DF-50475  Page 1 of 2
S911
7271-1209:126
BSA
1202-88-SA 0Q1A0.AY
CS308
is listed in the installation manual for each control panel. Easy
to install and maintain, this detector is designed for direct sur-
face mounting (using one of the B400 Series bases listed be-
low. Easy-to-wire screw terminals allow fast and simple field
wiring of IN, OUT, and remote annunciator connections.
Consult FireLite control panel specifications for the maximum
allowable loop resistance for the particular control panel to be
used.
To prevent wiring mistakes, observe polarities and make cer-
tain that each conductor is identifiable. A copy of Installation
and Maintenance Instructions is packaged with each detector.
For further information, refer to NFPA 72 Standard on Auto-
matic Fire Detectors.
A MOUNTING BASE SELECTION GUIDE is included on page
2 of this document.
JUNCTION BOX SELECTION GUIDE: Box depth is contin-
gent on base and wire size. Refer to National Electrical Code
or local applicable codes for appropriate recommendations.
Bases B401 and B401B can utilize a single-gang, 3-1/2" (88.9
mm) octagonal, 4" (101.6 mm) octagonal, or 4" square junc-
tion box. Bases B402B and B406B can utilize a single-gang,
3-1/2" octagonal, 4" octagonal, 4" square, 50 mm, 60 mm, or
75 mm junction box. Base B404B can utilize a 4" octagonal
or 4" square junction box.
GENERAL
The System Sensor 400 Series plug-in ionization smoke de-
tectors respond quickly to both fast flaming and slow smolder-
ing fires as required by UL 268. Unipolar dual chamber sen-
sor has the sensitivity needed to quickly detect smoke, and
the stability needed to avoid false alarms.
FEATURES
 Unique dual unipolar sensor:
 Provides exceptional stability.
 Factory preset at 1.9% nominal sensitivity.
 Stable operation up to 1,200 feet per minute (6 meters
per second) air velocities.
 Removable cover for field cleaning.
 Two visible LEDs blink in standby.
 Sealed against dirt, insects, and back pressure.
 Three-year limited warranty.
 Field metering of detector sensitivity.
 Built-in test switch.
 Low standby current.
 Built-in tamper-resistant feature.
 Designed for direct surface or electrical box mounting.
 360° field viewing angle of the visual alarm LEDs.
 Insect-resistant screening (0.020"/0.508 mm openings).
 Easy plug-in of the head to base.
 SEMS screws for easy wiring.
 Optional recess mounting.
 Field-adjustable sensitivity.
APPLICATIONS
Use to contribute to life safety, fire protection, and property
conservation. Superior to photoelectric detectors in detecting
fast-flaming fires. Superior to bipolar detectors in avoiding
false alarms.
CONSTRUCTION & OPERATION
All 400 Series plug-in ionization smoke detectors contain a
unique dual-source, dual unipolar chamber detection design
which will sense the presence of smoke particles produced by
fast combustion as well as slow smoldering fires. Additional
key features include a blinking LED standby status indicator,
an easily visible alarm indication, and provision for convenient
field test and metering.
The back of the detector is sealed to block back-pressure air
flow. The chamber is protected by a fine mesh (0.020"/0.508
mm) screen to minimize problems with dust, dirt, and insects.
If cleaning is required, it is easy to remove the cover (with a
special tool) and obtain access to the screen and chamber to
perform a thorough cleaning.
INSTALLATION
Model 1451 detectors are intended for use with FireLite UL-
listed control panels. Maximum number of detectors per zone
1451
California
State Fire
Marshal
June 19, 1998
Section: Conventional Initiating Devices
F-555
ISO-9001
Engineering and Manufacturing
Quality System Certified to
International Standard ISO-9001 Made in the U.S.A.
This document is not intended to be used for installation purposes. We try to keep our
product information up-to-date and accurate. We cannot cover all specific applications or
anticipate all requirements. All specifications are subject to change without notice. For
more information, contact FireLite. Phone: (203) 484-7161 FAX: (203) 484-7118
12 Clintonville Road, Northford, Connecticut 06472
1451
2-Wire and 4-Wire
Ionization Smoke Detector
Page 2 of 2  DF-50475
ss
ss
sB404B Wiring Diagram
MOUNTING BASE SELECTION GUIDE
*Functionality contingent on panel compatibility. **Must be limited by control panel.
RELAY CONTACT RATINGS: Resistive or Inductive (60% power factor load). Form-A: 2.0 A at
30 VAC/DC. Form-C: 0.6 A at 110 VDC, 2.0 A at 30 VDC, 1.0 A at 125 VAC, 2.0 A at 30 VAC.
GENERAL SPECIFICATIONS
Operating voltage: mounting base dependent (see chart
below).
Standby current: 120 micro amps.
Sensitivity: 1.9% nominal.
Weight: 0.6 pounds (272 grams).
Size: 3.2" (81.28 mm) high; 4.0" (101.6 mm) diameter with
unflanged bases, or 6.2" (157.48 mm) diameter with flanged
bases.
Construction: Flame-retardant white Noryl® plastic.
Temperature: 32°F to 120°F (0°C to 49°C).
Humidity range: 10 to 93% R.H. (non-condensing).
Maximum air velocity: 1,200 feet per minute (6 meters
per second).
PRODUCT LINE INFORMATION
Model Description
1451 Ionization Detector. Must be mounted to one of
the B400 Series Bases listed below.
RA400Z Remote Annunciator for 2- or 4-wire applica-
tions. Use with any System Sensor 400 Series
plug-in detector. Fits standard U.S. single-gang
electrical box.
MOD400R Field Test module for all of the System Sensor
400 Series Smoke Detectors.
ss
ss
sB401B/B401 Wiring Diagram
ss
ss
sB402B Wiring Diagram
Location of
holes to access
and release
locking prongs.
Locking
prongs.
Cover and
screen are
removable
for cleaning.
ss
ss
sB406B Wiring Diagram
esaB
ledoM
rebmuN
noisreV pooL
epyT
tnerruC
timiL
rotsiseR
mralA
tcatnoC
epyT
lanimoN
egatloV
ybdnatS
egatloV
tnerruC
warD
mralAno
&104B
B104B
/CLU/LU
45-NE *eriw-2oN CDV42/21 53ot5.8
CDV
001ot01
**Am
B204B CLU&LUeriw-4seYC-&A-mroFCDV42 23ot71
CDV
93ot41
Am
B404B CLU&LUeriw-4seY A/C-&A-mroF
yrosivrepuS CAV021CAV021 CAAm57
mumixam
B604B /CLU/LU
45-NE *eriw-2oNC-mroFCDV42 23ot51
CDV
001ot21
**Am

Other Fire-Lite Smoke Alarm manuals

Fire-Lite Keltron 95M3158 TTM-RPS Quick start guide

Fire-Lite

Fire-Lite Keltron 95M3158 TTM-RPS Quick start guide

Fire-Lite B310LP User manual

Fire-Lite

Fire-Lite B310LP User manual

Fire-Lite AFM-16ATX User manual

Fire-Lite

Fire-Lite AFM-16ATX User manual

Fire-Lite CP355 User manual

Fire-Lite

Fire-Lite CP355 User manual

Fire-Lite FACP User manual

Fire-Lite

Fire-Lite FACP User manual

Fire-Lite CFP-2410B User manual

Fire-Lite

Fire-Lite CFP-2410B User manual

Fire-Lite MS-4012 User manual

Fire-Lite

Fire-Lite MS-4012 User manual

Fire-Lite MS-9600 Owner's manual

Fire-Lite

Fire-Lite MS-9600 Owner's manual

Fire-Lite D350RP Instruction Manual

Fire-Lite

Fire-Lite D350RP Instruction Manual

Popular Smoke Alarm manuals by other brands

Carrier KIDDE P4010ACS-WF user guide

Carrier

Carrier KIDDE P4010ACS-WF user guide

FIBARO Smoke Sensor short service guide

FIBARO

FIBARO Smoke Sensor short service guide

Devolo Home Control Smoke Detector First steps

Devolo

Devolo Home Control Smoke Detector First steps

Linear DXS-80 manual

Linear

Linear DXS-80 manual

Ferguson FS2SD manual

Ferguson

Ferguson FS2SD manual

First Alert 9120BA user manual

First Alert

First Alert 9120BA user manual

DSC AMS-220 Installation and operation instruction

DSC

DSC AMS-220 Installation and operation instruction

ELRO FS1801 M Series instruction manual

ELRO

ELRO FS1801 M Series instruction manual

pyrexx PX-1C operating manual

pyrexx

pyrexx PX-1C operating manual

B.E.G. LUXOMAT SD1 operating instructions

B.E.G.

B.E.G. LUXOMAT SD1 operating instructions

PSA Products LIF10YPEW user guide

PSA Products

PSA Products LIF10YPEW user guide

Redbusbar SmokeSight SS10MAMA instruction manual

Redbusbar

Redbusbar SmokeSight SS10MAMA instruction manual

Vision ZS 6101 IN Installation & operation manual

Vision

Vision ZS 6101 IN Installation & operation manual

EL EL-4703 installation instructions

EL

EL EL-4703 installation instructions

Notifier AFP-400 Product installation guide

Notifier

Notifier AFP-400 Product installation guide

First Alert SA720 user manual

First Alert

First Alert SA720 user manual

Flamingo FA22RF user manual

Flamingo

Flamingo FA22RF user manual

System Sensor 2400AT Installation and maintenance instructions

System Sensor

System Sensor 2400AT Installation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.