WARNING: RISK OF ELECTRIC SHOCK! Power must be off when you perform these procedures.
AVERTISSEMENT: RISQUE DE DÉCHARGE ÉLÉCTRIQUE! L'alimentation doit étre éteinte avant d'exécuter cette procédure.
WARNING: RISK OF ELECTRIC SHOCK! Rack-Mount units must be connected to a protective earthing conductor.
AVERTISSEMENT: RISQUE DE DÉCHARGE ÉLÉCTRIQUE! Les appareils montés en rack doivent être connectés à conducteur de terre de protection.
How to...
Response Opto-Splitter
...reverse power connector...wire DIN rail power...mount to DIN rail ...mount to equipment rack
Remove screws and open cover
Remove screws securing power
connector and support bracket
and blank plate
Switch power connector and support
bracket with blank plate
Replace cover and screws
Tighten screws and washers
Align clip nuts with mounting holes
(where required)
- Strip length: 6 mm (1/4 in)
- Wire size: 0.5 - 4 mm2
(22 - 12 AWG)
- Torque: Max 0.5 Nm
(4.4 lb-in)
Wire the 3 position terminal
connector with positive,
negative, and ground wires in
the appropriate terminals.
Hook top of unit over the
upper DIN rail edge (1)
Depress until bottom clip on
unit seats completely (2)
To remove, use a small
screwdriver to release the
orange retaining clips on top
and bottom of the unit
Ensure DIN rail is securely
mounted
1
2
1
2