Symptom: Visual haze of smoke and/or particulate remain within the environment
• Problem: Lack of ionization and/or air movement
4. Air flow is restricted or reduced.
• Is the unit properly placed away from objects that may obstruct air flow?
• Are the Filter Assembly, Back Cover, and Top and Rear Grill clean?
• Is the ActivePure Cell clean?
5. How can I tell if the ActivePure Cell is functioning?
• The ActivePure Cell will produce a glow that is visible through the Top and Rear Grill under low light conditions
6. Unit does not operate.
• Is the unit plugged in?
• Are you sure the outlet is active?
• Are the Filter Assembly and Back Cover installed properly?
If your unit fails to operate properly after performing troubleshooting contact your sales
representative or ActivePure Customer Service for further assistance at 800.572.1446 or
email customerservice@ActivePure.com.

13
REPLACEMENT PARTS QTY PART NUMBER
ActivePure® Cell 50105 (Model: A1040F); 50222 (Model: A1040I)
Filter Assembly 50107
Power Supply with U.S./Euro Plug 50108
To order replacement parts, contact your sales representative or ActivePure Customer
Service for further assistance at 800.572.1446 or email customerservice@ActivePure.com.
REPLACEMENT PARTS SERVICE
ActivePure Cells are not interchangeable. Using the incorrect cell for your model will
damage the unit/cell.
WARNING

14
WHAT IS COVERED BY THIS WARRANTY
We warrant the ActivePure Surface & Air Guardian
(excluding filters) to the consumer, subject to the conditions
below, against defects in workmanship or material, provided
that the products are returned to ActivePure Medical, LLC
within the following time periods:
• ActivePure Surface & Air Guardian within three (3) years
from date of purchase
• ActivePure Cell within one (1) year from date of purchase
MAINTENANCE REQUIREMENTS
This warranty is expressly conditioned upon proper
operation, cleaning and maintenance, all in accordance
with the Owner’s Manual. Failure to meet any of these
requirements will void this warranty. Servicing of your
ActivePure Surface & Air Guardian by parties other than
our authorized representative and/or using parts other than
genuine parts will also void this warranty. This warranty is
contingent upon:
• Replacing the ActivePure Cell every one (1) year with a
genuine ActivePure part (proof of purchase required)
• Cleaning the Filter Assembly every 30–180 days days
(according to instructions in Owner’s Manual)
• Replacing the Filter Assembly every 6–12 months (proof
of purchase required)
HOW TO OBTAIN WARRANTY SERVICE
Customer must contact ActivePure Customer Service or
go online to www.activepure.com/warranty to activate their
warranty within 6 months of purchase. We will repair or
replace and return the product, without charge and within
a reasonable period of time, subject to the conditions in
the above paragraphs, if its examination shall disclose
any part to be defective in workmanship or material. If we,
in our discretion, are unable to repair the product aer a
reasonable number of aempts, we will provide either a
refund of the purchase price or a replacement unit, at the
company’s option.
WHAT IS NOT COVERED BY THIS WARRANTY
Ordinary wear and tear shall not be considered a defect in
workmanship or material. These warranties do not apply
to filters nor for loss or damage caused by accident, fire,
abuse, misuse, improper installation, modification, or
misapplication.
MISSING SERIAL NUMBERS AND UNAUTHORIZED
CHANNELS
If a valid serial number is missing from the product, the
warranty will be voided. Warranties are voided if a product
is purchased through unauthorized channels, this includes
websites that are not authorized to sell our products OR to
use ActivePure trademarked names, images and logos as
well as Internet auction sites (e.g. ebay and Craigslist). The
only approved Internet presence for ActivePure products is
www.activepure.com and www.activepuremedical.com. To
confirm warranty coverage prior to purchasing a product,
contact ActivePure Customer Service at 800.572.1446 with
the serial number located on the back of the unit.
EXCLUSION OF OTHER WARRANTIES AND CONDITIONS
EXCEPT AS PROVIDED HEREIN, AND TO THE
EXTENT CONSISTENT WITH APPLICABLE LAWS,
WE MAKE NO REPRESENTATION OR WARRANTY OF
ANY KIND. ALL OTHER WARRANTIES OF ANY KIND,
EXPRESS OR IMPLIED, ARE HEREBY EXPRESSLY
DISCLAIMED, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
LIMITATION OF LIABILITY FOR SPECIAL, INCIDENTAL,
OR CONSEQUENTIAL DAMAGES
TO THE EXTENT CONSISTENT WITH APPLICABLE
LAWS, WE SHALL NOT IN ANY CASE BE LIABLE
FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES ARISING FROM BREACH OF EXPRESSED OR
IMPLIED WARRANTIES, CONDITIONS, GUARANTEES
OR REPRESENTATIONS, BREACH OF CONTRACT,
NEGLIGENCE OR ANY OTHER LEGAL THEORY. Such
excluded damages include, but are not limited to, loss of
profits or revenue, and loss of the use of the products.
FOR U.S. APPLICATION ONLY
This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state. Some
states do not allow limitations on warranties, or on remedies
for breach. In such states, the above limitations may not
apply to you.
FOR CANADIAN APPLICATION ONLY
Exclusion of Subsequent Owners: Except as otherwise
required by applicable legislation, this warranty is not
transferable. This warranty gives you specific legal rights
and you may also have other rights which vary from province
to province. Some provinces and territories do not allow
limitations on warranties, or on remedies for breach. In such
provinces or territories, the above limitations may not apply
to you. If any provision of this warranty or part thereof is
held by a court of competent jurisdiction to be invalid, illegal,
or unenforceable, the validity, legality and enforceability of
the remaining provisions or parts thereof will not in any way
be aected or impaired within the jurisdiction of that court.
This entire warranty shall continue to be valid, legal and
enforceable in any jurisdiction where a similar determination
has not been made.
This warranty is provided by:
ActivePure Medical, LLC
14841 Dallas Parkway, Suite 500
Dallas, TX 75254
SERVICE
Every eort is made to ensure customers receive an up-
to-date instructions manual on the use of our products;
however, from time to time, modifications to our products
may without notice make the information contained herein
subject to alteration. For the latest information, please visit
our website at www.activepure.com.
WARRANTY INFORMATION
Limited Three (3) Year Warranty:
To register your ActivePure® Surface & Air Guardian unit, visit www.activepure.com/warranty.

15
FCC Declaration of Conformity
Name: ActivePure® Surface & Air Guardian
Model: A1040F, A1040I
Manufactured for: ActivePure Medical, LLC
This device complies with Part 15 of
the FCC Rules.
Responsible Party
ActivePure Medical, LLC
14841 Dallas Parkway, Suite 500
Dallas, TX 75254
Ph: 800.572.1446
Signature:
Printed Name: Andrew Eide
Title: Vice President of Product Development
and Manufacturing
Date: 12/27/21
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant of part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio
frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However,
there is no guarantee that interference will not occur
in a particular installation. If this equipment does
cause harmful interference to radio or television,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct
the interference by one or more of the following
measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment
and receiver.
•
Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected.
•
Consult the Independent Contractor for help.
FCC DECLARATION RESPONSIBLE PARTY

ASAG_OM_65-00834_VA-01641
For information regarding the use of this product please call Customer Service.
1.800.572.1446 or email at customerservice@ActivePure.com
www.activepure.com
™
ActivePure Medical, LLC | 14841 Dallas Parkway, Suite 500 | Dallas, TX 75254 | 800.572.1446
Assembled in P.R.C. | © ActivePure Medical, LLC. All Rights Reserved
Other manuals for Surface & Air Guardian
1
This manual suits for next models
2
Table of contents
Other ActivePure Air Cleaner manuals

ActivePure
ActivePure GUARDIAN AIR User manual

ActivePure
ActivePure F159L User manual

ActivePure
ActivePure Guardian Pro User manual

ActivePure
ActivePure Beyond Guardian User manual

ActivePure
ActivePure TRANSIT GUARDIAN B101A User manual

ActivePure
ActivePure Surface & Air Guardian User manual

ActivePure
ActivePure INDUCT GUARDIAN IV User manual

ActivePure
ActivePure INDUCT GUARDIA N II User manual

ActivePure
ActivePure Transit Guardian External User manual

ActivePure
ActivePure Induct Guardian I User manual