Farho MR Farho User manual

Installation and operation instructions
Technical data - Repeater module MR Farho
Consumption: <1W
RF Band: 868MHz ISM Band
Power Supply: 117~240 VAC, 50/60Hz
Dimensions (Height x Width x Long): 34mm x 50mm x 42mm
Please read carefully this guide and keep it for future reference.
The installation must comply with local regulations.
intelligent heating
MR Farho
repeater module
Thank you for purchasing the MR Farho module. This item has been
manufactured following a quality advanced production process complaining
UNE-EN 60950, UNE-EN 301 489, UNE-EN 61000-6 and UNE-EN 300 220
regulations.
Please read carefully this guide and keep it for future reference.
Place the module MR Farho between the Internet module, MI Farho, and the
area with range problems. It is preferable to place the repeater nearest to the
problematic area than to the MI Farho.
Visit our web site www.farho.com to check all the supported operating
systems and other information about our range of products.
Do not expose this device to rain, moisture, dripping, or
splashing.
The installation must comply with local regulations.
The device shall not be used for critical applications, or that
endanger the safety of people, objects or animals.
1
Important information
Wire the module according to the diagram above and re-connect the electrical
power of the installation.
The green LED on the top of the module must remain ON permanently,
otherwise trty to reset the module by pressing and keeping pressed the
installation button of the module (8) until the green LED starts to blink.
The repeater module must be installed as a Heating module.
Installation
To reduce the risk of electrical shock, serious injury or death,
disconnect the electrical power before wiring the module. The
installation should be carried out by a qualified electrician.
1. Phase 117~240 VAC
2. Neutral 117~240 VAC
3. NC - Not connected
4. NC - Not connected
5. NC - Not connected
6. NC - Not connected
7. NC - Not connected
8. Installation button
2
Module connections Run the Farho-Control app, and go to "Heating" menu. At the bottom bar
select the tab "Configure" (default password is "farho"). Press "Edit zone" and
select any existing zone. Go near to the repeater and in the app press the
"Add modules" button. The app will show the message "Waiting for the
module".
Press now (short press) the installation button of the repeater (8). The app
will show a new module installed and the green LED of the module will turn off.
After installing the repeater it is necessary to do a resynchronization of the
installation.
Go back to the main menu of the app. To resynchronize the app go to the
"Configuration" menu, in iOS you can go to this menu by pressing the top left
gear icon and in Android using the menu button of the device and selecting the
tab "Settings".
Press the Communications button and then the "Resynchronize installation"
button.
- After installing the module, the app will show a new heating module
installed. Do not worry about it, the repeater has NOT been added as a
heating module. Just do a resynchronization of the installation and the app
will show the right number.
- Once a repeater has been installed, there is no need of re-installation, even
if you disconnect and move it to another place inside the installation (unless
you reset the installation or the module).
- The repeater must NOT be the first module installed.
- Make sure the antenna is properly connected before starting the
installation.
Important considerations about the installation
3

During the first 6 months after the purchase date, the guarantee covers the
repair at Farho installations of any manufacturing flaw or defect and any
damages arising of such defect.
During these 6 months, the client may also ask for a replacement free of
charge without having to run with the carriage charges and the labour costs
involved.
If the repair is not satisfactory for the client, the holder of the guarantee has
the right to have the item changed for a new one or even chose to return the
product and ask for a refund.
During the next 18 months, Farho will cover any replacement without any cost
for the client including carrier and labor costs.
After the second year, any electronic flaw can be repaired in Farho´s Technical
Service Department but carrier and labor costs will be charged to the client.
CAUSES EXCLUDED FROM GUARANTEE:
· Breaks provoked by atmospheric or geological phenomena (frosts, storms,
rains…) as well as those arising from inappropriate voltage.
· Parts or components that have received knocks or bumps during carriage or
the fitting operation.
· Cleaning operations of the appliance or parts of it provoked by dirt, grease or
other circumstances related to the premises where the appliance has been
fitted.
· Modifications to original Farho products without consulting the factory or
using spare parts that have not been recommended by Farho.
Warranty conditions
4 5
6
www.farho.com
comercial@farho.com
Tlf. (+34) 985 51 40 82
Fax. (+34) 985 51 41 64
Pol. Industrial Tabaza II, parcelas 9 a 13
33439 Carreño, Asturias, SPAIN
© 2015 Farho Domotica S.L.
intelligent heating
Made in EU