FastIron 400 User manual

FASTIRON400, 800, 1500
The FastIron®400, 800 and 1500 systems are the first in
the industry to provide Enterprise customers with a complete
end-to-end LAN solution—from the wiring closet to the
LAN backbone—based on a single product family. The
JetCore®-enabled FastIron systems simplify sparing, network
operations and administration for dramatic savings inTotal Cost
of Ownership (TCO).
Based on Foundry’s third-generation JetCore ASIC chipset, the
FastIron 400, 800, and 1500 systems deliver incredible port
density, advanced Layer 2/3 feature sets, rich Quality of Service
(QoS), bandwidth management capabilities for Voice over IP
(VoIP) and 10 Gigabit Ethernet interfaces to scale the network
backbone with massive bandwidth capacity.
Highlights
tUnparalleled port density maximizes revenue per rack unit by
minimizing the environmental requirements such as space,power and
cooling. Scale up to 232 Gigabit Ethernet ports,228 Gigabit over
Copper ports,28 10 Gigabit Ethernet ports,or 672 10/100 ports in
a single modular system that occupies up to 17 rack units (RU).
tRich QoS features with wire-speed fine-grain bandwidth management
and a complete multicast feature set provides a superior foundation for
VoIP and next-generation streaming media applications
tAdvanced Layer 2/3 feature set including integrated IP,IPX,
AppleTalk, and OSPF protocols
tState-of-the-artTernary ContentAddressable Memory (TCAM)
delivers wire-speed switching and Policy Based Routing (PBR)
tASIC based sFlow™technology (RFC 3176) support provides
Enterprises with per-port,wire-speed network monitoring for capacity
planning and security analysis
tSuperior high availability with redundant management modules
including temperature sensor,hot-swappable,load-sharing power
supplies, and hot-swappable interface modules
tIronShield™security protects against Denial of Service (DoS) attacks
and prevents unauthorized access to networks and server farms
tJumbo frame support on both Gigabit and 10 Gigabit Ethernet
expands the data payload for network intense data transfer applications
such as Storage Area Networks (SANs)
Enterprise Layer 2 / 3 Switches
1

Superior High Availability
tRedundant, hot-swappable management and interface modules—
rapid fault detection and failover for increase reliability and expandibility
tRedundant, hot-swappable load-sharing power supplies—increased
system reliability and circuit redundancy with the ability to mix AC and
DC power within the same system
tSuperior Layer 2 Redundancy—Rapid SpanningTree Protocol (RSTP)
based on IEEE 802.1w and link aggregation based on IEEE 802.3ad
for rapid convergence,minimal network downtime and minimal packet loss
tLayer 3 Redundancy—VRRP,VRRP-E (Enhanced), andVSRP
for router redundancy
Advanced Layer 2 Features
tExtensive SpanningTree Protocol Features:
—Rapid SpanningTree Protocol based on IEEE 802.1w—
sub-second convergence using a pre-calculated failover link
—Fast Uplink Span—faster convergence on uplink ports on wiring
closet switches in just four seconds
—Single-instance STP—support third-party devices that run a
single STP instance in accordance with the 802.1s specification
—PerVLAN SpanningTree (PVST)—multiple spanning trees
instances within a single system forVLAN load-sharing and
increased network reliability
tDynamicVLANs—simplified network address administration with
logical assignment of users to virtual communities based on port, protocol
or subnet,minimizes broadcast traffic and ensures network security
tLink Aggregation based on IEEE 802.3ad—logical links containing
up to four 100 Mbps or eight Gigabit Ethernet or four 10-GbE links to
scale bandwidth and protect against link,port, or interface module failure
tMirror/Monitor Port—monitoring and troubleshooting of single or
multiple switch ports without disruption to existing traffic flows, aiding
fault isolation
Complete Layer 3 Functionality
tIntegrated Switch Routing (ISR)—reduce dependencies on external
routers allowing network managers to configure a FastIron switch to
route Layer 3 traffic including IP, IPX,AppleTalk, and OSPF protocols
tIndustry Standard Routing Protocol—dynamic IP routing using
RIP and OSPF
—RIP—simple solution for small to medium size network
infrastructures,allowing administrators to assign IP addresses
without defining sophisticated route propagation strategies
—OSPF—flexible route propagation for medium to large enterprise
networks, allowing administrators to pre-determine network paths
for specific traffic, define route summarization properties to minimize
route table overhead,and take advantage of Equal Cost Multi Path
(ECMP) for increased bandwidth utilization and redundancy
tPolicy Based Routing (PBR)—provides customized routing decisions
based on source address allowing Metro customers to maintain single
configurations while having access to different service offerings such as
enhanced security,increased flexibility,and access to preferred ISPs
tNetwork AddressTranslation (NAT)—allows Enterprise networks to
translate private IP addresses into public IP addresses when traversing the
Internet, conserving IP address space and increase network security
2
KeyFeaturesandBenefits
SystemSummary
Feature FastIron 400 FastIron 800 FastIron 1500
Slots 4 8 15
Switching Capacity 128 Gbps 256 Gbps 480 Gbps
Equipped with 10GbE* 101 Mpps 220 Mpps 429 Mpps
Equipped with Gig E* 83 Mpps 178 Mpps 345 Mpps
Max Ports Per System
10/100 ports 144 336 672
Gigabit ports 56 120 232
10 Gigabit ports 6 14 28
Height 8.75" 20.75" 29.75"
Power Supply Redundancy 1+1 N+1 N+1
*Million Packets per second (Mpps) numbers are aggregate based on switching capacities of the line cards

3
VoIP Foundation—Advanced QoS and
Bandwidth Management
tAdvanced QoS—enforce or change traffic priority based on port,VLAN,
source MAC,ACL,802.1p,Type of Service (ToS), or DiffServ settings
to prioritize business-critical flows
tUltra-low Latency—industry-leading port-to-port latency of 10 to
20 microseconds for superior call quality when usingVoIP and other
latency-sensitive traffic such as video
tMultiple Queuing Methods—Strict Priority (SP) orWeighted Fair
Queuing (WFQ) provides flexibility for network administrators in
enforcing traffic prioritization
Scalable Multicast Implementation
tComprehensive Multicast Feature Set—hardware-based multicast
features allow network managers to efficiently deploy streaming media
applications for improved employee collaboration and productivity
tDiverse Multicast Protocol Support—IGMP,DVMRP, MSDP,
PIM-SM (Sparse Mode),and PIM-DM (Dense Mode) give administrators
the flexibility of supporting a variety of applications with complete
interoperability to existing applications
tSuperior Multicast Scalability and Performance—Up to 64,000
Layer 2 Multicast groups with sub-second join and leave latency for
industry-leading multicast performance and scalability
Cohesive, Unified and Easy-To-Use
Network Management
tCentralized Network Management—Foundry’s IronView Network
Manager™is a web-based,graphical interface tool (GUI) that empowers
network operators to seamlessly control software and configuration updates
for any Foundry product from a central station.This dramatically
simplifies network provisioning, diagnostics and resolution,thus reducing
the operational expenses.
tMRP—Managed Rim Protocol for the Enterprise rapidly reconfigures
for network changes that affect the local ring,and with no need for
network-wide reconvergence.This results in dramatically improved performance.
tCommand Line Interface (CLI)—is an industry-standard
configuration interface,consistent and common throughout Foundry’s
entire product portfolio
tWeb Interface—provides easy to use Graphical User Interface
for system configuration from standardWeb browsers
tsFLow (RFC 3176)—provides scalable,ASIC-based,wire-speed
network monitoring and accounting with no impact on network
performance.This allows network operators to gather a variety of
sophisticated network statistics and information for capacity planning
and real-time network monitoring purposes.
IronShield™Security
tWire-speed Extended Access Control Lists (ACL)—control packet
forwarding and restrict access to the system management interface, while
providing wire-speed switching and routing:
—Feature-Rich ACL Implementation—identify traffic based on
source or destination IP address,IP protocol type,TCP or UDP port,
IP precedence, orTOS values
—Selective ACL Logging—collect statistics for packets matching the
deny or permit conditions
—ACL Scalability—support for up to 4,096 ACLs
—Ease of Administration—identify an ACL by name or number,
or add a comment line for ease of administration
—ACL Syntax Compatibility—uniform ACL syntax across all
Foundry products provides compatibility with syntax of other
major vendors
tWire-speed, fine-grain Bandwidth Management—Traffic classification
and bandwidth enforcement based on port,port plus priority,or Layer 4
ACLs, from 1 Mbps up to 1 Gbps in increments as small as 256 Kbps
tMAC access control using either MAC registration or IEE802.1x allows
for controlling unauthorized or untrusted hosts from accessing the network.
Applying dynamically configuredVLANs and Layer 2 filters,or Layer
3/4ACLs further secures the access.Tunneling a link between host client
and a centralized policy server over the 802.1x EAP protcol allows for a
thorough analysis of the host to ensure it is in a trusted state prior to going
access to the network.
tSecure Shell and Secure Copy—provide secure access to the
administration and management interface over the network
tProtection Against Denial Of Service (DoS) Attacks—prevents or
minimizes network downtime and protects against malicious users by
limitingTCP SYN and ICMP traffic and protects against broadcast
storms by limiting broadcast traffic
tUser Authentication—authentication with AAA,802.1x,RADIUS,
TACACS,andTACACS+ to prevent unauthorized network access
tWire-speed Rate Limiting—enforce bandwidth policies to prevent
unauthorized network hogging
tSFlow (RFC 3176)—provides cost-effective,scalable, wire-speed
network monitoring to detect unusual network activity
tSNMPv3—Secured SNMP management with RFC 2570 through
2575,provides User-Based Security model (RFC 2574) for authentication
and privacy services
Industry Leading Performance
tIndustry’s Highest Switching Performance—non-blocking,distributed
switching architecture with a parallel cross-point switch fabric provides up
to 480 Gbps of aggregate switching capacity,and 178 million packets per
second switching performance
tState-of-the-artTCAM—provides wire-speed Layer 2/3 switching
and policy based routing with industry leading switching capacity
and scalability
tJumbo Frames—support for jumbo frames on Gigabit and 10 Gigabit
interfaces allows dramatic scalability in server throughput while
minimizing the impact on server processing resources

FastIron Systems for End-to-End
Enterprise Solution
The JetCore-based FastIron systems are the first in the industry to
provide Enterprise customers with a complete end-to-end LAN
solution, ranging from the wiring closet to the LAN backbone,
based on a single product family. The single JetCore product
family simplifies network operations,administration,and sparing
requirements,leading to dramatic savings inTCO.
The JetCore-based FastIron systems include advanced Layer 2/3
feature sets that deliver industry-leading scalability and
performance,with embedded support for IP,IPX,andAppleTalk
based switching. Integrated fine-grain bandwidth provisioning,
sFlow™(RFC 3176), rich QoS, complete multicast, and jumbo
frames provide a foundation for VoIP and next-generation
streaming media applications.
Complemented by the JetCore-based FastIron 4802 workgroup
switch, the FastIron 400, 800, and 1500 systems empower
Enterprise customers to harness network performance into a
competitive business advantage and improve productivity
by exploiting the efficiencies of intranet, Internet, and
extranet applications.
FastIron 400, 800, and 1500 for
Enterprise Wiring Closets
The FastIron 400, 800, and 1500 modular systems provide an
ideal choice for Enterprise wiring closets.These products offer
superior port density,serviceability,high availability,security and
advanced Layer 2/3 features sets. Redundant management
modules providing rapid failover, IEEE 802.1w based Rapid
Spanning Tree Protocol (RSTP), and ultra-low latency of
5 microseconds delivers the critical high availability and
performance required for mission-critical applications
includingVoIP.
Shipping with full Layer 2 and base Layer 3 capabilities,
the FastIron modular systems can be upgraded to a full
Layer 3 feature set.The easy upgrade path provides Enterprise
customers with a “future-proof ” technology while enabling
interoperability with existing infrastructures.
The addition of new JetCore-base interface modules, including
a 48-port RJ-21 (Telco) auto-sensing 10/100 interface module
and a 16-port Gigabit copper auto-sensing 100/1000 interface
module,provide the industry’s most compact port density while
supporting a smooth migration path for Gigabit-to-the-desktop.
You can swap modules to easily adapt to business needs,without
costly forklift upgrades.
4
ProductDeploymentApplications
Industry Leading Enterprise Solutions
DUAL HOMED
CORE
WIRING CLOSET SERVER FARM
ENTERPRISE BACKBONE
FASTIRON 800 FASTIRON 800
Legend
1Gig
10Gig
10/100
FASTIRON 400
FASTIRON 1500

5
FastIron 400, 800, and 1500 for
Enterprise Server Farm Connectivity
The FastIron 400,800,and 1500 Layer 2/3 switches are ideal for
server farm connectivity, providing cost-effective 100/1000
auto-sensing Gigabit Ethernet over copper interfaces for scaling
server bandwidth.
The 16-port 100/1000 auto-sensing Gigabit over Copper (GoC)
interface module provides industry leading port density up to
232 Gigabit ports in a single system that could take the full 17 rack
units. Jumbo frame support on these cost-effective modules
enables Enterprise customers to reduce CPU cycles during
server farm backup operations.
The JetCore-based FastIron systems also support the new
10 Gigabit Ethernet interface module to scale backbone
connectivity.In addition,Foundry’s IronSheild™security features
protect the server farm against Denial of Service (DoS) attacks
and provide administration security. These security features
eliminate unnecessary network downtime caused by malicious
hacker attacks.
FastIron 400, 800, and 1500 for
Enterprise LAN Backbone
The JetCore-based FastIron systems feature industry-leading
Gigabit and 10 Gigabit port density including fiber and copper
Gigabit and fiber 10 Gigabit Ethernet interfaces, a critical
requirement in the LAN backbone.
Continuing Foundry’s technology leadership, the new FastIron
systems offer wire-speed, non-blocking Layer 3 switching,
delivering the industry’s highest switching capacity of up to 480
Gbps. TCAM technology, an enhancement to Foundry’s
hardware forwarding technology,is a feature of the JetCoreASIC
chipset, which provides superior performance and scalability in
the LAN backbone and data center.
Advanced multicast capabilities,wire-speedAccess Control Lists,
and complete integrated OSPF routing capabilities provide
robust routing and filtering,while 10 Gigabit Ethernet interfaces
or IEEE 802.3ad-based trunk groups enable Enterprise
customers to immediately scale inter-switch connections in the
LAN backbone to meet increasing bandwidth requirements.
Foundry Voice over IP Solutions
Today’s networks are providing services thought impossible just a
few years ago.Internet,e-mail,voice,and video conferencing are
just a few of the business applications that are placing higher
demands upon the network Infrastructure. The standards and
demands for the network infrastructure have never been higher.
Delivering voice solutions requires more than just connectivity.
Issues such as call quality, reliability, availability, security, and
manageability are paramount in the complete voice solution.
Most of all,the solutions should be able to deliver answers to these
issues all while saving scarce budget dollars or enabling new
business possibilities. Foundry Networks believes that the
customer should be able to choose the tools that are right for
their business and strives to build solutions that will enable any
telephony vendor’s solutions to interoperate with Foundry’s
superior network infrastructure equipment.
Foundry Power over Ethernet
Solutions
Whether your Voice over IP requirements are large or small,
Foundry Networks has the right solution for your business.
Layer 2 and Layer 3—802.3af compliant powered Ethernet
switches are available in a variety of form factors including 24 and
48 port stackable switches as well as in chassis form factors for
maximum flexibility. Foundry is well known for building
solutions that enable performance in every aspect.Fully featured
quality of service functionality guarantees that the most
important traffic gets through in the LAN, MAN, and WAN.
Foundry has enabled the ability to recognize and prioritize
Voice traffic without sacrificing the performance or best in class
low latency.
Network managers do not want any complexity surrounding the
delivery of power in the network and to that end, Foundry has
engineered specific features that reduce complexity of powering
remote equipment.
t802.3af compliant powered ports
tPower support for legacy non-802.3af compliant devices
tConfigurable power on a per-port basis
t“Smart” ports that delivers the proper wattage even if
manually mis-configured
tRedundant power supplies even with a fully powered chassis
tFull 15.4 watts per port on a fully populated chassis
tThree RU high Power Shelf for up to 14 fully POE powered modules
tPower across modules in one or multiple chassis in a rack

IP Multicast
-DVMRP v3-07
-PIM-DM v1
-RFC 1112 IGMP
-RFC 1122 DVMRP Host Requirements
-RFC 1122 Host Extensions
-RFC 1256 ICMP Router Discovery Protocol
-RFC 2236 IGMP v2
-RFC 2283 MBGP
-RFC 2362 PIM-SM
-RFC 3618 MSDP
General Routing Protocols
-RFC 768 UDP
-RFC 783TFTP
-RFC 791 IP
-RFC 792 ICMP
-RFC 793TCP
-RFC 826 ARP
-RFC 854TELNET
-RFC 894 IP over Ethernet
-RFC 903 RARP
-RFC 906TFTP Bootstrap
-RFC 951 BootP
-RFC 1027 Proxy ARP
-RFC 1122 Host Requirements
-RFC 1256 IRDP
-RFC 1519 CIDR
-RFC 1541,1542 & 2131 BootP/DHCP Helper
-RFC 1542 BootP Extensions
-RFC 1591 DNS (client)
-RFC 1812 General Routing
-RFC 2338VRRP
Others
-RFC 1157 SNMPv1
-RFC 1191 Path MTU discovery
-RFC 1215 SNMP generic traps
-RFC 1354 IP Forwarding MIB
-RFC 1573 SNMP MIB II
-RFC 1757 RMON Groups 1,2,3,9
-RFC 1905,1906 SNMPv2c
-RFC 2030 SNTP
-RFC 2068 HTTP
-RFC 2138 RADIUS
-RFC 3176 sFlow
-RFC 3411 SNMPv3 framework
-RFC 3412 SNMPv3 processing
-RFC 3414 SNMPv3 USM
-RFC 3415 SNMPv3VACM
-TACACS+ v1.78
Network Management
-IronView Network Manager (INM)Web based graphical
user interface
-Integrated Standard based Command Line Interface (CLI)
-sFlow (RFC 3176)
-Telnet and SSHv1
-SNMP
-HTTP and HTTPS
-RMON HP OpenView for Sun Solaris, HP-UX, IBM’s
AIX,andWindows NT
Element Security Options
-AAA
-RADIUS
-Secure Shell (SSH v2.0)
-Secure Copy (SCP)
-TACACS/TACACS+
-Username/Password (Challenge and Response)
-FI-level Access Mode (Standard and EXEC Level)
-Protection for Denial of Service attacks,such asTCP SYN
or Smurf Attacks
Environmental
-OperatingTemperature:0 °C to 40 °C (32 °F to 104 °F)
-Relative Humidity: 5 to 90%, @ 40 °C (104 °F),
non-condensing
-Operating Altitude: 10,000 ft (3,000 m) maximum
-StorageTemperature:-25 ºC to 70 ºC (-9 ºF to 158 °F)
-Storage Altitude: 15,000 ft (4,500 m) maximum
-Storage Humidity:95% maximum relative humidity,
non-condensing
Safety Agency Approvals
-CAN/CSA C22.2 No. 60950-1-03/UL60950-1
First Edition, Safety of InformationTechnology Equipment
-EN 60825-1 Safety of Laser Products—Part 1:
Equipment of Classification,Requirments and User’s Guide
-EN 60825-2 Safety of Laser Products—Part 2:
Safety of Optical Fibre Communication Systems
-EN 60950-1/IEC 60950-1
Safety of InformationTechnology Equipment
Emissions
-Canada Interference Causing Equipment Regulations
-FCC Class A
-EN 55022/CISPR-22 Class A/VCCI Class A
Immunity
-EN 61000-3-2 Power Line Harmonics
-EN 61000-4-2 ESD
-EN 61000-4-3 Radiated Immunity
-EN 61000-4-4 EFT
-EN 61000-4-5 Surge
-EN 61000-4-6 Low Frequency Common Immunity
-EN 61000-4-11Voltage Dips and Sags
-Generic:EN 50082-1
-ESD:IEC 61000-4-2; 4 kV CD,8 kV AD
-Radiated:IEC61000-4-3; 3V/m
-EFT/Burst: IEC 61000-4-4;1.0 kV (power line),
0.5 kV (signal Line)
-Conducted:IEC 61000-4-6; 3V
Warranty
-1-year hardware
-90-day software
Mounting Options
-19" Universal EIA (Telco) Rack orTabletop
IEEE Compliance
-802.3,10BaseT
-802.3u 100BaseTX,100BaseFX
-802.3z 1000BaseSX
-802.3z 1000BaseLX
-802.3ab 1000BaseT
-802.3ae 10 Gigabit Ethernet
-802.3x Flow Control
-802.3ad Link Aggregation
-802.3af Power over Ethernet
-802.1d Bridging
-802.1p/qVLANTagging
-802.1w Rapid STP
-802.1x user authentication
-802.3 Ethernet Like MIB
-Repeater MIB
-Ethernet Interface MIB
-SNMPV1,V2c andV3
-SNMP MIB II
RFC Compliance
BGPv4
-RFC 1269,1657 BGP3 and BGP4 MIBs
-RFC 1745 OSPF interactions
-RFC 1771 BGPv4
-RFC 1965 BGP4 confederations
-RFC 1997 Communities &Attributes
-RFC 2385 MD5 Authentication of BGP Session
-RFC 2439 route flap dampening
-RFC 2796 route reflection
-RFC 2842 BGP4 capabilities
OSPF
-RFC 1583 and 2328 OSPF v2
-RFC 1587 OSPF NSSA
-RFC 1745 OSPF Interactions
-RFC 1765 OSPF Database Overflow
-RFC 1850 OSPFTraps
-RFC 1850 OSPF v2 MIB
-RFC 1997 CommunitiesAttributes
-RFC 2154 OSPF w/Digital Signatures
(Password,MD-5)
-RFC 2178 OSPF
-RFC 2328 OSPF v2
-RFC 2370 OSPF Opaque LSA Option
-RFC 2385TCP MD5
-RFC 2439 Route Flap Damping
-RFC 2842 Capabilities Advertisement
-RFC 2918 Route Refresh Capability
IS-IS
-RFC 1195 Routing inTCP/IP and
Dual Environments
-RFC 1377 PPP
-RFC 2763 Dynamic Host Name Exchange
-RFC 2966 Domain-wide Prefix Distribution
RIP
-RFC 1058 RIP v1
-RFC 1723 RIP v2
-RFC 1812 RIP Requirements
6
TechnicalSpecifications

7
FastIron System Power Specifications
Platform FastIron 400 FastIron 800 FastIron 800 FastIron 1500
Power Supply(s) 1122
-40 to -60VDCConsumption (Amps) 17A17A33A58A
100-120VAC Consumption (Amps) 8A 8A 15A 30A
200-240VAC Consumption (Amps) 4A 4A 7.5A 15A
AC frequency 47 – 63 Hz 47 – 63 Hz 47 – 63 Hz 47 – 63 Hz
Max BTUs (fully populated) 1,877 1,877 3,753 7,508
MaxWatts (fully populated) 550 550 1100 2200
FastIron System Physical Specifications
Platform FastIron 400 FastIron 800 FastIron 1500
Dimensions 9"h x 17.5"w x 15"d 23"h x 17.5"w x 15"d 29.75"h x 17.5"w x 15"d
(22.86 x 44.5 x 38.1 cm) (58.4 x 44.5 x 38.1 cm) (75.68 x 44.5 x 38.1 cm)
Weight (fully loaded) 47.7 lbs (21.5kg) 69.1 lbs (31.1 kg) 170 lbs (76.5 kg)
OrderingInformation
Part Number Description
FI400 4-slot FastIron 400 Chassis
FI800 8-slot FastIron 800 Chassis
FI1500 15-slot FastIron 1500 Chassis
RPS3 90-220VAC Power Supply for FastIron 400 & FastIron 800
RPS3DC 48VDC Power Supply for FastIron 400 & FastIron 800
RPS4 90-220VAC Power Supply for FastIron 1500 only
RPS4DC 48VDC Power Supply for FastIron 1500 only
RPS6 90-220VAC Power Supply for RPS-POE Shelf
J-F2404GMR4 24-port 10/100Base-TX (RJ-45) & 4-port 1000Base-X mini-GBIC or 1000Base-T (RJ-45) management module (double-wide module)
J-FxGMR4 8-port mini-GBIC based Gigabit management module
J-F2GMR4 2-port mini-GBIC based Gigabit management module
J-F48E-A 48-port 10/100BaseT RJ-45 interface module (double-wide module)
J-F48T-A 48-port 10/100BaseT RJ-21Telco interface module
J-F24FX 24-port 100Base-FX (MTRJ) for 50 or 62.5µm MMF interface module
J-F24FX-SR 24-port 100Base-FX (MTRJ) for 9 or 10µm SMF interface module (15km)
J-F24FX-IR 24-port 100Base-FX (MTRJ) for 9 or 10µm SMF interface module (40km)
J-FxG 8-port mini-GBIC based Gigabit interface module
J-F16Gx 16-port mini-GBIC based Gigabit interface module
J-F16GC 16-port 100/1000BaseT interface module
J-F24E-POE 24-port 10/100Base-T 802.3af POE compliant interface module
RPS-POE Shelf POE Power Supply Shelf, supports 14 POE cards with n+1 Power redundancy
E1MG-SX 1000Base-SX mini-GBIC optic,MMF, LC connector
E1MTG-SX 1000Base-SX mini-GBIC optic,MMF, MTRJ connector
E1MG-LX 1000Base-LX mini-GBIC optic,SMF, LC connector
E1MG-LHA 1000Base-LHA mini-GBIC optic,SMF, LC
E1MG-LHB 1000Base-LHB mini-GBIC optic,SMF,LC connector 150 km maximum reach
E1MG-TX 1000Base-TX mini-GBIC Copper,RJ-45 connector
E1MG-CWDM80-xxxx CWDM mini-GBIC optics,80 km SMF, LC connector where xxxx corresponds to the nm wavelengths of the optics, values are
1470,1490,1510, 1530, 1550, 1570, 1590 and 1610
10 GbE
F10Gx1 1-port 10 Gigabit Ethernet module with 850nm LAN Optics (up to 300 meters on MMF)
F10Gx2 2-port 10 Gigabit Ethernet Base module – requires optics:select 10G-XNPK-LR or 10G-XNPK-ER
10G-XNPK-LR 1310nm serial pluggable Xenpak optic only (SC) for up to 10km over SMF
10G-XNPK-ER 1550nm serial pluggable Xenpak optic only (SC) for up to 40km over SMF
10G-XNPK-SR 850nm serial pluggable Xenpak optic only (SC) for up to 300 m over MMF
10G-XNPK-LX4 1310nm parallel pluggable Xenpak optic for 300m over FDDI-grade MMF or 10km over SMF
10G-XNPK-CX4 Copper parallel pluggable Xenpak media for 15m over Infiniband cable
10G-XNPK-LW 1310nmWAN PHY pluggable Xenpak optic for OC-192 SONET connection of 10 km over SMF

DS-007/Rev3/11-04
© 2004 Foundry Networks,Inc.All Rights Reserved.Foundry Networks,FastIron,NetIron,FastIron,ServerIron,IronWare,
Jetscope, IronView and the“Iron”marks or trade marks are registered trademarks of Foundry Networks,Inc.in the United States
of America and other countries. sFlow is a registered trademark of InMon Corporation. Specifications are subject to change
without notice.
Foundry Networks, Inc.
Corporate Headquarters
2100 Gold Street
P. O. Box 649100
San Jose,CA 95164-9100
U.S. and CanadaToll-free:
1-888-TURBOLAN (887-2652)
Tel: +1 408.586.1700
Fax:+1 408.586.1900
info@foundrynet.com
www.foundrynetworks.com
Although Foundry has attempted to provide accurate information in these materials, Foundry assumes no legal responsibility for the accuracy or
completeness of the information.More specific information is available on request from Foundry.Please note that Foundry’s product information does
not constitute or contain any guarantee,warranty or legal binding representation,unless expressly identified as such in duly signed writing.
8
This manual suits for next models
2
Table of contents
Popular Switch manuals by other brands

Dell
Dell Brocade VDX 6940 Configuration guide

Brocade Communications Systems
Brocade Communications Systems ICX 6450 datasheet

ATEN
ATEN ALTUSEN KH2508 specification

SMC Networks
SMC Networks SMC6248M installation guide

Conceptronic
Conceptronic HUBBIES09B manual

D-Link
D-Link Web Smart DES-1210-52 Specifications