desired, turn on task by setting LIGHTS switch to the on (1)
position. TO clean ion emitter points, rotate POINT CLEANER knob
at each air outlet clockwise to the stop slightly (approximately one
turn) and release.
The time required to neutralize a static charge on an item in the
air stream depends on fan speed. Setting a higher fan speed reduces
time required to neutralize a static charge.
When the E-003 blower is used in an electronic assembly area, the
ionized air stream should cover as much of the working area as
possible. The constant flow of ionized air will prevent items such
as work surfaces, tools, materials and components from developing
a static charge. Charged items introduced into a work area will be
neutralized and will remain neutral while keeping in the ionized air
stream.
The E-003 overhead blower has been designed for minimal
maintenance. The only regular maintenance suggested consists of
emitter point cleaning, ion balance checking and ion output
checking. Emitter point cleaning takes only moments with the point
cleaners. The E-003 also contains a balancing circuit that is
inherently self balancing. This circuit compensates for emitter point
wear, line voltage fluctuations and variations in air velocity.
Scheduled checking of ion output and balance should be considered
to assure quality audit requirements.