Filsa IR-D User manual

Page
Index
Rotary blade indicador
for solids
IR
Operating
Instructions
Talleres Filsa, S.A.U. www.filsa.es• • • • •E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 46 01 Fax +34 93 570 24 71 [email protected] 01
04/14 MI-IR-EN-01© by FILSA
Depending on the model
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02
Operating instructions
1. Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03
1.1 Intended use
1.2 Function
1.3 Technical data
1.4 Materials
1.5 Dimensions
2. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05
2.1 Preparing for use
2.2 Mechanical connection
2.3 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06
3. Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06
3.1 Commissioning
3.2 Normal operation
3.3 Inexpert handling
4. Maintenance, servicing and spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06
4.1 Maintenance
4.2 Servicing
4.3 Spare parts
5. Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06
6. Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 06

Read these Safety Instructions before using the switch for the first time and follow the Operating instructions.
Safety instructions
1. The installation, initial operation and maintenance should only be carried out by a qualified expert with electrical know-how.
2. Comply with the local and statutory rules and/or the VDE0100.
3. Before electrical connection, check the specifications on the data plate and the technical data of this manual.
4. A fuse must be connected in series to the supply voltage, according to the Standard and Normative documents.
5. Protect the signal contacts of the limit switch against voltage peaks when inductive or capacitive loads are connected.
6. The device may be put into operation only if the protection made of Porexpan and placed inside the housing has been removed. This is only a
protection during the transport of the device.
7. The device may be put into operation only if the electrical connection is correct. To secure the type of protection, the sealing cap and the gasket
must be placed correctly and the screw nut of the cable gland has to be fixed and fastened to the cable entry.
8. The earth connection of the device has to be installed in such a way that mechanical damage will be excluded.
9. Protect the controller from vibration and shakes. The vibration can provoke premature damage to the controller and may become useless.
10. The blade must not be hit by the filling stream. To avoid this, deflect the filling stream or install a deflection screen or a protection roof. It is also
recommended to install a protection roof when the controllers are used as empty-indicator or medium-indicator in silos where vaults could be formed
or where high loads above it could exist.
11. Avoid the installation of standard devices in ambient with vapour or with several changes of temperature. There are specific models for these
applications with different sealings rings and bearings that can extend the lifetime of the device.
12. Ask for rotary levels with the special sealing ring made of Stainless Steel-PTFE-Viton in applicactions with aggressive products or with micronized
bulk solids.
13. The connections of the single components as like as blade, shaft, extension, anti-buckling protection, etc. are permissible only with the attached
pins.
14. Switch off the power supply, before disconnecting the device.
IR
02 Talleres Filsa, S.A.U. www.filsa.es• • • • •E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 46 01 Fax +34 93 570 24 71 [email protected]
04/14 MI-IR-EN-02© by FILSA

130
143x175
130 160
Ø 110
130
143x175
Ø 110
200 160
IR-D IR-DR
125 or 180
143x175
50
150
100
Ø 200
IR-125 or 180
125 or 180
143x175
Ø 200
50
150180
IR-125 or 180 UF
length under
request,
max. 1.000 mm
Ø 200
150
143x175
50
125 or 180
IR-125 or 180 UF
pendulum shaft extension
with IR-125 or 180 UFM
extension with protecting
tube
shaft
143x175
Ø 200
125 or 180
50
170
length under
request,
max. 2.000 mm
04/14 MI-IR-EN-03© by FILSA
Operating instructions
1. Specification
1.1 Intended use
The rotary blade level indicator IR observes the filling level as a
limit switch. It can be used as indicator for dusty and powdery,
granulated and grainy bulk goods and are appropriated due to the
range of models and blades to control the level of bulk solids like
dust, flour, grain, sand, plastic, etc.
1.2 Function
1.3 Technical data
Manufacturer Talleres Filsa, S.A.U.
Address Bernat Metge, 33
08100 Mollet del Vallès
(Barcelona)
Name Rotary blade indicator
Type IR-... ref: 210...
Measuring blade speed 1 rpm
Switching voltage Standard 230 V AC (50 ... 60 Hz)
(Under request 115 V AC, 48 V AC, 24 V AC, 24 V DC due to a
converter)
3 VA in AC; 3 W in DC
3 3
Density of the product 0.01 t/m ... 2 t/m
Maximum pressure -0.5 bar ... +1 bar
(Under request up to +5 bar with sealing ring of Stainless Steel-
PTFE-Viton)
Cable entry 1 of M20x1.5 and 1 of M16x1.5
Under request up to
Weight 2.5 kg ... 5 kg depending on the
model
with a bulk density between
3
0.01 to 2 t/m . Although the characteristics of the product, humidity,
conductivity, grain size, etc. change, any adjustment is needed
These devices are used to control the level in silos, containers,
bunkers and they can be installed horizontally or vertically. For
vertical mountings there are rope shafts up to 10 m that could be
made depending on the product to control.
The rotating measuring blade, projecting into the silo or container,
is driven by a gearmotor. If the bulk material reaches the
measuring blade, the rotation will be hindered and it will be
stopped. The return torque turns the pivoted motor from its end
position and actuates the signal switch. A second switch turns the
motor off.
If the filling level of the bulk material sinks, the blade becomes
freely again and a spring will turn the motor back into its original
end position. Thereby the motor will be turned on again and the
signal switch will be switched back.
Power consumption
Maximum voltage of contact 250 V AC
Capacity of the contact 15 A / 250 V AC
(for resistive loads)
For inductive or capacitive loads reduce at 50%
Bulk goods temperature -20 °C ... +80 °C
( +150 ºC)
Ambient temperature -20 °C ... +70 °C
Contact function 1 NO + 1 NC
Protection IP65 according DIN EN60529
IR
Talleres Filsa, S.A.U. www.filsa.es• • • • •E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 46 01 Fax +34 93 570 24 71 [email protected] 03
IR-001 IR-002
IR-003 IR-004
IR-005 IR-006
1.4 Materials
Housing Aluminium, RAL 7001 coated
Flange connection and nut Aluminium, Zincated Steel or S.S.
(Under request) depending on the model
Measuring blade S.S. 1.4301, shaft S.S. 1.4305
(Under request special models of S.S. 1.4401, Plastic or Gummy)
Sealing ring NBR
(Under request Stainless Steel-PTFE-Viton)
Rope shaft Stainless Steel
Rod shaft Stainless Steel
Protection tube shaft Zincated Steel
(Under request Stainless Steel)
1.5 Dimensiones
Approximate measures are given in mm.

IR
04 Talleres Filsa, S.A.U. www.filsa.es• • • • •E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 46 01 Fax +34 93 570 24 71 [email protected]
04/14 © by FILSA MI-IR-EN-04
standard 2.000 mm,
other lenght under request,
max 10.000 mm
50
143x175
Ø 200
125 or 180
150
143x175
Ø 110
160
standard 800 mm,
other lenght under request,
max. 2.000 mm
272
68
IR-69 IR-C:
IR-C 69: model with blade 69 and
flange A-25-110
standard according drawing
Ø 50
25
Ø 50
25
50
Ø50
Ø 50
50
25
Ø 180
Ø 200
Flange connection
Threaded flange in all models G 1 " 1/4 female.
“H” Flanges in Zincated Steel
“A” Flanges in Aluminium
“I” Flanges in Stainless Steel
H-25-200
H-50-200
I-25-200
I-50-200
25
Ø 69 Set screw M6
15
55
Ø 69
30 15
Set screw M6
150
150
Ø 18
Ø 50
25
Ø 50
50
25
Ø 50
Ø 69
7
25
Set screw M6
8
50
Ø 69
7
Set screw M6
8
25
Ø 90
Ø 110
Ø 9
AC-25-150
A-25-110
AC-50-150
I-50-110
A-50-110
I-25-110
IR-007 IR-008
IR-009
IR-010
IR-011
IR-012
IR-015
IR-016
IR-017
IR-018
IR-013
IR-014
50
170
Ø 50
Ø 8
2.5
2.52
2
2
2

04/14 MI-IR-EN-05© by FILSA
IR
Talleres Filsa, S.A.U. www.filsa.es• • • • •E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 46 01 Fax +34 93 570 24 71 [email protected] 05
130
130
200
200
68
60
60
10
50
125 or 180
60
220
30
60
30
30
30
2. Installation
2.1 Preparing for use
-
- Verify if you got all the parts, the controller, blade with pin and
shaft extension if it was requested.
Read the Safety instructions and the Operating instructions before
using the controller.
2.2 Mechanical connection
There are models that can be mounted horizontally or vertically into
the silo.
The standard form is mounting the device with a flange, drilling
holes on the silo to allow the mounting of the controller using
screws, rods, fasteners or nuts. If the flange was not requested, the
thread is G 1 " 1/4 and can be fixed using 1 or 2 nuts or introducing
it into a threaded socket with a maximum of 25 mm length. If it is
larger, the bulk goods have the possibility to deposit in the thread
socket. This could provoke that the device becomes useless.
IR-019
IR-020
IR-021
IR-022
IR-024
IR-025
125 or 180
10
50
IR-023
7070
60
100
Measuring blades
Diagonal blade IR-DR
and models with shaft
Diagonal blade IR-D
Blade X
IR-125 or IR-180
IR-69 blade
Hinged blade
Y 30x200
Hinged blade
T 30x200
Blade T IR-125
or IR-180

Protection roof
2.3 Electrical connection
Connection diagram AC
Connection diagram DC
Cable gland
- Fasten the cable gland after making the electrical connection.
- Fix and fasten the screw nut of the cable gland to make sure of
the water-tightness.
3. Use
3.1 Commissioning
- Put the controller into operation only if the installation and the
electrical connection have been done correctly.
-
The blade must not be hit by the filling stream. To avoid this,
deflect the filling stream or install a deflection screen or a
protection roof. It is also recommended to install a protection roof
when the controllers are used as empty-indicator or medium-
indicator in silos where vaults could be formed or where high loads
above it could exist.
The device may be put into operation only if the protection made
of Porexpan and placed inside the housing has been removed.
This is only a protection during the transport of the device.
3.2 Normal operation
- Use the device in its intended application only.
- Comply with the specifications
- If the controller is damaged, disconnect it immediately.
- It is forbidden to make changes to the device. This violates the
Normative.
3.3 Inexpert handling
- Ignoring the Safety instructions and the Operating instructions.
- Not intended use.
- Making changes or handling the controller.
- Violation against applicable Law and Standards.
- Using of non original parts.
4. Maintenance, servicing and spare parts
4.1 Maintenance
- If used correctly, no specific maintenance is required.
4.2 Servicing
- Check and review the state of the housing, the blade, shaft
extension if it was required and the correct commutation of the
electrical contact, as well.
4.3 Spare parts
- Use only original parts.
- The spare parts of the controller can be consulted in the document
“R-IR-01”.
5. Storage
- Store the controller in a dry and dust-free environment.
- Dismount the shaft together with the blade. Ensure that the shaft
of the level indicator with jib extension will not be buckled or
bended.
6. Disposal
-
- The controller can be recycled.
- The disposal applies to the valid environmental Guidelines
according to the location of the carrier and the local
manufacturing conditions.
on the data plate and the technical
data of this manual.
Switch off the power supply, before disconnecting the device.
IR
[
- Ground
1 - Supply voltage
2 - Supply voltage
NC - Normally closed
NO - Normally open
C - Common
- Ground
(-) - Negative: 0 V DC
(+) - Positive: 24 V DC
NC - Normally closed
NO - Normally open
C - Common
06 Talleres Filsa, S.A.U. www.filsa.es• • • • •E-08100 Mollet del Vallès (Barcelona) Tel. +34 93 570 46 01 Fax +34 93 570 24 71 [email protected]
04/14 © by FILSA MI-IR-EN-06
220
160
IR-026
IR-028
IR-027
[
FILSA constantly strives to improve its products and reserves the right to modify designs, materials and data without prior notice.
Keep this manual for further questions!
This manual suits for next models
7
Table of contents
Other Filsa Touch Panel manuals