This manual describes the installation of the FlatFix Fusion mounting system for at roofs (for solar panels in landscape
setup).
Read the manual carefully so that you are fully aware of the entire content. Follow the instructions in the manual carefully.
Always carry out the actions in the correct order.
Store the manual in a safe and dry location. If you lose the manual, you may always request a copy from Esdec BV
or download it from www.esdec.com. Where there is a reference to the construction plan, we also refer to the FlatFix
Calculator that allows you to generate a construction plan.
01
Rev. 10.09.19 MANUAL FOR FLATFIX FUSION MOUNTING SYSTEM FOR FLAT ROOFS
1. Introduction
2. General installation conditions
General
A failure to adhere to the guidelines stated in this document and/or in the construction plan may lead to all warranty and
product liability claims lapsing.
The details, comments and recommendations in this document are binding and must be checked to ensure they are
complete and up-to-date. Esdec BV retains the right to revise this document without notication.
Stability and condition of the roof
The roof must be in good condition and strong enough to bear the weight of the solar panels, incl. associated materials,
ballast, wind and snow load. Check the stability of the roof/structure and where necessary employ a builder to correct it.
Make sure the load reserve of the roof is not exceeded either locally or in its entirety.
Insulation / roofing material
The continual pressure loading capacity (point load) of the insulation and the roong material must be checked thoroughly
and found to be sound before installation. The suitability of the roof supports combined with the roong material must be
checked and found to be sound, and if necessary or desirable extra roof supports must be tted at the required locations. In
case of doubt, employ a roofer.
Safety warnings
• FlatFix Fusion mounting systems must be tted as standard by qualied technical personnel (at least two skilled
people).
• The addition or omission of parts may have a detrimental effect on the function of the system and is strongly
discouraged!
• Before placing the solar panels, the roof must be clean, dry, at and free of algae and the like.
• Avoid tting in high winds and a wet, slippery roof surface.
• Fitting of the FlatFix Fusion mounting system may only take place at temperatures between 5º and 40ºC (due to the
tments of the plastic parts).
• Always work on a roof using fall protection and safety nets and edge protection where necessary.
• Wear shoes with reinforced toecaps and sturdy anti-slip soles.
• Always wear the proper protective clothing when carrying out the work.
• Always use lifting aids / hoist systems when moving the material (solar panels, etc.).
• Always place a ladder on a sound and stable surface.
• Always place the ladder at an angle of around 75º and ensure it sticks out about 1 metre above the roof edge.
• If possible, fasten the top of the ladder with a rope or strap.
• Preferably work in accordance with the “Working safely on roofs” handbook.
Range of application of FlatFix Fusion
• Wind zone (1 to 3 with the exception of coastal areas).
• Roof height (3-12m) If your roof is higher, contact your supplier.
• Type of roong material: Concrete, bitumen / EPDM / PVC / TPO.
• Roof pitch: maximum 3º. Between 3º and 7º (between 2° and 7º with PVC), the base plates must be sealed. For a roof
pitch of over 7º, contact your supplier.
• Setup: Landscape mounting.
• Maximum solar panel dimensions: length 1170–1310 mm, 1475–1615 mm, 1550–1690 mm, 1655–1795 mm, 1830–
1970 mm, 1940–2080 mm, 980–1050 mm, thickness 25–50 mm. (See table on Page 02)