Flying Industry Development S2UA-DC12 User manual

SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: sale@carymart.com
RF Wireless Receiver (Model 0020195 S2UA-DC12)
Package Include:
1 x Receiver: S2UA-DC12
1 x User manual
Feature:
Application: It can be used in industry automation, agriculture automation and home automation, such as factory, house, farm, pasture, vehicle, ship,
offshore operation, aerial vehicle, field call, etc. It can remote control equipments on land, water and air, such as remote control lights, sirens, locks,
motors, fans, winches, blinds, linear actuators, doors, windows, electric solenoid valves, security alarm, business signs and various devices.
Wireless control, easy to install.
Waterproof: The receiver has waterproof case and waterproof connector, it can be installed outdoors.
Relay Output: This receiver is relay output, it can be used to operate both DC andAC equipments. The terminal is NO / NC (normally open / normally
closed), which serves as a switch. That means you should also connect a separate power supply to it.
With wired control terminals: You can connect sensors, limit switches, manual switches or external devices to control the receiver.
Design with low-power and high-speed CMOS technology.
You can turn on/ off the receiver with transmitter (remote control) from any place within a reliable distance.
Wireless RF signal can pass through walls, floors, doors or windows.
With reverse power protection and over current protection.
Reliable control: The receiver only works with the transmitter which use same code.
One/several transmitters can control one/several receivers simultaneously.
You can use two or more units in the same place.
Receiver Parameters:
Model No.: S2UA-DC06 / S2UA-DC09 / S2UA-DC12 / S2UA-DC24
Power Supply (Operating Voltage): DC6V (S2UA-DC06), DC9V±1V (S2UA-DC09), DC12V±1V (S2UA-DC12), DC24V±2V (S2UA-DC24)
Output: Relay output (Normally open and normally closed)
Working Voltage Range of Relay: AC110~240V or DC0~28V
Working Frequency: 315MHz / 433MHz
Channel: 2 CH
Control Modes: Toggle, Momentary, Latched, Momentary + Toggle
Static Current: ≤6mA
Maximum Working Current: 10A / each channel
Wire range:22~11AWG
PCB size: 88mm x 80mm x 18mm
Case size: 115mm x 90mm x 55mm
Work with Fixed code transmitters or Learning code transmitters.
Matching Transmitters:
The receiver can work with different transmitters, such as model C-2 / C-3 (100M), CWB-2 / CWB-3 (50M, waterproof), CP-2 / CP-4/CV-4 (500M), or
CB-2 / CB-3 (1000M) etc.
When you set the receiver in toggle or momentary mode, it should work with two buttons transmitter, such as model C-2 (100M), CWB-2 (50M,
waterproof), CP-2 (500M), or CB-2 (1000M) etc. When you set the receiver in latched mode, it should work with two buttons transmitter, such as
model C-3 (100M), CWB-3 (50M, waterproof), CP-4 (500M), CV-4 (500M), or CB-3 (1000M) etc.
Working Range:
With a transmitter (such as C-2) to form a complete set, the maximum working distance can reach 100M in an open ground.
The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will
be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this
maximum working distance.
If you want to have a further working range, you can install an external antenna to the receiver, and you also can use a powerful transmitter, such as
CB transmitters.
Usage (with the transmitter C-2):
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state of relay output terminals: Terminals “NO”and “COM”are Normally Open;
Terminals “NC”and “COM”are Normally Closed.
Wiring:
If you want to control a DC 12V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “L / +”, and connect the negative pole of DC power supply to terminal “N / -”.
2) Connect terminal “NO”to the positive pole of DC power supply, connect terminal “COM”to the positive pole of DC lamp, and connect the negative
pole of DC lamp to the negative pole of DC power supply.
If you want to control anAC 220V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “L / +”, and connect the negative pole of DC power supply to terminal “N / -”.
2) Connect terminal “NO”to the live wire of AC power supply, connect terminal “COM”to one side of AC lamp, and connect another side of AC lamp
to the neutral wire of AC power supply.
Setting different control modes:

SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: sale@carymart.com
Setting different control modes (We have set the receiver as Toggle control mode before delivery. If you want to use other control modes, do as
following operation):
Setting control mode Toggle: Only connect Jumper-2.
Control mode Toggle (with transmitter C-2): Press -> On; Press again -> Off.
Press the button 1 of the transmitter: Turn on the relay 1 (connect “COM1”and “NO1”, disconnect “NC1”and “COM1”), the lamp 1 is on.
Press the button 1 again: Turn off the relay 1 (disconnect “COM1”and “NO1”, connect “NC1”and “COM1”), the lamp 1 is off.
Press the button 2 of the transmitter: Turn on the relay 2 (connect “COM2”and “NO2”, disconnect “NC2”and “COM2”), the lamp 2 is on.
Press the button 2 again: Turn off the relay 2 (disconnect“COM2”and “NO2”, connect “NC2”and “COM2”), the lamp 2 is off.
Setting control mode Momentary: Only connect Jumper-1.
Control mode Momentary (with transmitter C-2): Press and hold -> On; Release -> Off.
Press and hold button 1 of the transmitter: Turn on the relay 1 (connect “COM1”and “NO1”, disconnect “NC1”and “COM1”), the lamp 1 is on.
Release the button 1: Turn off the relay 1 (disconnect“COM1”and “NO1”, connect “NC1”and “COM1”), the lamp 1 is off.
Press and hold button 2 of the transmitter: Turn on the relay 2 (connect “COM2”and “NO2”, disconnect “NC2”and “COM2”), the lamp 2 is on.
Release the button 2: Turn off the relay 2 (disconnect“COM2”and “NO2”, connect “NC2”and “COM2”), the lamp 2 is off.
Setting control mode Latched: Do not connect Jumper-1 and Jumper-2.
Control mode Latched (with transmitter C-3): Press button -> On; Press another button -> Off.
Press button C of the transmitter: Turn on the relay 1, the lamp 1 is on; and turn off the relay 2, the lamp 2 is off.
Press button B of the transmitter: Turn on the relay 2, the lamp 2 is on; and turn off the relay 1, the lamp 1 is off.
Press button A of the transmitter: Turn off two relays, two lamps are off.
Setting control mode Momentary + Toggle (with transmitter C-2): Connect Jumper-1 and Jumper-2
Control mode Momentary (Channel 1): Press and hold -> On; Release -> Off.
Press and hold button 1 of the transmitter: Turn on the relay 1, the lamp 1 is on.
Release the button 1: Turn off the relay 1, the lamp 1 is off.
Control mode Toggle (Channel 2): Press -> On; Press again -> Off.
Press the button 2 of the transmitter: Turn on the relay 2, the lamp 2 is on.
Press the button 2 again: Turn off the relay 2, the lamp 2 is off.
Wired control terminals:
The receiver has manual control terminals, you can connect external devices, sensors, or manual switches to control the receiver.
1) Signal input:
You can connect external devices (with low level output signal) to manual terminals 1 (Signal +), 2 (Signal +), and terminal 3 (Signal -) , then the
external device’s output signal can control the receiver.
When the external device outputs low level signal to manual terminal 1 and terminal 3, turn on the relay 1, the lamp 1 is on.
When the external device stops to output signal, turn off the relay 1, the lamp 1 is off.
When the external device outputs low level signal to manual terminal 2 and terminal 3, turn on the relay 2, the lamp 2 is on.
When the external device stops to output signal, turn off the relay 2, the lamp 2 is off.
2) The manual switches:
You can connect manual switches to manual terminals 1, 2 and 3, then you can use manual switches to control the receiver.
When connect terminals 1 and 3, turn on the relay 1, the lamp 1 is on.
And when disconnect terminals 1 and 3, turn off the relay 1, the lamp 1 is off.
When connect terminals 2 and 3, turn on the relay 2, the lamp 2 is on.
And when disconnect terminals 2 and 3, turn off the relay 2, the lamp 2 is off.
How to pair the transmitter to the receiver:
1) Press the learning button of receiver for 1- 2 seconds; signal LED on the receiver is on. The receiver enters into status of LEARNING.
2) Press any one button on transmitter. If signal LED flashes quickly 15 times and turns off, it means learning is successful.
3) When receiver is in the status of LEARNING, press again the button of receiver, signal LED turns off, learning process will be discontinued.
4) The receiver can learn several remote controls with different codes.
Delete all transmitters:
We have learned remote control to the receiver. If you don’t want the receiver to work with the remote control, you can delete all codes of remote
controls, which are stored in the receiver.
Operation: Press and hold the button of receiver until signal LED flashes slowly; release the button, LED keeps slow flash. That means all stored
codes have been deleted successfully.

SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com E-Mail: sale@carymart.com
Signal LED
Button
L/+
Control DC Equipment
DC Lamp 1
Relay 1
+
_
Manual Terminals
3
2
1
Status LED 1
Power LED
IC
Jumper-2
Jumper-1
N/-
NC1
NO1
COM1
Antenna
RF module
DC Power supply
Signal LED
Button
L/+
Control AC Equipment
AC Lamp 1
Relay 1
Manual Terminals
3
2
1
Status LED 1
Power LED
IC
Jumper-2
Jumper-1
N/-
NC1
NO1
COM1
Antenna
RF module
AC Power supply
L
N
DC Lamp 2
Relay 2
+
_
Status LED 2
NC2
NO2
COM2
DC Power supply
AC Lamp 2
Relay 2
Status LED 2
NC2
NO2
COM2
AC Power supply
L
N
-
+
DC Power supply
-
+
DC Power supply
This manual suits for next models
1
Table of contents
Other Flying Industry Development Receiver manuals

Flying Industry Development
Flying Industry Development S2UW-DC-ANT3 User manual

Flying Industry Development
Flying Industry Development 0020535 User manual

Flying Industry Development
Flying Industry Development 0020423 User manual

Flying Industry Development
Flying Industry Development S2UW-AC-ANT3 User manual

Flying Industry Development
Flying Industry Development 0020670 User manual

Flying Industry Development
Flying Industry Development 0020112 User manual