Flextherm FLP12 User manual

9/14/07 1/4 400-610-000-E
The FLP12 programmable thermostat, specially designed for floor
heating installations, is equipped with two ultra-precise sensors
which allow temperature control by separately monitoring both floor
and ambient settings, thus providing greater comfort.
The control module has four DIP switches to select the following
options:
Time and Temperature
Display (1)
•°F/12h
• °C/24h (default)
Early Start (2)
• E.S. On
• E.S. Off (default)
This function determines the optimal system start time to obtain the
desired temperature by the set time. When this function is enabled, the
system can be activated a few hours before the program’s start time.
Temperature Control (3)
This model offers the following three types of temperature control:
Permanent Backlight (4)
• P.B. On (The display remains lit all the time.)
• P.B. Off (default. The display is lit for 12 seconds when the
adjustment ring or any button is pressed.)
Align the bracket tabs on the
control module with the holes
located on top of the previ-
ously installed power base
and secure the module to the
base.
NOTE: Keep the thermostat's air vents clean and free from
obstructions.
First Power On
When power is applied for the first time, the
screen displays 0:00 MO (Monday) as well as
the ambient/floor temperature.
If a problem occurs, one of the following mes-
sages will be displayed:
LO: the temperature is below 0°C (32°F) The
heating indicator is displayed and the system is activated.
HI: the temperature is above 70°C (158°F).
Er: the floor sensor is not connected properly or defective (temp.
control F) or the ambient sensor is defective (temp.
control AF).
To verify if the thermostat detects the floor sensor, select the
temperature control F (see DIP Switch Configuration). If the screen
displays Er, the floor sensor is not connected properly or defective.
If the screen displays the temperature, the sensor works.
DIP SWITCH CONFIGURATION
Temp.
control Switch
position Notes
Ambientwith
floor limits DOWN (AF) Requires a floor sensor
Floor
(default) UP (F) Requires a floor sensor
Ambient DOWN (AF) Use only when floor sensor is not installed.
Not recommended for floor heating
INSTALLATION
FLP12 - Control Module
User Guide
Current program number when
Automatic mode is activated
Room or floor
temperature.
Arrow indicates
a setpoint
Indicatestheamount
of power sent to the
floor heating system
Vacation
mode
Current time
and day
Economy setpoint
Manual
mode
Temperature
adjustment
ring
Day
setting
To program
and view the
schedule
Comfort,
Economy and
Vacation
setpoints
ON/OFF—To turn On/Off the
thermostat and GFCI reset
Time
setting
To clear a
program
To select a mode
or to exit
programming
mode
Comfort setpoint
Floor
minimum
and
maximum
temperature
(AF only)
GFCI test
button and
warning light
400-610-000-E (Flextherm FLP12 prog CAN) ENG.fm Page 1 Friday, September 14, 2007 4:13 PM

9/14/07 2/4 400-610-000-E
Setting the Time and Day
nPress D, Hor Mto access the menu.
oPress Hand Mto set the time.
pPress Dto select the day.
qPress MODE/RET to exit.
NOTE: If you remove the module from its base for more than
6 hours, the time and day must be reprogrammed.
The GFCI monitors the electrical flow for any loss of current;
if there is a loss, the thermostat will cut off power to the
heating system. The GFCI must be tested upon installation,
and once a month thereafter to ensure it is operating
properly.
nPress TEST:
• Successful: the TEST warning
light is ON, GFI is displayed and
power to the floor heating sys-
tem is cut off.
• Unsuccessful: the TEST warning
light is OFF. Cut power to the
floor heating system from the
main power panel and call cus-
tomer service.
oWhen successful, reset the
thermostat (OFF/ON) to reset the GFCI circuit.
WARNING: If the test warning light comes ON during normal
operation, cut power to heating system from the main power
panel and have an electrician verify the installation.
The display is lit for 12 seconds when any button or adjustment ring
is pressed.
Comfort and Economy Setpoints
These setpoints are associated with the
schedule’s programs and are
preprogrammed as follows:
Comfort: temp. control AF: 21°C (70°F)
temp. control F: 28°C (82°F)
Economy: temp. control AF: 16.5°C(62°F)
temp. control F: 20°C(68°F)
To modify a setpoint value:
nSet the temperature using the adjustment ring.
oPress and hold the setpoint button ( or or ) until the icon
is displayed on the screen. Screen automatically returns to nor-
mal display after 5 seconds.
Vacation Setpoint
This preprogrammed setpoint is used when the Vacation mode is
activated. To modify this value, repeat above steps.
Default: 10°C (50°F) for all control types
Floor minimum and maximum limits (AF only)
The floor temperature limits prevent damage to the floor and ensure
personal safety. The thermostat generally turns heating On or Off to
control the ambient temperature. However if the floor temperature
goes outside the desired limits, the thermostat will unconditionally
turn heating On or Off to maintain the floor temperature within its
limits.
Default: min 5°C (40°F) and max 28°C (82°F)
nTurn OFF the thermostat.
oPress and hold CLR and turn ON the
thermostat. Release CLR only when the
minimum setpoint is displayed.
pSelect the minimum setpoint limit using the
adjustment ring.
qPress CLR to display the maximum value.
rSelect the maximum setpoint limit using the adjustment ring.
sPress MODE/RET to exit.
NOTE: For the AF temperature control (ambient with floor
limits), the setpoint will always be maintained within the
minimum and maximum floor limits.
Automatic
Executes the schedule’s programs.
Press MODE/RET until the desired program
number is displayed (1 to 4).
To temporarily bypass the current program, set a
new temperature using the adjustment ring or
press one of the predefined setpoint buttons ( or ). The program
icon will flash to indicate the bypass. The new setpoint will be main-
tained until the beginning of the next program.
Manual
Maintains a constant temperature.
nPress MODE/RET until is displayed.
oSet the temperature using the adjustment
ring or press one of the predefined setpoint
buttons ( or or ).
Vacation
Maintains the Vacation setpoint during a
prolonged absence.
There are two ways to activate this mode:
nFrom the thermostat: press
oRemotely (using a telephone):
see Econo Input Signal section (requires an optional control).
GROUND FAULT CIRCUIT INTERRUPTION
(GFCI) TEST
BACKLIT DISPLAY
SETPOINTS
OPERATING MODE SELECTION
400-610-000-E (Flextherm FLP12 prog CAN) ENG.fm Page 2 Friday, September 14, 2007 4:13 PM

9/14/07 3/4 400-610-000-E
The schedule is executed when the Automatic mode is activated. It
controls your system by automatically switching from the Comfort
setpoint to the Economy setpoint at the preset times.
The preprogrammed schedule contains four (4) daily programs:
For savings
You can obtain a 2% energy reduction for each degree (°C) that the
temperature is lowered during an eight-hour period.
For example, if you program your thermostat to lower the tempera-
ture by 5°C (10°F) when you are at work and by another 5°C (10°F)
during your sleep, you would reduce your energy consumption by
20%
(5°C (10°F) x 2% x 2 eight-hour periods). Since the temperature is
lowered when your home is unoccupied and when the occupants
are sleeping, you save money without reducing comfort.
You can set up to four daily programs and each program can have
a different time for a total of 28 programs.
Below is a sample schedule:
NOTE: It is sometimes easier to program the same schedule
for the entire week and then modify the exception days.
nPress PGM to access the programming mode.
oPress Dto select the day to be programmed or hold for
3 seconds to select all days.
pUse PGM to select the program number.
qUse Hand Mto set the program’s start time or use CLR to
erase the time (--:-- the program is inactive).
rRepeat steps 2 to 4 for the remaining programs.
sPress MODE/RET to exit.
NOTE: After 60 seconds of inactivity the thermostat will
automatically exit programming mode.
The FLP12 thermostat is equipped with an Econo input (dry
contact) which allows connection of a telephone controller (optional
CT240/CT241) or any other remote control system. Refer to the
power base installation instructions for Econo input wiring.
When a signal is received through this input, the FLP12 thermostat
automatically switches from normal operating mode to the Vacation
mode. In this mode, the suitcase icon flashes and all buttons are
locked. The thermostat returns to the normal operating mode when
the signal is removed.
PREPROGRAMMED SCHEDULE
Programs MO TU WE TH FR SA SU
1Comfort6:006:006:006:006:006:006:00
2Economy 8:00 8:00 8:00 8:00 8:00 --:-- --:--
3Comfort 18:00 18:00 18:00 18:00 18:00 --:-- --:--
4Economy 22:00 22:00 22:00 22:00 22:00 22:00 22:00
SCHEDULE MODIFICATION
Programs MO TU WE TH FR SA SU
1Comfort 6:00 7:00 6:30 6:15 7:00 9:00 8:00
2Economy 8:30 9:30 7:15 8:00 8:30 12:00 --:--
3Comfort 16:00 17:00 15:30 18:00 16:00 18:00 --:--
4Economy 23:00 22:00 22:30 23:00 21:30 23:00 23:00
ECONO INPUT SIGNAL
400-610-000-E (Flextherm FLP12 prog CAN) ENG.fm Page 3 Friday, September 14, 2007 4:13 PM

9/14/07 4/4 400-610-000-E
The FLP12 thermostat determines the amount of power needed to
maintain the setpoint temperature.
Model: FLP12
Accuracy: ± 0.5°C (0.9°F)
Storage: -20°C to 50°C (-4°F to 120°F)
Memory backup: In the event of a power failure, an internal circuit
will save the programming. Only the time will have to be reset if the
power failure exceeds 6 hours.
The thermostat will return to the same operating mode in effect
before the power failure.
FLEXTHERM LIMITED WARRANTY
Flextherm Canada Inc. (hereinafter “FLEXTHERM”) warrants to the
purchaser that the FLEXTHERM PROGRAMMABLE THERMOSTAT
(hereinafter the “Product”) and once installed in conformity with the
instructions of FLEXTHERM, shall be free of defects, in either materials of
workmanship as described in this document.
COVERAGE PERIOD: This Limited Warranty becomes effective on the
date of the original purchase of the Product as supplied by FLEXTHERM
and shall remain effective for a period of one (1) year (twelve (12)
consecutive months) from such date. This Limited Warranty is valid for
products purchased and installed in Canada only.
CONDITIONS: This Limited Warranty is only applicable to new and unused
Products purchased from FLEXTHERM, or its authorized re-sellers,
provided the Installation Requirements contained herein are met. Claims
made for coverage under this Limited Warranty must be addressed in
writing, within seventy-two (72) hours from an event giving rise to a claim, or
the appearance of a defect, to: Flextherm Canada Inc. 1-800-353-9843. Any
parts replaced under the terms of this Limited Warranty become the
property of FLEXTHERM. Persons making claims for coverage must
present FLEXTHERM with proof of purchase as well as any documents
FLEXTHERM may require.
WHAT FLEXTHERM WILL/WILL NOT DO: FLEXTHERM's obligations
under this Limited Warranty are limited to, at its sole discretion, repairing or
replacing the thermostat originally supplied in the Product that
FLEXTHERM has determined to be defective in materials or workmanship.
FLEXTHERM shall replace the defective thermostat goods free of charge
“ex works” after the originals have been returned to us postage/freight
prepaid. Replacement will only be made for defective parts; and no
allowance or reimbursement shall be made for wages, labour and freight
costs. With respect to the parts not manufactured by ourselves, we shall
only warrant for these to the same extent as our suppliers undertake a
warranty obligation towards ourselves.
Because of its ongoing commitment to product quality and innovation,
FLEXTHERM reserves the rights, at any time and without incurring any
obligations, to revise, change, modify or discontinue any specifications,
features, designs or components.
INSTALLATION REQUIREMENTS: In addition to the requirements included
in the current FLEXTHERM Installation Guide, which is incorporated herein
by this reference, the Product must be installed in accordance with
accepted standards.
WARNING: Failure to install the Product in conformity with your
local electrical Codes, as well as the Installation Guide, may
cause fires. Failure to install the Product according to the
directives in the installation guide may damage the cables/
wiring and lead to Product failures, which are not covered under
the Limited Warranty.
EXCLUSIONS, ARE NOT WARRANTED: Failures resulting from improper
installation; Damage caused by abuse, improper installation, repairs,
service, maintenance and/or storage, modifications or use of parts not
manufactured or supplied by FLEXTHERM; Damage caused by abuse or
neglect; regarding the Product; Damage caused by water, submersion,
accident, fire or any act of God; Incidental, consequential or other damages
(including labor costs, towing, inconvenience, loss of time or loss of
income).
LIMITATIONS OF LIABILITY:
THIS WARRANTY IS EXPRESSELY GIVEN AND ACCEPTED IN LIEU
ANY AND ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING WITHOUT ANY LIMITATION ANY WARRANTY OF
MERCHANTABILITY OR FITNESS OR A PARTICULAR PURPOSE. TO
THE EXTENT THAT THEY CANNOT BE DISCLAIMED, THE IMPLIED
WARRANTIES ARE LIMITED IN DURATION TO THE LIFE OF THE
EXPRESSED LIMITED WARRANTY. INCIDENTAL AND
CONSEQUENTIAL DAMAGES ARE EXCLUDED FROM COVERAGE
UNDER THIS LIMITED WARRANTY. SOME PROVINCES DO NOT
ALLOW FOR THE DISCLAIMERS, LIMITATIONS AND EXCLUSIONS
IDENTIFIED ABOVE; AS A RESULT, THEY MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC RIGHTS WHICH MAY VARY
FROM PROVINCE TO PROVINCE.
Neither FLEXTHERM re-sellers, installers or any other person is entitled or
authorized to make any affirmation, representation or warranty other than
those contained in this Limited Warranty. If the ownership of the Product is
transferred during the Limited Warranty Coverage period, the terms and
conditions of the Limited Warranty shall apply to the new owner, provided
the new owner has proof, satisfactory to FLEXTHERM, of the date of first
purchase of the Product.
FLEXTHERM Canada Inc.
2400 de la Province Street
Longueuil, Quebec J4G 1G1 Canada
1 800 FLEXTHERM (353-9843)
(450) 442-9990
1 877 FLEXTHERM (353-9843)
(450) 442-1099
www.flextherm.com
TEMPERATURE CONTROL
1 to 24% 25 to 49% 50 to 74% 75 to 99% 100%
SPECIFICATIONS
AF F
Temperature
display range:0°C to 70°C
(32°F to 158°F) 0°C to 70°C
(32°F to 158°F)
Temperature
setting range:5°C to 30°C
(40°F to 86°F) 5°C to 40°C
(40°F to 104°F)
Comfort
setpoint:21°C (70°F) 28°C (82°F)
Economy
setpoint:16.5°C (62°F) 20°C (68°F)
Vacation
setpoint:10°C (50°F)
WARRANTY
As an Energy Star® partner, Flextherm Inc.
has determined that this product meets the
Energy Star guidelines for energy efficiency.
400-610-000-E (Flextherm FLP12 prog CAN) ENG.fm Page 4 Friday, September 14, 2007 4:13 PM
Table of contents
Other Flextherm Thermostat manuals

Flextherm
Flextherm FLP30 User manual

Flextherm
Flextherm FLP35 User manual

Flextherm
Flextherm FLP30-120 User manual

Flextherm
Flextherm INSTINCT Connect FLP45-120/240GA User manual

Flextherm
Flextherm LS240P User manual

Flextherm
Flextherm FLE30 series User manual

Flextherm
Flextherm INSTINCT FLP40-120/240GA User manual

Flextherm
Flextherm FLP12-GA User manual

Flextherm
Flextherm LS120P User manual

Flextherm
Flextherm FLK31 User manual