manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fluke
  6. •
  7. Adapter
  8. •
  9. Fluke BC190/830 User manual

Fluke BC190/830 User manual

BC190/830
Universal Mains-Power Adapter
Instruction Sheet
Introduction
The BC190/830 is a universal mains-power adapter (the Adapter or
Product) for measurement, control, and laboratory equipment. The
Adapter is intended for operating and charging the Fluke 190-Series
ScopeMeter Test Tool (test tool). TheAdapter is based on the switched-
mode concept for high efciency, low stand-by power consumption, and
complies with level-VI requirements. It operates in a wide range of input
voltages from 100 Vac up to 240 Vac nominal.
A universal set of mains cords is included to make the Adapter suitable
for most types of mains outlet.
How to Contact Fluke
To contact Fluke, call one of the following telephone numbers:
Symbols
International electrical symbols used on the Product and in this document
are explained below.
Symbol Description
WARNING - RISK OF DANGER. Consult user documentation.
WARNING. HAZARDOUS VOLTAGE. Risk of electric shock.
DC (Direct Current)
Double Insulated
Conforms to European Union directives.
VI
Energy Efciency Level VI

This product complies with the WEEE Directive marking
requirements. The afxed label indicates that you must not discard
this electrical/electronic product in domestic household waste.
Product Category: With reference to the equipment types in the
WEEE Directive Annex I, this product is classed as category 9
“Monitoring and Control Instrumentation” product. Do not dispose of
this product as unsorted municipal waste.
Conforms to relevant South Korean EMC Standards.
Certied by ETL Intertek to North American safety standards.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for one
year from the date of purchase. This warranty does not cover fuses, disposable
batteries, or damage from accident, neglect, misuse, alteration, contamination,
or abnormal conditions of operation or handling. Resellers are not authorized to
extend any other warranty on Fluke’s behalf. To obtain service during the warranty
period, contact your nearest Fluke authorized service center to obtain return
authorization information, then send the product to that Service Center with a
description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH
AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED.
FLUKE IS NOT LIABLE FORANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR
THEORY. Since some states or countries do not allow the exclusion or limitation
of an implied warranty or of incidental or consequential damages, this limitation of
liability may not apply to you.
11/99
Shop for Fluke products online at: 1.800.561.8187
www.MyFlukeStore.ca
Safety Information
A Warning identies conditions and procedures that are dangerous to the
user.  Warning
To prevent electrical shock, re, or personal injury:
• Read these instructions carefully before using the Product.
• Use the Product only with Fluke test tools that have the type
number ‘BC190’ specied for charge and operation.
• Use this Product only as specied.
• Do not open the Product, it has no user-serviceable parts inside.
• Do not use the Product around explosive gas, vapor, or in damp or
wet environments.
• Use this Product indoors only.
• Examine the case before you use the Product. Look for cracks or
missing plastic. Carefully look at the cable jacket and insulation
around the terminals.
• Use only the mains power cord and connector approved for the
voltage and plug conguration in your country and rated for the
Product.
• Replace the mains power cord if the insulation is damaged or if the
insulation shows signs of wear.
• Do not use the Product if it is altered or damaged.
Unpack
The Adapter includes these items:
• BC190/830 Switch Mode Power Adapter (main unit) with dc cable
• Universal set of 2-wire mains cords with male and female connector
At delivery of the Adapter, make sure that the shipment is complete and all
items are undamaged. Contact your supplier if you see any damage.
Operation
The power cord connects the Adapter to the mains system. Do not block
access to the power cord and power plug, these must remain accessible to
the user at all times.
The Adapter is not equipped with a power switch. Disconnect the mains
plug from the mains system when not in use.
In case the Adapter is damaged or any damage is suspected, disconnect
from the mains system and have qualied service personnel inspect the
Adapter before reconnecting to the mains system again.
To use:
1. Connect the mains cord to the Adapter.
2. Connect the power plug to the mains system.
3. Connect the dc plug to the test tool.
For continuous operation and recording with the test tool, keep the power
adapter connected.
The Adapter operates and charges the test tool from local line voltage.
Any power supply connected to the test tool introduces a certain capacitive
coupling between the test tool and ground through the power supply
circuitry. This capacitive coupling can affect test tool measurements. The
Adapter is equipped with dedicated decoupling networks to reduce possible
effects of such capacitive coupling during measurements.
For an optimal decoupling from ground, especially to make low-level
measurements, Fluke recommends that you work in battery-operated mode
without any power adapter connected. See the User Manual for the test tool
to nd complete safety information before making any measurements.
Note
Always fully charge the test tool battery before storage.
Specications
Input
Nominal input voltage ...............100 Vac to 240 Vac, ±10 %
Input current..............................0.35 A at max. load
Nominal input frequency...........50/60 Hz ±10 %
Mains inlet.................................IEC 60320-1 type C8
Input power, no load..................<0.1 W (@ 115 / 230 Vac)
Output
Output voltage...........................18 Vdc ±5 %
Output current...........................0 mAto 840 mA
Output cable length...................2 m (6.5 ft)
Output connector......................5 mm outer diameter, per DIN45232
Output polarity...........................Inner contact negative, outer contact positive
Physical characteristics
Dimensions of main unit............79 mm x 149 mm x 49 mm
Housing material.......................Heat resistant ABS
Color (housing and cable).........Black
Weight.......................................0.35 kg
Ingress Protection.....................IEC 60529, IP40
Environmental..............................
Operating temperature..............0 °C to 50 °C (32 °F to 122 °F), up to 90 % rel.
humidity, no condensation
Storage temperature.................-40 °C to +70 °C, 10 % to 95 % rel. humidity
Max. altitude..............................2000 m (6562 ft) above sea-level
Included accessories
Power cord................................Universal set of 2-wire cords
Mains cord length......................1.8 m (6 ft), male to female
Power plug adapters.................US-style, UK-style, European, Japanese,
Chinese/Australian, Brazilian
Safety............................................IEC 61010-1, IEC 61010-2-030: CAT IV 600 V,
Pollution Degree 2
Electromagnetic
Compatibility (EMC) ....................IEC 61326-1: Industrial Electromagnetic
Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or use conductively
coupled radio-frequency energy which is necessary for the internal functioning
of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than
domestic and those directly connected to a low voltage power supply network
which supplies buildings used for domestic purposes. There may be potential
difculties in ensuring electromagnetic compatibility in other environments,
due to conducted and radiated disturbances.
Korea (KCC)................................Class AEquipment (Industrial Broadcasting &
Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is
intended for use in business environments and not to be used in homes.
Shop for Fluke products online at: 1.800.561.8187
www.MyFlukeStore.ca

Other Fluke Adapter manuals

Fluke BC430 User manual

Fluke

Fluke BC430 User manual

Fluke 5320A-LOAD User manual

Fluke

Fluke 5320A-LOAD User manual

Fluke 174x User manual

Fluke

Fluke 174x User manual

Fluke Norma Star Point Owner's manual

Fluke

Fluke Norma Star Point Owner's manual

Fluke 17XX-CLAMP-ADPT-2V8 User manual

Fluke

Fluke 17XX-CLAMP-ADPT-2V8 User manual

Fluke DTX-COAX User manual

Fluke

Fluke DTX-COAX User manual

Fluke DIS 90 User manual

Fluke

Fluke DIS 90 User manual

Fluke BC500 User manual

Fluke

Fluke BC500 User manual

Fluke BC190/830 User manual

Fluke

Fluke BC190/830 User manual

Fluke BC430/830 User manual

Fluke

Fluke BC430/830 User manual

Fluke BC190/820 User manual

Fluke

Fluke BC190/820 User manual

Fluke DSX-PLA004S User manual

Fluke

Fluke DSX-PLA004S User manual

Fluke DSX-PC Series User manual

Fluke

Fluke DSX-PC Series User manual

Fluke DSP-PM11A User manual

Fluke

Fluke DSP-PM11A User manual

Fluke DTX-PLA002PRP User manual

Fluke

Fluke DTX-PLA002PRP User manual

Fluke SV225 User manual

Fluke

Fluke SV225 User manual

Fluke Zero Adapter User manual

Fluke

Fluke Zero Adapter User manual

Fluke BC430/830 User manual

Fluke

Fluke BC430/830 User manual

Fluke BC190 User manual

Fluke

Fluke BC190 User manual

Fluke ir3000 User manual

Fluke

Fluke ir3000 User manual

Fluke 17 Series User manual

Fluke

Fluke 17 Series User manual

Fluke ir3000 FC User manual

Fluke

Fluke ir3000 FC User manual

Fluke BC190/830 User manual

Fluke

Fluke BC190/830 User manual

Fluke DSX-CHA021S User manual

Fluke

Fluke DSX-CHA021S User manual

Popular Adapter manuals by other brands

Linksys WAPPOE user guide

Linksys

Linksys WAPPOE user guide

Motorola WN825G user guide

Motorola

Motorola WN825G user guide

StarTech.com 2CF2SATAR instruction manual

StarTech.com

StarTech.com 2CF2SATAR instruction manual

Keysight Technologies 11920A User's and service guide

Keysight Technologies

Keysight Technologies 11920A User's and service guide

Rocstor Y10A248-B1 user manual

Rocstor

Rocstor Y10A248-B1 user manual

TP-Link WN-512AG user guide

TP-Link

TP-Link WN-512AG user guide

mumbi m-RA1500 user manual

mumbi

mumbi m-RA1500 user manual

BenQ AWL400 user manual

BenQ

BenQ AWL400 user manual

StarTech.com USB2VGAE2 instruction manual

StarTech.com

StarTech.com USB2VGAE2 instruction manual

Equinox Systems MEGAPORT Read this first

Equinox Systems

Equinox Systems MEGAPORT Read this first

Motorola Vonage VT2542 quick start guide

Motorola

Motorola Vonage VT2542 quick start guide

AOpen AOI-811 user manual

AOpen

AOpen AOI-811 user manual

METREL A1207 instruction manual

METREL

METREL A1207 instruction manual

Digital Antenna DA298 Specification sheet

Digital Antenna

Digital Antenna DA298 Specification sheet

D-Link DWL-122 manual

D-Link

D-Link DWL-122 manual

NETGEAR XAVB5501 installation guide

NETGEAR

NETGEAR XAVB5501 installation guide

PCTV Systems 460e quick start guide

PCTV Systems

PCTV Systems 460e quick start guide

HighPoint RocketRAID 3520 user guide

HighPoint

HighPoint RocketRAID 3520 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.