ADVANCED FUNCTIONS
MONITORING HOW MANY HOURS THE HEATING STAYS ON
MINIMUM AND MAXIMUM ROOM TEMPERATURE ON THE PREVIOUS DAY
We reserve the right to make any technical and structural changes deemed necessary without prior notice.
TERMINAL BOARD AND CONNECTIONS
FITTING AND CHANGING THE BATTERIES
Lift the cover and fit two 1.5V batteries
SELECTING THE OFF OR OFF+ANTIFREEZE
PROTECTION MODES
DISTANCE BETWEEN CENTERS FOR FIXING
THE BASE A= for rectangular
flush-mounted boxes
type 503 (three modules)
B= for round flush-
mounted boxes
LOOSEN THIS
SCREW AND TURN
THE BODY OF THE
CONTROLLER
UPWARDS TO
DETACH THE BASE
FOR FIXING TO THE
WALL.
Move the switch Sto the. position
Move the switchPto thePROGposition
Read the hours of heating on the previous day
Read the hours of heating since the controller was
enabled.
With Intellitherm C75 you can also keep a check on the
minimum and maximum temperatures recorded in the room
on the previous day and the time when they occurred.
Move the switch S to the (economy) position
for the MINIMUM temperature or to the
1 -WALL MOUNTING
Intellitherm C75 is supplied complete with a base
suitable for mounting flush in a rectangular three-
module or a round outlet box, or for attaching to the
wall.
Fit the controller 1.5 m above floor level, well away
from kitchens, sources of heat, doors or windows.
Make sure that the base is attached on a level and
without any straining.
2 -ELECTRIC CONNECTIONS
Connect terminals 1 - 2 to the heating system with
two wires, replacing the conventional thermostat at
any time, without adding any further connections.
When the room temperature increases, the relay
opens terminals 1 - 2 and closes1 - 4.
Terminal 4is free and can be used for signals or
other purposes.
3 -
4 -
5 -
SELECTING THE OFF MODE
During periods when it is
OFF,
Intellitherm can be set
to maintain a temperature setting of 5 °C to protect
the system from the risk of freezing.
If you require such ANTIFREEZE protection,
position the dip switch (situated at the bottom left-
hand side on the back of the body of the C55) on
HIGH. If, on the other hand, you want the system to
be switched OFF completely, position the dip switch
on LOW.
This selection must be made at the time of
installationand before fitting the batteries.
NOTE: if, at any time after installation, you wish
to change this selection, the Intellitherm must be
reset and reprogrammed.
FITTING THE BODY OF THE TEMPERATURE
CONTROLLER ON THE BASE
FITTING THE BATTERIES
Insert two good-quality, alkaline long-life AA 1.5 V
pencil batteries in the space provided, taking care to
comply with the polarity indicated. The batteries can
last about two years; when they begin to run down,
the battery symbol on the display starts to flash
If the batteries are not changed within 15 days,
Intellitherm C55 will automatically switch off and only
the wordOFF will appear on the display.
comfort) position for the MAXIMUM
temperature
Read the time when said minimum or maximum temperature was
recorded
Read the minimum or maximum room temperature
Move the switch P to the PROG position
TECHNICAL FEATURES
-In compliance with the CEI EN 60730-1 and parts two
-Terminal carrying capacity 8 (5) A 250 Vac
-Micro-disconnection (1BU)
-No-load switching contact
-Temperature control:
-Comfort from 2 to 62 °C
-Economy from 2 to 62 °C
-Differential ± 0.25 °C
-Reference thermal gradient 4° K/h
-OFF mode with optional antifreeze protection (5 °C)
Selected by means of a dip switch
-double insulation
-Protection grade IP 20 (normal pollution)
-Powered by 2 alkaline AA 1.5V pencil batteries, with
no connection to the mains
-Battery life two years approx.
-Automatic monitoring of battery charge with signal on
display when battery is low
-Battery changing without losing previously-
memorized programs
-Switch for summer/winter operating modes
-Reset button for restoring standard program
-Overall dimensions: 120 x 80 x 27 mm
2004/03
1
2
3
4
2
3
4
1
ANTIFREEZ (5°C)
OFF
C75
83,5 mm
60 mm
A -
B -
2
1
4
4 1 2
P
S
P
S
SUMMER - AIR CONDITIONING OPERATION
When you move the switch I to the SUMMER position, Intellitherm
switches to operating the AIR CONDITIONING system. The red knob is used for
adjusting the comfort mode temperature required in the room, while the economy
and antifreeze modes are disabled.
The red sectors on the ring appearing on the display consequently indicate the
hours when the air-conditioning system is in operation, while the sectors in any
other color indicate when it is off.
I
C55
C75
WEEKLY TEMPERATURE CONTROLLER
Via dell'Osio, 6 20090 Caleppio di Settala MI
International calls Tel.++39 02 95682222
Fax.++39 02 95307006
E-mail: [email protected]
Http//www.fantinicosmi.it
CUSTOMIZING THE (PROGRAMMING)Intellitherm C75
5
6
21
FUNCTION
1
2
3
USING INTELLITHERM C55 WITH THE STANDARD PROGRAMS
i.e. with the default schedules and temperatures already programmed at the factory
1
822,30
8,30 221713,3011,306,30
20
17
5
°C 20
17
5
°C
From Monday (Day 1) to Friday (Day 5)from Saturday (Day 6) to Sunday (Day 7)
D
H
5
4
THE DISPLAY Intellitherm C75
THE OTHER PROGRAMSIntellitherm C75
OFF
OFF
At all times, the display shows the room temperature, the actual time of day
and day of week, whether there is any demand for heating (or for
conditioning in summer) andthe batterylow signal . Thedisplay
also shows a programming ring that represents a 24-hour clock, divided into
48 sectors, each corresponding to half an hour. Each sector is further divided
in half and colored red, red-and-black, or black (depending on the program
selected). The color of the sectors indicates the type of temperature
programmed for that particular time of day, i.e.
- red =comfort temperature
- half red and half black = economy temperature
- black =off.
Make sure that the
switch Iis low, on the
winter position
Make sure that the
switch Pis low, on the
AUTO (automatic)
position
OFF- this keeps the system constantly off or with the antifreeze protection option enabled,
depending on the choice made at the time of installation
(see previous page).
ALWAYS ECONOMY - this constantly maintains the economy mode temperature
selected by means of the blue buttons.
ALWAYS COMFORT
- this constantly maintains the comfort mode temperature selected
by
means of the red buttons.
Programming the Intellitherm C75 is extremely straightforward. All you have to do is change the
color of the sectors on the ring that coincide with the schedules you require, i.e.
- red for the hours when you want the comfort mode temperature
- red and black for the hours when you want the economy mode temperature
- black for the hours when you want the system switched off.
To change the color of the sectors, simply follow the numbered steps below.
After programming the times of day, press button Dto
change the day and repeat the previous steps for all the
other days of the week. If the program for one day is also
suitable for the subsequent days, copy it by pressing the
button C(copy). The day moves on by one unit and the
previously-memorized schedule is copied onto the next
day.
After completing all the changes, bring the switch P into the
AUTO position.
With Intellitherm C75, you can temporarily cut
out the automatic program at any time, without
losing it, in order to obtain a given temperature
(comfort, economy, off) continuously for an
interval ranging from 1to 240 hours.
Put the switch S on the AUTO position
Put the switch P on the AUTO position
Press the red or blue or black buttons to establish the
number of hours (shown on the display) during which time
you want to cut out the automatic program and
temporarily "force" the comfort or economy or off
mode. The ring on the display will turn the color
corresponding to the temperature you have selected.
Move the switch S to the AUTO position for operation with the automatic standard weekly
program with the default schedules and temperatures already programmed at the factory.
After installing and wiring up the C55, simply follow the numbered steps specified below.
=ANTIGELO MODE
=ECONOMI MODE
=COMFORT MODE
Place the switch Phigh, on the
PROG (programming)
position.
The display will indicate 00.00
hours and day1.
The flashing cursor on the ring
will automatically come into
position on the first sector after
the 24 hours.
Move the switch S to the AUTO position
keys
you
on the
ring corresponding time
will appear on the display.
P
S
CDP
S
H
P
3Move the flashing
cursor (forwards or
backwards) around the
Ring with the aid of the
The sector whose color
want to change will flash
and the
cursor
sector
the
hour;
24
22
20
18
16
14 12 10
8
6
4
2
C
DAY
DAY
C
24
22
20
18
16
14 12 10
8
6
4
2
D
H
buttons H
Select the actual day of the week using the button
OF THE
others.
Wednesday -
7 =Sunday).
6
7Adjust the actual time using the
SETTING THE ACTUAL TIME AND DAY
WEEK
These steps can also be taken before all the
D (1 = Monday - 2 = Tuesday - 3 =
4 = Thursday - 5 = Friday - 6 = Saturday -
I
P
S
3
2
Using the blue buttons, adjust
the ECONOMY mode
temperature. The display will
show the temperature setting
instead of the room
temperature.
Reset button. By holding this
down for a few seconds with the
tip of a tool, you can zero all
programming operations and
restore the standard program.
Using the red buttons, adjust
the COMFOR t mode
temperature. The display will
show the temperature setting
instead of the room
temperature.
WILD CARD
use:
-the red buttons for a red
-the blue buttons for a half red
black
4Press the buttons
to color the
sectors On the
ring.
Each time you press one of
three buttons, the sector
becomes colored and the
moves forward by half an
and half black sector
-the black buttons for a
sector .
To move the cursor
without changing the
color of a sector, use the
buttons.

Other manuals for Intellitherm C75

1

This manual suits for next models

1

Other Fantini Cosmi Temperature Controllers manuals

Fantini Cosmi CH180K2 User manual

Fantini Cosmi

Fantini Cosmi CH180K2 User manual

Fantini Cosmi CH180K3 User manual

Fantini Cosmi

Fantini Cosmi CH180K3 User manual

Popular Temperature Controllers manuals by other brands

CARLO GAVAZZI T2000P Series manual

CARLO GAVAZZI

CARLO GAVAZZI T2000P Series manual

Sorel STDC  V1 Installation and operating instructions

Sorel

Sorel STDC V1 Installation and operating instructions

Vaillant VRC 400 Operating and OPERATING AND INSTALLATION Manual

Vaillant

Vaillant VRC 400 Operating and OPERATING AND INSTALLATION Manual

Ropex CIRUS UPT-606 operating instructions

Ropex

Ropex CIRUS UPT-606 operating instructions

ABB i-bus KNX product manual

ABB

ABB i-bus KNX product manual

Gemo LT102HT quick start guide

Gemo

Gemo LT102HT quick start guide

La Crosse Technology Alerts TX60U-IT quick start guide

La Crosse Technology

La Crosse Technology Alerts TX60U-IT quick start guide

Sorel TDC 5A Installation and operating instructions

Sorel

Sorel TDC 5A Installation and operating instructions

Siemens RDE10.1DHW operating instructions

Siemens

Siemens RDE10.1DHW operating instructions

iQe CP027 installation instructions

iQe

iQe CP027 installation instructions

Auber Instruments WSD-1510GPH quick guide

Auber Instruments

Auber Instruments WSD-1510GPH quick guide

Nestbox B1BBH user guide

Nestbox

Nestbox B1BBH user guide

AFRISO FTM T operating instructions

AFRISO

AFRISO FTM T operating instructions

Automationdirect.com SOLO SLM Series user manual

Automationdirect.com

Automationdirect.com SOLO SLM Series user manual

Daikin OM-SLM-0501 Operation manual

Daikin

Daikin OM-SLM-0501 Operation manual

Cryo-con 24C user guide

Cryo-con

Cryo-con 24C user guide

CD Automation Revo TC 2ph user manual

CD Automation

CD Automation Revo TC 2ph user manual

AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE... instruction manual

AMX

AMX AXC-TEMP AND RTS-1 TEMPERATURE CONTROL CARD AND ROOM TEMPERATURE... instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.