18
8.2 SEQUENTIAL MODE
8.2.1 SEQUENTIAL mode WITHOUT Obstacle Detection for double-leaf gates
ATTENTION!
Before proceeding to programming, start a functional cycle test to proof the motors’ thrust.
he thrust has to be proper to the gate weight no matters if light or heavy gates.
If adjustments are needed, regulate POWER so that the gate doesn’t stop opposing a light contrast pressure.
• Start programming with cool operators.
• The AUTOMATIC MODE PROGRAMMING can only perform if mechanical ground endstops are fitted,
in Opening and Closing.
-SENS in maximum position (to +)
- Programming can be carried out both with the remote control or WORK button.
- Press TEST for 3 sec., DL1 starts blinking, release.
- Press the button of the remote control previously loaded. M1 motor STARTS OPENING.
- At 80% of opening press the remote control to start SLOW DOWN.
- When fully open let the motor run for 3/4 sec., then press the remote control again.
- Now M1 settings are LOADED.
- Press the remote control, the control panel starts counting the DELAY TIME in opening (max. 20 sec.)
- Press the remote control again to set the desired delay time (standard operation 2/3 sec.)
- Now the DELAY TIME in opening is loaded. M2 motor STARTS OPENING.
- At 80% of opening press the remote control to start SLOW DOWN.
- When fully open let the motor run for 3/4 sec., then press the remote control.
- Now M2 settings are LOADED.
- Press the remote control, M2 motor STARTS CLOSING.
- Press the remote control, the control panel starts counting the DELAY TIME in closing (max. 20 sec.)
- Press the remote control again to set the desired delay time (standard operation 2/3 sec.)
-Now M1 motor starts automatically closing.
- Let gates complete the closing run.
- When the procedure is finished, all time settings are saved.
The control panel is now ready for normal operation
Check the good operation of the gate. If time settings need to be adjusted go back to programming
and repeat the whole programming procedure.
8.2.2 SEQUENTIAL mode WITHOUT Obstacle Detection for single-leaf gates
-SENS in maximum position (to +)
- Programming can be carried out both with the remote control or WORK button.
- Press TEST for 3 sec., DL1 starts blinking, release.
- Press the button of the remote control previously loaded. M1 motor STARTS OPENING.
- At 80% of opening press the remote control to start SLOW DOWN.
- When fully open let the motor run for 3/4 sec., then press the remote control again.
- Now M1 settings are LOADED and the motor starts CLOSING.
- Let gate completes the closing run.
- When the procedure is finished, all time settings are saved.
The control panel is now ready for normal operation
Check the good operation of the gate.
If time settings need to be adjusted go back to programming and repeat the whole programming procedure.