ESD EPPC-T10 User manual

EPPC-T10
Embedded 64-bit PowerPC® T1014
Single Board Computer
Hardware Manual
to Product I.2007.02
EPPC-T10 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 Page 1 of 37
esd electronics gmbh
Vahrenwalder Str. 207 • 30165 Hannover • German
http://www.esd.eu
Phone: +49 (0) 511 3 72 98-0 • Fax: +49 (0) 511 3 72 98-68

N O T E
The information in this document has been carefully checked and is belie ed to be entirely reliable.
esd ele troni s makes no warranty of any kind with regard to the material in this document, and
assumes no responsibility for any errors that may appear in this document. In particular
descriptions and technical data specified in this document may not be constituted to be guaranteed
product features in any legal sense.
esd ele troni s reser es the right to make changes without notice to this, or any of its products, to
impro e reliability, performance or design.
All rights to this documentation are reser ed by esd ele troni s. Distribution to third parties, and
reproduction of this document in any form, whole or in part, are subject to esd ele troni s's
written appro al.
© 2019 esd electronics gmbh, Hanno er
esd electronics gmbh
Vahrenwalder Str. 207
30165 Hanno er
Germany
Phone: +49-511-372 98-0
Fax: +49-511-372 98-68
E-Mail: [email protected]
Internet: www.esd.eu
This manual contains important information and instructions on safe and efficient
handling of the EPPC-T10. Carefully read this manual before commencing any work and
follow the instructions.
The manual is a product component, please retain it for future use.
Trademark Notices
Altera® is a registered trademark of Intel Corporation or its subsidiaries in the U.S. and/or other countries..
QorIQ® and NXP are registered trademarks of NXP B.V.
EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
PCI Express® and PCIe® are registered trademarks of PCI-SIG.
Linux® is the registered trademark of Linus Tor alds in the United States and/or other countries.
OS-9® is a registered trademark of RadiSys Corporation.
PowerPC® is a registered trademark of IBM in the United States and/or other countries.
All other trademarks, product names, company names or company logos used in this manual are reser ed by their
respecti e owners.
Page 2 of 37 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 EPPC-T10

Do ument file: I:\Texte\Doku\MANUALS\Embedded\EPPC-T10\EPPC-T10-Manual_en_11.odt
Date of print: 2019-05-07
Do ument type
number: DOC0800
Hardware version: PCB Re .1.1
Do ument History
The changes in the document listed below affect changes in the hardware as well as changes in
the description of the facts, only.
Rev. Chapter Changes versus previous version Date
1.0 - First English manual 2017-10-17
1.1
- Note on Conformity under Safety Instructions inserted
2019-05-07
1. Block circuit diagram corrected → 32 Kbit EEPROM
2.7 Description of EEPROM changed
2.9, 2.10 Note on cabling inserted
8. Chapter numbers re ised
8.1, 8.2 Note on cabling inserted
9. New chapter: “Conformity”
Technical details are subject to change without further notice.
EPPC-T10 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 Page 3 of 37

Classifi ation of Warning Messages and Safety Instru tions
This manual contains noticeable descriptions, warning messages and safety instructions, which
you must follow to a oid personal injuries or death and property damage.
This is the safety alert symbol.
It is used to alert you to potential personal injury hazards. Obey all safety messages
and instructions that follow this symbol to a oid possible injury or death.
DANGER, WARNING, CAUTION
Depending on the hazard le el the signal words DANGER, WARNING or CAUTION are used to
highlight safety instructions and warning messages. These messages may also include a warning
relating to property damage.
DANGER
Danger statements indicate a hazardous situation which, if not a oided, will result in
death or serious injury.
WARNING
Warning statements indicate a hazardous situation that, if not a oided, could result in
death or serious injury.
CAUTION
Caution statements indicate a hazardous situation that, if not a oided, could result in
minor or moderate injury.
NOTICE
Notice statements are used to notify people on hazards that could result in things other than
personal injury, like property damage.
NOTICE
This NOTICE statement indicates that the de ice contains components sensiti e to
electrostatic discharge.
NOTICE
This NOTICE statement contains the general mandatory sign and gi es information that
must be heeded and complied with for a safe use.
INFORMATION
INFORMATION
Notes to point out something important or useful.
Page 4 of 37 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 EPPC-T10

Safety Instru tions
● When working with the EPPC-T10 follow the instructions below and read the manual carefully to
protect yourself from injury and the EPPC-T10 from damage.
● Do not use damaged or defecti e cables to connect the EPPC-T10.
● In case of damages to the de ice, which might affect safety, appropriate and immediate measures
must be taken, that exclude an endangerment of persons and domestic animals and property.
● Current circuits which are connected to the de ice ha e to be sufficiently protected against
hazardous oltage (SELV according to EN 60950-1).
● The EPPC-T10 may only be dri en by power supply current circuits, that are contact protected.
A power supply, that pro ides a safety extra-low oltage (SELV) according to EN 60950-1, complies
with this conditions.
● Do not open the housing of the EPPC-T10 except for ser ice issues (see page 20 ff.).
● The EPPC-T10 has to be securely installed before commissioning.
● The permitted operating position is specified as shown (Figure: 3). Other operating positions are not
allowed.
●Ne er let liquids get inside the EPPC-T10. Otherwise, electric shocks or short circuits may result.
● Protect the EPPC-T10 from dust, moisture and steam.
● Protect the EPPC-T10 from shocks and ibrations.
● The EPPC-T10 may become warm during normal use. Always allow adequate entilation around the
EPPC-T10 and use care when handling.
● Do not operate the EPPC-T10 adjacent to heat sources and do not expose it to unnecessary thermal
radiation. Ensure an ambient temperature as specified in the technical data.
DANGER
Hazardous Voltage - Risk of ele tri sho k due to unintentional contact with uninsulated li e
parts with high oltages inside of the system into which the EPPC-T10 is to be integrated.
→
→
All current circuits which are connected to the de ice ha e to be sufficiently protected
against hazardous oltage (SELV according to EN 60950-1) before you start with the
installation.
Ensure the absence of oltage before starting any electrical work
DANGER
Risk of personal injury due to explosion or leakage of the battery!
Improper usage of the battery such as o erheating, short-circuiting or mechanical damage
may cause an explosion or leakage.
→
→
→
→
Do not replace the battery by an incorrect type.
Do not recharge the battery.
Insert the battery properly, with the +/- terminals correctly oriented.
Dispose used batteries according to the national instructions.
NOTICE
Ele trostati dis harges may ause damage to ele troni omponents.
To a oid this discharge the static electricity from your body before you open the EPPC-
T10.
Qualified Personnel
This documentation is directed exclusi ely towards personnel qualified in control and automation
engineering. The installation and commissioning of the product may only be carried out by qualified
personnel, which is authorized to put de ices, systems and electric circuits into operation according to
the applicable national standards of safety engineering.
EPPC-T10 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 Page 5 of 37

Conformity
The EPPC-T10 is an industrial product and meets the demands of the EU regulations and EMC
standards printed in the conformity declaration at the end of this manual.
Warning: In a residential, commercial or light industrial en ironment the EPPC-T10 may cause radio
interferences in which case the user may be required to take adequate measures.
Data Safety
This de ice is equipped with an Ethernet or other interface which is suitable to establish a connection to
data networks. Depending on the software used on the de ice, these interfaces may allow attackers to
compromise normal function, get illegal access or cause damage.
esd does not take responsibility for any damage caused by the de ice if operated at any networks. It is
the responsibility of the de ice's user to take care that necessary safety precautions for the de ice's
network interface are in place.
Intended Use
The intended use of the EPPC-T10 is the operation as controller for machine control (factory
automation).
The guarantee gi en by esd does not co er damages which result from improper use, usage not in
accordance with regulations or disregard of safety instructions and warnings.
● The EPPC-T10 is intended for operation in a control cabinet.
● The operation of the EPPC-T10 in hazardous areas, or areas exposed to potentially explosi e
materials is not permitted.
● The operation of the EPPC-T10 for medical purposes is prohibited.
Servi e Note
The EPPC-T10 does not contain any parts that require maintenance by the user. The EPPC-T10 does
not require any manual configuration of the hardware, except the change of battery or the configuration
ia jumper or DIP switches. Unauthorized inter ention in the de ice oids warranty claims.
Disposal
De ices which ha e become defecti e in the long run ha e to be disposed in an appropriate way or
ha e to be returned to the manufacturer for proper disposal. Please, make a contribution to
en ironmental protection.
Typographi al Conventions
Throughout this manual the following typographical con entions are used to distinguish technical terms.
Convention Example
File and path names /dev/null or <stdio.h>
Function names open()
Programming constants NULL
Programming data types uint32_t
Variable names Count
Number Representation
All numbers in this document are base 10 unless designated otherwise. Hexadecimal numbers ha e a prefix
of 0x. For example, 42 is represented as 0x2A in hexadecimal .
Abbreviations
CPU Central Processing Unit
HW Hardware
I/O Input/Output
n.a. not applicable
OS Operating System
SDK Software De elopment Kit
Page 6 of 37 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 EPPC-T10

Table of ontents
Safety Instructions...........................................................................................................................5
1. O er iew...................................................................................................................................... 9
2. Technical Data ...........................................................................................................................11
2.1 General technical Data.........................................................................................................11
2.2 Power Supply.......................................................................................................................11
2.3 CPU Kernel..........................................................................................................................11
2.4 Memory - Interface...............................................................................................................12
2.5 Real Time Clock (RTC)........................................................................................................12
2.6 Boot – ROM......................................................................................................................... 12
2.7 EEPROM............................................................................................................................. 12
2.8 Connectors.......................................................................................................................... 13
2.8.1 Connectors in the EPPC-T10 Enclosure.....................................................................13
2.8.2 Connectors on the Main Board (internal).....................................................................13
2.9 Ethernet Interfaces...............................................................................................................14
2.10 Serial Interface................................................................................................................... 14
2.11 Terminal Interface...............................................................................................................14
2.12 USB - Host Interface..........................................................................................................15
2.13 SATA Interface...................................................................................................................15
2.14 Monitoring Circuitry............................................................................................................15
3. PCB View with Connectors.........................................................................................................16
3.1 PCB Top Layer..................................................................................................................... 16
4. EPPC-T10 View.........................................................................................................................17
4.1 Operating position................................................................................................................17
4.2 Front Side with LEDs, Terminal Interface and SD-Card Slot................................................18
4.2.1 LEDs in the Front Panel..............................................................................................18
4.3 Front View Upper Side with Serial Interface.........................................................................19
4.4 Front View Bottom Side with Ethernet, USB and 24V-Power Supply...................................19
4.4.1 Ethernet LEDs.............................................................................................................19
5. Hardware Installation and Change of Battery.............................................................................20
5.1 Installation............................................................................................................................ 20
5.2 Demounting......................................................................................................................... 21
5.3 microSD Card......................................................................................................................21
5.4 Change of Battery ...............................................................................................................22
5.5 Prepare Configuration (DIP-Switches, JP800).....................................................................23
5.5.1 Configuration ia DIP Switch.......................................................................................24
5.5.2 Configuration ia Jumper JP 800 ................................................................................24
5.6 Software Support.................................................................................................................25
5.7 Firmware License.................................................................................................................25
6. Software..................................................................................................................................... 26
6.1 Configuration and Console Access......................................................................................26
6.1.1 Start Message.............................................................................................................26
6.1.2 Firmware Configuration...............................................................................................27
6.2 Update of the Bootloader.....................................................................................................28
6.3 Operating System and Dri ers.............................................................................................28
7. CPU............................................................................................................................................ 29
7.1 User configuration ia GPIO register ...................................................................................29
7.2 Watchdog.............................................................................................................................29
8. Connector Assignments..............................................................................................................30
8.1 Serial 1 - RS232 (X711).......................................................................................................30
8.2 Ethernet ETH1 - 3 (X1300, X1400, X1500)..........................................................................31
EPPC-T10 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 Page 7 of 37

8.3 USB (X1200)........................................................................................................................32
8.4 Terminal Interface (X450).....................................................................................................32
8.5 24V Power Supply Voltage (X100) ......................................................................................33
8.5.1 Conductor Connection/Conductor Cross Sections......................................................33
8.6 Internal Connectors..............................................................................................................34
8.6.1 SATA 0 (X2000)...........................................................................................................34
8.6.2 SATA- Power 0 (X2001)..............................................................................................34
8.6.3 Backup-Battery and Front LEDs, JTAG.......................................................................35
8.6.3.1 Backup-Battery and Front LEDs (X180) ...............................................................35
8.6.3.2 JTAG CPU (X800) ................................................................................................35
9. Conformity..................................................................................................................................36
10. Order Information..................................................................................................................... 37
Page 8 of 37 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 EPPC-T10

Overview
1. Overview
Figure 1: Block circuit diagram
The EPPC-T10 a single board computer with 3 independent Ethernet interfaces.
The embedded NXP® QorIQ® T1014 with 1.2 GHz features one 64-bit e5500 Power Architecture®
processor core with high performance data path acceleration architecture (DPAA) and network
peripheral interfaces.
The local memory bus is 64 bits wide plus 8 bits ECC with an o erall capacity of 512 Mbyte.
16 Mbyte SPI Flash for boot loader and 32 Kbit I²C EEPROM for U-Boot en ironment offer non-
olatile memory spaces.
The EPPC-T10 features a second 16 Mbyte 'fallback' SPI Flash, used for system reco ery if a
system crash occurs during a firmware update. Alternati ely it can be used for application software.
The EPPC-T10 is equipped with 3 independent Gigabit Ethernet interfaces accessible at the front
panel, which gi e an excellent base for EtherCAT® applications.
For connection of the RS-232 interface an easily accessible RJ45 connector is pro ided.
Additionally a Terminal is accessible ia mini-USB connector for configuration of the system.
The USB host port supports USB 2.0 high-speed.
An RTC with battery backup is equipped on the EPPC-T10.
The Flash memory carries the standard boot program “Das U-Boot” and enables the EPPC-T10 to
boot arious operating systems from on-board Flash, network, USB, microSDTM card or optional
SSD. A BSP is a ailable for Linux®. Others on request.
The esd EtherCAT Master Stack is a ailable for se eral operating systems.
EPPC-T10 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 Page 9 of 37
Memory Bus 64Bit + ECC Kanal 1
NXP
Power PC
T1014
1200MHz
PCIe Mini
Slot
2 x 16Mbyte
Serial Flash
RGMII
GB Ethernet
Phy
Transformer
RJ45
RGMII
GB Ethernet
Phy
Transformer
RJ45
USB 2.0
SPI
Serial
I2C
RS232
I2C
SPI-Boot Order
A/D
Con erter
Main Power
Core Power
Batt Power
CPU Temp.
T4T3
Temp. Sensors
SGMII
GB Ethernet
Phy
Transformer
RJ45
USB-A
RTC
Serial
EEPROM
32KBit
PCIe 1x
IRQ
Power Supply Voltage
Under Voltage Threshold Value
RJ45
SDHC
microSD-Card
Connector
RS232
T5
DDR3 RAM
1GBit x16
SATA
SATA 2.0
optional
SSD
FTDI
RS232 / USB
Con erter
miniUSB
Socket
DDR3 RAM
1GBit x16
DDR3 RAM
1GBit x16
DDR3 RAM
1GBit x16
DDR3 RAM
1GBit x16
T2T1

Overview
Customized options are a ailable for customized series production in reasonable quantities.
Please contact our sales team for detailed information.
Customized options are for example:
- CPU Type
The EPPC-T10 is also a ailable with the power sa ing dual-core QorlQ CPU T1022 or with the
quad-core QorlQ CPU T1042 on request.
- Memory
The memory can be extended with larger DDR3 RAM and Flash.
An additional serial or parallel MRAM memory, that is suitable for capturing continuous logging
data, is a ailable on request.
- SSD
A built-in solid state disc can be equipped.
- BSPs
Please ask for OS-9®, QNX®, VxWorks® or other BSPs.
- PCI Express
A PCIe® slot for de elopment can be equipped. The case size can be customized as needed.
The PCIe slot can be used for example for a customized PMC-Add-on. Please ask for further
information.
- Ethernet
An additional Ethernet interface (4th interface) can be equipped.
Page 10 of 37 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 EPPC-T10

Te hni al Data
2. Te hni al Data
2.1 General te hni al Data
Temperature range Operation: 0°C ... +55°C
Storage: -40°C ... +70°C
Transport: -40°C ... +70°C
Humidity Operation: 5% ... 90%, non-condensing
Storage: 5% ... 90%, non-condensing
Protection class IP20
Form factor/
Dimensions
124 mm x 31 mm x 160 mm (length x width x height)
with top hat rail mounting clamp
Weight ca. 400 g
2.2 Power Supply
Power supply oltage 16V … 32 V DC
(Power fail signalling from < 20V)
Power consumption Typical 12 W
maximum 20 W
Protecti e circuits Re erse oltage protection ia an ideal diode,
Protection against short-circuit of the internal oltages
2.3 CPU Kernel
CPU NXP T1014NSN7MQB
CPU Specification 1.200 MHz CPU-Clock
800 MHz RAM-Clock
0-105 °C operating junction temperature
Cache 32 KByte L1 instruction-cache and 32 KByte data-cache per core
256 KByte L2 cache per core
256 KByte L3 cache
Interfaces Integrated DDR3 RAM controller
Integrated Ethernet controller
Integrated DUART
Integrated I²C interfaces
Core e5500 Core with double-precision Floating Point Unit
De elopment Connector 2x8 Pin connector, 2.54 mm pitch, with IEEE1149.1 (JTAG)
With signals for:
- Manufacturing test (Boundary Scan)
- Software-Debugging (i.e. ABATRON Debugger)
- Initial programming of the serial Boot Flash (U-Boot)
EPPC-T10 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 Page 11 of 37

Te hni al Data
2.4 Memory - Interfa e
Size 512Mbyte
Technology Double data rate SDRAM type 3
Data rate (theoretical
maximum)
800 MHz RAM clock, 1600 x 64 MBit/s
Interface 1 x 64 Bit + ECC consisting of 4 x16 de ices + 1 x16 de ice for ECC
2.5 Real Time Clo k (RTC)
Type Epson RX8035
Connection I2C bus
Accuracy -5 ppm at Tamb = 25 °C (< 13 s/month)
Battery type Lithium manganese dioxide battery, coin cell 3 V, battery type CR2032
Buffering Battery CR2032, at least 5 years battery life at 25°C
Maintenance / Ser ice The battery can be easily changed. The battery holder is located inside
the enclosure, see page 22. For a change of the battery without data
loss, a storage capacitor, connected with the RTC, allows a change of
the battery without interruption of supply oltage within 15 seconds.
2.6 Boot – ROM
Size 16 MByte
Type Serial NOR Flash
Connection Serial Peripheral Interface min. 50 MHz data rate
Data retention 100 000 Programming/erase cycles, 20 years data retention
Content Boot Sequenzer
Preboot Loader
Bootloader Firmware (U-Boot)
Fail Sa e Mechanism Second Flash with „Fallback“ firmware. Switchable ia jumper.
2.7 EEPROM
Size - 32 Kbit I2C EEPROM for U-Boot en ironment
Internal use only: - 32 Kbit I2C EEPROM for Bootstrapping,
- 4 Kbit I2C EEPROM for SPD info DDR RAM
Type Serial CMOS EEPROM
Connection I2C Bus
Data retention 1 000 000 Programming/erase cycles, 20 years data retention
Operating mode Fast (400KHz) I2C protocol
Content - Serial number of the board
- MAC addresses
- U-Boot en ironment
- SPD data of the DDR-RAM
Page 12 of 37 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 EPPC-T10

Te hni al Data
2.8 Conne tors
2.8.1 Conne tors in the EPPC-T10 En losure
Name Label Fun tion Type
X711 RS-232 Serial 1 (RS-232) RJ45 socket without LEDs
X100 24 V Power supply oltage Phoenix-Contact MC1,5/3-GF-3,81
X1300 ETH1 Ethernet 1 RJ45 socket with integrated LEDs
X1400 ETH2 Ethernet 2 RJ45 socket with integrated LEDs
X1600 ETH3 Ethernet 3 RJ45 socket with integrated LEDs
X1200 USB USB-Host USB socket type-A
X450 Terminal Serial 0 Mini-USB connector type-B
X700 SD-Card SD-Card slot MOLEX_5027740891
2.8.2 Conne tors on the Main Board (internal)
Name Fun tion Type
X2000 SATA Interface Molex 67800-8001 or similar
X2001 SATA Power FCI 76384-304LF
Connectors for installation and test purposes only:
X800 JTAG Interface 2 x 8-pole plug connector 2.54 mm pitch
X2410 BOUNDARY Scan / JTAG 2 x 5-pole plug connector 2.54 mm pitch
EPPC-T10 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 Page 13 of 37

Te hni al Data
2.9 Ethernet Interfa es
Number 3
Standard IEEE 802.3, 10Base-T, 100Base-TX, 1000Base-T
Bit rate 10/100/1000 MBit/s
Controller Integrated in the CPU
Electrical isolation Transformer, integrated in the RJ45 socket
Connector RJ45 sockets with integrated Link and Acti ity LEDs
NOTICE
Cables of category CAT5e or higher ha e to be used to grant the function in networks with
1000 Mbit/s. esd grants the EC conformity of the product if the wiring is carried out with
shielded twisted pair cables of category CAT5e or higher.
2.10 Serial Interfa e
Number 1 asynchronous serial interface
Controller integrated in CPU - 16550 compatible
Bit rate Value range: 9600 Baud ... 115200 Baud
Default setting: 9600 Baud, 8 Bit, No Parity 1 Stop-Bit
Physical interface RS232 with RxD, TxD, RTS, CTS
Software Standard operating system dri er
Connector Serial 1: RJ-45 connector
NOTICE
For the serial interface shielded cables ha e to be used.
esd grants the EC conformity of the product if the wiring is carried out with a shielded
cable with a maximum wire length of 30 m.
2.11 Terminal Interfa e
Number 1 asynchronous serial interface
Controller integrated in CPU - 16550 compatible
Bit rate Value range: 9600 Baud ... 115200 Baud
Default setting: 115200 Baud, 8 Bit, No Parity 1 Stop-Bit
Physical interface TTL with RxD, TxD, con erted with FTDI to USB 2.0
USB bit rate Max. 480 MBit/s
Software FTDI dri er, see “Configuration and Console Access”on page 26
Connector Mini-USB connector type-B
Page 14 of 37 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 EPPC-T10

Te hni al Data
2.12 USB - Host Interfa e
Number 1
Standard USB specification Re . 2.0
Bit rate Max. 480 MBit/s
Topology Host controller integrated in CPU
Max. current per port @5V 500 mA, short-circuit protected
Software support - OHCI-Host controller- and de ice dri er for the U-Boot
Connector USB socket type-A
2.13 SATA Interfa e
Number 1
Standard SATA Specification Re . 2.5
Type Standard SATA data plug connector plus one connector for the
supply oltage of the SATA de ices
Topology Connected directly with the SATA port of the Host CPU
Power supply oltage 3,3 V with max. 1A
5 V with max. 0,75A
2.14 Monitoring Cir uitry
Temperature monitoring 4 x TMP100 + 1 x ADT7461 connected with the I2C Bus of the CPU to
monitor the ambient temperature and the thermal diode of the CPU
Voltage monitoring By means of 12-bit ADC which is connected ia I²C to the CPU and
possibly required circuits for signal conditioning.
Monitoring of
- Voltage supply
- Battery oltage (RTC)
- 3.3 V, 5 V, core oltages
EPPC-T10 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 Page 15 of 37

PCB View with Conne tors
3. PCB View with Conne tors
3.1 PCB Top Layer
Figure 2: PCB top iew
NOTICE
Read chapter “Hardware Installation and Change of Battery” on page 20, before you start
with the installation of the hardware!
See also page 30 for signal assignment of the connectors.
Page 16 of 37 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 EPPC-T10

EPPC-T10 View
4. EPPC-T10 View
4.1 Operating position
Figure 3: EPPC-T10 mounted on the mounting hat rail
See also page 30 for signal assignment of the connectors.
NOTICE
Read chapter “Hardware Installation and Change of Battery” on page 20, before you start
with the installation of the hardware!
EPPC-T10 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 Page 17 of 37

EPPC-T10 View
4.2 Front Side with LEDs, Terminal Interfa e and SD-Card Slot
Figure 4: LEDs and connectors in the front panel
4.2.1 LEDs in the Front Panel
LED Colour Meaning (LED on)
LED name in
schematic
diagram
Term Green Traffic on Terminal interface LED450
PWR Green Power supply oltage on LED190
RUN Green CPU-RUN LED191
BATT Red Low battery LED192
O er Temp Red Temperature error, o ertemperature LED193
Table 1: Display function when LED on
Page 18 of 37 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 EPPC-T10

EPPC-T10 View
4.3 Front View Upper Side with Serial Interfa e
Figure 5: Front panel on upper side
4.4 Front View Bottom Side with Ethernet, USB and 24V-Power Supply
Figure 6: Front panel on bottom side
4.4.1 Ethernet LEDs
The Ethernet LEDs are integrated in the RJ45 sockets of the Ethernet interfaces (ETH1, ETH2 or
ETH3).
LED Colour Display fun tion Meaning
A tivity green flashing Ethernet acti ity, data are transmitted
Link yellow on Ethernet connection established,
Ethernet bit rate: 10/100/1000 Mbit/s
Table 2: Description of RJ45-LEDs
EPPC-T10 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 Page 19 of 37

Hardware Installation and Change of Battery
5. Hardware Installation and Change of Battery
NOTICE
Read the safety instru tions at the beginning of this do ument arefully, before
you start with the hardware installation!
DANGER
Hazardous Voltage - Risk of ele tri sho k due to unintentional contact with
uninsulated li e parts with high oltages inside of the system into which the EPPC-T10 is
to be integrated.
→ Disconnect all hazardous oltages (mains oltage) before opening the system.
→ Ensure the absence of oltage before starting any electrical work.
→ Co er or block off adjacent li e parts.
NOTICE
Ele trostati dis harges may ause damage to ele troni omponents.
→
→
To a oid this, discharge the static electricity from your body before you touch the
EPPC-T10.
Furthermore, you should pre ent your clothes from touching the EPPC-T10, because
your clothes might be electrostatically charged as well.
5.1 Installation
Pro edure:
1. Discharge your body as described abo e.
2. If necessary configure the hardware (dip switches or jumper) before you start with the
installation. See chapter “Prepare Configuration (DIP-Switches, JP800)” page 23.
3. Make sure that no risk arises from the system into which the EPPC-T10 shall be inserted.
DANGER
Hazardous Voltage
Risk of ele tri sho k due to unintentional contact with uninsulated li e parts with
high oltages inside of the system into which the EPPC-T10 is to be integrated.
→
→
→
→
Disconnect all hazardous oltages (mains oltage) before opening the system.
If the system does not ha e a flexible mains cable, but is directly connected to
mains, disconnect the power supply ia the safety fuse and make sure that the fuse
cannot switch on again unintentionally (i.e. with caution label).
Ensure the absence of oltage before starting any electrical work
Co er or block off adjacent li e parts.
4. Mount the EPPC-T10 on the carrier rail.
5. Connect the interfaces (Ethernet, Serial, USB, 24 V power supply oltage).
6. Connect the system to mains again (mains connector or safety fuse).
7. Switch on the system and the peripheral de ices.
8. End of hardware installation.
9. Set the interface properties in your operating system. Refer to the documentation of the
operating system.
Page 20 of 37 Hardware Manual • Doc. No.: I.2007.21 / Re . 1.1 EPPC-T10
This manual suits for next models
1
Table of contents
Other ESD Motherboard manuals