0POWERswitch
Whenturnedon,theindicatorsPOWERandeitherofCCand
CV
light.Thepowerswitchisautomaticallycutoffwhenpro-
tection(overvoltage/overcurrent/temperature)hasoperated.
(2)Voltmeter
Indicates
theoutputvoltageorthepresetvoltage.
(3)Ammeter
Indicates
theoutputcurrentorthepresetcurrent.
(4)
VOLTAGE
Control
that
presetsvoltageforconstant-voltageoperation.
Turnitclockwisetoraisetheoutputvoltage.
(5)
CURRENT
Control
that
presetscurrentforconstant-currentoperation.
Turnitclockwiseto
increases
theoutputcurrent.
(6)CVindicator
Indicates
duringconstant-voltageoperation.
(7)CCindicator
Indicates
duringconstant-currentoperation.
(8)OUTPUTindicator
Red
LEDindicateswhentheoutputison.Thepresetvoltageis
availableattheoutputterminalswhenthisindicatorison.
(9)OUTPUTswtich
Outputswitch(contactless)
that
turnsonandofftheoutput
electrically.
Whentheoutputison
(-•-),
theOUTPUTindicator
8lightsandthevoltagethevoltmeterisreadingisoutputat
theoutputterminalsandtheammeterreadsthecurrent.
#V/l
CHECK
Voltage/currentcheckswitch.Aslongasthisswitchis
depressed,
thevoltmeterreadsthepresetvoltageandtheam-
meterthepresetcurrentso
that
youmaypresetvoltageand
current.Tocheckthepresetvoltageandcurrent,depressthis
switch
whentheOUTPUTswitchison.
(fj)OVP
CHECK
Overvoltageprotectionlevelcheckswitch.Depressthis
switch
andthevoltmeterreadsthepresetovervoltagepro-
tecitonlevelso
that
youmaypresetthelevel
with
theOVP
adjuster
12.
@
OVPadj.control
Semi-fixedadjustmentcontrolpermittingtopresettheover-
voltageprotectionlevel.
nOutputterminal(+)
Positive
outputterminal(red).
(Q)Outputterminal(-)
Negativeoutputterminal(white).
©GND
Ground
terminalconnectedtotheframe.Thisisconnected
also
totheoutputterminal(-)normally.
Voltmeterzeroadjuster
Adjuster
ofthevoltmeterzeropoint.(NotforD type)
(\T) Ammeterzeroadjsuter
Adjuster
oftheammeterzeropoint.(NotforD type)
9