EnviroKlenz Mobile air system User manual

Mobile air system
user manual


user manual
EnviroKlenz®Mobile Air System, 250 CFM
with Air Cartridge & HEPA Filter
Personal Environment Protection For Everyone
13421 Parker Commons Blvd., Suite #102
Fort Myers, FL 33912 U.S.A.
Phone: 239-330-9650
Email: [email protected]
Website: www.EnviroKlenz.com 1

warnings
Unit must be electrically grounded.
• Insert 3-prong plug on power cord directly into matching
grounded receptacle.
• Do not use with a three-prong/two-prong adapter.
Keep wiring and motor dry.
• Never use a water hose or pressure washer to clean electrical
components; water could enter the electrical compartment causing a
shock hazard.
• Do not operate in standing water.
• If electrical components become wet, allow them to dry completely
before using.
Unplug unit before performing any maintenance.
fire and electric shock hazard
hazard
• If using the processor in a containment work area, turn off all sources of
powertoopencombustionappliancessuchasreplaces,boilers,
furnaces, water heaters and HVAC systems to avoid the risk of back
drafting deadly carbon monoxide fumes from those appliances.
2

contamination hazard
If unit is used in hazardous or potentially hazardous environments
such as mold mitigation job sites:
• WearNIOSH-approvedprotectivegearwhenchangingtheHEPAlter
as it may contain mold spores.
• Change The EnviroKlenz®CartridgeandHEPAlterafterevery
remediation job.
• Dispose of used HEPA according to your local regulations.
tipping hazard
• Not recommended to stack units on top of each other.
• When stacking units, for storage or transportation in original packaging,
beware of tipping.
• Falling equipment could cause bodily harm.
3



warnings
about enviroklenz®
inside system
lab testing
• AcidGas(HydrogenSulde)
• NitrogenCompound(Ammonia)
• Formaldehyde(CommonIndoorAirPollutant)
• Efcacy
set up & cartridge replacement
best practices
settings
troubleshooting
contact, patents, & Product Family
warranty
2
7
8
10
16
18
19
20
21
22
table of contents
6

warnings
about enviroklenz®
inside system
set up & cartridge replacement
best practices
settings
troubleshooting
contact, patents, & Product Family
warranty
about enviroklenz®
Personal Environment Protection For Everyone
The creation of EnviroKlenz®was inspired by our Customers with multiple
chemical sensitivities and environmental illnesses. We have been honored
to be able to work closely with them and learn from their experience and
feedback. Through their recommendations, we introduced a product line
that is both effective and safe for everyone- especially those with illnesses
triggered by environmental exposures.
mission
how it works
The EnviroKlenz®Mobile Air System is your solution that improves your
personal environment air quality by removing chemical odors, fragrances,
VOCs, particulates, and allergens all at once through a 2 stage process.
Stage 1 consists of the patented EnviroKlenz®technology to neutralize
chemicals, pollutants, and fragrances, Stage 2 removes harmful dust,
particulate, allergens, pet dander, and more.
Theprocessutilizesmultistagetreatmentandltrationenhancedwith
EnviroKlenz®technology to adsorb, neutralize, and eliminate chemical
pollutants coming from a broad array of sources while removing airborne
particles such as dust and miscellaneous debris. The small size of the air
processor allows it to be portable and easily maneuverable.
Theprocesscombinesairow,particulateltration,andtheadvanced
odor-treatment technology of EnviroKlenz®to improve indoor air quality.
The processor moves air through an EnviroKlenz®AirCartridge(stage1)
andaparticulatelter(stage2).Whatmakesthetotalprocessuniqueis
the use of the EnviroKlenz®advanced odor-treatment technology for the
control of odor-causing molecules and a broad array of hazardous indoor
pollutants. 7

inside system
1. Air Intake
Air is brought in through the 3 top vented sides with 4
different speed settings to choose from, ranging from
85 - 250 CFM.
2. enviroklenz® air cartridge
The EnviroKlenz®Air Cartridge uses patented, natural
technology to adsorb and neutralize VOCs and other
chemicals, without the use of masking agents or harmful
chemicals. In most situations, this cartridge will need
replacement after 6 months of use.
3. hepa filter
HEPAltercapturesparticulateslargerthan0.3micronsat
a99.99%efciencyrate.Inmostsituations,theHEPAlter
will need replacement after 2 years of use.
4. clean air outtake
Filtered, clean air is directed out into the environment
with the bottom vent. On average, the air will be
exchanged 3 - 5 times per hour on highest setting
depending on the size of the room.
note: Be sure to use and follow your country’s electrical regulations.
8
1
4

2
3
9

Acid gas ( hydrogen sulfide )
Hydrogensuldeisanacidicgasthathasastrongodorofsulfuror
rotten eggs. It is a common pollutant that can come from sewage,
organicdecay,combustion,gases/fuels,andmore.Hydrogensuldeis
similar to many acids, and EnviroKlenz®has similar results against other
sulfur-containing compounds.
0
10
20
30
40
50
60
70
80
90
100
EnviroKlenz®
Carbon Filter Air System
Photocatalytic System
Time span of 60 min
EnviroKlenz® Mobile
Air System
lab testing
10

Nitrogen compound ( ammonia )
Ammonia has a very potent odor and is considered to be hazardous. It
is a pollutant that is commonly found in household cleaning products.
EnviroKlenz®has similar results against related chemicals, including
amines which are derivatives of ammonia and common air quality
pollutants.
0
10
20
30
40
50
60
70
80
90
100
EnviroKlenz®
Carbon Filter Air System
Photocatalytic System
Time span of 30 min
EnviroKlenz® Mobile
Air System
11

Formaldehyde ( common indoor air pollutant )
Formaldehyde can off-gas from varnishes and paints and is one of many
compounds found in cigarette smoke. It is often found in manufactured
products, synthetic materials, and building products such as pressed
materials. EnviroKlenz®has similar results against a variety of volatile
organiccompounds(VOCs).
0
10
20
30
40
50
60
70
80
90
100
EnviroKlenz®
Carbon Filter Air System
Photocatalytic System
Time span of 90 min
12
EnviroKlenz® Mobile
Air System

• U.S. Army Center for Health Promotion
and Preventive Medicine
• U.S. Army Edgewood Chemical
Biological Center
testing labs
• Battelle Memorial Institute
• Coal Mines Technical Services
• Lloyds Registry
• MPI Research, Inc.
• Nelson Laboratories
Efficacy
The EnviroKlenz Technology has been extensively tested by leading
laboratories around the world. This list includes, but is not limited to:
EnviroKlenz®has been tested and proven effective against a broad
spectrumofhazardouschemicalsandvolatileorganicchemicals(VOCs).
Partial List of Common Compounds That Can Be Successfully Removed/
Neutralized by The EnviroKlenz® Technology.
13



setup & cartridge replacement
step 1: Make sure Mobile System is
unplugged and slide up the back panel
to remove
step 2: Slide in larger HEPA Filter with
airow arrow pointing down
16

step 3: Slide in smaller Enviroklenz®Air
Cartridge to rest on top of HEPA lter with
airow arrow facing down
step 4: Replace sliding back
panel with blank side facing out
step 5: Plug Electrical cord into a
grounded outlet (Indicator light
will illuminate to show power
coming to the system)
step 6: Turn power control knob
to desired fan speed and begin
enjoying clean, allergen and
chemical free air
17

• Set up the air system in an area where it will get good air circulation, but
won’t also get in the way.
• To help maneuver air in the space, you may want to set up a few fans in
areasthataresomewhatdistantfromtheairunit(s).Havethefan(s)
push/blowtheairtowardstheairunit(s).Thiswillhelpexchangetheairso
that it quickly gets processed through the system.
• Do not place the air unit directly against a wall as you want to ensure
airowandairmovement.
• Leaving a system running 24/7 will help clear the air faster.
• Since the unit is relatively quiet, it can be run on medium or high setting.
Do’s
Don’ts
• Do not use with an ozone-producing machine.
best practices
18
Detailed Best Practices
Table of contents
Other EnviroKlenz Air Cleaner manuals