5.8.5.3 Automatic cut-out ..........................................................................................39
5.8.6 Function sequences/operating modes..........................................................................40
5.8.6.1 Explanation of symbols .................................................................................40
5.8.6.2 Non-latched mode.........................................................................................41
5.8.6.3 Latched mode................................................................................................42
5.8.6.4 spotArc ..........................................................................................................43
5.8.6.5 Spotmatic ......................................................................................................45
5.8.6.6 Non-latched operation, version C..................................................................47
5.8.7 Pulses, function sequences..........................................................................................48
5.8.7.1 TIG pulses –non-latched operation..............................................................48
5.8.7.2 TIG pulses - latched operation......................................................................48
5.8.8 Pulse variants...............................................................................................................49
5.8.9 TIG activArc welding.....................................................................................................51
5.8.10 Welding torch (operating variants)................................................................................52
5.8.10.1 Tap torch trigger (tapping function)...............................................................52
5.8.11 Torch mode and up/down speed setting ......................................................................53
5.8.11.1 Standard TIG torch (5-pole) ..........................................................................54
5.8.11.2 TIG up/down torch (8-pole) ...........................................................................56
5.8.11.3 Potentiometer torch (8-pole) .........................................................................58
5.8.11.4 Configuring the TIG potentiometer torch connection....................................59
5.8.11.5 RETOX TIG torch (12-pole)...........................................................................60
5.8.11.6 Setting the first increment..............................................................................61
5.9 MMA welding................................................................................................................................62
5.9.1 Connecting the electrode holder and workpiece lead ..................................................62
5.9.2 Select welding task.......................................................................................................63
5.9.3 Arcforce.........................................................................................................................63
5.9.4 Antistick.........................................................................................................................63
5.9.5 Hotstart.........................................................................................................................64
5.9.5.1 Hotstart current..............................................................................................64
5.9.5.2 Hotstart time..................................................................................................64
5.10 Remote control.............................................................................................................................65
5.10.1 Manual remote control RT1 19POL..............................................................................65
5.10.2 RTG1 19POL manual remote control...........................................................................65
5.10.3 Manual remote control RTP1 19POL ...........................................................................65
5.10.4 Manual remote control RTP2 19POL ...........................................................................65
5.10.5 RTP3 spotArc 19POL manual remote control..............................................................65
5.10.6 Foot-operated remote control RTF1 19POL 5 M / RTF2 19POL 5 M..........................66
5.10.6.1 Ramp function foot-operated remote control RTF 1 / RTF 2........................67
5.11 Interfaces for automation .............................................................................................................68
5.11.1 TIG interface for mechanised welding..........................................................................68
5.11.2 Remote control connection socket, 19-pole .................................................................69
5.12 PC interface .................................................................................................................................70
5.13 Machine configuration menu........................................................................................................70
5.13.1 Selecting, changing and saving parameters.................................................................70
6Maintenance, care and disposal.........................................................................................................74
6.1 General.........................................................................................................................................74
6.2 Maintenance work, intervals ........................................................................................................74
6.2.1 Daily maintenance tasks...............................................................................................74
6.2.1.1 Visual inspection ...........................................................................................74
6.2.1.2 Functional test...............................................................................................74
6.2.2 Monthly maintenance tasks..........................................................................................74
6.2.2.1 Visual inspection ...........................................................................................74
6.2.2.2 Functional test...............................................................................................74
6.2.3 Annual test (inspection and testing during operation)..................................................75
6.3 Disposing of equipment................................................................................................................75
6.3.1 Manufacturer's declaration to the end user..................................................................75
6.4 Meeting the requirements of RoHS..............................................................................................75
7Rectifying faults....................................................................................................................................76
7.1 Checklist for rectifying faults........................................................................................................76
7.2 Error messages (power source)...................................................................................................78