- A manually forcced water softener regeneration (ECKEY) can only be done on the lead
water softener control valve and only if the water softener system is not in regeneration.
Water Softener System 7 Alternating (2 valve water softener):
During normal water softener operation the time of day display alternates with the water
softener volume remaining display (gallons or m3). The water softener volume remaining is
for the individual water softener.
- As treated water is used, the water softener remaining volume counts down from the
water softener calculated capacity to zero or (---). When this occurs, a water softener
regeneration cycle queues.
- The water softener control valve requiring regeneration sends a lock command to the
standby water softener control valve. The standby water softener control valve goes in to
service and exhausted water softener starts a regeneration cycle.
- If a water softener control valve is in regeneration and the other water softener exhausts its
volume remaining, then the exhausted water softener remains in service with regeneration
queued until the other water softener goes into standby. The exhausted water softener
goes into standby after completing regeneration water flow through the water softener
control valve is indicated by the flow dot that flashes in a direct relationship to flow rate.
Water Softener System 9 Alternating(2-4 water softeners):
During normal water softener operation the time of day display alternates with the water
softener volume remaining display (gallons or m3). The water softener volume remaining is
for the individual water softener.
- As treated water is used, the water softener remaining volume counts down from the
water softener calculated capacity to zero or (---). When this occurs, a water softener
regeneration cycle queues.
- The water softener control valve requiring regeneration sends a lock command to the
standby water softener control valve. The standby water softener control valve goes in to
service and exhausted water softener starts a regeneration cycle.
- If a water softener control valve is in regeneration and the other water softener exhausts its
volume remaining, then the exhausted water softener remains in service with regeneration
queued until the other water softener goes into standby. The exhausted water softener
goes into standby after completing regeneration.
- All water softeners remain in service except those in standby or regeneration.
- Water flow through the water softener control valve is indicated by the water softener flow
dot that flashes in a direct relationship to flow rate.
Important Water Softener System Operation Tips:
- When programming muti water softener systems, program lag water softener first and
then lead water softener. This eliminates or minimizes program and communication errors.
- When changing a water softener valve from one water softener system type to another
water softener system type, perform a master reset first.