Esteam Cleaning Systems E1050 User manual

ESTEAM CLEANING SYSTEMS
500 MODELS
OWNER’S MANUAL
Congratulations on your selection of a new E1050 soil extractor built in
Canada by “Esteam Cleaning Systems.” Our goal has been to produce the
best high performance line of carpet cleaning equipment on the market
today. Reading your owners manual will help to achieve maximum benefit
from your purchase.

1
TABLE OF CONTENTS
Page No.
Introduction on the E1050 2
Specifications 2
Maintenance 3
Safety Information 3
Operating Instructions 4
Trouble Shooting 7
Schematic 10
Warranty Registration 30
Warranty 31

2
INTRODUCTION
Be it a small residential job or a large commercial contract, Esteam Cleaning Systems
industrial carpet cleaning extractors are right for your needs. The E1000 deliver the
ultimate in power, capacity, durability, and performance. The 500 PSI models are a
light weight portable electronic truckmount, and is one of the most powerful soil
extractors on the market.
Only the highest quality components go into our equipment, to deliver you strength and
reliability in a long life high performance machine. All Esteam Cleaning Systems
equipment housings are made of high impact, unbreakable polyethylene.
The E1050 incorporates a unique single 3 stage vacuum producing 150 inches of water
lift or 185 inches of water lift with optional dual 3 stage vacuum. To compliment the
vacuum lift the E1050 comes standard with a 500 PSI PumpTec pump. No cleaning job
is too large for the E1050.
SPECIFICATIONS
E1050 ( 110v&220v )
E1050
E1050-20
E1050-05
E1050-20-05
E1050-10
E1050-20-10
ELECTRICAL
Amps
Volts
One cord
14 amps
115 volts or 220 volts
Two cords
14 amps per cord
115 volts or 220 volts
Two cords
14 amps per cord
115 volts or 220 volts
VACUUM MOTOR
Cfm’s
Vacuum lift
Single 3 stage (LRG-PLASTIC)
94
150”
2-3 stage High Performance
101
185”
Single 3 stage (LRG-PLASTIC)
94
150”
PUMP
Pump Motor
500 psi Plunger
1/4 HP A/C
500 psi Plunger
1/4 HP A/C
500 psi Plunger
1/4 HP A/C
INTERNAL HEATER
N/A
N/A
1850 watt / 200ºF
SOLUTION TANK
(Clean water)
10.5 gallons (40 litres)
10.5 gallons (40 litres)
10.5 gallons (40 litres)
RECOVERY TANK
10.5 gallons (40 litres)
10.5 gallons (40 litres)
10.5 gallons (40 litres)
LENGHT
26 inches (66 cm)
26 inches (66 cm)
26 inches (66 cm)
WIDTH
17 inches (43 cm)
17 inches (43 cm)
17 inches (43 cm)
HEIGHT
34 inches (86 cm)
34 inches (86 cm)
34 inches (86 cm)
WEIGHT
110 lbs (49.8 kgs)
115 lbs (52 kgs)
115 lbs (52 kgs)

3
MAINTENANCE
DAILY:
- Clean high water level float screen inside the recovery tank.
- Ensure high level float ball is working properly.
- Rinse out recovery tank after use.
- Clean dirt and obstructions from the (recovery tank) drain valve rubber
gaskets to prevent premature wear.
- Rinse out pump with clean water at conclusion of work day.
- Clean poly housing with mild soap and water.
- Check machine fuse.
MONTHLY:
- Clean air inlet and check exhaust port.
- Check to make sure cooling fan is operating properly.
- Check 1 ½ dump valve seal.
YEARLY:
- We recommend that your unit be inspected by a qualified service technician
once a year.
PREVENTATIVE MAINTENANCE:
-Never store this unit in a place where there is a possibility of the temperature
dropping below 00C (320F).
SAFETY INFORMATION
1. Prior to inspection or repair of this machine, disconnect all electrical cords
rendering the machine powerless. Failure to do so could result in serious or fatal
injury.
2. Inspect unit daily for worn or damaged components. E.g. frayed cord, loose plug,
or a plug with missing ground pin, etc.
3. This unit should only be operated when in an upright position on a level surface.
4. Do not operate unit unless it is properly grounded in a 3 pin grounded outlets.
Never bend or remove ground pin from plugs.
5. Ensure filters and screens are free from lint or dirt.
6. Do not run unit if vacuum motor or pump are wet. Allow sufficient time for motor
to dry before plugging unit in.

4
7. Do not use solvent based cleaning products in this extractor.
8. Keep air inlets and exhaust ports free from obstructions. Blocked air inlets or
exhaust ports can cause the unit to overheat.
9. Do not use solution or recovery tanks for storing hoses, cords or accessories.
10. When using electrical equipment around water it is important to wear rubber
soled shoes and keep machine properly grounded at all times. Failure to do so
could result in a fatal electric shock.
OPERATING INSTRUCTIONS
1. Insert electrical cords into 3 pin grounded outlets.
2. We recommend the use of a liquid defoamer, to prevent the machine from
prematurely shutting off due to excess foam in the recovery tank. Turn on
vacuum and pour approximately ¼ cup of Esteam Liquid Defoamer into the end
of the vacuum hose.
3. 500 PSI Plunger pump priming instructions:
- Fill fresh water tank
- Turn on vacuum
- Always release the pressure by depressing the prime valve prior to turning on
the pump, to release head pressure and prevent blowing fuse or over amping
the pump motor
- Turn on pump
- Cover vacuum barb on recovery tank
- Pull prime valve trigger for about 30 seconds
- Shut off pump and vacuum
- Connect hoses for cleaning and machine is ready to use.
4. To adjust pump pressure: Turn pressure regulator (located at the lower front of
machine) clockwise to increase pressure; counter-clockwise to decrease
pressure.
TO USE YOUR E1050 HEATER:
A. Hook the wand solution hose to the quick connect of your machine.
B. Plug the heater power cord into a wall that is on a separate circuit form the other
cord.
C. Turn the heater switch on.
D. When the red light goes out, solution is heated and ready to use.

5
OPERATING INSTRUCTIONS (CONTINUED)
WARNING: If your heater does not work DO NOT attempt to repair it yourself, call your
distributor for repair procedures. Using solvents in heaters can be hazardous and will
void your warranty. Allowing heaters to freeze will crack the heater cartridge and will
also void your warranty.
DANGER: No solvents of any type may be used in this system at any time. The use of
solvents is extremely hazardous resulting in possible fire and/or explosion.
5. Connect vacuum and solution hoses to the carpet cleaning wand.
6. Proceed to clean carpets.
7. When the recovery tank becomes full, vacuum will automatically stop extracting.
When vacuum stops extracting it will make a distinctive high pitched noise as all
the air flow will be cut off. At this time switch unit off. Drain the recovery tank by
pulling up on drain valve on front of machine.
NOTE: Ensure that the high water level float screen inside the recovery tank is free
from any obstructions. Be sure to close drain valve before resuming cleaning.
8. To empty solution tank remove vacuum hose from wand. Turn on vacuum and
extract solution from solution tank into recovery tank, then drain recovery tank.
NOTE: Do not completely submerge end of vacuum hose into solution. Allow some air
to enter end of vacuum hose with liquid.
9. When the job is completed empty and rinse out the solution and recovery tanks.
Allow vacuum to run for 3 to 5 minutes. This will eliminate all moisture from
vacuum assuring long vacuum life.
WARNING: When using electrical equipment around water it is important to wear
rubber soled shoes and keep machine properly grounded at all times. Failure to do so
could result in electric shock.

6

7
TROUBLE SHOOTING
WARNING: Prior to inspection or repair of this machine, disconnect all
electrical cords rendering the machine powerless. Failure to do so could
result in serious or fatal injury.
PROBLEM CAUSE SOLUTION
1. Entire unit will not 1. Unit not plugged in 1. Connect unit to 3 pin
operate grounded outlets
2. Blown fuse on machine 2. Check machine fuses
and replace if necessary
3. Blown fuse or breaker for 3. Check fuse panel for
plug in outlet blown fuse
4. Loose wiring 4. See dealer
2. 500 PSI Plunger 1. Switch not turned on 1. Turn on switch
pump will not run
2. Broken switch 2. See dealer
3. Loose wiring 3. See dealer
4. Pump motor defective 4. See dealer
3. Vacuum will not run 1. Switch not turned on 1. Turn on switch
2. Blown fuse 2. Replace fuse
3. Broken switch 3. See dealer
4. Loose wiring 4. See dealer
5. Blocked rotor 5. See dealer
4. 500 PSI Plunger 1. Out of solution 1. Fill solution tank with
pump runs but does solution
not pump solution
2. Pump inlet screen plugged 2. Clean inlet screen
3. Pump was not properly 3. Prime pump using
primed priming hose
4. Kink in solution hose 4. Remove kink
5. Plugged jet or quick connect 5. Remove blockage
6. Internal (inside machine) or 6. See dealer
external solution line damaged
and leaking

8
TROUBLE SHOOTING (CONTINUED)
PROBLEM CAUSE SOLUTION
5. 500 PSI Plunger 1. Pressure regulator valve 1. Adjust pressure using
pump runs but has out of adjustment regulator located at the
loss of pressure front of the machine
2. Partial kink in solution hose 2. Remove kink
3. Partial blockage in solution 3. Remove blockage
hose
4. Jet orifice opening on clean- 4. Total jet opening for 500
ing wand is too large PSI pump should be .02
5. Pressure regulator valve 5. See dealer
components wearing out
6. Internal pump components 6. See dealer
wearing out
6. Vacuum operates 1. Recovery tank full 1. Drain recovery tank
but has poor or no
suction 2 Vacuum hose plugged 2. Locate and remove
blockage
3. Wand plugged 3. Locate and remove
blockage
4. Exhaust port blocked 4. Locate and remove
blockage
5. High level float stuck in off 5. Turn vacuum off and tap
position top of float screen cage
6. Front drain valve left open 6. Close recovery tank
after draining recovery tank drain valve on front of
machine
7. Vacuum prema- 1. Excess foam in recovery 1. Add defoamer to
turely stops extracting tank recovery tank
2. Lint or dirt on automatic 2. Clean auto shut off float
shut off float screen screen
3. Defective float ball 3. Replace float screen
cage

9
TROUBLE SHOOTING (CONTINUED)
PROBLEM CAUSE SOLUTION
8. Machine spits water 1. High level float not working 1. Check auto shut off float
out of exhaust port properly cage and ball for proper
operation
9. Machine blowing 1. Damaged (leaking) recov- 1. Immediately shut unit
excessive amounts of ery tank fittings down. Bring unit to a
water out of exhaust dealer for service
ports
10. Water accumulate- 1. Inside solution line leaking 1. Immediately shut unit
ing in bottom electrical down. Bring unit to a
component area dealer for service
2. Pump leaking 2. Immediately shut unit
down. Bring unit to a
dealer for service
3. Solution or recovery tank 3. Immediately shut unit
leaking from above down. Bring to a dealer
for service
11. Heater won’t work. 1. Heater cord not plugged in. Connect cord to 3 Pin
(Separate) outlet
2. Faulty Thermostat or See dealer
Thermo cut-out
12. Water not hot 1. Check Jet size on wand or
enough upholstery tool. Do not
exceed .02 orfice size for
maximum heat transfer
2. Do not use cold water in
solution tank. Must use
hot tap water for maximum
heat transfer

10
E1050 ( P. 1 )

11
E1050 ( P. 2 )

12
E1050

13
REF
PART NO.
DESCRIPTION
NOTES:
1
305-230
Switch, Rocker 20 Amp
2
315-015
Cord, 25' Black 14/3 SJTW-A
3
315-040
Cord, Fan - Muffin
4A
333-010
Fan, Muffin 6"- 110V
E1050-05
4B
333-015
Fan, Muffin 6"- 220V
E1050-20-05
5
335-005
Strain Relief, 12 Gauge
6
340-155
Circuit Breaker, 5 Amp
7
350-005
Strap Velcro
8
355-120
Vacuum, 3 STG (LRG-PLASTIC)
9
355-225
Vac spacer, 3/8 OD x 2-1/4 ID
10
360-015
1000 Psi Pressure Gauge
11
360-111
Hour Meter (Optional)
12
400-005
Hex Nut, 1/4 x 20 SS
Not shown
13
400-010
Hex Nut, 1/4 x 20 Zinc
14
400-055
Lock nut, 10-24 Nylon Zinc
15
400-115
Locknut, 1/4 x 20 Nylon SS
16
400-130
Locknut, 10 x 24 Nylon SS
17
400-135
Lock nut, 1/4 x 20 Nylon zinc
18
400-165
Locknut, 1/2"
19
405-010
Bolt, 1/4 x 1 SS
20
405-020
Bolt, 1/4 x 1-1/4 SS
21
405-050
Bolt, 1/4 x 3-1/2 Stove Zinc
22
405-615
CS, 1/4 x 1/2 SS (Hex HD)
23
405-620
CS, 1/4 x 3/4 SS (Hex HD)
24
410-005
MS, 1/4 x 1 Phil SS Flat/H
25
410-058
SMS, 4 x 1/4 Pan Phil SS
26
410-125
SMS, 8 x 5/8 Pan RB SS
27
410-160
MS, 10-24 x 3/4 Pan PH SS
28
410-165
MS, 10-24 x 1 Pan Slot SS
29
410-175
MS, 10-24 x 2 1/2 RH RB Zinc
30
410-205
MS, 10-32 x 1/2 Panphil SS
31
415-020
LW, 1/4 Zinc
32
415-115
FW, 10 SS
33
410-120
FW, 1/4 Zinc
34
415-125
FW, 1/4 SS
35
415-155
FW, 1/2 SS (Stand/Max OD)
36
415-156
FW, 1/2 SS
37
415-305
FNDW, 1/4 SS
38
420-105
Rivet, Al/St #66
39
420-151
Rivet, Fullysealed #68
40
425-005
Clamp, #8
41
435-015
Handle, Brass/Chrome
42
440-006
S.S. Hinge 2" x 2"
43
445-015
Latch, Machine
44
445-020
Latch, Striker
45
455-075
Caster, 4" Swivel
46
455-052
Wheel Cap Dome
47
455-057
Wheel 8” grey Black Hub
48
465-035
Bracket, 500 PSI Motor
49
465-065
Brace, Tank

14
50
470-051
Axel
51
475-010
Gasket, Rubber - 1 1/2" Dump Valve
52
475-030
Gasket, Lid 3/8"
53
475-040
Gasket, 1/8 x 1"
54
475-225
Gasket , Vac 7”
55
485-000
Copper 3/8"
56
495-021C
Rec Tank & Lid
57
495-035
Base
58
495-040
Sol Tank
59A
512-542
Pump 500 PSI & M110 Motor
E1050
59B
512-545
Pump 500 PSI
59C
512-551
Motor Model M110 (110V)
E1050
59D
512-552
Motor Model M110 (220V)
E1050-20
60
530-025
Regulator, MV500
61
545-100
Dump Valve, 1 1/2"
62
551-029
Prime Valve
63
555-072
Close nipple, 1/4”
64
555-095
Comp. Fitting 90 3/8 x 1/4 MPT
65
555-110
Comp. Fitting, 3/8 Comp x 1/4 FPT
66
555-186
Elbow 45, 3/8 Street Extruded
67
555-206
Elbow 90, 1/4 FPT Extruded
68
555-208
Elbow 90, 1/4 Street Extruded
69
555-272
Hex Nipple, 1/4" (Long)
70
555-325
Hose Barb 90, 1/2 Barb x 1/4 MPT
71
555-370
Hose Barb, 1/2 Barb x 1/4 MPT
72
555-372
Hose Barb, 1/2 Barb x 3/8 MPT
73
555-422
Long Nipple 1/4 x 1 1/2"
74
555-424
Long Nipple, 1/4 x 2 1/2"
75
555-454
Plug, 3/8 MPT Hex Head
76
555-636
Tee, 1/4" Street Extruded
77
560-030
Screen, Acorn
78
560-116
Strainer, Inline Barbed 1/2
79
560-330
Guard, Finger, 6" Muffin Fan
80
572-125
Pulse Hose, 3/8"
81
572-155
Polyspring Hose, 1/2"
82
580-010
Q.C. 1/4" Fem (Closed)
83
581-055
Crimp Ftng, 3/8" Pulse Hose 3/8 MPT SVL
84
581-065
Crimp Ftng, 3/8" Pulse Hose 1/4 MPT SVL
85
585-025
Spin Fitting, 1-1/2
86
590-010
PVC Elbow, 1-1/4” 90, S x S
87
590-020
PVC ELB 1 1/2" 90, S x FIPT
88
590-405
PVC Hose Barb 1 1/2" x MPT
89
590-415
PVC Adpt 1 1/2", S x MPT
90
595-005
ABS Pipe, 1 1/2"
91
595-110
PVC Pipe, 1 1/4"
92
597-010
Float Screen Cage
93
597-061
Adpt (RM) 30 Degree
94
845-010
Baffle, S/S
95
845-030
Switch Plate
96
845-040
Solution Tank Cover

15
E1050 2-3 STAGE VAC

16
E1050 2-3 STAGE VAC
REF
PART NO.
DESCRIPTION
NOTES:
1
305-230
Switch, Rocker 20 Amp
2
315-015
Cord, 25' Black 14/3 SJTW-A
3
315-040
Cord, Fan - Muffin
4A
333-010
Fan, Muffin 6"- 110V
E1050-05
4B
333-015
Fan, Muffin 6"- 220V
E1050-20-05
5
335-005
Strain Relief, 12 Gauge
6
340-155
Circuit Breaker, 5 Amp
7
350-005
Strap Velcro
8A
355-411
Vac. 2-3 Stage 110v (c/w 355-405)
8B
355-510
Vac. 2-3 Stage 220v (c/w Flat Cap)
9
355-210
Bracket, Vac 2-3 Stage
10
355-405
Vac Cap, Straight
11
355-230
Vac bolt Spacer, 1-1/8”
12
360-015
1000 Psi Pressure Gauge
13
360-111
Hour Meter (Optional)
14
400-005
Hex Nut, 1/4 x 20 SS
15
400-055
Lock nut, 10-24 Nylon Zinc
16
400-115
Locknut, 1/4 x 20 Nylon SS
17
400-130
Locknut, 10 x 24 Nylon SS
18
400-135
Lock nut, 1/4 x 20 Nylon zinc
19
400-165
Locknut, 1/2"
20
405-010
Bolt, 1/4 x 1 SS
21
405-020
Bolt, 1/4 x 1-1/4 SS
22
405-045
Bolt, 1/4 x 3 Stove Zinc
23
405-615
CS, 1/4 x 1/2 SS (Hex HD)
24
405-620
CS, 1/4 x 3/4 SS (Hex HD)
25
410-005
MS, 1/4 x 1 Phil SS Flat/H
26
410-125
SMS, 8 x 5/8 Pan RB SS
27
410-160
MS, 10-24 x 3/4 Pan PH SS
28
410-165
MS, 10-24 x 1 Pan Slot SS
29
410-175
MS, 10-24 x 2 1/2 RH RB Zinc
30
410-205
MS, 10-32 x 1/2 Panphil SS
31
410-225
SMS, 10 x 1/2 Pan RB Zinc
32
415-020
LW, 1/4 Zinc
33
415-115
FW, 10 SS
34
410-120
FW, 1/4 Zinc
35
415-125
FW, 1/4 SS
36
415-155
FW, 1/2 SS (Stand/Max OD)
37
415-156
FW, 1/2 SS
38
415-305
FNDW, 1/4 SS
39
420-055
Rivet, Al/Al #46
40
420-105
Rivet, Al/St #66
41
420-151
Rivet, Fullysealed #68
42
425-005
Clamp, #8
43
425-010
Clamp, #20
44
435-015
Handle, Brass/Chrome
45
440-006
S.S. Hinge 2" x 2"

17
46
445-015
Latch, Machine
47
445-020
Latch, Striker
48
455-005
Caster, 4" Swivel
49
455-052
Wheel Cap Dome
50
455-057
Wheel, 8" Grey/Black Hub
51
465-035
Bracket, 500 PSI motor
52
465-065
Brace, Tank
53
470-051
Axel
54
475-010
Gasket, Rubber - 1 1/2" Dump Valve
55
475-030
Gasket, Lid 3/8"
56
475-040
Gasket, 1/8 x 1"
57
485-000
Copper 3/8"
58
495-021C
Rec Tank & Lid
59
495-035
Base
60
495-040
Sol Tank
61
512-542
Pump, 500 PSI & M110 Motor (110v)
E1050-05
62
512-545
Pump, 500 PSI
63A
512-551
Motor Model M110(110v)
E1050-05
63B
512-552
Motor Model M110(220v)
E1050-20-05
64
530-025
Regulator, MV500
65
545-100
Dump Valve, 1 1/2"
66
551-029
Prime Valve
67
555-072
Close Nipple 1/4”
68
555-095
Comp. Fitting 90 3/8 x 1/4 MPT
69
555-110
Comp. Fitting, 3/8 Comp x 1/4 MPT
70
555-182
Elbow 45, 1/4 FPT Extruded
71
555-206
Elbow 90, 1/4 FPT Extruded
72
555-212
Elbow 90, 3/8 FPT
73
555-214
Elbow 90, 3/8 Street Extruded
74
555-272
Hex Nipple, 1/4" (Long)
75
555-274
Hex Nipple, 3/8" x 1-1/2”(Long)
76
555-370
Hose Barb, 1/2 Barb x 1/4 MPT
77
555-372
Hose Barb, 1/2 Barb x 3/8 MPT
78
555-424
Long Nipple, 1/4 x 2 1/2"
79
555-454
Plug, 3/8 MPT Hex Head
80
555-636
Tee, 1/4" Street Extruded
81
560-030
Screen, Acorn
82
560-116
Strainer, Inline Barbed 1/2"
83
560-330
Guard, Finger, 6" Muffin Fan
84
570-010
Vac Hose, 1 1/2 Wire Reinforced
85
572-125
Pulse Hose, 3/8"
86
572-155
Poly spring Hose, 1/2"
87
580-010
Q.C. 1/4" Fem (Closed)
88
581-055
Crimp Ftng, 3/8" Pulse Hose 3/8 MPT SVL
89
581-065
Crimp Ftng, 3/8" Pulse Hose 1/4 MPT SVL
90
590-020
PVC ELB 1 1/2" 90, S x FIPT
91
590-205
PVC, Wall Fitting, 1 1/2
92
590-405
PVC Hose Barb 1 1/2" x MPT
93
590-415
PVC Adpt 1 1/2", S x MPT
94
595-005
ABS Pipe, 1 1/2"
95
595-110
PVC Pipe, 1 1/4"

18
96
597-010
Float Screen Cage
97
597-061
Adpt (RM) 30 Degree
98
845-010
Baffle, S/S
99
845-030
Switch Plate
100
845-040
Solution Tank Cover

19
E1050 HEATER MATE
This manual suits for next models
5
Table of contents
Other Esteam Cleaning Systems Vacuum Cleaner manuals