5000 Meters RF Wireless Receiver (Model 0020690 S2UW-AC-ANT3)
Package Include:
1 x Receiver: S2UW-AC-ANT3
1 x User manual
Feature:
Application: It can be used in industry automation, agriculture automation and home automation, such as factory, house, farm, pasture, vehicle, ship,
offshore operation, aerial vehicle, field call, etc. It can remote control equipments on land, water and air, such as remote control lights, sirens, locks,
motors, fans, winches, blinds, linear actuators, doors, windows, electric solenoid valves, security alarm, business signs and various devices.
The installation of wireless control is easy and fast.
Super long range, with a transmitter to form a complete set, the working distance can reach 5000m in an open ground.
Waterproof: The receiver has waterproof case and waterproof connector, it can be installed outdoors.
AC Power Output: It can control AC equipment with voltage 110V / 120V / 220V / 240VAC.
Relay Output: This receiver is relay output, it can be used to operate both DC and AC equipments. The terminal is NO / NC (normally open / normally
closed), which serves as a switch. That means you should also connect a separate power supply to equipments.
With wired control terminals: You can connect sensors, limit switches, manual switches or external devices to control the receiver.
With the external antenna, it can have a further working range.
You can control the equipments by using the receiver with transmitter (remote control) from any place within a reliable distance.
Wireless RF signal can pass through walls, floors, doors or windows.
With characteristics of reverse power protection and over current protection.
Reliable control: The code has thousands of different combinations, and the receiver only works with the transmitter which use the same code..
One/several transmitters can control one/several receivers simultaneously.
You can use two or more units in the same place.
Feedback function:
The receiver and the transmitter have a Two-way working mode, and the user can know the working status of receiver by the transmitter in such a
long distance.
Two-way working mode: When you press the remote control to send RF signal to the receiver, if the receiver has been successfully triggered or
operated, the receiver will immediately transmit a RF feedback signal to the remote control. Then the remote control will send out a buzzing sound to
inform you that the receiver has been successfully operated.
Receiver Parameters:
Model No.: S2UW-AC220-ANT3
Power Supply (Operating Voltage): AC100~240V (110V/120V/220V/240V)
Output: Relay output (Normally open and normally closed)
Working Voltage Range of Relay: AC110~240V or DC0~28V
Working Frequency: 433.92MHz
Channel: 2 CH
Control Modes: Toggle, Momentary, Latched
Static Current: ≤6mA
Maximum Working Current: 10A / each channel
Wire range:22~11AWG
PCB size: 88mm x 80mm x 18mm
Case size: 115mm x 90mm x 55mm
External Telescopic Antenna:
Length of external telescopic antenna: 108mm / 445mm (stretch)
With SMA connector.
If you stretches the external telescopic antenna, it can have a further working range.
Matching Transmitters:
This receiver only works with 5000m transmitters, such as model CC-2 / CC-4 (5000M), or CCW-2 / CCW-4 (5000M, waterproof).
When you set the receiver in toggle mode or momentary mode, it should work with two buttons transmitter, such as model CC-2 (5000m), or CCW-2
(5000m, waterproof). When you set the receiver in latched mode, it should work with four buttons transmitter, such as model CC-4 (5000m), CCW-4
(5000m, waterproof).
Working Range:
Super long range, with a transmitter (such asCC-2) to form a complete set, the maximum working distance can reach 5000M in an open ground.
The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will
be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this
maximum working distance.
Usage (with the transmitter CC-2):
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state of relay output terminals: Terminals “NO”and “COM”are Normally Open;
Terminals “NC”and “COM”are Normally Closed.
Wiring:
If you want to control a DC 12V lamp, do as following:

SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: sale@carymart.com
1) Connect the positive pole of DC power supply to terminal “L / +”, and connect the negative pole of DC power supply to terminal “N / -”.
2) Connect terminal “NO”to the positive pole of DC power supply, connect terminal “COM”to the positive pole of DC lamp, and connect the negative
pole of DC lamp to the negative pole of DC power supply.
If you want to control anAC 220V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “L / +”, and connect the negative pole of DC power supply to terminal “N / -”.
2) Connect terminal “NO”to the live wire of AC power supply, connect terminal “COM”to one side of AC lamp, and connect another side of AC lamp
to the neutral wire of AC power supply.
Setting different control modes:
We have set the receiver in toggle mode before delivery, if you want to use other modes, do as following operation.
1) Setting control mode Toggle: Turn on the first bit of the dip switch.
Control mode Toggle (with transmitter CC-2): Press -> On; Press again -> Off.
Press the first button of the transmitter: Turn on the relay1 (connect terminals “NO1”and “COM1”, disconnect terminals “NC1”and “COM1”), the lamp
1 is turned on.
Press the first button of the transmitter again: Turn off the relay1 (disconnect terminals “NO1”and “COM1”, connect terminals “NC1”and “COM1”),
the lamp 1 is turned off.
Press the second button of the transmitter: Turn on the relay 2 (connect terminals “NO2”and “COM2”, disconnect terminals “NC2”and “COM2”), the
lamp 2 is turned on.
Press the second button of the transmitter again: Turn off the relay 2 (disconnect terminals “NO2”and “COM2”, connect terminals “NC2”and
“COM2”), the lamp 2 is turned off.
2) Setting control mode Momentary: Turn on the first and the second bits of the dip switch.
Control mode Momentary (with transmitter CC-2): Press and hold -> On; Release -> Off.
Press and hold the first button of the transmitter: Turn on the relay1 (connect terminals “NO1”and “COM1”, disconnect terminals “NC1”and “COM1”),
the lamp 1 is turned on.
Release the first button: Turn off the relay1 (disconnect terminals “NO1”and “COM1”, connect terminals “NC1”and “COM1”), the lamp 1 is turned off.
Press and hold the second button of the transmitter: Turn on the relay 2 (connect terminals “NO2”and “COM2”, disconnect terminals “NC2”and
“COM2”), the lamp 2 is turned on.
Release the second button: Turn off the relay 2 (disconnect terminals “NO2”and “COM2”, connect terminals “NC2”and “COM2”), the lamp 2 is
turned off.
3) Setting control mode Latched: Turn on the second bit of the dip switch.
Control mode Latched (with transmitter CC-4): Press buttonA -> On; Press button B -> Off.
Press buttonA of the transmitter: Turn on the relay 1, the lamp 1 is turned on.And turn off the relay 2 at the same time, the lamp 2 is turned off.
Press button B of the transmitter: Turn on the relay 2, the lamp 2 is turned on. And turn off the relay 1 at the same time, the lamp 1 is turned off.
Press button C/D of the transmitter: Turn off two relays 1 and 2, two lamps 1 and 2 are turned off.
Wired control terminals:
The receiver has wired control terminals, you can connect external devices, sensors, limit switches or manual switches to trigger the receiver.
1) By low level signal:
You can connect external devices (with low level output signal) to trigger the receiver.
When external device outputs low level signal to terminals 1 and 3, turn on the relay 1, and the lamp 1 is turned on.
When external device stops to output signal, turn off the relay 1, and the lamp 1 is turned off.
When external device outputs low level signal to terminals 2 and 3, turn on the relay 2, and the lamp 2 is turned on.
When external device stops to output signal, turn off the relay 2, and the lamp 2 is turned off.
2) By NO/NC contact:
You can connect manual switches (with NO/NC contact) to trigger the receiver.
When connect terminals 1 and 3 by manual switch, turn on the relay 1, and the lamp 1 is turned on.
When disconnect terminals 1 and 3 by manual switch, turn off the relay 1, and the lamp 1 is turned off.
When connect terminals 2 and 3 by manual switch, turn on the relay 2, and the lamp 2 is turned on.
When disconnect terminals 2 and 3 by manual switch, turn off the relay 2, and the lamp 2 is turned off.
Setting feedback function:
If you want to switch on the feedback function, you need to turn on the third bit of the dip switch.
When the receiver gets the signal of transmitter, it will immediately send a return signal to the transmitter. When the transmitter receive the feedback
signal of the receiver, the transmitter will exude a buzzing sound like “D~”which means it receive the feedback signal successfully.
How to pair the transmitter to the receiver:
1) Press the learning button of receiver for 1- 2 seconds; signal LED on the receiver is turned on. The receiver starts the LEARNING procedure.
2) Press any one button on transmitter, if signal LED flashes twice, it means learning is successful.
3) The receiver can learn several transmitters with different codes.
Delete all transmitters:
We have learned remote control to the receiver. If you don’t want the receiver to work with the remote control, you can delete all codes of remote
controls, which are stored in the receiver.

SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: sale@carymart.com
Operation: Press and hold the button of receiver until signal LED flashes three times. That means all stored codes have been deleted successfully.
Live wire
L/+
AC Power supply
Control DC Lamp
DC Lamp 1
Relay 1
+
_
Manual Terminals
3
2
1
Neutral wire
wire
Status LED 1
Power LED
N/-
NC1
NO1
COM1
DC Power supply
Live wire
L/+
AC Power supply
Control AC Lamp
AC Lamp 1
Relay 1
Manual Terminals
3
2
1
Neutral wire
wire
Status LED 1
Power LED
N/-
NC1
NO1
COM1
AC Power supply
L
N
DC Lamp 2
Relay 2
+
_
Status LED 2
NC2
NO2
COM2
DC Power supply
AC Lamp 2
Relay 2
Status LED 2
NC2
NO2
COM2
AC Power supply
L
N
1
3
2
ON
Signal LED
Learning Button
Dip switch
1
3
2
ON
Signal LED
Learning Button
Dip switch
This manual suits for next models
1
Table of contents
Other Flying Industry Development Receiver manuals

Flying Industry Development
Flying Industry Development 0020670 User manual

Flying Industry Development
Flying Industry Development S2UA-DC12 User manual

Flying Industry Development
Flying Industry Development 0020423 User manual

Flying Industry Development
Flying Industry Development S2UW-DC-ANT3 User manual

Flying Industry Development
Flying Industry Development 0020112 User manual

Flying Industry Development
Flying Industry Development 0020535 User manual