Euphonix ML530 User manual

Euphonix is Avid. Learn more at www.avid.com
ML530
Mic-Line Interface
Installation Manual
Document Revision: A
Part Number: 840-11310-01
Release Date: August 2010

Euphonix is Avid. Learn more at www.avid.com
Regulatory and Safety Notices
FCC Notice
Part 15 of the Federal Communication Commission Rules and Regulations has established Radio
Frequency (RF) emission limits to provide an interference free radio frequency spectrum. Many
electronic devices produce RF energy incidental to their intended purpose.
These rules place electronic equipment into two classes, A and B, depending on the intended use.
Class A devices are those that may be expected to be installed in a business or commercial environment.
Class B devices are those that may be expected to be installed in a home or residential environment. The
FCC requires devices in both classes to be labeled with the interference likelihood and additional
operating instructions. The rating label on the equipment will show which class the product is (A or B).
Class A product will not have an FCC logo. Class B equipment will have an FCC logo. The information
statements differ on the two classes.
Class A Equipment
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at personal expense.

Euphonix is Avid. Learn more at www.avid.com
Modifications
The FCC requires the user to be notified that any changes or modifications made to Avid hardware that
are not expressly approved by Avid Technology may void the user’s authority to operate the equipment.
Cables
Connections to Avid hardware must be made with shielded cables with metallic RFI/EMI connector
hoods in order to maintain compliance with FCC Rules and Regulations.
PRODUCTS WITH MULTIPLE POWER INPUTS:
WARNING: Each power input is intended to be connected to a separate branch circuit. Risk of high
leakage exists if multiple inputs are connected to a single source and protective earth is not present. A
QUALIFIED SERVICE PERSON shall verify that each socket-outlet from which the equipment is to be
powered provides a connection to the building protective earth. If any do not provide this connection,
the QUALIFIED SERVICE PERSON shall arrange for the installation of a PROTECTIVE EARTHING
CONDUCTOR from the separate protective earthing terminal to the protective earth wire in the building.
Canadian ICES-003
Class A Equipment
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecté toutes les exigences du Règlement sur le matériel
brouilleur du Canada.

Euphonix is Avid. Learn more at www.avid.com
European Union Declaration of Conformity
Declaration of conformity
Konformitätserklärung
Déclaration de conformité
Declaración de Confomidad
Verklaring de overeenstemming
Dichiarazione di conformità
We/Wir/ Nous/WIJ/Noi:
Avid Technology
1925 Andover Street
Tewksbury, MA, 01876 USA
European Contact: Nearest Avid Sales and Service Office or
Avid Technology International B.V.
Sandyford Industrial Estate
Unit 38, Carmanhall Road
Dublin 18, Ireland
declare under our sole responsibility that the product,
erklären, in alleniniger Verantwortung,daß dieses Produkt,
déclarons sous notre seule responsabilité que le produit,

Euphonix is Avid. Learn more at www.avid.com
declaramos, bajo nuestra sola responsabilidad, que el producto,
verklaren onder onze verantwoordelijkheid, dat het product,
dichiariamo sotto nostra unica responsabilità, che il prodotto,
Product Name(s) : Mic-Line Interface
Model Number(s): ML530
Product Options: This declaration covers all options for the above product(s).
to which this declaration relates is in conformity with the following standard(s) or other normative
documents.
auf das sich diese Erklärung bezieht, mit der/den folgenden Norm(en) oder Richtlinie(n)
übereinstimmt.
auquel se réfère cette déclaration est conforme à la (aux) norme(s) ou au(x) document(s)
normatif(s).
al que se refiere esta declaración es conforme a la(s) norma(s) u otro(s) documento(s)
normativo(s).
waarnaar deze verklaring verwijst, aan de volende norm(en) of richtlijn(en) beantwoordt.
a cui si riferisce questa dichiarazione è conforme alla/e seguente/i norma/o documento/i
normativo/i.
The requirements of the European Council:
Safety: Directive 2006/95/EC
EN 60065:2002 /A1:2006
EMC: Directive 2004/108/EC
EN 55103-1:1996
EN 55103-2:1996

Euphonix is Avid. Learn more at www.avid.com
LED Safety Notices
Avid hardware might contain LED or Laser devices for communication use. These devices are compliant
with the requirements for Class 1 LED and Laser Products and are safe in the intended use. In normal
operation the output of these laser devices does not exceed the exposure limit of the eye and cannot
cause harm.
Standard to which conformity is declared: (IEC 60825-1)
Optical connections are located on the rear panel and are typically labeled “Optical” or “SPDIF/ADAT.”
The exact location of optical connections is identified more clearly elsewhere in the documentation for
the Avid hardware device.
Disposal of Waste Equipment by Users in the
European Union

Euphonix is Avid. Learn more at www.avid.com
Rack-mount Requirements
The following rack-mount requirements are listed below:
• Elevated Operating Ambient — If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment might be greater than room ambient. Therefore, consider installing the
equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the
manufacturer.
• Reduced Air Flow — Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised. Do not block vents.
• Mechanical Loading — Mounting of the equipment in the rack should be such that a hazardous condition is
not achieved due to uneven mechanical loading.
• Circuit Overloading — Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
• Reliable earthing — Reliable earthing of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the branch circuit (for
example, use of power strips).

Euphonix is Avid. Learn more at www.avid.com
Lithium Battery Replacement
If a battery is supplied in this Avid product it must only be replaced by qualified personnel. Contact Avid
Customer Support for assistance.
WARNING
Danger of explosion if battery is incorrectly replaced. Replace with only the same or equivalent type
recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s
instructions.
ADVARSEL!
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af
samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
ADVARSEL!
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av
apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
VARNING
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som
rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan
suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.

Euphonix ML530 Mic-Line Interface Operation Manual
v
Table of Contents
List of Figures ....................................................................................................................... vi
List of Tables ........................................................................................................................ vii
Overview...............................................................................................................12
Features .................................................................................................................12
Applications ..........................................................................................................12
Front Panel ............................................................................................................13
Rear Panel ...........................................................................................................14
Specifications......................................................................................................15
User Reference....................................................................................................16
Standard Configuration ...........................................................................16
Optional Input Patch................................................................................19
Elco 38 Input/Output Pinout ...............................................................................21

Euphonix ML530 Mic-Line Interface Operation Manual
vi
List of Figures
1 ML530 Front Panel .............................................................................................................13
2 Front Panel Channel Status LEDs ......................................................................................13
3 ML530 Rear Panel ............................................................................................................ 14
4 ML530 Standard Cable Diagram ......................................................................................16
5 ML530 Standard Configuration ........................................................................................18
6 Input Patch Cable Diagram ...............................................................................................19
7 Input Patch Configuration .................................................................................................20
5-1 ML530 In 1/In 2 Pinout: Elco 38 Socket ..........................................................................21
5-2 ML530 Out 1/Out 2 Pinout: Elco 38 Socket .....................................................................21

Euphonix ML530 Mic-Line Interface Operation Manual
vii
List of Tables
1 Performance Specifications ........................................................................................... 15
2 Environmental and Power Specifications ...................................................................... 15
3 ML530 Physical Dimensions ......................................................................................... 16
4 ML530 Standard Cable Specification ............................................................................ 17
5 Input Patch Cable Specifications ................................................................................... 19

Euphonix ML530 Mic-Line Interface Operation Manual
12
Overview
The ML530 Mic-Line Interface is a 24-channel, digitally controlled analog preamplifier.
The ML530 is controlled by the SC253i Interface Pilot, which is controlled from the
System 5 console surface. The ML530 is packaged in a 2RU enclosure.
Features
The ML530 provides gain over a range of -12 to +72 dB in 0.5 dB increments for each
channel. The ML530 also features a high-pass filter, HiZ/LowZ switch, and phantom
power.
Front panel LEDs provide status information for all features so the operator can quickly
view the status of each input channel. Red front panel LEDs indicate signal clipping,
mute, impedance, and phantom power activation. Green LEDs indicate signal presence,
activation of the high-pass filter, and pad attenuator.
Redundant power is supported by purchasing an additional power module (Euphonix
part number: 964-06692-01).
Applications
Used in conjunction with the Euphonix AM713 analog to MADI converter, the ML530
provides multiple variable gain inputs for the System 5 or Max Air. Additional ML530s
can be added if more than 24 channels of variable gain inputs are desired.

Euphonix ML530 Mic-Line Interface Operation Manual
13
Front Panel
Figure 1 ML530 Front Panel
Power Switch: The power switch, on the lower right, turns the unit on/off.
Status LEDs: Eight LEDs provide status information for each of the 24 channels:
•Clip: Signal clipping (red)
•Mute: Channel muted (red)
•HiZ: High impedance (red)
•48V: Phantom power (red)
•Sig: signal present (green)
•HPF: High-pass filter (green)
•Phase: Phase invert (green)
•Pad: 12 dB attenuation (green)
Figure 2 Front Panel Channel Status LEDs
Since the ML530 is digitally controlled via software, the power switch is the only front
panel control.
MIC LINE INTERFACE
ML
530
12345678
910111213141516
17 18 19 20 21 22 23 24
Clip Mute LowZ 48V
Sig HPF Phase Pad

Euphonix ML530 Mic-Line Interface Operation Manual
14
Rear Panel
Figure 3 ML530 Rear Panel
Inputs (38-pin Elco): 24 inputs are provided on two 38-pin ELCO connectors. The lev-
el of all signals input at these ports can be boosted or attenuated. In standard configu-
ration, the input cable is configured by customer. Elco connectors and pins are
provided. See Elco 38 Input/Output Pinout on page 17.
Outputs (38-pin Elco): 24 outputs are provided on two 38-pin Elco connectors. The
supplied output cables fan out to two sets of 12 male XLRs for connection to the
AM713 Analog to MADI converter. See Elco 38 Input/Output Pinout on page 17.
Control (DB-15): Input for digital control signal from PC253i Digital Pilot. Signal for-
mat is Euphonix TCC bi-directional serial protocol. All switching and gain controls are
communicated via this connector.
AC Line In (IEC) and Fuse Tray: The power connector accepts standard IEC power
cords. 90–250 VAC 110, 220, or 240 VAC, 50/60 Hz can be applied at this connector.
CONTROL
OUTPUTS INPUTS
1-12
13-24
ML530

Euphonix ML530 Mic-Line Interface Operation Manual
15
Specifications
Table 1 Performance Specifications
Table 2 Environmental and Power Specifications
Gain Range -12 dB to 72 dB in 0.5 dB increments
Phantom Power +48 V ±2% (Switched per channel)
Maximum Input Level 41 dB (Pad inserted, unity gain, @1 kHz, @1% THD+N)
Differential Input Impedance 200 kΩ (Hi Z, Pad off, +48V off)
200 kΩ (Hi Z, Pad on, +48V off)
12.7 kΩ (Hi Z, Pad on, +48V on)
12.7 kΩ (Hi Z, Pad off, +48V on)
1.5 kΩ (Lo Z, Pad off, +48V off)
1.5 kΩ (Lo Z, Pad on, +48V off)
1.4 kΩ (Lo Z, Pad on, +48V on)
1.4 kΩ (Lo Z, Pad off, +48V on)
Maximum Output Level 29 dB (@1 kHz, @1% THD+N)
Output Impedance 100 Ω
Frequency Response 10 Hz – 60 kHz (-0.5 dB @ unity gain)
10 Hz – 50 kHz (-0.5 dB @ 30 dB gain)
10 Hz – 40 kHz (-0.5 dB @ 66 dB gain)
Gain Accuracy ±0.15 dB (@1 kHz)
Distortion (THD+N) 0.004% (@ 1 kHz @ 0 dB gain with
+13.5 dB applied, 22 kHz filtered)
< 0.02% (20 Hz – 20 kHz @ 13.5 dB 80 kHz filtered)
Equivalent Input Noise (EIN) -127 dB (@66 dB gain, 22 Hz – 22 kHz filtered, Low Z mode, 150 Ω source)
Common Mode Rejection (CMR) >50 dB (10 Hz – 20 kHz)
Phase Linearity ±10° (25 Hz – 20 kHz)
High-pass Filter 80 Hz 18 dB/octave switched per channel
Phase Invert 180° switched per channel
Operating Temperature 5–35°C
Power Requirements 100–240 VAC, 50/60Hz
Power Consumption 1 A

Euphonix ML530 Mic-Line Interface Operation Manual
16
Table 3 ML530 Physical Dimensions
NOTE: Leave about six inches behind the ML530 for cable connections.
User Reference
Standard Configuration
Figure 4 ML530 Standard Cable Diagram
Height 3.5 inches
Width 19 inches
Depth 18.6 inches
Weight 17 lb
4
21
B
recommended locations
3
AM713
ADigital Core
B
Use relative locations to
determine cable lengths
4
ML530
Control Room
B
Machine Room
A
Elco crimp pins and hoods for
user inputs are supplied in
accessory cable kits. Input
cabling supplied by customer
5,6
1 2
44

Euphonix ML530 Mic-Line Interface Operation Manual
17
The standard lengths specified in Table 4 and Table 5 are supplied so the mic-line in-
terface can be located in the control room. Custom lengths are available and cable kits
must be ordered separately.
Table 4 ML530 Standard Cable Specification
Cable Qty Description 10M Part # 20M Part# Length
Accessory cable kits by special order 936-07083-01 936-07155-01
11MADI Output: RG59 75 Ω coax 032-07230-00 032-07306-00
21
AES/EBU Sync:
one male XLR <> one female XLR 030-07085-01 030-07153-01
3 1 TCC Control from 253i Interface Pilot 030-06983-01 030-06985-01
42
ML530 Analog Out
one Elco 38 <> twelve male XLR 030-7108-01 .5 m
5 2 Elco 38-Pin Connector w/hood 100-02099-00 NA
6 80 Elco Crimp Pins 100-02100-00 NA

Euphonix ML530 Mic-Line Interface Operation Manual
18
Figure 5 ML530 Standard Configuration
12 male XLR to one
male Elco 38
Mic/Line Analog Out
MADI out to
Studio Hub
1
AES/EBU Sync In
from Sync DA
2
Control from PC253i
Interface Pilot
AM713
MADI
OUT
4 4
35, 6
Elco crimp pins and hoods for user
inputs are supplied in accessory
cable kits. Input cabling supplied by
customer

Euphonix ML530 Mic-Line Interface Operation Manual
19
Optional Input Patch
Figure 6 Input Patch Cable Diagram
NOTE: Patchbay, cables, pins and connectors are ordered separately as required.
Table 5 Input Patch Cable Specifications
*Elco hoods and crimp pins are included in standard 10M and 20M accessory cable kits.
**10M cable available, one male Elco 38 <> one male Elco 38, part# 030-06913-01
Part Qty Description Part # Length
A 1 Tie Line Patch 950-03770-01 NA
B* 2 Elco 38-Pin Connector w/hood 100-02099-00 NA
C* 80 Elco Crimp Pins 100-02100-00 NA
D** 2 ML530 Analog Out
one male Elco 38 <> one male Elco 38 030-07158-01 2 m
5 5
4
21
B
recommended locations
3
AM713
ADigital Core
B
Mic-Line Input Patch
4
ML530
Note: The optional input patchbay has the
capacity to provide input patching to 48
channels or two ML530 Interfaces. An
additional set of cable D is required for the
second ML530 interface.
Input cabling supplied
by customer
DD
A
B, C

Euphonix ML530 Mic-Line Interface Operation Manual
20
Figure 7 Input Patch Configuration
A - Optional Patchbay
12 male XLR to
one male Elco 38
Mic/Line Analog Out
MADI out to
Studio Hub
1
AES/EBU Sync In
from Sync DA
2
Control from PC253i
Interface Pilot
one male Elco 38 to
one male Elco 38
Patch to Mic/Line
AM713
MADI
OUT
4 4
3
D D
2
1
B,C
Optional Input Patch
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
Upper 37-48 Upper 25-36 Lower 37-48 Lower 25-36 Upper 13-24 Upper 1-12 Lower 13-24 Lower 1-12
Mic/Line Inputs
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
USERUSERUSERUSERUSERUSERUSERUSER
Other manuals for ML530
2
Table of contents
Other Euphonix Amplifier manuals