Extech Instruments WTH600-E User manual

Other Extech Instruments Weather Station manuals

Extech Instruments RH520A User manual

Extech Instruments

Extech Instruments RH520A User manual

Extech Instruments RHM16 User manual

Extech Instruments

Extech Instruments RHM16 User manual

Extech Instruments WTH600 User manual

Extech Instruments

Extech Instruments WTH600 User manual

Extech Instruments 445703 User manual

Extech Instruments

Extech Instruments 445703 User manual

Extech Instruments WTH600-KIT User manual

Extech Instruments

Extech Instruments WTH600-KIT User manual

Popular Weather Station manuals by other brands

Bresser 7000016000000 instruction manual

Bresser

Bresser 7000016000000 instruction manual

Auriol AHFL 433 A1 operating instructions

Auriol

Auriol AHFL 433 A1 operating instructions

Hyundai WS 2202 instruction manual

Hyundai

Hyundai WS 2202 instruction manual

NexSens G2-HYDROMET quick start

NexSens

NexSens G2-HYDROMET quick start

IROX HBVR761 UV-X user manual

IROX

IROX HBVR761 UV-X user manual

La Crosse Technology C86371 instruction manual

La Crosse Technology

La Crosse Technology C86371 instruction manual

ADE WS 1711 operating instructions

ADE

ADE WS 1711 operating instructions

WAREMA EWFS Weather station eco Operating and installation instructions

WAREMA

WAREMA EWFS Weather station eco Operating and installation instructions

Auriol z29592 Operation and safety notes

Auriol

Auriol z29592 Operation and safety notes

Auriol 296289 Operation and safety notes

Auriol

Auriol 296289 Operation and safety notes

Hyundai WS 2266 instruction manual

Hyundai

Hyundai WS 2266 instruction manual

La Crosse Technology WS-2210 Operation manual

La Crosse Technology

La Crosse Technology WS-2210 Operation manual

La Crosse Technology WS-811561 manual 

La Crosse Technology

La Crosse Technology WS-811561 manual 

Ventus W177 owner's manual

Ventus

Ventus W177 owner's manual

National Geographic VA Colour RC instruction manual

National Geographic

National Geographic VA Colour RC instruction manual

Instant Transmission MA 10410 instruction manual

Instant Transmission

Instant Transmission MA 10410 instruction manual

Lutron Electronics PHB-318 Operation manual

Lutron Electronics

Lutron Electronics PHB-318 Operation manual

Oregon Scientific Alizé BAR266 user manual

Oregon Scientific

Oregon Scientific Alizé BAR266 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

USER MANUAL
WTH600-E WIRELESS WEATHER STATION
WITH WIRELESS TRANSMITTER SENSOR
FOR USE IN EU and UK ONLY
1. INTRODUCTION
Thank you for selecting the Extech WTH600-E Wireless Weather Station with 5-in-1 wireless
sensor. The sensor includes a self-emptying rain collector for measuring rainfall, an anemometer
for wind velocity, a wind vane for wind direction, a temperature sensor, and a relative humidity
sensor. The WTH600-E comes fully assembled and calibrated for convenience. The sensor transmits
data up to 492 ft. (150m), line of sight, to the main display unit via low power radio frequency. The
main unit displays all of the weather data received from the sensor and the user can recall stored
weather data (24-periods). Includes Radio Controlled Clock feature (MSF/DCF). The WTH600-E is a
powerful and unique personal weather station that, with proper use, will provide years of reliable
service.
FEATURES
Radio Controlled Clock (MSF/DCF)
HI/LO Alarms alert the user when programmed weather limits are exceeded
Barometric pressure is computed and helps forecast the weather and possible storms
Min/Max feature includes date/time stamp
View Rainfall rate and daily/weekly/monthly amounts
Wind-speed levels are shown expressed in Beaufort scale
Wind-chill, Heat Index, Dew point, and Comfort level are computed and displayed
WTH600
-
E
WTH600
-
E
www. .com information@itm.com1.800.561.8187
EU/UK Version 2 WTH600-E-en-GB_v1.0 4/18
CONTENTS
1. INTRODUCTION 1
2. PHYSICAL DESCRIPTIONS 3
3. DISPLAY DESCRIPTIONS 5
4. SENSOR INSTALLATION, BATTERIES, MOUNTING 7
5. MAIN UNIT OPERATION, BATTERIES, MOUNTING 9
6. WEATHER FORECAST 11
7. BAROMETRIC / ATMOSPHERIC PRESSURE 11
8. RAINFALL 12
9. WIND SPEED / DIRECTION 13
10. BEAUFORT SCALE 13
11. WIND CHILL / HEAT INDEX / DEW POINT 14
12. HISTORICAL DATA (PRIOR 24 HOURS) 15
13. MAXIMUM / MINIMUM MEMORY 15
14. HI / LO WEATHER ALERT 16
15. WIRELESS SIGNAL RECEPTION 16
16. TEMPERATURE/HUMIDITY COMFORT LEVELS 17
17. CLEARING STRAY READINGS 17
18. POINTING SENSOR TO THE SOUTH 17
19. MOON PHASES 18
20. CLEANING 18
21. TROUBLESHOOTING 19
22. PRECAUTIONS 19
23. FCC STATEMENT Error! Bookmark not defined.
24. SPECIFICATIONS 19
www. .com information@itm.com1.800.561.8187
www. .com information@itm.com1.800.561.8187
www. .com information@itm.com1.800.561.8187
EU/UK Version 5 WTH600-E-en-GB_v1.0 4/18
3. DISPLAY DESCRIPTIONS
Main Display
1. Max/Min/Previous indicator
2. Low battery indicator for main unit
3. Time
4. Ice pre-alert on
5. RC Signal strength indicator
6. DST icon
7. Moon phase
8. Day of the week
9. Alarm icon
10. Date
11. Month
Indoor Temperature/Humidity Display
1. Comfort/cold/hot icon
2. Indoor indicator
3. Indoor humidity
4. Hi / Lo Alert and Alarm
5. Indoor temperature
www. .com information@itm.com1.800.561.8187
EU/UK Version 6 WTH600-E-en-GB_v1.0 4/18
Outdoor Temperature/Humidity Display
1. Outdoor signal strength indicator
2. Outdoor indicator
3. Outdoor humidity
4. Hi / Lo Alert and Alarm
5. Outdoor temperature
6. Low battery indicator for sensor
12+ Hour Forecast Display
1. Weather forecast indicator
2. Weather forecast icon
Barometer Display
1. Barometer indicator
2. Histogram
3. Absolute/Relative indicator
4. Barometer units (hPa / inHg / mmHg)
5. Barometer reading
6. Hourly records indicator
Rainfall Display
1. Rainfall indicator
2. Time range record indicator
3. Day records indicator
4. Histogram
5. Hi Alert and Alarm
6. Current rainfall rate
7. Rainfall unit (in / mm)
www. .com information@itm.com1.800.561.8187
EU/UK Version 7 WTH600-E-en-GB_v1.0 4/18
Wind Direction/Wind speed
1. Wind direction indicator
2. Wind direction indicator(s) during last
hour
3. Current wind direction indicator
4. Wind speed indicator
5. Wind levels and indicator
6. Beaufort scale reading
7. Current wind direction reading
8. Average/Gust wind indicator
9. Wind speed units (mph, m/s, km/h, knots)
10. Hi Alert and Alarm
Wind Chill/ Heat index/ Indoor Dew point
1. Wind chill/ Heat index/ Indoor dew point
indicator
2. Wind chill/ Heat index/ Indoor dew point
reading
4. SENSOR INSTALLATION, BATTERIES, MOUNTING
Wireless Sensor
The wireless sensor measures wind-speed, wind-direction, rainfall, temperature and humidity. The
sensor ships fully assembled and calibrated for easy installation.
Battery and installation
Unscrew the battery door at bottom of unit and insert the batteries
according to +/-Screw the battery door
compartment on tightly. Note:
1. Align the watertight O-ring to ensure water-resistance.
2. The red LED will begin flashing every 12 seconds.
Never dispose of used batteries or rechargeable batteries in
household waste. As consumers, users are legally required to take
used batteries to appropriate collection sites, the retail store where the batteries were
purchased, or wherever batteries are sold.
Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end-of-life
devices to a designated collection point for the disposal of electrical and electronic equipment.
www. .com information@itm.com1.800.561.8187
EU/UK Version 8 WTH600-E-en-GB_v1.0 4/18
Install the wireless sensor in an open location with no obstructions above and around the sensor
for accurate rain and wind measurement. Install the sensor with the smaller end facing to the
North (proper orientation of the wind direction vane). Secure the mounting stand and bracket
(included) to a post or pole, and allow a minimum distance of 1.5m off the ground.
Mounting guidelines
1. Install the wireless sensor at least 1.5m off the ground for accurate wind measurements.
2. Choose an open area within 150 meters from the Main Unit.
3. Install the wireless sensor as level as possible to achieve accurate rain and wind measurements.
The included leveling device ensures a level installation.
4. Mount the wireless sensor with the wind meter end pointing to the North.
5. Pole mount shown below left and railing mount below right.
www. .com information@itm.com1.800.561.8187
EU/UK Version 9 WTH600-E-en-GB_v1.0 4/18
5. MAIN UNIT OPERATION, BATTERIES, MOUNTING
Battery Installation and Mounting
The WTH600-E can be placed on a desktop or can be wall mounted for easy viewing.
1. Remove the battery door of the main unit.
AA +/-ity marks on the battery compartment.
3. Replace the battery door.
4. Once the batteries are inserted all of the LCD segments will be shown briefly before entering the
radio-controlled time reception mode.
5. The RC clock will automatically start scanning for the radio-controlled time signal in 8 seconds.
Note:
1. If no display appears, press the RESET button using a paper clip or other pointed object.
2. In some cases, you may not receive the signal immediately due to atmospheric disturbance.
Pairing the Sensor with the Main Unit
After insertion of batteries, the Main Unit will automatically search for and connect with the
wireless sensor (antenna icon blinking). When successful, the antenna icon and readings for
outdoor temperature, humidity, wind speed, wind direction, and rainfall will appear on the display.
Manual Pairing after Replacing Batteries
batteries, you must perform a manual pairing.
1. Replace the batteries.
2. Press the [SCAN] button.
3. Press the [RESET] button on the sensor (bottom of sensor).
Note:
1. Pressing [RESET] generates a new code for pairing purposes.
2. Please dispose of batteries in an environmentally safe manner and in accordance with all
relevant law and regulations.
Radio-controlled (RC) Time Signal
When the unit receives the RC signal (DCF/MSF), a sync-time symbol will appear on the LCD.
Note that the unit synchronizes daily.
Note:
1. The strength of the signal from the transmitter tower may be affected by geographical location
or surrounding buildings.
www. .com information@itm.com1.800.561.8187
EU/UK Version 10 WTH600-E-en-GB_v1.0 4/18
2. Always place the unit away from interfering sources such as TV monitors, computers, etc.
3. Avoid placing the unit on or next to metal plates.
4. Enclosed areas such as airports, basements, or factories are not recommended.
Setting the Date and Time
The unit automatically sets itself accordingly to the Radio Controlled Clock signal it receives. To set
the clock/calendar manually, first disable the reception as explained in the One-Time and
Permanent Disable sections below and then continue with the steps in the next section.
Manually Setting the Clock and Time Zone
2. Use [UP] [DOWN] buttons to adjust, and press [CLOCK] button to continue.
3. Repeat step 2 above for TIME ZONE (North America version only), HOUR, MINUTE, SECOND,
YEAR, MONTH, DATE, and HOUR OFFSET.
Note:
1. If no buttons are pressed within 60 seconds, the unit will automatically exit this setting mode.
2. The HOUR OFFSET range is ± 23 hours. Adjust the offset accordingly to match the DCF/MSF
signal if necessary.
3. The time zone setting applies only to the North American version where the unit is set to receive
the WWVB signal. User can select PST, MST, CST, EST, AST or NST.
4. The language options are English (EN), French (FR), German (DE), Spanish (ES), and Italian (IT).
5. DST (Daylight Saving Time) feature defaults to AUTO. User can set the DST to OFF.
One-Time Disable / Enable RCC Signal Reception
1. Short press the [RCC] button to disable the reception temporarily.
2. Short press the [RCC] button to enable automatic RCC reception.
Permanent Disable / Enable RCC Signal Reception
1. Press and hold [RCC] button for 8 seconds to disable the reception permanently.
2. Press and hold [RCC] button for 8 seconds to enable automatic RCC reception.
www. .com information@itm.com1.800.561.8187