TABLE OF CONTENTS
1INTRODUCTION.................................................................................................... 1
2DISPLAY & KEYPAD FUNCTIONS...................................................................... 2
2.1 DISPLAY................................................................................................................................... 2
2.2 KEYPAD ................................................................................................................................... 3
3PREPARATION ..................................................................................................... 4
3.1 INSERTING THE BATTERIES ........................................................................................................ 4
3.2 CONNECTING THE DO PROBE.................................................................................................... 4
3.3 CONNECTING THE AC/DC ADAPTER........................................................................................... 6
3.4 CONNECTING THE RS232C CABLE ............................................................................................ 6
3.4.1 RS232C Configuration..................................................................................................... 7
4CALIBRATION....................................................................................................... 8
4.1 IMPORTANT INFORMATION ON METER CALIBRATION ..................................................................... 8
4.2 TEMPERATURE CALIBRATION ..................................................................................................... 9
4.3 DO CALIBRATION (WITH ATC) –% SATURATION MODE .............................................................. 10
4.3.1 To calibrate 100% Saturation: ....................................................................................... 10
4.3.2 To calibrate 0% Saturation: ........................................................................................... 10
4.4 DO CALIBRATION IN MG/L (PPM)MODE..................................................................................... 11
5MEASUREMENT ................................................................................................. 12
5.1 AUTOMATIC TEMPERATURE COMPENSATION ............................................................................. 12
5.2 MANUAL TEMPERATURE COMPENSATION (MTC) ....................................................................... 12
5.3 TAKING MEASUREMENTS ......................................................................................................... 13
5.3.1 Taking measurements with READY indicator selected on............................................. 13
5.3.2 Taking measurements with the AUTO HOLD feature selected on................................. 13
6MEMORY FUNCTION.......................................................................................... 14
6.1 MEMORY INPUT ...................................................................................................................... 14
6.2 MEMORY RECALL ................................................................................................................... 14
7PRINT FUNCTION ............................................................................................... 15
7.1 USING DO 110 METER WITH PRINTER OR COMPUTER............................................................... 15
7.2 SENDING DATA TO COMPUTER OR PRINTER ............................................................................. 16
7.2.1 Print Current Data Manually .......................................................................................... 17
7.2.2 Print Data on Timed Interval.......................................................................................... 17
7.3 PRINT DATA FROM STORED MEMORY ....................................................................................... 18
8ADVANCED SETUP FUNCTIONS...................................................................... 20
8.1 ADVANCED SETUP MODE OVERVIEW ...................................................................................... 21
8.2 P1.0 :UNIT CONFIGURATION (COF) ........................................................................................ 23
8.2.1 P1.1: READY Indicator and Auto Hold function............................................................. 23
8.2.2 P1.2: Select °C or °F temperature units......................................................................... 24
8.2.3 P1.3: Selection of Automatic or Manual Temperature Compensation............................ 24
8.2.4 P1.4: Select mg/L or ppm mode.................................................................................... 25
8.3 P2.0: VIEWING PREVIOUS CALIBRATION DATA (CAL) ................................................................ 26
8.4 P3.0: VIEW ELECTRODE DATA (ELE) ....................................................................................... 26
8.4.1 EL.1 Viewing the electrode Slope Factor....................................................................... 26
8.4.2 EL.2 Viewing the % Saturation Offset (Only available in % Saturation Set Up menu): .. 27
8.4.3 Viewing the 100% Saturation mV value......................................................................... 27
8.4.4 Viewing the 0% Saturation mV value............................................................................. 27
8.5 P4.0 :AUTO-OFF (ATO).......................................................................................................... 28
8.6 P5.0 :RESET TO FACTORY DEFAULT (RST) .............................................................................. 29
8.6.1 Calibration Reset........................................................................................................... 29