Exor UniOP eTOP 500 Series User manual

eTOP Series 500
Operating Instructions
User’s Manual for eTOP Series 500 Touchscreen Products
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A.

2
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
Copyright © 2018 Exor International S.p.A. – Verona, Italy
Subject to change without notice
The information contained in this document is provided for informational purposes only. While efforts were made to verify the accuracy of the information
contained in this documentation, it is provided “as is” without warranty of any kind.
Third-party brands and names are the property of their respective owners.
www.exorint.com

3
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
Table of Contents
Introduction 4
Safety guide 5
1 Product overview 6
2 Standards and approvals 7
3 Technical specications 8
4 Technical data 10
4.1 Dimensions 14
4.2 Installation environment 16
4.3 Installation procedure 17
5 Connections 18
5.1 Serial port 20
5.2 Ethernet port 21
5.3 Option plugin module 22
6 Power supply, grounding and shielding 24
7 Battery 25
8 Cleaning faceplates 26
9 Getting started 26
10 System settings 27
11 LED indicator on front panel 30
12 Unpacking and packing Instructions 31

4
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
Introduction
The operational guidelines described below is information which relates to the device, installation, tran-
sportation, storage, assembly, use and maintenance.
This Operating Instruction describes the main features of the operator panels. The Guide refers to the
following models:
eTOP504 Operator interface with TFT color 4,3” display touchscreen
eTOP506 Operator interface with TFT color 5.7” display touchscreen
eTOP507 Operator interface with TFT color 7” widescreen display touchscreen
eTOP507M Operator interface with TFT color 7” widescreen display touchscreen, 1GHz CPU
eTOP510 Operator interface with TFT color 10.4” display touchscreen
eTOP512 Operator interface with TFT color 12.1” display touchscreen
eTOP513 Operator interface with TFT color 13.3” widescreen display touchscreen
eTOP515 Operator interface with TFT color 15” display touchscreen

5
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
Safety Guide
The manual contains safety standards that must be respected for the personal safety and to avoid damage.
Indications of attention are divided into three levels of severity:
DANGER: indicates a failure to observe safety rules and such failure may cause death or serious injuries.
ATTENTION: indicates a failure to observe safety rules and that deciency may cause damage.
CAUTION: indicates a failure to observe safety rules and that deciency may cause defects to the equipment
or inconsistencies.
CAUTION
ATTENTION
DANGER
!
!

6
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
1 Production Overview
The Exor eTOP Series 500 HMI products combine state-of-the-art features and top performance with an
oustanding design. They are the ideal choice for all demanding HMI applications including factory and
building automation.
The eTOP Series 500 HMI panels have been designed to run the JMobile software.
• Designed for use with JMobile HMI software.
• Full vector graphic support. Native support of SVG graphic objects. Trasparency and alpha
blending.
• Full object dynamics: control visibility and transparency, move, resize, rotate any object on screen.
Change properties of basic and complex objects.
• TrueType fonts.
• Multilanguage applications. Easily create and manage your applications in multiple languages to
meet global requirements. Far East languages are supported. Tools available in JMobile Studio
support easy third-party translations and help reducing development and maintenance costs of the
application.
• Data display in numerical, text, bargraph, analog gauges and graphic image formats.
• Rich set of state-of-the-art HMI features: data acquisition, alarm handling, scheduler and timed
actions (daily and weekly schedulers, exception dates), recipes, users and passwords, RSS feeds,
rotating menus.
• Includes support for a wide range of communication drivers for Factory systems.
• Multiple drivers communication capability.
• Remote monitoring and control. Client-Server functionality.
• On-line and Off-line simulation with JMobile Studio.
• Powerful scripting language for automating HMI applications. Script debugging improves efciency
in application development.
• Rich gallery of vector symbols and objects.
• Optional plug-in modules for eldbus systems, I/O and controllers.

7
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
2 Standards and Approvals
The products have been designed for use in an industrial environment in compliance with the 2014/30/
EU EMC Directive.
The products have been designed in compliance with:
EN 61000-6-4 EN 55011 Class A
EN 61000-6-2 EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
The installation of these devices into the residential, commercial and light-industrial environments is al-
lowed only in the case that special in measures are taken in order to ensure conformity to EN 61000-6-3.
The products are in compliance with the Restrictions on Certain Hazardous Substances (RoHS) Directive
2011/65/EU
In compliance with the above regulations the products are CE marked.
Product Identication
The product may be identied through a plate attached to the rear cover. You will have to know the type
of unit you are using for correct usage of the information contained in the guide.
An example of this plate is shown in the gure below:
eTOP504 product model name
ETOP504U1P1 product part number
1846 year/week of production
AA00001HP123456789AA serial number
040100A15011000 version id of the product

8
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
3 Technical Specications
Touch screen technology Resistive
Back-up battery 3V 50mAh Lithium, rechargeable, not user-replaceable,
model VL2330.
Fuse Automatic
Serial Port RS-232, RS-485, RS-422 software congurable
User memory Flash 128MB for eTOP504, 506, 507
Flash 256MB for eTOP507M, eTOP510, 512, 513, 515
Recipe memory Flash
Hardware clock Clock/Calendar with back-up battery
Accuracy RTC (at 25°C operating) <100ppm
Environmental conditions
Operating temperature (vertical 0 ÷ +50°C EN 60068-2-14
installation)
Storage temperature -20 ÷ +70°C EN 60068-2-14
Operating and storage humidity 5 ÷ 85 % RH not-condensing EN 60068-2-30
Vibrations 5 ÷ 9 Hz, 7 mm p-p EN 60068-2-6
9 ÷ 150 Hz, 1 g
Shock ± 50 g, 11 ms, 3 pulses per axis EN 60068-2-27
Protection class IP66 front panel * EN 60529
* The front face of the unit, installed in a solid panel, has been tested using conditions equivalent to the standards
shown in the “Environmental conditions”. Even though the level of resistance unit is equivalent to these standards, oils
that should have no effect on the panel can possibly harm the unit. This can occur in areas where either vaporized oils
are present, or where low viscosity cutting oil are allowed to adhere to the unit for long periods of time. If the front face
protection sheet on the panel becomes peeled off, these conditions can lead to the ingress of oil into the panel and
separate protection measures are suggested.
If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the
original level of the protection cannot be guaranteed.
Electromagnetic Compatibility (EMC)
Radiated disturbance test Class A EN 55011
Electrostatic discharge immunity test 8 kV (air electrostatic discharge) EN 61000-4-2
4 kV (contact electrostatic discharge)
Radiated, radio-frequency, 80 MHz ÷ 1 GHz, 10V/m EN 61000-4-3
electromagnetic eld immunity test 1,4 GHz ÷ 2 GHz, 3 V/m
2 GHz ÷ 2.7 GHz, 1 V/m

9
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
Burst immunity test ± 2 KV DC power port EN 61000-4-4
± 1 KV signal line
Surge immunity test ± 0,5 KV DC power port (line to earth) EN 61000-4-5
± 0,5 KV DC power port (line to line)
± 1 KV signal line (line to earth)
Immunity to conducted disturbances
inducted by radiofrequency eld 0.15 ÷ 80 MHz, 10V EN 61000-4-6
Voltage dips, short interruptions and
voltage variations immunity test Port: AC mains; Level:
100% duration: 1 cycle and 250 cycles (50Hz);
40% duration: 10 cycles (50Hz);
70% duration: 25 cycles (50Hz);
Phase: 0°-180°
Test executed on the 230Vac side of the Exor International Power Supply EN 61000-4-11
Durability information
Backlight service life 40000 Hrs. or more
(LED type) (Time of continuos operation until the brightness of the
backlight reaches 50% of the rated value when the
sorrounding air temperature is 25°C) - see Note 1
Front foil 10 years if the surrounding air temperature is 25°C
(without directly exposure to
sunlight or UV ray)
UV Resistance Indoor applications: After 300 hours cycled humidity in
QUV accelerated weathering, some yellowing and
brittleness may be present. - see Note 2.
Touch screen reliability > 1 milion operations
Note 1: Extended use in environments where the surrounding air temperature is 40°C or higher may degrade
backlight quality/reliability/durability.
Note 2: Solvent resistance:
Contact for 1/2 hour at 21°C, No visible effect: Acetone, Butyl Cellosolve, Cyclohexanone, Ethyl Acetate,
Hexane, Isopropyl Alcohol, MEK, Methylene Chloride, Toluene, Xylene
Contact for 24 hours at 49°C, No visible effect: Coffee, Ketchup, Lemon Juice, Mustard (slight yellow stain),
Tea, Tomato juice.
3 Technical Specications

10
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
4 Technical Data
Model eTOP504 eTOP506
Display / Backlight TFT Color / LED TFT Color / LED
Colors 64K 64K
Resolution 480x272 320x240
Diagonal (inches) 4.3” 5.7”
Dimming yes yes
User memory Flash 128 MB 128 MB
SD card slot yes yes
Recipe memory Yes. Flash memory storage limited only by
available memory
Yes. Flash memory storage limited only by
available memory
Serial Port RS-232, RS-485, RS-422
DB9 female software congurable
RS-232, RS-485, RS-422
DB9 female software congurable
Ethernet port 2 10/100 Mbit with integrated switch 2 10/100 Mbit with integrated switch
USB port 1 Host interface version 2.0 and version
1.1
2 Host interface, 1 version 2.0,
1 version 2.0 and 1.1
Expansion slot 1 Optional Plugin 2 Optional Plugin
Battery rechargeable rechargeable
Real Time Clock yes yes
Voltage 18-32VDC (*) 18-32VDC (*)
Current rating (at 24VDC) 0.4A 0.65A
Weight 1 Kg 1 Kg
(*) For applications requiring compliance with EN 61131-2 and specically in reference to 10 ms voltage dips, the
minimum power supply voltage is 18Vdc,

11
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
4 Technical Data
Model eTOP507 eTOP507M
Display / Backlight TFT Color / LED TFT Color / LED
Colors 64K 64K
Resolution 800x480 800x480
Diagonal (inches) 7” widescreen 7” widescreen
Dimming yes yes
User memory Flash 128 MB 256 MB
SD card slot yes yes
Recipe memory Yes. Flash memory storage limited only by
available memory
Yes. Flash memory storage limited only by
available memory
Serial Port RS-232, RS-485, RS-422
DB9 female software congurable
RS-232, RS-485, RS-422
DB9 female software congurable
Ethernet port 2 10/100 Mbit with integrated switch 2 10/100 Mbit with integrated switch
USB port 2 Host interface, 1 version 2.0,
1 version 2.0 and 1.1
2 Host interface, 1 version 2.0,
1 version 2.0 and 1.1
Expansion slot 2 Optional Plugin 2 Optional Plugin
Battery rechargeable rechargeable
Real Time Clock yes yes
Voltage 18-32VDC (*) 18-32VDC (*)
Current rating (at 24VDC) 0.65A 0.7A
Weight 1 Kg 1 Kg
(*) For applications requiring compliance with EN 61131-2 and specically in reference to 10 ms voltage dips, the
minimum power supply voltage is 18Vdc,

12
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
4 Technical Data
Model eTOP510 eTOP512
Display / Backlight TFT Color / LED TFT Color / LED
Colors 64K 64K
Resolution 800x600 800x600
Diagonal (inches) 10.4” 12.1”
Dimming yes yes
User memory Flash 256 MB 256 MB
SD card slot yes yes
Recipe memory Yes. Flash memory storage limited only by
available memory
Yes. Flash memory storage limited only by
available memory
Serial Port RS-232, RS-485, RS-422
DB9 female software congurable
RS-232, RS-485, RS-422
DB9 female software congurable
Ethernet port 2 10/100 Mbit with integrated switch 2 10/100 Mbit with integrated switch
USB port 2 Host interface, 1 version 2.0,
1 version 2.0 and 1.1
2 Host interface, 1 version 2.0,
1 version 2.0 and 1.1
Expansion slot 2 Optional Plugin 2 Optional Plugin
Battery rechargeable rechargeable
Real Time Clock yes yes
Voltage 18-32VDC (*) 18-32VDC (*)
Current rating (at 24VDC) 1A 1.2A
Weight 2.1 Kg 2.8 Kg
(*) For applications requiring compliance with EN 61131-2 and specically in reference to 10 ms voltage dips, the
minimum power supply voltage is 18Vdc,

13
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
4 Technical Data
Model eTOP513 eTOP515
Display / Backlight TFT Color / LED TFT Color / LED
Colors 64K 64K
Resolution 1280x800 1024x768
Diagonal (inches) 13.3” widescreen 15”
Dimming yes yes
User memory Flash 256 MB 256 MB
SD card slot yes yes
Recipe memory Yes. Flash memory storage limited only by
available memory
Yes. Flash memory storage limited only by
available memory
Serial Port RS-232, RS-485, RS-422
DB9 female software congurable
RS-232, RS-485, RS-422
DB9 female software congurable
Ethernet port 2 10/100 Mbit with integrated switch 2 10/100 Mbit with integrated switch
USB port 2 Host interface, 1 version 2.0,
1 version 2.0 and 1.1
2 Host interface, 1 version 2.0,
1 version 2.0 and 1.1
Expansion slot 2 Optional Plugin 2 Optional Plugin
Battery rechargeable rechargeable
Real Time Clock yes yes
Voltage 18-32VDC (*) 18-32VDC (*)
Current rating (at 24VDC) 1.2A 1.4A
Weight 2.8 Kg 3.5 Kg
(*) For applications requiring compliance with EN 61131-2 and specically in reference to 10 ms voltage dips, the
minimum power supply voltage is 18Vdc,

14
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
4.1 Dimensions
4 Technical Data
MODEL A B C D E F
eTOP504 149mm/5.86” 109mm/4.29” 136mm/5.35” 96mm/3.78” 56mm/2.40” 4mm/0.16”

15
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
4.1 Dimensions
4 Technical Data
MODEL A B C D E F
eTOP506 187mm/7.36” 147mm/5.79” 176mm/6.90” 136mm/5.35” 47mm/1.85” 4mm/0.16”
eTOP507 187mm/7.36” 147mm/5.79” 176mm/6.90” 136mm/5.35” 47mm/1.85” 4mm/0.16”
eTOP507M 187mm/7.36” 147mm/5.79” 176mm/6.90” 136mm/5.35” 47mm/1.82” 4mm/0.16”
eTOP510 287mm/11.30” 232mm/9.13” 276mm/10.86” 221mm/8.70” 56mm/2.20” 4mm/0.16”
eTOP512 336mm/13.22” 267mm/10.51” 326mm/12.83” 256mm/10.07” 56mm/2.20” 4mm/0.16”
eTOP513 336mm/13.22” 267mm/10.51” 326mm/12.83” 256mm/10.07” 56mm/2.20” 4mm/0.16”
eTOP515 392mm/15.43” 307mm/12.08” 381mm/15” 296mm/11.65” 60mm/2.36” 4mm/0.16”

16
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
The equipment is not intended for continuous exposure to direct sunlight.
This might accelerate the aging process of the front panel lm.
The equipment is not intended for installation in contact with corrosive chemical compounds. Check the
resistance of the front panel lm to a specic compound before installation.
Do not use tools of any kind (screwdrivers, etc.) to operate the keyboard of the panel or the touch screen.
In order to meet the front panel protection classications, proper installation procedure must be followed:
•the borders of the cutout must be flat
• screw up each xing screw until the plastic bezel corner get in contact with the panel.
•the cutout for the panel must be of the dimensions indicated in this manual.
The IP66 is guaranteed only if:
• max deviation from the plane surface to the cut-out: O0.5mm
• thickness of the case where is mounted the equipment: from 1,5mm to 6mm
• max surface roughness where the gasket is applied: O120 um
Applying the rectangular gasket
The gasket should be applied on the rear of the frame.
A. Gasket
B. Installation cut-out
4 Technical Data
4.2 Installation Environment
Fig. 4.1: eTOP504, eTOP506,
eTOP507, eTOP507M
Fig. 4.2: eTOP510, eTOP512,
eTOP513, eTOP515

17
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
4.3 Installation Procedure
Place the xing brackets as shown in gure (Fig. 4.3).
Fig. 4.3
4 Technical Data
CAUTION
Screw each xing screw until the bezel corner gets in contact with the panel

18
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
1. Serial Port
2. 2x Ethernet Port
3. USB Port
4. Power Supply
5. Expansion slot for Plugin module
6. SD Card Slot
Fig. 5.1 - eTOP504
5 Connections

19
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
1. Serial Port
2. 2x Ethernet Port
3. USB Port (version 2.0 - 1.1)
4. USB Port (version 2.0 High speed only)
5. Power Supply
6. 2x Expansion slot for Plugin module
7. SD Card Slot
Fig. 5.2 - eTOP5xx
5 Connections

20
MANUGENETOP5xx - Version 2.00
© 2018 EXOR International S.p.A. - Subject to change without notice
The serial port is used to communicate with the PLC or with another type of controller.
Different electrical standards are available for the signals in the PLC port connector: RS-232, RS-422, RS-485.
Pin Description
1 GND
2
3 CHA-
4 CHB-
5
6 +5V output
7 CHB+
8 CHA+
9
The serial port is software programmable. Make sure you select the appropriate interface in the program-
ming software.
The communication cable must be chosen for the type of device being connected.
SERIAL PORT
Pin Description
1 GND
2
3 TX
4 RX
5
6 +5V output
7 CTS
8 RTS
9
RS-232 RS-422, RS-485
5 Connections
5.1 Serial Port
Other manuals for UniOP eTOP 500 Series
2
This manual suits for next models
10
Table of contents