enviroswim ES-3 User manual

eenviroswim.com
ES3 VERSION3
FRESH WATER SANITISING SYSTEM
fresh water swimming pools
fresh water swimming pools


1
eennviroswim..ccom
TABLE OF CONTENTS
1. IMPORTANT SAFETY & WARNING INFORMATION...................................................................2
1.1Important Warnings...........................................................................................................2
1.2Important Safety Information .............................................................................................2
1.3Helpful Hints & Recommendations.....................................................................................2
2. GENERAL OVERVIEW...............................................................................................................3
2.1Contents...........................................................................................................................4
3. SYSTEM OPERATION...............................................................................................................5
3.1 Electronic Control Unit ......................................................................................................5
3.1.1 Time Clock....................................................................................................................5
3.1.2 AUTO/OFF/MANUAL (A/O/M) Switch............................................................................6
3.1.3 ON/OFF Switch.............................................................................................................6
3.1.4 Fuse .............................................................................................................................6
3.1.5 Ultra Sonic Indicator LED ..............................................................................................6
3.1.6 Ioniser Timer Control.....................................................................................................6
3.1.7 Ioniser Polarity Indicator ................................................................................................7
3.1.8 Oxidiser Digital Display..................................................................................................7
3.1.9 Oxidiser Output Control ................................................................................................7
4.ENVIROSWIM PARAMATERS & WATER BALANCE ................................................................8
4.1 Enviroswim Operating Parameters ....................................................................................8
4.2 Water Balance Standards .................................................................................................8
5. INITIAL START UP - COMMISSIONING.....................................................................................9
5.1 New Pool Start Up or Pool Refills.......................................................................................9
5. INITIAL START UP – COMMISSIONING cont...........................................................................10
5.2 Salt Water Conversion - Startup .....................................................................................10
6. MAINTENANCE ......................................................................................................................11
6.1 Fuse ...............................................................................................................................11
6.2 Replacement of Ionisers (electrodes) ..............................................................................11
6.3 Oxidiser Cell Plates - Cleaning ........................................................................................12
6.4 Copper Testing...............................................................................................................13
6.5 Adjusting and Maintaining Water Balance........................................................................14
6.6 Winterise Your Pool.........................................................................................................14
6.7 Pool Covers....................................................................................................................14
7. TROUBLESHOOTING .............................................................................................................15
8. SPECIFICATION, STANDARDS and WARRANTY ....................................................................17
8.1 Specifications .................................................................................................................17
8.2 Standards.......................................................................................................................17
8.3 Warranty.........................................................................................................................18
9. POOL SHOPS and SERVICE TECHNICIAN INFORMATION.....................................................19
fresh water swimming pools
fresh water swimming pools

2
e
enviroswim.com
1. IMPORTANT SAFETY & WARNING INFORMATION
1.1 Important Warnings
oThis manual should be retained by the operator and or the owner of this equipment.
oThis equipment shall be installed according to AS/NZS 3000 wiring rules and outside the
pool zone. Please refer to the ES3 installation guide.
oThe Electronic Control Unit should not be opened by an unauthorised person. There is a
danger of electrical shock if opened and any warranty will be voided.
oThe Enviroswim ES3 system should only be operated when the wet cell is completely full of
water and the water is flowing.
oThe system should never operate without the pool pump operating.
1.2 Important Safety Information
oChildren should be supervised to ensure they do not operate or touch the equipment.
oNever put undiluted chemicals to your pool, always dilute in a bucket of water first.
ALWAYS ADD CHEMICALS TO WATER
. Never add water to chemicals.
NEVER STORE CHEMICALS IN THE VICINITY OF YOUR ENVIROSWIM CONTROL BOX
1.3 Helpful Hints & Recommendations
oRead and keep your manual in a safe place.
oClean your pool filter, skimmer and pump lint basket regularly.
oIf using a VARIABLE SPEED PUMP, please ensure there is adequate water flow and the wet
cell is filled with water at all times when in use.
oWhen a large number of swimmers are using the pool, switch the unit on to manual if the
system is not already operating.
oEnsure your copper levels are between 0.2-0.4ppm. Check weekly and only check your
copper levels when your pH is between 7.1 -7.4. Please use the copper test kit supplied with
your Enviroswim ES3 system.
oMaintain the TDS (Total Dissolved Solids) level between 1,000 – 1,500ppm, for optimum
performance, longevity of the oxidiser cell plates and to enjoy a Fresh Water Experience.
Do not use: Stabiliser (Cyanuric Acid) Aluminium based or any other Flocculants
Bromine Compounds Granular Chlorine or tablets
Soda Ash (Sodium Carbonate) Forms of Volcanic Filtration Media (Zeolite)
Do not put un-dissolved chemicals into your pool

3
e
enviroswim.com
2. GENERAL OVERVIEW
Thank you and congratulations on purchasing your Enviroswim ES3 Freshwater Sanitiser,
the world’s safest and most effective sanitiser. Please take the time to read the entire
manual before operating your new system. Your system must be installed and operated as
per the ES3 User Manual & Installation Guide.
While every effort has been made to ensure that the information supplied in this manual is
accurate and complete, no liability will be accepted for any errors or omissions. Enviroswim
reserves the right to change the specifications of hardware and or software or
documentation at any time without prior notice.
The ES3 sanitises swimming pools up to and including 100,000 L. Please consult us for
larger pools and commercial applications.
The ES3 is designed to operate
1 hour per 10,000 L
of water per day.
Ensure pH levels are not above 7.5 for extended periods of time. If you test copper levels
when your pH is high you will not obtain an accurate reading.
The Enviroswim ES3 is not designed to chemically maintain the balance of your pool water.
It is designed to sanitise correctly balanced water. Please ensure you balance and check
your water regularly, adjusting where necessary. During periods of intense use or when your
pool water has been significantly diluted or contaminated, more frequent testing and
management may be required.
Please note the copper and silver electrodes are sacrificial and will be required to be
replaced from time to time. The rate of usage of these electrodes will vary depending on the
size of your pool, ioniser control setting, run time, bather load and the environment. For an
average residential size pool (40,000L) with normal environmental influences, rods will
typically last 2 years.
Thank you again for choosing the world’s leading swimming pool sanitiser.
For further information please visit our website.
enviroswim.com
For purchasing consumables, please visit our online store.
enviroswim.com/online-store
Happy Freshwater Swimming from the Enviroswim Team.

4
eennviroswim..ccom
2
2. GENERAL OVERVIEW cont.
2.1 Contents
1 x ES3 Electronic Control Box
1 x Complete Oxidiser
/
Ioniser Wet Cell
Housing
1 x
Ultrasonic Chamber
1 x Enviroswim Copper
Test Kit
4 x 50/40 mm
Reducing Bushes
1 x Power Cable
Documentation
:
o1 x Installation Guide
o1 x Users Manual

5
e
enviroswim.com
3. SYSTEM OPERATION
3.1 Electronic Control Unit
3.1.1 Time Clock
If using the Timer:
The outer dial should be set to the current time. Rotate
the dial slowly in a clockwise direction until the correct
hour is aligned with the arrow printed on the dial.
Note the outer dial is printed with the 24hr clock
8.00am = 8 on the dial
8.00pm = 20 on the dial
ONLY ROTATE TIMECLOCK BY THE OUTER DIAL
DO NOT ATTEMPT TO ROTATE THE DIAL IN AN
A
ANTI
-CLOCKWISE DIRECTION
1. Time Clock
2. OFF/MANUAL/AUTO Switch
3. ON/OFF – Enviroswim Functions Switch
4. Fuse
5. Ultrasonic Operation Indicator
6. Ioniser Timer Control
7. Ioniser Polarity Indicator
8. Oxidiser Amperage Display
9. Oxidiser Output Control
PROGRAMMING SWITCHING TIMES
Set tappets to outer edge for ON periods and set
tappets to inner edge for OFF periods
Multiple ON/OFF periods can be set if required.
The Time Clock has a battery backup and will
retain the time.

6
e
enviroswim.com
3. SYSTEM OPERATION cont.
3.1.2 AUTO/OFF/MANUAL (A/O/M) Switch
oAUTO position - the ES3 system and pump will run, as per the settings on the time clock.
oOFF position - turns all functions off. The time clock will not function but will keep time.
oMANUAL position - turns the pump and ES3 System on, bypassing the time clock.
3.1.3 ON/OFF Switch
oThe ON/OFF switch turns the ES3 System ON or OFF.
oFor your system to operate correctly this should be in the ON position.
oBy selecting the OFF position and the A/O/M switch to AUTO function (3.1.2), your pump
will still run via the time clock.
oTo backwash your pool, switch to OFF and the A/O/M switch to MANUAL function (3.1.2).
The pump will run manually.
3.1.4 Fuse
oOnly replace with 240v 5A slow blow
3.1.5 Ultra Sonic Indicator LED
oLED cycles through several colours indicating normal operation
3.1.6 Ioniser Timer Control
oThis control is time based.
o
Copper levels can be increased 2 ways, by increasing the run time and/or increasing the
ioniser setting.
oThe “MAX-Start up” setting is for commissioning your Enviroswim ES3
system. This should
only be used to build up a residual of copper/silver when your pool is first commissioned,
or
your pool has been drained.
oEvery pool has its own demand for sanitisation.
Once the commissioning process has been
completed, most pool owners set their ioniser at 20-40%.

7
eennviroswim..ccom
3
3. SYSTEM OPERATION cont.
3.1.7 Ioniser Polarity Indicator
oThis LED indicator changes colour from red to green every 6-10 minutes of run time. It
assists cleaning and even wear on your electrodes.
oThis LED is not always on, even when the system is running. It is only on for a percentage of
the run time, dependant on the ioniser timer control setting.
3.1.8 Oxidiser Digital Display
This display shows the status of the oxidiser plates and conductivity of your pool water. It displays a
range of values and operating codes.
Normal Operation Oxidiser Codes:
od6 – System in degas Mode. The system reverses polarity every 24 hours of run time. The
d6 will display for a few minutes while in degas mode.
o01-15 – Indicates amperage current being applied to the oxidiser plates. For swimming
pools when the oxidiser knob is in the MAX position, this should display 15 amps.
Please find further information regarding error codes in trouble shooting section on page 16.
3.1.9 Oxidiser Output Control
oThis control is used to adjust the current being applied to the oxidiser plates. For normal pool
operation this should be s
set to MAX
.
oFor spa use this output may need to be reduced depending on the specific spa usage and
setup.
oExtended run times and/or high salt levels and/or not removing your pool blanket frequently
may result in excessive chlorine levels. Please reduce oxidiser output.

8
e
enviroswim.com
4.
ENVIROSWIM PARAMATERS & WATER BALANCE
4.1 Enviroswim Operating Parameters
oTotal Dissolved Solids (TDS)
1,000
– 1,500ppm
oCopper
0.2 – 0.4ppm
oRun times
1 hour per 10,000L of water per day during
swimming season
.
Reduce run time by
25
% or more once swimming
season has
finished.
oOxidiser level 0.5ppm Maximum
The oxidiser level can be tested using a standard pool chlorine test kit.
Note: A chlorine test kit reads the "Redox" or "oxidation-reduction potential (O
ORP
)” of the
water, which may be a combination of chlorine, oxygen and other oxidisers present in the
water.
4.2 Water Balance Standards
All swimming pools need to have the water balanced to protect the interior of your pool, bather
comfort and to maintain the effectiveness of any sanitiser.
opH 7.1 -7.4
oTotal Alkalinity 60-150ppm
oCalcium Hardness 170 -250ppm
IMPORTANT – HIGH Ph AFFECTS THE EFFICACY OF ANY SANITISER
e.g. Chlorine is only 3% effective at a pH of 8.0, compared
to 75% effective at a pH of 7.0.
– A high pH will also accelerate fiberglass gelcoat fading

9
e
enviroswim.com
5. INITIAL START UP - COMMISSIONING
5.1 New Pool Start Up or Pool Refills
Once the pool has been filled with water the Total Dissolved Solids (TDS) of the water needs to be raised to
1,000-1,500ppm. The ideal level for startup is 1,200ppm.
This is NOT A SALTWATER CHLORINATOR. Do not put excessive amounts of salt in your pool. There will be a
minimal amount of TDS in municipal water, and this varies from location to location.
Please ensure you have installed the Enviroswim ES3 as per the installation guide supplied.
1. Fill the pool with water
2. Check and adjust total alkalinity, pH and calcium hardness as per standard water balance.
oTotal Alkalinity 60 -150ppm
opH 7.0-7.2 (Fibreglass/Vinyl)
7.2-7.4 (Concrete)
oCalcium Hardness 170-250ppm
Note: Never add Calcium Hardness Increaser and Alkalinity Increaser on the same day.
3. Turn the ON/OFF switch to ON.
4. Turn the AUTO/OFF/MANUAL switch to MANUAL.
5. Turn the oxidiser output control to MAX.
oThe oxidiser display should read “15” at all times.
oIf the oxidiser display reads less than “15”, first check the TDS levels. If below 1,200ppm, add 5Kg
of salt per 10,000L to raise the TDS by approx. 500ppm.
6. Turn the Ioniser Control to 100% - for initial startup.
7. Run the system 1 hour per 1,000L to enable residual sanitisers to build up. E.g., A 50,000L pool should
be run continuously for 50 hours.
oCheck the copper levels. If you have obtained a minimum 0.2ppm copper reading, then you are
ready to switch to AUTO mode.
oIf you have not achieved a minimum 0.2ppm copper reading please run the system as is for an
additional 24 hours and check copper levels again. Repeat till the minimum copper level is
achieved.
oNOTE: PLEASE MEASURE AND ADJUST pH 8 HOURS BEFORE CHECKING COPPER LEVELS.
HIGH pH WILL MASK YOUR TRUE COPPER READING.
8. Once you have achieved the desired copper level, reduce the Ioniser control to “20-40%” as a starting
point.
9. Set your time clock to 1 hour of run time per 10,000L of water. These are our guideline operating
settings but will vary from pool to pool depending on the environment, bather load and pool interiors
and their quality.
10. Turn the AUTO/OFF/MANUAL switch to the AUTO position.
11. Enjoy swimming in your Enviroswim freshwater pool.
oDO NOT USE STABILISER
oDO NOT USE BROMINE COMPOUNDS
oDO NOT USE FLOCCULANTS
oDO NOT USE SODA ASH
oDO NOT USE GRANULAR CHLORINE
oDO NOT USE PUT UNDISSOLVED
CHEMICALS INTO THE POOL
oDO NOT USE ZEOLITE IN MEDIA FILTERS

10
e
enviroswim.com
5. INITIAL START UP – COMMISSIONING cont.
5.2 Salt Water Conversion - Startup
Saltwater pools have an extremely high Total Dissolved Solids (TDS), which is mainly pool salt. This can be
4,000ppm or in some cases significantly higher. The definition of fresh water is a TDS of less than 1,500ppm or
in some cases a salinity of less than 1,000ppm. These figures do vary around the world and each E.P.A body
may have slightly different variations.
The water in your pool is, in simple terms, the fuel for your sanitiser to operate as it is meant to.
The Enviroswim ES3 System needs pool water that is low in TDS (fresh water).
To convert a saltwater pool to be a freshwater pool you need to dilute the current TDS levels to the
Enviroswim’s freshwater parameters (1,000-1,500pp).
The best way to reduce TDS is to dilute your pool water with fresh water.
Please ensure you have installed the Enviroswim ES3 as per the installation guide.
1. Take a sample of your saltwater pool to a pool shop and ask them to test the total dissolved solids
(TDS).
2. Work out the percentage of water you will need to drain from your pool to lower the TDS to 1,000-
1,500ppm. E.g. If your TDS is 4,500 you will need to drain two thirds of the salty water and replace it
with fresh tap water (or other fresh water source).
3. It is recommended you check with a pool builder or Engineer before draining excessive amounts of
water from your swimming pool.
4. Now refer to instructions in previous section 5.1 for startup.
PLEASE SEE PREVIOUS PAGE FOR PRODUCTS THAT YOU SHOULD NOT USE IN YOUR POOL

11
e
enviroswim.com
6. MAINTENANCE
The Enviroswim ES3 system is very low maintenance. The Ionisers (copper/silver electrodes) are consumable
and require periodic replacement.
The ultrasonic chamber is maintenance free.
The oxidizer cell plates are self-cleaning. If you continually run a high pH, calcium scaling will occur on the
plates, and this will reduce the life expectancy of your plates.
6.1 Fuse
Fuse replacement: 240Volt, 5 amp, slow blow.
WARNING: There is a risk of electrical shock, fire and damage to the system if an incorrectly sized fuse is
installed.
6.2 Replacement of Ionisers (electrodes)
oThe Ionisers (copper/silver electrodes) are a consumable and will require periodic replacement.
oNOTE: ONLY USE GENUINE ENVIROSWIM ELECTRODES AND SPARE PARTS. ENVIROSWIM WILL NOT BE
HELD LIABLE FOR THE PERFORMANCE OR EFFECTIVENESS OF THE SYSTEM WHEN NON-GENUINE SPARE
PARTS AND CONSUMABLES ARE USED.
REPLACEMENT ELECTRODES CAN BE PURCHASED AT OUR ONLINE STORE AT THE BELOW LINK:
enviroswim.com/online-store
oThe life of the electrodes will depend on many
factors including, pool use, water balance, dirt and
other debris that are allowed to build up in the pool.
oThe electrodes should be replaced before
they
disappear completely.

12
e
enviroswim.com
6. MAINTENANCE Cont.
6.3 Oxidiser Cell Plates - Cleaning
oThe oxidiser cell plates are self-cleaning. If you need to clean them, it indicates issues in the pool water, which will
also need to be addressed. Cleaning the plates addresses the symptom, not the underlying issue. For example,
scaling on the plates generally indicates that the pH has been high (above 7.6) for extended periods, or the pool is
not grounded correctly.
oPlates should only be cleaned if there are signs of calcium build up on the plates or sensor, if your system is unable
to draw the 15 amps, or if the oxidiser output display is fluctuating. Cleaning them regularly shortens their life span.
We recommend resolving the underlying pool issue.
oRemedial action to remove scale from plates is by soaking plates only (not black plastic parts)
oClean plates by soaking in a 75/25% ratio water/hydrochloric acid solution. A plastic bucket or a 1.25 Litre soft
drink bottle with the top cut off is an ideal size for bathing the plates.
REMEMBER: Always add acid to Water. Never add water to chemicals.
oDo not leave the plates in the solution for extended periods of time, 3 minutes should be adequate.
oNever use metal objects to clean the plates, as this will damage the plate coating.
oLeaving calcium scale on your plates will shorten the life of the plates.
oNote: Only use genuine Enviroswim electrodes and spare parts. Enviroswim will not be held liable for the
performance or effectiveness of the system when non-genuine spare parts and consumables are used.
REPLACEMENT OXIDISER PLATES CAN BE PURCHASED AT OUR ONLINE STORE AT THE BELOW LINK:
enviroswim.com/online-store
Please check the following:
oTDS is within range 1.000 – 1,500ppm
oAll connections are correct and secure

13
e
enviroswim.com
6. MAINTENANCE Cont.
6.4 Copper Testing
oNOTE: HIGH pH will mask your copper test results.
oPlease ensure you pH is below 7.4 before doing a copper test.
oWe strongly advise that you use the test kit and instructions supplied with your Enviroswim system.
Note: The test kits have a two-year shelf life.
oCopper levels should read 0.2 - 0.4ppm
oIf taking a sample of pool water to a pool shop for testing, ensure pH is within set parameters for 24 hours prior.
oSome pool shop testing equipment can also give a false reading due to the silver in the water. When using the
supplied test kit ensure you look down the test vial when comparing to the colour chart.
oIf your copper reading is above 0.4 ppm turn the ioniser control to the 0 setting (OFF)
oOnly turn the ioniser control back ON once your copper level reaches 0.3 or lower
oIn normal operating circumstances your ioniser control should NOT be left in the 100% setting, unless you
need to build your copper levels up. Never leave on this setting for more than 7 days unless you are discussing
with a service technician.
oNOTE: Enviroswim will not be held responsible for high copper levels.
REPLACEMENT COPPER TEST KITS CAN BE PURCHASED AT OUR ONLINE STORE AT THE BELOW LINK
enviroswim.com/online-store

14
e
enviroswim.com
6. MAINTENANCE Cont.
6.5 Adjusting and Maintaining Water Balance
Water balance is applicable to all sanitised pools. This is an industry standard.
IMPORTANT – HIGH pH EFFECTS THE EFFICACY OF ANY SANITISER.
E.g. Chlorine is only 3% effective at a pH of 8.0, compared to 75% effective at a pH of 7.0.
Ideal Range
Measuring Adjusting
Alkalinity
60-150 ppm
Pool shop or test kit
Frequency: 3 Monthly
Lower by adding Hydrochloric acid
.
Raise by adding Sodium Bicarbonate
pH
7.1 – 7.4 Pool shop or test kit
Frequency: 7-
14 Days
Lower by adding Hydrochloric acid
Raise by adding Sodium Bicarbonate.
Water Hardness
170 – 250 ppm
Pool shop
Frequency: 3 Monthly
Lower by
diluting the pool water.
Raise by adding Calcium Chloride
Suggested testing frequencies are recommendations only for average use domestic pools. More frequent testing may
be required.
REMEMBER: Always add acid to Water. Never add water to acid.
6.6 Winterise Your Pool
Winterising your Enviroswim pool is an area where savings can be made. Once the water becomes too cold for bathing,
the daily run time of the pump/Enviroswim can be reduced to save on electricity.
The winterised run time depends on the pool’s surrounding environment as the pump will need to run long enough for
the filter to remove dirt and organic material that enter the pool. The residual copper & silver will take care of algae and
bacteria as they continue to work 24/7 regardless of the pump run time.
It is important to continue to balance water, including the pH (ensuring pH below 7.4, as a high pH will give you a false
copper reading) & check copper levels regularly during the winter.
Always run the oxidiser on maximum (15) during winterisation, whilst still checking O.R.P level periodically.
Vacuum the pool when required to avoid sediment building up which can stain and cause extra demand on the system.
Follow these guidelines and you will save money and have a great pool ready for the coming summer.
6.7 Pool Covers
We recommend that your Enviroswim System is turned off whilst the pool cover is being used. Still run your pump and
filtration system, run time will be reduced depending on the debris that enters your pool. The water balance still needs
to be checked periodically and adjusted if required.

15
e
enviroswim.com
7. TROUBLESHOOTING
Symptom
Possible Causes
Remedy
Blown Fuse
Enviroswim
not
running (no lights).
Pump still running,
plugged into control
box.
o
In-Rush Current from pool pump
oUndiluted chemicals added to pool or
skimmer basket
oShort circuit on Oxidiser Plates
oInternal electrical fault
o
Have pump checked
oTurn off power to control box. Replace
fuse and allow clean water to circulate
through the system before switching back
on.
oCheck for any visible debris
in wet cell and
remove them.
oContact Enviroswim
Copper
level too
low
o
Low conductivity (TDS)
oCopper/silver electrodes worn away
oPool or equipment leaking
oScale build up on electrodes
oSystem not running long enough
oIoniser setting too low
opH high
o
Increase TDS to 1,000-1,500ppm
oReplace with new electrode kit
oRepair leak
oClean rods – correct water balance
oIncrease run time
oIncrease ioniser setting
oAdjust pH to correct level
Excessive scale on
o
xidiser plates
o
pH too high
oHigh calcium content (water h
ardness)
in pool water
o
Adjust pH to correct level
oDilute Pool water with fresh water
Cloudy
water
o
Insufficient run time
oPoor water balance
oOxidiser plates have excessive scale
build up
oHigh bather load
o
Increase run time
oAdjust water to correct levels
oClean oxidiser plates
oRun pool on manual while swimming
Algae in
pool
o
Low copper levels
oPhosphates in water
oPoor water circulation
opH too high
o
Increase run time or Ioniser setting
oPhosphate treatment required
oCheck/c
lean filter, skimmer box, pump lint
basket. Ensure pump is operating correctly
and not at low speed if variable speed.
oAdjust pH to correct level

16
e
enviroswim.com
7. TROUBLESHOOTING cont.
The Enviroswim Control box has two vents that are located on under side of the control box at either end. From time to
time please ensure these are not blocked, and if they are please clean with a soft bristle brush e.g. Tooth brush
FOR FURTHER INFORMATION PLEASE VISIT
enviroswim.com
Fault Mode
Possible Causes
Remedy
Oxidiser Display
OL
Curr
ent no longer
being applied to
oxidiser plates
o
Excessive TDS greater than 2,500ppm
oUndiluted chemicals added to skimmer
oShort circuit across oxidiser
connections
or plates
o
Short Circuit across Ioniser connections
or electrodes
oDilute pool water to reduce TDS to below
1,500ppm
o
Allow clean water to circulate through the
system before switching back on.
oRemove short circuit
oRemove short circuit
Oxidiser Display
OF
oNo current applied to oxidiser plates
oCheck cable is plugged in correctly
oTurn oxidiser knob to max
Oxidiser Display
Pb
Curr
ent no longer
being applied to
oxidiser plates
o
Air in system
oInsufficient water flow
oCalcium build up on oxidiser plates or
sensor
o
Check cable is plugged in correctly
oCheck for leaks and prime pump
oCheck/c
lean filter, skimmer box, pump lint
basket. Ensure pump is operating
correctly.
o
Increase speed of Variable speed pump if
applicable
oClean Oxidiser Plates and sensor.
Oxidiser Display
tp
High temperature
within the ES3
control box.
o
Ventilation grills blocked
oVentilation fan failure
oElectronic temperature control issue
o
Clean grill, remove blockage
oCheck fan runs on startup
o
Check fan is running when display reduces
from ‘15’
oFan failure or temperature control issue
requires workshop repair.

17
e
enviroswim.com
8. SPECIFICATION, STANDARDS and WARRANTY
8.1 Specifications
oEnviroswim T.D.S. operating parameters: 1,000-1,500ppm
oEnviroswim recommended copper levels: 0.2-0.4ppm
oEnviroswim ES3 system sanitises swimming pools up to 100,000 litres
oEnviroswim run time – 1 hour per 10,000 litres (environment dependent)
oEnviroswim tested and complies with CISPR 14 Electromagnetic Compatibility.
oEnviroswim tested and complies with CE.
oElectrical requirements 220/240 volts ac 10 amp GPO.
oElectrical consumption of Enviroswim approx. 200 watts +/- 20% this is dependent of conductivity of the pool
water.
oPool pump outlet should not exceed 8amp, connected load.
8.2 Standards
Type
Standard
Description
Electrical
AS/NZS 3136
Electrical Equipment for Spa and Swimming Pools
EN 55014-2
EN 61000-3-2
EN 61000-3-3
Electromagnetic Compatibility
Chemical
Australian Pesticides and Veterinary Medicines Authority
Approval no. 58847
Efficacy
NATA Accredited
NSF/ANSI 50
Approved as hybrid system by the National Sanitization
Foundation (USA) Cert# 4D640-02
NZS5826
New Zealand Pool Water Quality Standards
HSO
NZ Drinking Water Standards 2005

18
e
enviroswim.com
8. SPECIFICATION, STANDARDS, and WARRANTY.
8.3 Warranty
The Enviroswim ES3 Control Box has a (2) year back to base warranty.
Please register your Enviroswim warranty at:
https://www.enviroswim.com/warranty-registration/
THIS EQUIPMENT HAS BEEN MANUFACTURED AND TESTED TO THE HIGHEST STANDARD AND AS SUCH
CARRIES THE FOLLOWING WARRANTY.
The Enviroswim ES3 Control Box will be repaired at no charge for a period of 2 years (24 Months) from the date of
purchase should it be found, after examination, that the failure has been caused by faulty workmanship or materials.
This is a back to base warranty. The Ioniser electrodes and oxidiser plates are consumable items and therefore will
need replacing from time to time depending on the size of swimming pool. The Ioniser rods and oxidiser plates do not
carry any warranty.
Harmful operating conditions beyond the control of the manufacturer including improper voltage, excessive water
pressure or any external condition that adversely affects the performance of the equipment renders this warranty null
and void.
Defective equipment must be returned to the manufacturer as soon as the purchaser becomes aware of the defect.
The manufacturer will not be responsible for any goods damaged in transit.
Should the equipment be found to be defective after inspection, it will be repaired or replaced free of charge. However,
if it is found that the terms of this warranty are not satisfied upon inspection of the equipment, then the usual charges of
the manufacturer for repair or replacement will be incurred by the customer, including all transport costs.
Any liability of the manufacturer pursuant to the Trade Practices Act 1974, as amended for a breach of a condition or
warranty shall be limited to replacing or acquiring the equipment (or part thereof) where the same has been supplied.
The maximum liability incurred by the manufacturer shall not in any case exceed the contract price for the equipment or
the product parts or components thereof claimed to be defective. Further, the manufacturer shall not be liable for any
loss, damage or delay directly or indirectly caused by any malfunction of or defect of or failure of the equipment other
than as expressly provided in this warranty.
Products sold by the manufacturer are designed for use with swimming pool water balanced in accordance with our
operating instructions in this manual.
The manufacturer will not be held liable for damage caused by, but not limited to, corrosion, scaling or misuse.
The following may void warranty:
– Installation is carried out incorrectly.
– Not using genuine Enviroswim parts.
– The Control Unit is not protected from the elements.
–The Control Unit is operated in a position/area with inadequate ventilation.
–Water has been allowed to enter the Control Unit or Cable connections.
– Insect infestation or penetration by dust, sand or other foreign particles inside the Control Unit.
– Damage beyond our control.
– Equipment that has been misused, neglected, damaged, repaired without authorisation or altered in any way.
When making a warranty claim, please email
info@enviroswim.com
and note the following information is to be provided
or claim may not be approved.
This information will expedite the processing of your claim.
– Control Unit Serial Number – Installation Date
– Your Full Name – Your Phone number
– Your Address Details – Details of the Issue
Enviroswim reserves the right to modify any model without notice.
Other manuals for ES-3
4
Table of contents
Popular Accessories manuals by other brands

Aqua Work
Aqua Work CFXB-C5 operating manual

Hytronik
Hytronik HC018V user manual

Bosch
Bosch rexroth RegisterControl ATEX MLC 14VRS operating instructions

Dickey-John
Dickey-John Daisy Chain Blockage manual

Anker
Anker PowerCore+ 19000 PD Welcome guide

AND
AND Explosion Protected Weighing Indicator AD-4403-FP ST... instruction manual