Fiberpowertech Compact Receiver User manual

Compact Receiver is an easy-to-use wire, cable and duct sonde locator. Compact
Receiver is compatible with all 10kHz and 33kHz transmitters and sondes, as
well as 512HZ sondes for metal ducts.
Compact Receiver can be used to trace and pinpoint duct sondes and
underground cables from several metres depth. Indoors Compact Receiver can
be used e.g. to locate oor heating cables and wires inside the walls.
Introduction
Fiberpowertech Plutovej 7 8722 Hedensted Denmark phone: +45 75 89 22 99 mail: mail@berpowertech.dk www.berpowertech.dk
FIBER OPTIC
SOLUTIONS
FIBER OPTIC
SOLUTIONS
COMPACT RECEIVER
PRODUCT INSTRUCTION

User interface function
Battery installation
Connecting probes
Sonde catcher
1. Speaker: Indicates recelved signal strength; the
higher pitch and volume, the stronger signal.
2. Power LED: Green LED displays power on.
LED blinks if battery is weak.
3. Arc of 12 red LEDS: In normal operation arc
displays received signal strength with 24 levels.
4. During start-up or mode changing LED arc has
alternative meanings, see Button functions.
To change the batteries, turn the user
interface cap (1) o and take the battery
holder (2) Place old cells with new ones.
Observe battery polarity: (-) poles must be
placed against the spring contacts. Insert the
battery holder back into CR tube according
to the arrow symbol (3). Turn the user
interface cap back on the tube (4).
Battery 3 x A/tuA (IEC LR03)
alkaline batteries
To attach a probe: Push the probe connector
(1) in to CR socket (2) until the locking clicks.
To remove a probe: Press the release button
(3) under the rubber to release the locking
and pull the probe out.
When using duct sondes always mount sonde catcher
including sponge on the ducts end.
Fiberpowertech Plutovej 7 8722 Hedensted Denmark phone: +45 75 89 22 99 mail: mail@berpowertech.dk www.berpowertech.dk

Button functions
Maintanence, storage, warranty
DANGER!! When using duct sondes always mount sonde catcher including sponge on the ducts end.
CR receiver and probes do not have any parts that require maintenance by the user, excluding
changing of batteries. When cleaning a soiled or wet device, clean and dry the device before
removing probes or opening battery compartment to avoid dirt or water getting into the
battery compartment or connectors. Do not use corrosive solvents for cleaning. If water gets
into the CR battery compartment, allow it to dry at room temperature. We recommend that
the units are stored in dry conditions at room temperature.
FPT is not liable for any nancial losses or damages , or for any damage incurred by people, the
enviroment, and telecommunication trac or similar as a result of the use of or the failure to
use the CR device or accessories. CR has one-year warranty for factory defects. The warranty
shall not cover batteries or faults resulting from normal wear and tear or misuse. Users are
advised to contact the manufacturer in case of faults or queries relating to the use of the
devices.
(+) long press: power on|o
(+) extended pressing during start-up: makes the LED arc show rmware version
(+) releasing press during start-up: makes the LED arc briey display batter status and the
active operating frequency with one of the three right most LEDs.
(+) and (-) short presses: gain setting up or down, 5 or 7 steps available depending on
connected probe. A beep sound indicates change of gain, no beep means that maximum or
minimum has been reached.
(-) long press: Initiate change of receiving frequency mode:
1) Keep (-) pressed until a beep is heard
2) Keep (+) pressed until another beep is heard
3) See the LED arc 512/10k/33k LEDS briey display the chosen frequency
4) Release both buttons
5) If necessary repeat 1 to 4 to get the right frequency. Connected probe allows choosing
only frequencies supported by the probe. The three rightmost LEDs briey display the active
operating frequency also when a probe is connected.
Fiberpowertech Plutovej 7 8722 Hedensted Denmark phone: +45 75 89 22 99 mail: mail@berpowertech.dk www.berpowertech.dk

Protection class
IEC 60529 IP44
Enviromental conditions
Usage -40....+60oC (dry or moist conditions)
Storage -40....+60oC (dry conditions)
Enclosure material & size
Stainless steel and aluminium, 180 x 40mm
Weight approx. 230g ( no probes )
Batteries
3pcs. 1.5V IEC LR03 (AAA)
Sound indicator
Internal speaker
LED indicators
Green LED,12 red LED’s
for power and signal
strength indication
Technical Specication
Fiberpowertech Plutovej 7 8722 Hedensted Denmark phone: +45 75 89 22 99 mail: mail@berpowertech.dk www.berpowertech.dk
Compact Receiver - sondes overview - additional setup
6,4 mm4,6 mm 7,5 mm 9,0mm 18,0mmDiameter
84 mm94 mm 114 mm 138mm 85 mmLength
2,3 m
9 h
M5F
8mm
2,3 m
9 h
M3,5F
6mm
5,1 m
6 h
M5/6F
9-12mm
5,7 m
10 h
M5/6F
14-20mm
10,0m
20 h
M5/6/10/12F/M
21-42mm
Free air range
Operatingtime 20oC
Threads
* Recommended air pressure for straight duct calibration - < 5 bar - use sonde catcher for impact absorption
Straight duct
calibration ID*
1
2
3
4
5
DANGER!! When using duct sondes always mount sonde catcher including sponge on the ducts end.
Microduct sondes are
small transmitter sondes
intended for calibrating
and locating ber optic
microducts and their
blockages.