Part No. INST- FSW 08/12 Page 2 of 3
7. From the outside wall, plug the EIE150 Fan into the socket inside the filter box.
8. Install the filter ensuring the filter lines run vertically and twist the P-clips 90 degrees to lock
it in place.
9. Reinstall the backing plate.
10. Plug external filter box lead into 240V AC power point.
Safety Considerations:
1. All connectionsmust be in accordance with any local regulations.
2. The Licensed Electrical installer must ensure that an approved means of disconnection be incorporated into the fixed
wiring.
3. This fan hasan automatic thermal cut-out switch incorporated in themotor as standard.
4. This productis not intendedfor use by persons (including children) with reduced sensory ormental capabilities, or lack
of experience and knowledge, unless they have been given supervisionor instructionconcerning use of the product by a
person responsible for their safety. Childrenshould be supervised to ensure that they do not play with theproduct.
5. For duct or partition mount, precautions must be taken to avoid the back-flow of gases intothe room from the open flue
of gas or other open-fire appliances.
6. If the supply cord is damaged it must be replaced by the manufacturer,its service agent orsimilarly qualified persons in
order to avoida hazard.