euromet AYSU SNZ UW Series User manual

*Nature friendly, long lifetime
*Ultrasonic Measurement
*Designed for household usage
*High measuring accuracy
*Suitable for drinking water installations
*AMR options
*Data storage of 18 months history
*MID approved and certificated
*First Class materials and production technology Protective
for external and cl˜mate conditions with durable body
*Prepaid option, central system control via GSM or GPRS
option, RF, M-Bus, ModBus, LoRa(Long Range), RS 485
options
*Wide and dynamic measurement range
*Accurate waterflow measurement with very low-pressure
losses
ULTRASONIC WATER METER
Q4
Q3
Q2
Q1
Q / Q
Q / Q
Q / Q
(MPE )
(MPE )
T
Bar
400
1,6
1,25
2
±5 %
T 30 & T 50
MAP 16
Su sıcaklığı ≤ 30°C ise ± %2
Su sıcaklığı > 30°C ise ± %3
BASICAL TECHNICAL DATA
DN Dn15 Dn20 Dn25 Dn32 Dn40
mm
≤ 5
≤ 4
≥ 0,0128
≥ 0,008
≤7,875
≤6,3
≥0,02016
≥0,0126
≤12,5
≤10
≥0,032
≥0,02
≤20
≤16
≥0,0512
≥0,032
≤
≤
3,125
2,5
≥0,008
≥0,005
AYSU SNZ-XX-UW
DN 15 to DN 40
EUROMET
Overload owrate
Permanent owrate
Transitional owrate
Minimum owrate
The measuring range
The transitional owrate
The overload owrate
Water pressure class
Temperature Class
Accuracy Class
Maximum permissible error for the
upper owrate zone
Maximum permissible error for the
lower owrate zone
Nominal Diameter
Pressure loss class ΔP63

USER MANUAL
ULTRASONIC WATER METER –AYSU SNZ-XX-UW
EUROMET ÖLÇÜ ALETLERİ LTD. ŞTİ.
Office Address: OSTİM ATB İŞ MERKEZİ C BLOK NO :84 06105 YENİMAHALLE - ANKARA
e-mail: [email protected] - website: www.euromet.com.tr
Tel: +90 312 397 1214 - Fax: +90 312 397 1215

1
1Brief Introduction
⚫The ultrasonic water meter is a new type of intelligent all-electronic meter. It
integrates measurement and display to achieve accurate measurement with a
minimum flow of 0.01 m3/h.
⚫Achieve multi-angle installation and minimize the pipe pressure loss.
⚫Dedicated to household measurement in residential quarters
⚫Connect to the GSM wireless concentrator produced by our company, using GSM mobile
public network for data transmission to form a wireless monitoring system. It automatically
reports abnormal status.
2Technical Details
2.1 Basic technical details
Parameter
Performance
Diameter (mm)
DN15~40
Q3/Q1
R250/R400
Pressure Loss
DN15 & DN20: Δp40
DN25 & DN32 & DN40: Δp63
Measured Medium
water or homogeneous liquid
*Pipesmust be full with measured medium.
Accuracy
Class 2 (Class B)
Maximum Working Pressure
1.6MPa
Work Environment
5℃~+55℃, ≤100%RH
Temperature Grade
T30/T50
Sensitivity of Upstream Flow Field
U10
Sensitivity of Downstream Flow Field
D5
Climatic and Mechanical
Environmental Grades
B
EMC Grade
E1
Keypad
Magnetic Key
LCD
LCD 8 digits + prompt

2
Menu Contents
instantaneous flow (m³/h)
cumulative flow (m³)
screen detection
meter address
cumulative working time (h)
date (yy-mm-dd)
software version
diameter
Display Range
cumulative flow: 0m³~+9999.9999m³
Communication
Photoelectric Interface
baud rate: 2400bps
based on CJ/T 188 self-defined protocol
Wireless
Communication
communication method: LoRa
frequency: 470MHZ-510MHZ
transmission distance: ≧3000m (open place)
based on CJ/T 188 self-defined protocol
Power Supply
battery power supply DC3.6V
(work continuously for more than 6 years)
Power Consumption
<0.2mW
Waterproof Rate
IP68
Storage Temperature
-25℃~+55℃
Cable Length
1.0m
Installation Position
inflow pipe
Table 2-1 Technical Details – 213G
2.2 Flow Parameters
Diameter
Permanent
Q3
(m³/h)
Transitional
Q2
(m³/h)
Minimum
Q1
(m³/h)
Overload
Q4
(m³/h)
DN15 (R250)
2.5
0.016
0.010
3.125
DN15 (R400)
2.5
0.010
0.00625
3.125
DN20 (R250)
4.0
0.025
0.016
5.0
DN20 (R400)
4.0
0.016
0.010
5.0
DN25 (R250)
6.3
0.04
0.0252
7.875
DN25 (R400)
6.3
0.025
0.016
7.875
DN32 (R250)
10
0.064
0.04
12.5

3
DN40 (R250)
16
0.102
0.064
20
Table 2-2 Flow Parameters
2.3 LoRa Parameters
Performance
Parameters
Quiescent Dissipation
< 25uA
Transmitted Power
< 50mW
Working Frequency
470MHZ-510MHZ
Maximum Transmission Distance in Open Place
≧3 KM
Emission Current
< 100mA
Receive Electric
< 14mA
Wireless Working Mode
Regular Wake Up (WOR)
Table 2-3 LoRa Parameters
3LoRa Wireless Working System + GPRS
Topological Graph
Figure 3-1 LoRa Wireless Working System + GPRS Topological Graph

6
6Installation and Connection
6.1 Installation and Connection Requirements
Install the meter in strict accordance with the requirements. Strictly forbidden to self-remove
meter.
Before installing the water meter, remove dirt and other rubbish in pipeline to avoid
malfunction of water meter.
Leave enough space for meter and connectors installation.
To ensure the measurement accuracy, the reserved length space is the following. In the front of
meter, the length space is over 10 times of diameter. Behind meter, the length space is over 5
times of diameter. Avoid the interference from elbow pipe, tee, cone pipe and pump. If there is
a reduced diameter pipe installed before meter, the reserved length space will be over 15 times
of diameter; if a 90° elbow, the length must be 20 times of diameter; if a half-opening valve,
the space is over 50 times of diameter.
*D=diameter
LF= the length in the front of meter
LB=the length behind meter
Special Case
Reserved Pipe Length
usual (normal installation)
LF > 10D
LB > 5D
a reduced diameter pipe in the front of meter
LF > 15D
a 90° elbow in the front of meter
LF > 20D
a half-opening valve in the front of meter
LF > 50D
Table 6-1 Special Cases and Reserved Pipe Length
Avoid damage to the water meter caused by impact or vibration of the meter installation
environment, and avoid damage caused by excessive stress from pipes and fittings. If necessary,
please install the water meter on the base or bracket.
Prevent extreme water temperature, extreme temperature, and external environment corrosion
to water meter damage.
Avoid cavitation, surge and water hammer.
6.2 Meter Installation
➢The installed pipe must be filled with water. Install the meter on a vertical pipe in which the
liquid flows upwards or diagonally upwards. If not, select a horizontal pipe. Try to AVOID
installing the meter in a vertical pipe with the liquid flowing downwards or diagonally
downwards.
➢AVOID installing meter at the highest point of pipeline to prevent the air bubbles accumulated

7
and interfere with measurement.
Figure 6-1 Installation Method (1)
➢Reserve a space at the water pipe for meter installation.
Figure 6-2 Meter Installation (2)
➢Concentrically align meter with pipe. Use a wrench to connect the pipe blade to meter thread
and tighten it.
Figure 6-3 Meter Installation (3)

8
7Trouble Removal
No.
Malfunction
Description
Solution
Notes
1
Low Voltage
LCD displays
Please change
a new battery.
2
Reverse Flow
LCD displays a
negative number
Install meter
in right
direction.
Please send meter
back to factory if
this problem can’t
be solved in this
way.
3
Install Meter Downstream
(1) abnormal data
(2) data jump
disorderly
Install meter
according to
instructions.
Insufficient Reserved
Place in the Front
of/Behind the Meter
Great Bend in the Front
of/Behind the Meter
The Pipe Diameter
Changes Greatly in the
Front of/Behind the Meter
4
LCD displays
flow but without
temperature
Do not dismantle
without permission.
Please return meter
to factory for
settlement.
Table 7-1 Trouble Removal
8Parts List
No.
Item
Unit
Quantity
Notes
1
Water Meter
piece
1
2
Product Manual
piece
1
optional
3
CERTIFICATION & Warranty Card
piece
1
optional
4
Sealing Ring
piece
2
optional
5
Connector Screw
piece
2
optional
6
Connector Nut
piece
2
optional
Table 8-1 Parts List



This manual suits for next models
5