La Crosse Technology Alerts TX60U-IT User manual

La Crosse Alerts™
TX60U-IT with Threaded Wet Probe
TX60U-IT temperature and humidity sensor measures:
(A) Ambient air temperature and humidity (Channel 1)
(B) Probe temperature (Channel 2): **Use the optional 6 Ft. detachable
temperature probe to measure water (Wet probe only), soil, air, etc.
This Stainless Steele 1/8 inch Fine Pipe Threaded Probe on a 6 foot wire allows
you to just set the probe in soil, water, etc. for measurement or secure the probe
wire with through a hole with the 1/8 inch Fine Pipe Thread, to prevent movement.
The sensor sends the temperature and humidity measurements to your existing
La Crosse Alerts™ Gateway (not included) with a wireless range of over 200 Ft.
(60.96 m). The Gateway uses your high-speed Internet connection to upload the
temperature and humidity measurements to your included
www.lacrossealerts.com account. Once set up, you can login to your account and
view your temperature and humidity sensor(s) with an Internet-connected mobile
device, tablet or computer with a web browser.
MONITORING OPTIONS
Note: The sensor case is weather resistant, not water proof. The sensor case
cannot get wet, and may be affected by high humidity conditions. **The optional
Wet probe is designed to measure wet environments like a pool or aquarium.
Humidity monitoring*:
oPianos and other musical instruments
oGreenhouses
oReptile terrariums
oCigar storage/humidors
oAllergies (dust mites & mold)
oLaundry rooms and basements at
rental properties or vacation homes
Storage conditions (temperature and humidity)*:
oR.V. storage
oWarehouses
oLong-term storage
Temperature monitoring using optional detachable Wet probe*:
oPools, spas hot tubs
oAquariums, terrariums and other pet care
oBird baths
oHome beer brewing
Temperature monitoring using optional detachable Dry probe*:
oRefrigerators, freezers, laundry rooms and
basements at rental properties or vacation homes
oFood service
oComputers/ server rooms
oSoil temperature using probe:
oFarms
oGardens
oGreenhouses
* Disclaimers: La Crosse Technology, LTD. (“La Crosse”) provides various alert
and monitoring services to aid users. (1) Service providers may charge users for
alert services. Standard messaging and data rates apply and will be billed to the
customer’s wireless account. Customers may be unable to receive text
messaging or data service in some areas due to unavailability of service. (2) La
Crosse shall not be liable for accuracy, usefulness or availability of data
transmitted via the service. Users are solely responsible for damages to persons
or property by service use. (3) La Crosse shall not be liable for any damages or
warranty issues that may incur from altering property (plumbing) to accommodate
the temperature monitoring hardware. Users are solely responsible for damages
to persons or property by use of the hardware installation kit.
PACKAGE CONTENTS
1. TX60U-IT Wireless temperature and humidity sensor
2. Mounting hardware
3. Instruction manual
4. Activation key card (IMPORTANT for set up. Do not throw away)
5. 6 ft. Temperature Probe wire with threaded stainless steel probe
(1/8 inch Fine Pipe Thread)
ADDITIONAL EQUIPMENT (NOT INCLUDED)
Internet Gateway, AC adapter and LAN cable are not included (sold
separately).
Two fresh AAA, IEC LR03, 1.5V Alkaline batteries
Browser with high speed Internet
Internet Gateway, AC adapter and LAN cable are not included
Network router
Aluminum tape
OPTIONAL CHANNEL 2 PROBE (Wet Probe or Dry
Probe)
If the optional probe for the temperature and humidity sensor is unplugged, the
LCD on the temperature and humidity sensor will display "nC" for the CHANNEL
2 reading. **A wet or dry probe can be plugged into the sensor at any time
without resetting the units.
ACTIVATION
See the Activation Card in the package for setup instructions and the Activation
Key. The Activation Key is necessary to activate your sensor and Gateway.
Please keep your Activation Card for reference.
Account creation and product activation at:
www.lacrossealerts.com
If you have lost your Activation Card with the
Activation Key, please contact customer support for
assistance:
Support:
www.lacrossetechnology.com/support/alerts
Phone: (608) 785-7920
1 YEAR OF ENHANCED SERVICE WITH ALERTS AND 4 YEARS OF BASIC
SERVICE ARE INCLUDED WITH YOUR ACTIVATION KEY
Once the Gateway and sensor is activated on your www.lacrossealerts.com
account, you can monitor your sensors online and set up custom e-mail and text
message alerts*.
MEASUREMENT LOG DOWNLOAD
Once the sensor is activated and building a measurement log, you can download
the data as a comma separated values (CSV) file. You must use an application
such as Microsoft Excel® or Google Docs® that supports comma separated
values (CSV) formatted files to view the table data.
IMPORTANT SETUP & OPERATION NOTES
The sensor should be placed in a dry, shaded area. Please avoid a
location with direct sun, as that will cause incorrect readings.
Fog and mist will not harm the sensor but direct rain must be avoided.
Note: Exposing the sensor case to extreme humidity may temporarily
disrupt data. The sensor case reads humidity, but should not be
submerged in water. **Attach a 6 ft. wet probe to measure water
temperature.
The sensor has a wireless range of 200 feet (60.96 m). Keep in mind that
the 200 ft. range equates to open air with no obstructions, and that radio
waves DO NOT curve around objects. Actual transmission range will vary
depending on what is in the path of the signal. Each obstruction (roof,
walls, floors, ceilings, thick trees, etc.) will effectively cut signal range in
half.
Metal siding, stucco, and some types of glass can reduce signal range by
as much as ¾ or more, compared to the ½ reduction typical of most
obstructions. It is possible to receive a signal through these materials,
however maximum range will be reduced due to their tendency to absorb or
reflect a much larger portion of the sensor’s signal.
(B)
(A)
**Optional external probe included in select packages
(Wet and Dry probes are also sold separately)
This socket is ONLY
for the external probe.
DO NOT insert
power plug into it.
LCD
Button
1/8 inch fine pipe
thread probe with
6 foot wire that can
plug into sensor.
The sensor measures and updates the temperature and humidity on the
LCD every 6 seconds. Note: The new measurement is reported to your
account at intervals that you select using your online account.
BATTERY REPLACEMENT
1. Remove the battery cover by sliding the cover down.
2. Observing the correct polarity install 2 AAA batteries. The batteries will fit
tightly (to avoid start-up problems make sure they do not spring free).
3. Do not mix old and new batteries.
4. Do not mix alkaline, lithium, standard or rechargeable batteries.
5. Replace the battery cover by sliding upwards.
Be sure battery cover is on securely.
LOW BATTERY INDICATOR
When batteries are low, the low battery indicator shows up on the LCD. You will
receive an e-mail or mobile text message alert when the batterypower of the
sensor is low. Change the batteries immediately.
Note: The LED turns ON briefly after changing batteries. The LED turns OFF
when not needed to save battery power. The previously stored information in the
sensor will not be affected or cancelled while you change the batteries.
MOUNTING
Select a location where the transmitter may be installed.
Protected from water and rain as the transmitter is water resistant not water
proof.
Within range of the wireless gateway (see “IMPORTANT SETUP & OPERATION
NOTES”).
If mounting within the control area of a hot tub, mount the transmitter far from
the electrical motor that drives the pumps which create electrical noise that
may interfere with transmission of the temperature signal.
IMPORTANT! TEST the transmitter in the selected mounting location for 1
hour before alterations are made to your property.
Check signal reception to the wireless gateway.
Note:
The sensor can be used without the probe wire for ambient
temperature/humidity.
The probe sensor can be used as a stand-alone product. Simply insert the
probe wire into the water of your hot tub and secure the transmitter in an area
that is protected from water. The transmitter case is water resistant but not
waterproof.
The fine threaded probe sensor can be secured in a bolt hole to prevent
movement.
IMPORTANT: Before inserting the threaded probe into a bolt hole
it is recommended to cover the threads with 3 layers of Teflon
tape (not included).
*CAUTION!* Do not alter or change your property until you have
considered all options for installation. Assess your specific hot
tub/spa construction to determine if additional plumbing
supplies (not included) would be needed to install the probe.
La Crosse Technology is not responsible for alterations made by
the homeowner to their property.
Select what temperature you wish to monitor:
Actual water temperature
Heater water temperature
Cabinet temperature
THE TX60U-IT TEMPERATURE & HUMIDITY SENSOR
The sensor can be mounted onto a wall with the use of screws
MOUNTING WITH SCREWS
1. Remove the mounting bracket from the sensor.
2. Place the mounting bracket over the desired location.
3. Mark mounting surface with a pencil through the 2 holes of the bracket.
4. Screw mounting bracket onto surface and tighten screws to bracket.
5. Insert the sensor into the bracket.
TABLE STANDING AND OTHER MOUNTING OPTIONS
With the mounting bracket installed at the bottom or on the top of the
sensor, the user can place it on any flat surface.
Note: Before permanently fixing the sensor mounting bracket, place
all units in the desired locations to check that the outdoor
temperature & humidity readings are receivable. In event that the
signal is not received, relocate the sensor or move them slightly as this may help
the signal reception.
MAINTENANCE AND CARE
Avoid extreme temperatures, vibration, and shock to prevent damage.
Clean displays and units with a soft, damp cloth. Do not use solvents or
scouring agents; they may mark the displays and casings.
Do not submerge the sensor case in water.
Avoid kinking the temperature probe cable.
Immediately remove all low powered batteries to avoid leakage and damage.
Opening the casings invalidates the warranty. Do not try to repair the unit.
Contact La Crosse Technology® for repairs.
SPECIFICATIONS
Device sensor:
Temperature range:
-40°F to 140°F with 0.2°F resolution
“OFL” displayed if outside this range.
Humidity measuring range:
3% to 99%
Transmission range:
200 feet (60.96 m) in open space
**Optional probe sensor:
Temperature range:
-40°F to 140°F with 0.2°F resolution
“OFL” displayed if outside this range, and
displayed “nC” if probe is not connected.
Power Supply:
Temperature transmitter :
2 x AAA, IEC LR03, 1.5V
Battery life cycle:
Approximately 24 months
Recommended battery type:
Alkaline
Dimensions (H x W x D):
5.23" x 0.76" x 1.44"
WARRANTY INFORMATION
La Crosse Technology, Ltd provides a 1-year limited warranty on this product
against manufacturing defects in materials and workmanship.
This limited warranty begins on the original date of purchase, is valid only on
products purchased and used in North America and only to the original purchaser
of this product. To receive warranty service, the purchaser must contact La
Crosse Technology, Ltd for problem determination and service procedures.
Warranty service can only be performed by a La Crosse Technology, Ltd
authorized service center. The original dated bill of sale must be presented upon
request as proof of purchase to La Crosse Technology, Ltd or La Crosse
Technology, Ltd’s authorized service center.
La Crosse Technology, Ltd will repair or replace this product, at our option and at
no charge as stipulated herein, with new or reconditioned parts or products if
found to be defective during the limited warranty period specified above. All
replaced parts and products become the property of La Crosse Technology, Ltd
and must be returned to La Crosse Technology, Ltd. Replacement parts and
products assume the remaining original warranty, or ninety (90) days, whichever
is longer. La Crosse Technology, Ltd will pay all expenses for labor and
materials for all repairs covered bythis warranty. If necessary repairs are not
covered by this warranty, or if a product is examined which is not in need or
repair, you will be charged for the repairs or examination. The owner must pay
any shipping charges incurred in getting your La Crosse Technology, Ltd product
to a La Crosse Technology, Ltd authorized service center. La Crosse
Technology, Ltd will payground return shipping charges to the owner of the
product to a USA address only.
Your La Crosse Technology, Ltd warranty covers all defects in material and
workmanship with the following specified exceptions: (1) damage caused by
accident, unreasonable use or neglect (including the lack of reasonable and
necessary maintenance); (2) damage occurring during shipment (claims must be
presented to the carrier); (3) damage to, or deterioration of, any accessory or
decorative surface; (4) damage resulting from failure to follow instructions
contained in your owner’s manual; (5) damage resulting from the performance of
repairs or alterations by someone other than an authorized La Crosse
Technology, Ltd authorized service center; (6) units used for other than home
use (7) applications and uses that this product was not intended or (8) the
products inability to receive a signal due to any source of interference.. This
warranty covers only actual defects within the product itself, and does not cover
the cost of installation or removal from a fixed installation, normal set-up or
adjustments, claims based on misrepresentation by the seller or performance
variations resulting from installation-related circumstances.
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR
INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES
ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS
PRODUCT. THIS PRODUCT IS NOT TO BE USED FOR MEDICAL
PURPOSES OR FOR PUBLIC INFORMATION. THIS PRODUCT IS NOT A
TOY. KEEP OUT OF CHILDREN’S REACH.
This warrantygives you specific legal rights. You may also have other rights
specific to your State. Some States do not allow the exclusion of consequential
or incidental damages therefore the above exclusion of limitation may not apply
to you.
For warranty work, technical support, or information, please contact:
La Crosse Technology, Ltd
2817 Losey Blvd. S.
La Crosse, WI 54601
Initial Activation or Add Sensor to Your Account:
www.lacrossealerts.com
If you have lost your Activation Card with the
Activation Key, please contact customer support for
assistance:
Support:
www.lacrossetechnology.com/support/alerts
Phone: (608) 785-7920
For online product information: www.lacrossetechnology.com/alerts
FCC DISCLAIMER
This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including
interference that may cause undesired operation.
All rights reserved. This handbook must not be reproduced in any form, even in
excerpts, or duplicated or processed using electronic, mechanical or chemical
procedures without written permission of the publisher.
This handbook may contain mistakes and printing errors. The information in this
handbook is regularly checked and corrections made in the next issue.
We accept no liability for technical mistakes or printing errors, or their
consequences. All trademarks and patents are acknowledged.
LT04192012

Other La Crosse Technology Temperature Controllers manuals

La Crosse Technology TX4 User manual

La Crosse Technology

La Crosse Technology TX4 User manual

La Crosse Technology LTV-TH3 User manual

La Crosse Technology

La Crosse Technology LTV-TH3 User manual

La Crosse Technology LTV-TH2 User manual

La Crosse Technology

La Crosse Technology LTV-TH2 User manual

La Crosse Technology LTV-TH1 User manual

La Crosse Technology

La Crosse Technology LTV-TH1 User manual

La Crosse Technology WS-7215U User manual

La Crosse Technology

La Crosse Technology WS-7215U User manual

La Crosse Technology Tomorrow's Weather Today TX28U User manual

La Crosse Technology

La Crosse Technology Tomorrow's Weather Today TX28U User manual

La Crosse Technology TX21U User manual

La Crosse Technology

La Crosse Technology TX21U User manual

La Crosse Technology TX4U User manual

La Crosse Technology

La Crosse Technology TX4U User manual

La Crosse Technology TX141TH-Bv3 User manual

La Crosse Technology

La Crosse Technology TX141TH-Bv3 User manual

La Crosse Technology TX6U User manual

La Crosse Technology

La Crosse Technology TX6U User manual

La Crosse Technology CA85169 User manual

La Crosse Technology

La Crosse Technology CA85169 User manual

La Crosse Technology TX141TH-Bv3 User manual

La Crosse Technology

La Crosse Technology TX141TH-Bv3 User manual

La Crosse Technology CA80987 User manual

La Crosse Technology

La Crosse Technology CA80987 User manual

La Crosse Technology CA308148 User manual

La Crosse Technology

La Crosse Technology CA308148 User manual

Popular Temperature Controllers manuals by other brands

Autonics TK4N instruction manual

Autonics

Autonics TK4N instruction manual

Johnson Controls System 350 A350A Technical bulletin

Johnson Controls

Johnson Controls System 350 A350A Technical bulletin

eltherm ELTC-14 operating instructions

eltherm

eltherm ELTC-14 operating instructions

Siemens REV23 user manual

Siemens

Siemens REV23 user manual

Vents RNS-16 user manual

Vents

Vents RNS-16 user manual

Komfovent C5.1 Electrical installation and Operation Manual

Komfovent

Komfovent C5.1 Electrical installation and Operation Manual

dixell IC200CX Series user manual

dixell

dixell IC200CX Series user manual

Siemens SITRANS TS Series operating instructions

Siemens

Siemens SITRANS TS Series operating instructions

Samwon ENG SU-105 instruction manual

Samwon ENG

Samwon ENG SU-105 instruction manual

Titus TAO Installation & operation manual

Titus

Titus TAO Installation & operation manual

RusAutomation NIVELCO TS Series user manual

RusAutomation

RusAutomation NIVELCO TS Series user manual

P.W. KEY RK-2006SPGMS manual

P.W. KEY

P.W. KEY RK-2006SPGMS manual

Proxel DTLED user manual

Proxel

Proxel DTLED user manual

Danfoss EKC 366 manual

Danfoss

Danfoss EKC 366 manual

S+S Regeltechnik THERMASGARD ALTM2 operating instructions

S+S Regeltechnik

S+S Regeltechnik THERMASGARD ALTM2 operating instructions

nvent Raychem Raystat-Control-11-DIN manual

nvent

nvent Raychem Raystat-Control-11-DIN manual

Viconics VTR8300 Series installation guide

Viconics

Viconics VTR8300 Series installation guide

emz smart Sol Assembly and operating instructions

emz

emz smart Sol Assembly and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.