●Pl as install th unit in complianc with local CODES, r gulations and standards;
●Please use a solid base, such as 2 pieces of 16” x 16” x 4” concrete blocks or an equipment
base of 16” x 32 inches minimum size
●Confirm power voltage and frequency; 208-240 volts, 60 Hz 20 Amps
●2 Hot Leads, 1 Ground No Neutral, Non GFCI Within 50 feet of the breaker box, use 12 AWG
gauge wire ( 12-2+ Ground), 50-150 feet distance from breaker box to the heater, pls use 10
AWG wire ( 10-2+Ground)
●The heater must be BONDED to a ground rod, using #8 AWG bare copper wire
●An external timer or a service disconnect must be installed in accordance with local electric
codes
●1 1/2” schedule 40 pvc must be used to connect plumbing
●WATER AND ELECTRICITY DONT MIX PLEASE USE ALL PRECAUTIONS AND DO NOT
SHORT CUT ANY SAFETY PROCEDURES
●Do not install this heater in an enclosed room Without adequate air supply, the heater will not
function well If the unit was installed in a closed area or limited space, please consider the size
of room and ventilation to prevent suffocation caused by refrigerant leakage
●Be sure to Install a BONDING wire to a ground rod, using #8 AWG Bare Copper Wire
●Fibropool FH 270 is weatherproof and designed to be outdoors But is is not designed to be
below eaves of the roof, where water pours onto it Please use common sense in choosing a
location
●Do NOT install this heater where there may be flammable gas
●This heater is made of mostly metal alloys, and may have sharp edges, please use gloves while
handling it
●Heater weighs about 150 lbs It is a 2 person handling size and weight
V-2105 Fibropool Co LLC, Ms USA

Syst m Sp cifications
1. Sp cifications
Model FH 270
82'F Air 82'F Water 82% RH
Max Heating capacity (Btu/h) 70000
Max Power input (Btu/h) 12132
COP 5 77
60'F Air 75'F Water 65%RH
Heating capacity (Btu/h) 33440
Power input (Btu/h) 8360
COP 4 01
Power supply 208-230V/60Hz
Max power input (Btu/h) 13850
Max current (A) 17 7
Setting temperature range (Heating) 60°F~99°F
Setting temperature range (Cooling) 50°F~82°F
Running (Air) temperature range 23°F~109 4°F
Refrigerant type/quantity (Oz) R410A/ 48 Ozs
Air side heat exchanger Hydrophilic fin exchanger
Water side heat exchanger Titanium tube heat exchanger
Water flow (gpm) 33 GPM
Net dimension LxWxH (inch) 37 x 14 x 32
Packing dimension LxWxH (inch) 41 x 17 x 33
Net weight (lbs) 146 lbs
Packing weight (lbs)196
Noise level dB(A) 47
Water proof level IPX4
Water pipe connection PVC Sch 40 1-1/2”
Inlet/Outlet
The technical specification of our heat pumps is provided for information purpose only We reserve
the right to make change without notice in advance
Performance varies greatly depending on the weather conditions
1 Ratings based un US Dept Of Energy guidelines, 82-82-82 / 80-80-80/ 78-78-78
2 US Dept Of Energy recommends pool water temperatures 78, 80, or 82 Degrees
1 Noise at 4 feet ) comply with Directives EN ISO 3741 and EN ISO 354
V-2105 Fibropool Co LLC, Ms USA

1. Unit Dim nsions
Mod l: Fh 270
Unit:in
V-2105 Fibropool Co LLC, Ms USA

1. Explod d Vi w
1 Front plate 9 Middle plate 17 Chassis component
2 Fan 10 Water flow switch 18 Silencer cotton
3 Stand pillar 11 Titanium heat exchanger 19 Motor
4 Protection net 1 12 Right plate 20 Motor support
5 Protection net 2 13 Controller box
6 Evaporator 14 Handle
7 Electrical box 15 Cooper pipe component
8 Top cover 16 Compressor
V-2105 Fibropool Co LLC, Ms USA

Installation Instructions
WARNING: Installation must be carried out by a qualified person
This section is provided for information purpose only and may vary depending on your location/
regulations/ availabl spac for installation
1. Pr -R quir m nts
Needed equipment for installation of heat pump:
Suitable power supply cable for unit’s power Usually 12-2+Ground protected by flexible conduit
A by-pass kit ( 3 way valve) , PVC pipe and fittings, Pipe cleaner/ primer, Medium Bodied Glue
Electrical tools, and a ,multimeter
A service disconnect or timer within 6 feet of the heater
An equipment pad, 16” x 32” x 4” thick or 2 pieces of concrete blocks, 16 x 16 x 4 inches each
2. Location
Please comply with the following rules about heat pump location choosing
1 Make sure the heater is not directly below the roof drains, such as gutter drain, or eaves
2 Be sure that the heater does not submerge in water in heavy rain
3 Be sure to install the drain adapters into the heaters, and attach the hose to direct the
condensation water Heater will produce gallons of water from condensation, every day
4 Confirm the unit is under well-ventilated conditions; fan discharge grill vent is not blocked ( Fan
blows outwards )
5 Keep at least 12 inches of clearance on the two short sides and the long radiator side
6 Keep at least 3 feet of clearance on the fan side of the heater
7 Keep the unit as far as possible away from children's reach and within 25 feet of the pool
V-2105 Fibropool Co LLC, Ms USA

DRAIN ADAPTERS
Please install the darin adapters beneath the heater prior to installation You can add 5/8 hose to
the adapters to direct the condensation water
PLUMBING
·A typical installation on a pool with a small pump, such as ½, ¾ hp pump with 1 1/2” pvc or
flexible pipes, just requires pipes to go in from the bottom and exit thru top
·For stronger systems, with 1 0 Hp and larger pumps, and 2 inch plumbing systems, a bypass
system should be installed
·If The heat pump is connected to a filtration circuit with a by-pass valve; The bypass valve
should be partially opened (throttled), while all the other valves should be completely
opened We suggest to open bypass 50% then adjust until the lowest volume of water going
through the heater, but no error messages ( EE-3, PL, EE1) are present This will give
enough water to the heater, and not restrict your flow
·The old system BYPASS path usually consists of 3 valves The New FIBROPOOL BY PASS
VALVE is just 1 valve That makes it possible to adjust water flow which passes through heat
pump
V-2105 Fibropool Co LLC, Ms USA

1. Installation of a Single Heater
2. Parallel Installation for 2 Units
Throttled by pas valve, 50% open
V-2105 Fibropool Co LLC, Ms USA

PIPE C NNECTI NS
1. FH 270 Features 1 1/2” SAE machine threads They are NOT the typical pipe threads You
can use the included unionized fittings with o rings, WITHOUT thread tape, or you can use
the conical hose adapters, WITH thread tape
2. All fittings and pipes used must be 1 1/2” Sch 40 ( Schedule 40) PVC pipe
3. Tighten all fittings by hand only If using the threaded hose adapters, give a ¼ turn with
pliers after hand tight Excessive tightening will crack fittings
4. A minimum of 6 inches of straight pipe must be used before any elbows/ fittings etc
5. Please support the pipes in the air, as gravity will eventually bend and break the fittings
6. If using flexible hoses, be sure to tighten the clamps well
7. Be sure to check your fittings and glue them properly, using pipe cleaner and a good grade
Medium bodied glue
8. Heaters have heat exchanger coils, therefore they increase back pressure
9. If your pool pump is larger than 1 horsepower, you should use a bypass valve This will help
water flow of your system to continueas original plumbing You simply need to get a 3 way
valve, and a Tee Refer to diagrams for the bypass set up
10. If you have 2 inch plumbing, use our 2 inch bypass valve and a 2 inch TEE, then use
reducers to 1 1/2” pipe to connect to the heater This way you will not compromise the water
flow
11. Be sure that WATER IN pipe is connected to the bottom, and WATER OUT pipe is on Top
Reversal will result in flow error codes
V-2105 Fibropool Co LLC, Ms USA

ELECTRICAL C NNECTI NS
Pow r Supply Wir s Siz
Mod l Pow r Supply Wir s
Power Supply Cable Diameter Specification
Fh 270 208-240V/60Hz 3×4 0mm (3×0 157inch) AWG 12
WARNING: Pow r supply of h at pump must b disconn ct d b for any op ration.
➢St p 1: D tach front pan l by a scr wdriv r.
➢St p 2: Ins rt cabl into h at pump l ctrical conn ctor port. This port is d sign d for
outdoor SO cords (wat rproof fl xibl cords.) If using a fl xibl conduit, simply r mov
th adapt r, and install conduit adapt r.
➢St p 3: Conn ct pow r supply cabl to t rminal block according to th diagram b low.
➢FH 270 do s NOT hav a NEUTRAL conn ction Th r for , Do NOT us a GFCI br ak r.
➢FH 270 r quir s quipot ntial bonding. Pl as conn ct an #8 AWG bar copp r wir to a
ground rod. This is r quir d for saf ty and corrosion pr v ntion of th h at rs m tal
chassis.
V-2105 Fibropool Co LLC, Ms USA

Running T st
Insp ction B for Running T st
1. Ch ck l ctrical conn cors, t rminal scr ws. B sur all ar tight
2. Ch ck voltag at th pow r supply, 208-240 volts must b obs rv d.
3. Ch ck Bonding wir 's tightn ss and attachm nt to th ground rod.
4. Ch ck plumbing conn ctions, mak sur all glu d, tight and In from BOTTOM, OUT from TOP
Turn on the pump
Wait about 1 minut , for all th air to purg from th syst m
Turn on the heater
Push th ON OFF button on th h at r, Making sur th SUNSHINE sign is on top.
ALLOW ABOUT 5 MINUTES, FOR THE FAN TO START BLOWING COLD AIR, CONDENSATE
WATER TO START DRIPPING.
This is th indication of th h at r working.
If all is w ll, l av your h at r running. Your h at r will only b on whil your pump is ON
In and out t mp ratur s mayb v ry clos or v n th sam , but this d p nds on many
factors including a strong pump pushing th wat r too fast to r gist r. R al indication of h ating
is cold air and cond nsation.
V-2105 Fibropool Co LLC, Ms USA

1. Control Function D scription
➢“ON/OFF”key:Turn ON/OFF the heat pump
➢“MODE”key:Press MODE key to select :
AUTO mode – Triangle Sign
COOLING mode – Snowflake sign
HEATING mode – Sunshine Sign
➢CLOCK key:Time setting ( NOT AVAILABLE ON MOST MODELS)
Press this key, then SET Use the up and down arrows to set the current time Use M button to
swap between hour/ minute settings There is NO TIMER This is only to set the time You DON'T
have to set the time, it does not effect the operation of the heater at all
➢UP AND DOWN “”and“”key:
Press “”and“”key to set the target temperature in the main interface
➢“SET” key:
Press this key to enter the fault query state, and then press this key to query other fault displays in
the current state
Press and hold SET key to enter parameter state, then press “MODE” key to enter the setting
You can set the parameters by pressing “”“” key, press “SET” key to set other
parameters exit the parameter setting state automatically if there is no operation within 5 seconds
FOR A HOMEOWNER, ALL YOU NEED TO SET IS THE HEATING AND COOLING
TEMPERATURES. YOU DON’T NEED TO GO INTO ADJUSTING PROGRAMS. SIMPLY, PRESS
MODE TO GO TO HEATING, USE THE ARROWS UP AND DOWN . THATS ALL
THE FACTORY SETTINGS ON THE SYSTEM ARE DELICATE. AND THERE IS NO FACTORY
RESET OPTION. THEREFORE, WE DO NOT RECOMMEND A HOMEOWNER TO ATTEMPT TO
CHANGE OPERATIONAL SETTINGS.
V-2105 Fibropool Co LLC, Ms USA

SYSTEM PARAMETERS
***************************************WE DO NOT RECOMMEND CHANGING FACTORY SETTINGS.
THERE IS NO FACTORY SETTINGS- RESET BUTTON. THE ONLY OPTION IS TO
REPROGRAM THESE FUNCTIONS INDIVIDUALLY OR REPLACE THE MOTHERBOARD. IN
MOST CASES, THE ERROR/ PROBLEM WILL GO AWAY BY RESTARTING THE SYSTEM.
JUST TURN OFF THE BREAKER FOR 45 SEONDS AND TURN IT BACK ON. THIS WILL
ERASE THE SENSORS' MEMORIES.*************************************************************
V-2105 Fibropool Co LLC, Ms USA
No Param t r Nam Rang D fault R mark
0Memory Function during power off 1 Adjustable
1Timer Cycle- Daily 0 (no) /1 (yes) 1 Adjustable
2
Adjustable
3Adjustable
4Defrost duration 30-90 Min 40Min Adjustable
5Defrosting trigger coil temperature Adjustable
6Defrosting – off coil temp
Adjustable
7Max Defrost Duration 1-12Min 8Min Adjustable
8Compressor exhaust gas protection 90-120 (194-248 )℃ ℉ Adjustable
9Max desired temperature Unvalid
10 1 N/A
11 3-20MIN 15 N/A
12 Second anti- freezing mode 1 fixed
13 Heat- Cool Mode Selection 1 Adjustable
14 High pressure switch 1
15 Low pressure switch 2
16 Water flow switch 1
17 Emergency switch 2
18 Electric heater over heat protection -
19 Inlet water temp -9~99℃
20 Outlet water temp -9~99℃
21 Coil temp -9~99℃
0 (no) /1 (yes)
X(Temp- Difference between compressor
Start – desired setting( accuracy) 2-10°C (35 6-50°F)
3 ℃(37 4 )℉
Y(Temp Difference between compressor
Stop and Desired temperature ( Accuracy) 0-3°C (32-37 4°F) 0 ℃(32)℉
-30°C~0°C ( "-" and "°C" not
display)
-1 (only display ℃
“1”)
2-30°C (35 6-86°F)
15℃ (59 )℉
110 (230 )℃ ℉
25~40 (℃77-104 )℉40 (104℃℉)
Water pump running mode – DISABLED
2021 0(Special)\1(Normal)
Pump Firemans Switch timer – DISABLED
2021
0(HP)/1(Electric heater)
0(cooling only)\1(cooling and
heating)\2(heating only)
0: Alarm when closed
1: Alarm when open
2: Invalid
0: Alarm when closed
1: Alarm when open
2: Invalid
0: Open when abnormal
1: Close when abnormal
2: Invalid
1: Enable
2: Disable
1: Alarm when open
2: Invalid
Measured
Measured
Measured

BELOW ARE COMMON QUESTIONS ASKED
To resolve a problem, we nee to i entify whether it is a mechanical problem, or performance.
POOL NOT HEATING:
•In and out diff r nc too small: Either the air humidity is too low, or the pool pump is
pushing too hard Difference 0-4 degrees accepted Higher the humidity ( 80% or higher),
higher the difference
•initial h ating tak s tim Allow a few days for the water to heat up, while leaving the pool
pump and heater on 24-7 And cover the pool with any type of cover
•H at r is not working: there are 3 basic indicators of the heaters operation 1- heater
blowing cold air 2- compressor pressure goes up by about 0 5 MPA 3- heater dripping water
from the condensation lines after 10-15 minutes If any of these conditions are observed, the
heater is working The problem is performance, not functionality
•H at r is not l aking wat r from th bottom: Heat pumps will create quite a bit
condensation, which will drain from the bottom of the heater
•Th air is too dry: Pool heat pumps are optimized for 80% humidity If the humidity is much
less, best thing is to install a set of micron misters A set can be purchased for about 20-30
dollars from hardware stores Which screws into the garden hose and sprays mist Place
the heads near the coils, this way the incoming air will draw moisture into the heater coils
and heat exchange rate will increase, thus resuting in better output
•Pool pump's tim r s tting is too short: Pool heaters need pool pumps circulation If the
pump doesnt run long enough, neither will the heater Please adjust the timer settings on
your pump or remove the timer for heating
•Th fan is not coming on, th pr ssur is not going up on th pr ssur gaug : When
the thermostat calls for heat, the fan will come on within 4 minutes, and within 45 seconds,
the compressor will kick in If this doesnt happen, and the pool water temperature is much
lower than the desired temperature, there is a mechanical issue of an error message on the
screen Be sure that there is no error messages on the screen This may require a phone
call to us at Fibropool Co 1 228 313 7874
•Pool is too big for th h at r, for your climat zon : There is not much can be done,
except adding a second heater into the system
•Air is too cold: Heat pumps absorb heat from the air If the air too cold- below 60F, the
performance will be very little Your only option is to wait for warmer weather
HEATER IS GIVING WATER FLOW ERROR (PL)
•Pool pump is OFF
•Pool pump is really weak
•Pool filter is dirty
•Plumbing is connected backwards, cold water is connected to top
•By pass valve is set incorrectly, not allowing water to flow thru the heater.
HEATER IS VIBRATING/ SHAKING HEAVILY
•Loose or broken Fan blade
NO DISPLAY
•igital display is damaged. This happens mostly if the protective cover is broken or missing, making the
controller NOT weather proof.
•The incoming power is not 220 volts. Reading between L1 and L2 should be between 208-240 volts.
•Motherboard's fuse is blown.
V-2105 Fibropool Co LLC, Ms USA

ERROR CODES
V-2105 Fibropool Co LLC, Ms USA
ERROR CODE DESCRIPTION POSSIBLE CAUSES ACTION
PL
Water flow sw itch failure
PC
PC
P1 Coil temp sensor failure Softw are Crash/ Sensor failure
P2 Softw are Crash/ Sensor f ailure
P3 Inlet w ater temp sensor failure
P4 Outlet w ater temp sensor f ailure
P6
P7 Ambient temp sensor f ailure Softw are Crash/ Sensor failure
P8
P9
Low Freon pressure
E2
E3
E4 High Freon pressure
E8
Communication failure
Insuf f icient Water Flow /
Plumbing Connected backw ards/
Flow sw itch Failure /
Motherboard Failure
*Make Sure the w ater is
circulating back to Pool
*Check the plumbing lines, make
sure the w ater IN from the f ilter
is connected to the bottom port
Level 1 anti-f reeze protection in
Winter
The Air temperatures too low
and unit is on standby
*Wait for outside air
temperatures to increase
Level 2 anti-f reeze protection in
Winter
The Air temperatures too low
and unit is on standby
*Wait for outside air
temperatures to increase
+Turn the heater of f at the
breaker for 45 seconds and
restart *Replace the Sensor
Compressor exhaust gas temp
sensor f ailure
*Turn the heater of f at the breaker
for 45 seconds and restart
*Replace the Sensor
Softw are Crash/ Sensor failure/
Open circuit
*Turn the heater off at the
breaker for 45 seconds and
restart *Check the w ire and
connection * Replace the
sensor * Replace the
Motherboard
Softw are Crash/ Sensor failure/
Open circuit
*Turn the heater off at the
breaker f or 45 seconds and
restart * Check the w ire and
connection *Replace the sensor
*Replace the Motherboard
Excessive Temperature Difference
for IN and OUT sensors
Low w ater f low /Motherboard
failure
*Check w ater circulation *Chec k
w ater temperature * Replace
motherboard
*Turn the heater off at the
breaker for 45 seconds and
restart *Replace the Sensor
Excessively LOW outlet w ater
temp in cooling mode
Low w ater f low rate/ Water inlet
w ater temp too low /
Motherboard failure
*Turn the heater off at the
breaker f or 45 seconds and
restart *Check the w ater flow
through the heat r *Adjust the
set temp to a higher level
*Replace motherboard
Low ref rigerant /
Capillary block / Pressure sw itch
connections / The pressure
sw itch failure /
Motherboard Failure
*Add Ref rigerant *Replace the
capillary
*Repair the sw itch w ires
*Replace the pressure sw itch
*Replace the Motherboard
Excessive Temperature Difference
for IN and OUT sensors
Low w ater f low /
inlet w ater temp is too low /
Motherboard failure
*Check w ater circulation
* Check w ater temperature
*Replace motherboard
Excessively high compressor
tempertures
*Low w ater f low rate
*Low ref rigerant
* Water temp is set too high
*Pressure sw itch Wiring Failure
*The pressure sw itch failure
*Motherboard failure
*Check pool's w ater circulation
* If using a bypass valve,
increase the f low to the heater
* Drain and recharge the ref ri
*Reduce desired temp setting
* Check the w iring of the sw itch
* Replace the pressure sw itc h
* Replace the Motherboard
*Low w ater f low rate
*Overcharged refrigerant
* Water temp is set too high
*Pressure sw itch Wiring Failure
*The
pressure sw itch f ailure
*Motherboard Failure
*Check pool's w ater circulati *
*If using a bypass valve,
increase the f low to the heater
*Drain and recharge the
refrigerant
*Reduce desired temp setting
* Check the w iring of the sw itch
* Replace the pressure sw itc h
* Replace the Motherboard
*Digital controller Failure
*Communication line is
disconnected, damaged or
unplugged f rom the motherboard
*Motherboard Failure
*Replace the Digital Controller
*Repair/ reinstall/ plug the w ire
*Replace the Motherboard

MAINTENANCE
•You should leave the heater on all the time, during the season Just adjust the temperature
and leave it on Electronic circuits should stay dry and warm with electricity
• Clean your pool's filtration system regularly to avoid the damage of the unit because of a
dirty or clogged filter
• Winterize properly by making sure there’s no water left in the heaters tank Or take it
indoors in the winter
• After the unit is conditioned in winter season, it is preferred to cover the unit with the
special winter heat pump cover
• Please keep the coils clean, by using “Foaming air conditioner coil cleaner”, available at
hardware stores
•Wint rization: If the unit is not running during winter months, please disconnect
power supply and pipes, and let out drain water from unit by tilting the heater on the pipes
side by 45 degrees, or using a shop vac
•Wint rization: if you want to move the unit indoors, just disconnect everything and
take it into your garage
V-2105 Fibropool Co LLC, Ms USA

V-2105 Fibropool Co LLC, Ms USA

V-2105 Fibropool Co LLC, Ms USA
Table of contents
Other FibroPool Heat Pump manuals
Popular Heat Pump manuals by other brands

Panasonic
Panasonic WH-SDF03E3E5 Design handbook

Aspira
Aspira ASPIRCOMFORT PRO X 460 H Installation, use and maintenance manual

Bosch
Bosch IDS 2.0 Service manual

Carrier
Carrier Aquazone 50PCH PCV 007 Installation, Start-Up and Service Instructions

Gree
Gree LSQWRF130VM/NhA-M Installation, start-up and maintenance manual

Whirlpool
Whirlpool W2H3 installation instructions