FibroPool FH-020 Specification sheet

Swimming Pool Heat Pump
—Operation and Installation Manual—
MODEL
FH-020

CONTENTS
INTRODUCTION
Index...........…………………………………......................................……………………………......…………... 2
The unit ………………………………………………………………………………………………………….................. 2
S FETY INSTRUCTIONS …………………………………………………………………………………………... 4
Electrical Installation Warning ….………………………………………………………………………………………….… 4
Location Warning……………………………………………………………………………………………………………… 5
CONTENTS OF THE BOX …………………………………………………………………………………………….…… 6
OVERVIEW OF THE UNIT ……………………………………………………………………………………….……… 7
EXPLODED VIEW…………………………………………………………………………………………….…………………. 8
INST LL TION …………………………………………………………………………………………….…..….…….… 9,10
Installation AREA …………………………………………………………………………………………….…..….....…. 9
Optimize our installation .………………………………………………………………………….…………………… 9
Water connection …………………………………………………………………………………..…………….………….. 9
Electrical connection ……………………..……………………………………………………………………….….……… 9
Trial running …………………………………………………………………………………………….……..……………….. 10
OPER TING THE UNIT …………………………………………………………………………………………….……… 11
Features and functions …………………………………………………………………………………………….……….. 11
User interface ……………………………………..…………………………………………………………………………… 11
Buttons …………………………………………………………………………………………….……………………….… 12
S stem fault table…………………………………………………………………………………………………………… 13
P R METER CODES, ERROR CODES …….....……………………………….……………….……………. 13
Parameter list ….........………………………………………………………………………….……………………. 14
M INTEN NCE …………………………………………………………………….……………………………………….. 15
TROUBLESHOOTING …………………………………………………………….………………………………………… 16
ENVIRONMENT L INFORM TION ……………………………………….………………………………………… 17
WIRING DI GR M …………………………………………………………….…........……………………………. 18
W RR NTY INFORM TION…………………………………………….……………………………………………. 19
READ THIS MANUAL CAREFULLY BEFORE STARTING UP THE UNIT. DO NOT THROW IT AWAY.
KEEP IT IN YOUR FILES FOR FUTURE REFERENCE.
BEFORE OPERATING THE UNIT, MAKE SURE THE INSTALLATION HAS BEEN CARRIED OUT BY A LICENSED
AND COMPETENT PROFESSIONAL . IF YOU FEEL UNSURE ABOUT INSTALLATION OR OPERATION,
CONTACT YOUR DEALER FOR ADVICE AND INFORMATION.
2

INTRODUCTION
This manual includes all necessary information about the unit. Please read this manual carefully
before you use and maintain pump.
The unit
The swimming pool heat pump is one of the most economical s stems to heat swimming pools
efficientl . Using the free, renewable energ from the air, it delivers up to 6.2 times more energy in
heating than a traditional heating s stem such as a gas boiler or electric heater, saving 85% on energ
costs. The swimming pool heat pump provides comfortable swimming temperatures ear round in
milder climates and extended swimming seasons in the cooler/ drier climates
Ecological and economical heating
B making use of the renewable energ in the outside air, it consumes much less energ with low
carbon emissions. Utilizes environmentall and ozone-friendl technolog , R410A.
Titanium heat exchanger
Advanced titanium heat exchanger guarantees a long life span and protects against the damaging
effects of corrosion or rust. B using a titanium heat exchanger, the heat pump is compatible with
all t pes of water treatment such as chlorine, bromine and salt.
Multiple functions
- Cooling and heating functions
- Auto-operation, Auto-restart, Auto defrost
- Timer on/off: no attendance is required
- Wide ambient working condition: -5°C to 43°C (23°F to 109°F)
Reliable operation
To guarantee the stable operation and safet of the unit, multiple protection devices have been
built into the design, including insufficient water flow protection, high/low pressure protection,
overload protection and compressor protection.
Safe use
The unit runs without oil, gas or an other hazardous substance, removing the risk of intoxication,
smell, combustion, pollution from leakage.
Self-diagnosis
In case of a malfunction, the pump will make a self-diagnosis b displa ing an error code on the
control panel, no guesswork necessar .
3

S FETY INSTRUCTIONS
To prevent injur to the user, others, or propert damage, the following instructions must be carefull
followed. Ignoring these instructions ma result in injur or death.
Install the unit onl if it complies with local codes, b -laws and standards. Check the main voltage and
frequenc . This unit is onl suitable for grounded circuits, connection voltage 220 – 240 V ~ / 60Hz. It
cannot be converted to 120 volts.
The following safet precautions should alwa s be taken into account:
-Be sure to read the following WARNING before installing the unit.
-Be sure to observe the cautions specified here as the include important items related to safet .
-After reading these instructions, be sure to keep them in a hand place for future reference.
Installation must be done by a licensed and competent professional
Incorrect installation could cause injur or death due to fire, electric shock, the unit falling or leakage of
water. BE SURE ALL LOCAL CODES ARE FOLLOWED.
Use the specified electrical wires and attach wires firmly to the terminal board (connection in such a
way that the stress of the wires is not applied to the sections).
THIS UNIT REQUIRES 220-240 VOLTS, C, 60 Hz, 20 mp DU L BRE KER WITH APPROPRIATE SIZE WIRE.
The weather-proof wire provided with the unit is 8 feet long. Some municipalities DO NOT authorize
usage of weather-proof wires, and require conduit protection.
This unit runs on 220 - 240 volts only. It cannot be used with 120 volts electricity
Be sure to use the provided or specified parts for the installation work.
Be sure to use the 'EQUIPOTENTI L BONDING CONNECTION “ on the chassis of the heater. Please
connect this bond to a minimum of #8 copper wire; along with the rest of the metal parts around the
pool, in accordance with NEC 2005 -680.26 Electrical code.
The unit must always have a GROUNDED connection, as well as a bonding connection
Do not use an extension cord to connect the unit to an electrical power supply.
Do not move/repair the unit yourself.
Before proceeding with an maintenance, service or repair work, electrical lines must be
DISCONNECTED. Onl a licensed/competent technician should work on this unit.
Use only Genuine FIBROPOOL® P RTS for replacement. ll parts can be obtained from Fibropool,
www.fibropool.com
4

Do not install the unit in a place where there is a fire hazard:
G S LE KS. If there is a gas leak and gas accumulates in the area surrounding the unit, it could cause
an explosion.
UNDER THE ROOF E VES . Although the unit is weatherproof, a direct pour of water from the roof is
likel to penetrate the shell and cause a shortage. Please install the heater in an open area exposed to
weather, but not beneath the roof line
ON WET SURF CE. Wet areas will cause metal corrosion and shorten the life of our heater
LOWER TH N SURROUNDING RE S. Install our heat pump on an equipment pad or concrete blocks
to prevent accumulated water from entering the unit from bottom.
IN ENCLOSED RE S. The heat pump needs fresh air to operate. Do not install in equipment rooms or
enclosed areas. If this is a must, be sure to install an air fan to suppl fresh air to the room, at a rate of
NO LESS THAN 3,000 cfm.
Do not open the unit when the power is ‘ON’.
Alwa s shut ‘OFF’ the power b disconnecting the suppl breaker or service disconnect when cleaning
or servicing the unit. Electrical shock, Injur or death can occur, as the unit works on HIGH voltage
Do not continue to run the unit when there is something wrong or there is a strange smell.
The service disconnect must be pulled off or breaker turned off in case of an suspicious condition.
Do not put your fingers or other items into the fan.
The ventilator runs at high speeds, potentiall causing serious injur .
Do not block the drain holes on the bottom.
The unit will SWE T heavil during operation. This is commonl mistaken for a leakage, but is
actuall CONDENSATION, moisture in the air draining.
Provided elbow can snap to the bottom of the heater and ma be directed b attaching a hose.
5

CONTENTS OF THE PRODUCT BOX
Before starting the installation, please make sure that all parts are found inside the box.
The Unit Box
Item Image
*Swimming pool heat pump
**Operation and Installation
Manual
***Union set
****Drain adapter elbow
( inside the service panel)
6

OVERVIEW OF UNIT
Unit Dimensions Required Clearance
- Height 1'-10” 12”- top
B - Length 3'-0” 36” on service panel side, 12” on the far side
C - Width 1'-3” 12 “ on both sides
7

EXPLODED VIEW
1Cover 10 Chassis 19 Controller
2Fixed frame 11 Fan motor 20 Controller mounting board
3Front panel 12 Compressor 21 Four wa valve
4Wire controller 13 Evaporator 22 Titanium heat exchanger
5Copper tube 14 PCB 23 EEV
6Motor bracket 15 Support column 24 Low pressure switch
7Left side panel 16 Rear side panel 25 High pressure switch
8Guide air circle 17 Pressure gauge 26 Copper tube
9Fan blade 18 Cable fixing head 27 Maintenance panel
8

INST LL TION
Installation area
Install the unit on a flat, horizontal and stable surface. An HVAC equipment pad is ideal, although 4“ thick
concrete blocks will work as well.
To optimize installation
Allow a minimum of 12” of clearance on all 3 sides, but ensure 36” in front of the service panel
Water connection
The heat pump can be connected to the filtration circuit b one of two methods:
1. With a 3-valve
b pass, placed after the pump and filter. This allows the user to regulate water flow to the pump and
isolate the unit completel for maintenance.
2. Inline with the
s stem. This will somewhat reduce the flow rate of the filtration s stem on large circulation pumps.
NOTE
If our pool has a water treatment s stem (chlorinator, salt generator, brominator etc...) installed, the b pass
must be installed before the water treatment. A check valve after the heater, before the treatment s stem is
recommended but not required.
Electrical connection
Electrical suppl must be installed b a licensed electrician. This unit uses a double pole, 230-240 Vac, 60 Hz
circuit, with a 20-amp breaker. The unit will use a maximum of 9 amps of electricit during operation.
9

Trial running
After connecting water to the pool s stem perform a test run.
Ensure that:
Appliance is horizontal and on a firm base.
Plumbing is firml connected, using the approved t pe of pvc primer, glue or couplings.
Electrical wire is firml connected (all screws tightened correctl at terminals and intermediate
circuit breaker), insulated and GROUNDED correctl .
TURN ON YOUR POOL CIRCULATING PUMP “ON”
TURN ON THE BREAKER FOR THE HEATER
TURN ON YOUR HEATER WITH THE “ON/ OFF” SWITCH
OBSERVE THAT THE HEATER STARTS WITHIN 1 MINUTE BY KEEPING AN EYE ON THE PRESSURE
GAUGE.
ONCE THE HEATER TURNS ON, PRESSURE WILL CLIMB. LEAVE IT RUNNING FOR 5 MINUTES TO ASSURE THAT
ALL PARAMETERS ARE CORRECT
◦
ATTENTION: THE HEAT PUMP ONLY FUNCTIONS WHEN WATER FLOW IS PRESENT.
10

OPER TING THE UNIT
Operating the unit is done by the controller ONLY.
There will be NO NEED to open the service panel for operations
NEVER LET THE DIGITAL CONTROLLER GET WET. THIS MAY LEAD TO AN ELECTRICAL SHOCK OR FIRE.
NEVER PRESS THE BUTTONS OF THE DIGITAL CONTROLLER WITH A HARD, POINTED OBJECT. THIS
MAY RESULT IN DAMAGE.
NEVER SERVICE THE DIGITAL CONTROLLER. THEY ARE SOLID STATE CONTROLLERS WITH NO MOVING
PARTS INSIDE.
Features and functions
Basic controller functions
The basic controller functions are:
Unit ‘ON’/’OFF’.
24-hour, real-time clock.
Timer ‘ON’ and timer ‘OFF’.
Parameter adjustment
User interface
LED cooling and heating controller interface
11

Buttons
Unit ON/OFF button
USE THIS BUTTON TO TURN THE UNIT ON or OFF.
Unit is ON when clock, running mode and timing state are displa ed on screen.
Mode button
Press this button to select the running mode at an time. Each time this button is pressed, the
HEATER will c cle between one of four modes IF AVAILABLE. It will illuminate the Mode the heater is
in, such as “Heating” or “Cooling”
Timer ON button
Press this button when the unit is not in clock setting. Set desired hour and minute, then press
once more to exit timing boot setting. In the corresponding conditions, press“ ” to set the ▲▼
corresponding time value.
Timer OFF button.
Press this button when the unit is not in clock setting condition, the unit can be turned into timing
shutdown setting condition, press this button again to set hour and minute ,press it one more time
to exit timing shutdown setting. In the corresponding conditions, press“ ”Set the corresponding▲▼
time value.In timing shutdown setting condition,press “”can cancel timing shutdown function.
Timer Button
Press “” directl entering into Timer Settings, the“88.88”flashing, then press“”to set Hour with“ ”▲▼
,and press “” again to set Minute with “ ”,then press again to save and complete settings.In▲▼
Timer Setting condition, “”button and “”button invalid.
“ ”or“ ”Button:▲ ▼
Used for the temperature setting, parameter setting, parameter checking, and adjustment of the
timer.
In clock Setting,the are used for adjusting hour and minute
In turn ON/OFF timing setting,the are used for adjusting hour and minute;
In normal condition, press “”button for 5 seconds to enter parameter checking interface, at this
time press “”again enter into parameter setting;In other condition,at the same time
Press“ ”and“ ”5 seconds enter into ke board lock,press it again at the same time for 5 seconds▲ ▼
exit the ke board lock.
Press BOTH for 10 seconds, wire control parameter are reset.
12

SELF DI GNOSTIC SYSTEM CODES ND ERRORS:
Protection/
Malfunction
remote
controller LED indicator
Standb Dark
Normal operation Bright
Lower tank water temp.
sensor failure PP 1 ● (1 flash 1 dark)☆
Upper tank water temp.
sensor failure PP 2 ● (2 flashes 1 dark)☆☆
Evaporator coil temp.
sensor failure PP 3 ● (3 flashes 1 dark)☆☆☆
Return air temp. sensor
failure PP 4 ●(4 flashes 1 dark)☆☆☆☆
Ambient temp. sensor
failure PP 5 ● (5 flashes 1 dark)☆☆☆☆☆
Cooling coil heat failure PP 8 ●( 11 flashes 1 dark)☆☆☆☆☆☆
In and out of the water
temperature difference is
too large to protect
PP 6 Bright
Refridgeration cold
protection PP 7 Bright
Winter level 1 antifreeze
protection PP 7 Dark
Winter level 2 antifreeze
protection PP 7 Dark
High pressure protection EE 1 ●(6 flashes 1 dark)☆☆☆☆☆☆
Low pressure protection EE 2 ● (7 flashes 1 dark)☆☆☆☆☆☆☆
Flow failures ON
EE 3
● (8flashes 1 dark)☆☆☆☆☆☆☆☆
Phase sequence protection EE 4 ● (9flashes 1 dark)☆☆☆☆☆☆☆☆☆
In and out of the water
temperature difference is
too large fault
EE 5 ● (10flashes 1 dark)☆☆☆☆☆☆☆☆☆☆
Defrost Defrosting
indication ……(a long flashes)☆☆☆☆☆☆☆☆
Communication failure EE 8 The fault is available for remote controller onl
IF THERE IS INSUFFICIENT WATER FLOW OR A FLOW SENSOR MALFUNCTION, THERE WILL BE AN
ERROR DISPLAYED: “EE03”
13

P R METER CHECK ND DUSTMENT
Parameter list
Some parameters can be checked and adjusted b the controller. Below is the parameter list.
Parameter Explanation Range Default
value Remarks
0Cooling water c cle temperature
value 15-35℃(59~95℉)82℉(24℃)Adjustable
1heating water c cle temperature
value 15-40℃(59~104℉)82℉(24℃)Adjustable
2 The interval for defrosting 30~90Min 40Min Adjustable
3Defrosting entr coil
temperature -30-0℃(-22~36℉)-7℃(19℉)Adjustable
4 Defrosting-off coil temp. 2-30℃(36~86℉)20℃(55℉)Adjustable
5 Defrosting max. lasting time 1~12Min 8Min Adjustable
6Unit mode selection (heating
onl /heating and cooling) 0~11(heating and
cooling)Adjustable
7electronic expansion valve
adjustment 0~1 1(auto)Adjustable
8 Heating target over-heat degree -15~15℃(5~59℉)3℃(37℉)Adjustable
9 cooling target over-heat degree -15~15℃(5~59℉)-2℃(28℉)Adjustable
A Electronic expansion valve step 18~94 70*5 Adjustable
b Inlet water temp (-9~99℃)-4~210℉Actual
Reading
C Outlet water temp (-9~99℃)-4~210℉Actual
Reading
d Heating coil temp (-9~99℃)-4~210℉Actual
Reading
E Return gas temp. (-9~99℃)-4~210℉Actual
Reading
F Ambient air temp. (-9~99℃)-4~210℉Actual
Reading
G Cooling coil temp (-9~99℃)-4~210℉Actual
Reading
HElectronic expansion valve
practical count N*5 Actual
reading
LInlet water temp calibration
parameter
(-9.9-~9.9)14~50℉0℃Adjustable
14

M INTEN NCE
To protect the chassis, avoid placing objects on the device. External heat pump parts can be wiped with
a damp cloth and household cleaner. (Note: Never use cleaning agents containing sand, soda, acid or
chloride as these can damage the surface)
To prevent malfunctions due to sediment in the titanium heat exchanger, ensure that the heat
exchanger cannot be contaminated. In the event that operating malfunctions occur due to
contamination, the s stem should be cleaned as described below. (Warning: the fins on the tube heat
exchanger have sharp edges-use caution to avoid injur )
Cleaning the pipe system in the heat exchanger
Contamination in the pipes and heat exchanger can reduce the performance and efficienc of the pump.
Pressurized drinking water should be used b a technician to remove an of these substances.
Cleaning the air system
The finned heat exchanger, ventilator and condensation outflow should be cleaned of debris (leaves,
twigs, etc...) before each season. These t pes of contaminants can be manuall removed using
compressed air or b flushing with clean water. It ma be necessar to remove the device cover and air
inlet grid first.
The external fins can be cleaned with a spra on air conditioner condenser cleaner.
Note: Before opening the device, ensure that all circuits are isolated from the power suppl .
To prevent the evaporator and condensation tra from being damaged, do not use hard or sharp objects
for cleaning. Under extreme weather conditions, ice ma form on the air intake and exhaust air outlet
grids. If this happens, all ice from these grids must be removed to ensure that the minimum air flow rate
is maintained.
Winter Shutdown/Lay-up
If the outdoor temperature is expected to drop below the pump's operating limit (-5°C or 23°F) after the
swimming season has ended, the water circuit of the heat pump should be completel drained to avoid
damage.
For this, simpl disconnect the unions, and lean the heater 45' degrees to the side of the connections.
This will remove most/ all standing water from the tank. If ou are not confident that all water has been
removed, simpl insert a wet-dr vacuum hose into the bottom water port and vacuum out the
remaining water.
Attention: Warrant does not cover damages to the heat exchanger tanks.
15

TROUBLESHOOTING
This section provides useful information for diagnosing and correcting certain issues which ma occur.
Before starting the troubleshooting process, carr out a thorough visual inspection of the unit and look
for obvious defects such as loose connections or defective wiring.
Before contacting our local dealer, read this chapter carefull , it will save ou time and mone .
WHEN CARRYING OUT AN INSPECTION OF THE SWITCH BOX OF THE UNIT, ALWAYS ENSURE THE
MAIN SWITCH OF THE UNIT IS SWITCHED ‘OFF’.
The guidelines below ma help to solve our problem. If ou cannot solve the problem, consult our
installer or local dealer.
1.877.FIBROPOOL
1.877 342-7676
support@fibropool.com
The heat pump will not run.
Please check whether:
There is suppl of proper voltage (tripped fuse, power failure). Please be sure 230-240 volts is read
on the multimeter. OFTEN 1 SIDE OF THE BREAKER TRIPS AND OTHER SIDE SUPPLIES 120 V, WHICH
FEEDS BACK AND YOU CAN GET A 120 V READING ON BOTH TERMINALS. But this is a false reading.
Be sure to read 230-240 volts between the suppl lines
The operating switch on the wired controller is switched ON, and whether the correct set point
temperature has been set.
The set temperature level cannot be reached.
Please check whether:
The permissible operating conditions for the heat pump have been adhered to (air temperatures
too high or too low).
The air inlet or outlet area is blocked, restricted or dirt .
There are closed valves or stopcocks in the water pipes.
The scheduled timer does work but the programmed actions are executed at the wrong time (e.g. 1
hour too late or too earl ).
Please check whether:
The clock and the da of the week are set correctl , adjust if necessar .
If ou cannot correct the fault ourself, please contact our service technician.
Work on the heat pump ma onl be carried out b an authorized and qualified service technician.
16

ENVIRONMENT L INFORM TION
This equipment contains fluorinated greenhouse gases covered b the K oto Protocol. It should onl be
serviced or dismantled b professional trained personnel.
This equipment contains R410A refrigerant in the amount as stated in the specification. Do not vent
R410A into the atmosphere: R410A, is a fluorinated greenhouse gas with a Global Warming Potential
(GWP) = 1975.
DISPOS L REQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, of oil and of other parts must be done in
accordance with local and national legislation.
Your product is marked with this s mbol. This means that electrical and electronic products
shall not be mixed with unsorted household waste.
Do not tr to dismantle the s stem ourself: the dismantling of the s stem, treatment of the refrigerant,
of oil and other parts must be done b a qualified installer in accordance with relevant local and
national legislation.
Units must be treated at a specialized treatment facilit for reuse, rec cling and recover . B ensuring
that this product is disposed of correctl , ou will help to prevent potential negative environmental
consequences. Please contact the installer or local authorit for more information.
Note: *******
When repair and maintenance need to open the unit, PLE SE OPEN THE SERVICE P NEL FIRST. Your
heater has concealed screws, that can only be reached from the service panel.
17

WIRING DI GR M
Please refer to the wiring diagram on the electric box.
MODEL:FH 020
18

19
Table of contents
Other FibroPool Heat Pump manuals
Popular Heat Pump manuals by other brands

Danfoss
Danfoss DHP-A Service instructions

Aquacal
Aquacal 100 Owner's manual and installation guide

REMKO
REMKO WKF Series Electrical Wiring Manual

AERMEC
AERMEC ANKI 020 installation manual

Enviro-tex
Enviro-tex EVI Series Installation and user manual

Heat Controller
Heat Controller VMH C Series Service manual