manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. foc.us
  6. •
  7. Security Sensor
  8. •
  9. foc.us MC-7380R User manual

foc.us MC-7380R User manual

ON
1 2 3 4
MC-7380R Wireless PIR Intrusion Detector
MC-7380R is an intrusion detector with energy accumulation
processing and dynamic Metixing time chip. Its built-in Fresnel
increases the energy receiving efficiency, and the sensitivity is
high without false alarm,furthermore, it can distinguish which
factor may cause false alarm.
Optional impulse insures it suitable for indoor with digital micro-
processing.Advanced true motion recognition technology enables
recognize the intruder from other interfering factors. Multi-mode
and capability optional,which fit forvarious indoor environment and
solve all kinds of interference,prevent false alarmand loss alarm.
1.Introduction
2.Specification
Model: MC-7380R
Operating Voltage: 4.5V
Quiescent Current: ≤25Ua
Alarm maximum current: ≤15mA
Launch distance: ≤150m(in the open area)
Launch frequency: 433/868MHz
Detect the maximum radius: 5m/25℃
Heartbeat report: send heartbeat report once
at short intervals, interval time <3 hours
Optical lens data
Infrared area: 12+12+6+1
Maximum coverage area: 10 * 10m (33 * 33 feet)
Alarm indicator: Red LED lights up and goes out,
then Blue LED lights.
XXX
3~5m
The installation height
is 3~5m
Preventing pets over 20kg
enter the detection area
Don’t install on a unstable base
Don’t face the sunshine
directly
Don’t face cold or
heat directly
3m 90°
23°
47°
70°
0m 2m
2m 4m
4m 6m
0m 2m
2m 4m
4m 6m
6m
0m 2m
2m 4m
4m 6m
6m
0m
2m
4m
6m
2m
4m
6m
Installation:
Installation way: ceiling installation
Installation height: 3 ~ 5m, between the back
cover and the wall without angle
Environment
Working temperature:-10℃ to 50℃(14°F to 122°F)
Storage temperature:-20℃ to 60℃ (-4°F to 140°F)
Anti white (indoor): >90001ux
Dimension: φ111*40(H)mm
3.1 General Guidelines
3.Installation
3.2 Illustrated Installation Procedure
LED indicator
Passive infrared channel
Tamper switch
ON
1 2 3 4
DIP switch
2. Mount base: 3 – 5m above ground A. Secure the base
to the mounting
position with screws
A. Press the cover
circum rotates it
counter clock wise
to open itd
1.Disassemble
unit:
Screw holes
B. Align the base
triangle with the
top cover
C. Hold the cover
clockwise to
tighten it
Triangle
logo
3.3 Change Battery
When the detector batlery is weak, it will
send out signalto the control panel, at the
same time, you need to change battery for
the detector. Draw the PCB board; follow the
steps as below to change new battery.(as right picture).
ON
1 2 3 4
P/N:20170504A03
Figure 1. General View Figure 2. Inside View
MC-7380R top view
MC-7380R side view
-1-
Even the most sophisticated detcetors can sometimes be defeated or may fail to warn due to :DC power failure/improper connection,
malicious mask-ing of the lens,tampering with the optical system, decreased sensitivity in ambient temperatures near that of the human
body and unexpected failure of a component part.The above list includes the most common reasons for failure recommended that the
detector and the entire alarm system be checked weekly, to ensure proper performance.
An alarm system should not be regarded as a substitute for insurance. Home & property owners or renters sh-ouldbe prudent enough
to continue insuring their lives & property, even though they are protected by an alarm system.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant harmful interference in residential
installations .This equipment generates,uses and can radiate radio frequency energy and ,if not installed and used in accordance with the
instructions ,may cause harmful interference to radio and t-elevision reception. However, there is no guarantee that interference will not
occur in aparticular installation .If this device does cause such interference , which can be ver-fied by turning the device off and on ,the
user is encouraged to eliminate the interference by one or more of the followingmeasures:
-Increase the distance between the device and the receiver.
-Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
-Consult the dealer or an expericnced radio/TV technician.
WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could avoid the user s
authority to operate the equipment
1.Start the test at least 2 minutes after connecting
power supply
2. Walking breadthwise at the remote and of the
detection coverage , then will trigger the detector
and the LED indications 2-3seconds
3.Testing in different direction to confirm the two boundaries of the
coverage, ensure the detector is appoint to the central desired area.
4. From the detector 3-6 meters, slowly raise arm, and into the detection
area, mark the lower boundary of passive infrared alarm. Repeat the above practice to determine its upper boundary.
5, the center of detection zone should not uphill incline. To obtain a good detection range , please adjust the vertical detection range,
en-sure the detector is in a correct position.
Note: Guide the user to perform a walk test at least once a week in order to ensure that each detector is in good condition.
5. Perform walking test to the detection area
install the cover and close the fasten part Put the
cover back, and circle the foundation clock wise
till match well
NO. 0N 0FF
4 Low sensitivity High sensitivity
3 Alarm delay 5 minutes Alarm without delay
2 LED Open LED Close
1 Tamper invalid Tamper effective
ON
1 2 3 4
ON
1 2 3 4
4.DIP switch function description
6. Special Comments
-2-

Other foc.us Security Sensor manuals

foc.us 64 RF User manual

foc.us

foc.us 64 RF User manual

foc.us ABH-50L User manual

foc.us

foc.us ABH-50L User manual

foc.us HMI Basic User manual

foc.us

foc.us HMI Basic User manual

foc.us MC-735 User manual

foc.us

foc.us MC-735 User manual

foc.us MC-760R User manual

foc.us

foc.us MC-760R User manual

foc.us ABH-50L User manual

foc.us

foc.us ABH-50L User manual

Popular Security Sensor manuals by other brands

jablotron JA-120PW quick start guide

jablotron

jablotron JA-120PW quick start guide

B.E.G. 93386 quick start guide

B.E.G.

B.E.G. 93386 quick start guide

Interlogix SB Series installation manual

Interlogix

Interlogix SB Series installation manual

RKI 35-3010A-12 manual

RKI

RKI 35-3010A-12 manual

Elko iNELS RFMD-100 manual

Elko

Elko iNELS RFMD-100 manual

Zeiss 4QBSD instruction manual

Zeiss

Zeiss 4QBSD instruction manual

Bosch DS935 VdS installation instructions

Bosch

Bosch DS935 VdS installation instructions

theben HTC thePrema P360-101 UP WH user guide

theben HTC

theben HTC thePrema P360-101 UP WH user guide

STEINEL professional HPD2 KNX quick start guide

STEINEL

STEINEL professional HPD2 KNX quick start guide

IFM PN701 Series operating instructions

IFM

IFM PN701 Series operating instructions

Elk Products ELK-319PIRW quick start guide

Elk Products

Elk Products ELK-319PIRW quick start guide

Climax EIR-32 manual

Climax

Climax EIR-32 manual

Bircher TopScan G3 Translation of the original instructions

Bircher

Bircher TopScan G3 Translation of the original instructions

REV Ritter LED GIGA SENSOR Assembly and operating instructions

REV Ritter

REV Ritter LED GIGA SENSOR Assembly and operating instructions

Chamberlain 772E installation manual

Chamberlain

Chamberlain 772E installation manual

Petzl I'D S manual

Petzl

Petzl I'D S manual

DINUY DM KNT 002 quick start guide

DINUY

DINUY DM KNT 002 quick start guide

INIM Vega V200 Installation

INIM

INIM Vega V200 Installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.