Everbrite Electronics EVERTRON 2612 Series User manual

File:\\ 006_0064.doc Support: http://www.evertron.net (800) 431-7383 Internet Sales: http://www.neoncentral.com 11/21/03 Rev I
Solid State, High Voltage Power Supply For Cold-Cathode (Gas Discharge) Lighting Applications
FEATURES:
UL and cUL Recognized
Secondary Ground Fault Interruption (SGFI)
Over Voltage Interruption
Anti-Bubbling / Anti-Mercury Migration
Circuitry
Open / Short Circuit Protected
Available Only In 120V Non-dimming Models
Dual AC Auxiliary Voltage Outputs
Compatible with Evertron Animotion
10 Foot Line Cord Standard on 800-0128,
IEC-320 power inlet provided on 800-0139
Light Weight / Cost Competitive
SPECIFICATIONS: INPUT
Voltage: 120 VAC Nominal
(108-132 VAC operating range)
Frequency: 50/60 Hz.
Current: 3.0 Amps rms maximum
Power: 240 Watts
(Recommended operating max.
at nominal line voltage)
WEIGHT
1.5 Lbs. (0,68 kg.)
OUTPUT
Rated Output: 5.5kV rms
Short Circuit Current: 27mA rms
Equivalent Sign Volts: 10kV maximum
2kV minimum
Class 2 Outputs: 2 x 20-22VAC 2.4A rms each,
Frequency (all AC out): 20 kHz
TEMPERATURE
Ambient operating: 104F (40C) Maximum (in open air)
FAULT MODE:
The unit will automatically turn off whenever a SGFI, or Over Voltage fault occurs.
If the output has an imbalance of 12mA or more, or exceeds 15kVpk for longer than 250ms, the unit will shut
down and will remain shut down until power is cycled by the pull cord.
To restore normal operation, switch the unit OFF for 5 seconds, then switch ON again.
Alternately, operation can be restored by unplugging the power cord, waiting 30 seconds, then reconnecting the
power cord.
If normal operation cannot be restored, refer sign to a qualified repair facility.
TABLE 1
LUMINOUS TUBE LENGTH (FEET)
Tube Size Diameter [mm]
15
13
12
11
10
9
8
Fill Pressure mm of Hg at 100°C
9
10
11
12
13
15
16
Tube Length - Neon
48
37
31
26
21
16
12
Tube Length - Mercury/Argon
58
46
40
35
30
25
20
TUBE LENGTH ADJUSTMENTS:
Deduct 1.0 foot for each electrode pair beyond the first pair.
Deduct 5.0 feet for use with sheet metal or metalized sign frame.
Deduct 5.0 feet for each 20°F above ambient temperature of 75°F.
2612 Series
UL2161 Compliant Neon Power Supply
120V Model 800-0128, 800-0139 (IEC)

File:\\ 006_0064.doc Support: http://www.evertron.net (800) 431-7383 Internet Sales: http://www.neoncentral.com 11/21/03 Rev I
2612 Series 120V Models 800-0128
INSTALLATION:
Mounting (see Figure 1):
For Indoor Use Only
Use (2), #10-24 machine screws, 5/16” longer than the thickness of the mounting surface.
If mounting to a metal surface other than a bar frame, a minimum 0.75 in. thick non-metallic spacer must be used.
Mount power supply with the bottom surface in a vertical plane, such that the vents are facing up and down.
For proper grounding of the sign frame, use a #10 internal tooth star washer between the sign frame and the
mounting boss identified with the Earth Ground symbol.
- CAUTION -
This device should not be mounted in spaces or near bodies that may exceed an ambient
temperature of 40oC (104oF).
Wiring:
The molded plug on the power cord must be connected to a dedicated 120V, 20A branch circuit receptacle with
earth grounding means.
The tube load for the main power supply unit shall not exceed the footage limits specified in Table 1.
The power supply output leads (GTO 10) are to be connected to tube load as shown in Figure 2.
When connected directly (without Animotion), do not exceed two Auxiliary transformers per Class 2 output
channel. For proper connection and loading of Auxiliary transformers when using an Animotion Controller,
please refer to the Everbrite Animotion System Installation Guide.
- CAUTION -
When two or more power supplies are required on a single neon sign, the output leads from one
MUST NOT be wired in series or in parallel with the output leads from the other(s).
Auxiliary Outputs: 800-0128, 800-0139 = 20-22VAC
WARRANTY:
Everbrite Electronics, Inc. warrants to the original purchaser that the product described herein is free from defects in
material and workmanship for a period of four years from date of manufacture and will replace or repair, at the discretion
of the manufacturer, products found to be defective. The liability of the company is limited to the replacement of the
defective product.
No other warranty, whether expressed or implied, including any warranty of merchantability of fitness for a particular purpose, shall exist in
connection with the sale or use of such products.
EVERTRON
P/N 800-0128
800-0139
ANIMOTION
CONTROLLER
P/N 800-0078, 0066, 0067,
0068, 0069, 0145
CHANNEL “A”
CHANNEL “B”
HV - CONTINUOUSLY ILLUMINATED TUBE
LOAD
FIGURE 2
T4
55
3
T2
T3
T1
CLASS 2-OUTPUT 2
CLASS 2-OUTPUT 1
AUXILIARY TRANSFORMERS
AND ANIMATED GLASS
800-0174, 800-0175, 800-0176
---------------------------------------
DIRECT CONNECT VERSION
800-0177 SEE DATASHEET
8.00 [203,2 MM]
#10
-
24 UNC
-
2B THREAD
0.38 [9,7] DEEP MAX.
2 PLACES
GROUNDING
LUG
FIGURE 1
VENTS
0.75 [19,0MM]
NON METALLIC SPACER
- EXCEPT BAR FRAME
CLASS 2
AUXILIARY
OUTPUT
GTO 10 OUTPUT
LEADS 21” LONG
3.1"
1.9"
9.3"
800-0128
IEC Version AC Pwr
800-0139
This manual suits for next models
2
Table of contents
Popular Power Supply manuals by other brands

Interlogix
Interlogix Advisor Installation sheet

Lutron Electronics
Lutron Electronics Sivoia QED SVQ-10-PNL-230 installation instructions

Omron
Omron S82J Series manual

Ultra Products
Ultra Products LSP Pro Lifetime Series Specification sheet

XPG
XPG PYLON BRONZE Series quick start guide

Emerson
Emerson netsure 9500 Operation manual