Models:
MC-735/735DMF/735DMT
MC-760/760DMF/760DMT
Detection Range 12m (MC-735)
15m (MC-760)
Input Voltage 9-16VDC
Current Drain about 15mA/12VDC
PIR section:
Optical lens data
PIR area: 22+12+6+4(MC-735)
44+12+6+4(MC-760)
Max coverage:12m*12m(MC-735)
15m*15m(MC-760)
Trigger indication: indicator twinkling
for about 10 sec.
Alarm and tamper
Alarm output: solid state relay,
NO 50mA/30V
The circuit will be open when alarm.
Alarm indication: LED on.
Event counter:optional,1-2 moving event.
Tamper interface: NO,50mA/30VDC
2.Specifications
Mounting
Surface or corner,at the height of 1.8 to 2.4 m
Note: Base allows single-sided corner mount at 45 to wall
Accessories:
BR-1:Surface mounted swivel bracket, adjustable 30
down and 45 left or right.
BR-2:BR-1 with a corner adapter
BR-3:BR-1 with a ceiling adapter
Environment:
Operating Temperature: -10 C to 50 C(14 F to 122 F )
Storage Temperature :-20 C to 60 C (-4 F to 40 F)
Anti whitelight: 9000 LUX
Physical
Size(H*W*D):112*59*41 m m
This device is coherent to Europe parliament direct 1999/5/EC
necessary items and rules, and also coherent to the main spirits
of radio and telecom terminal equipments on March 9 . 1999.
The device also reaches the Canadian standard RSS-210. It can
be used indoor and outdoor, which can reach its maximum prote-
ction and avoidance of above interference.
th
3.Installation
3.1 General Guidelines
Don't face cold or heat
source directly
Do not open window
of the saved area. Do not mount it
outdoor.
Don't face the
sun shine directly
Wire connection or
detector can't be near
to high-pressure cable
Don't install on a
unstable base.
The installation height of the detector
is 1.8-2.4 meters can Anti-pests
3.2Anti-pests installation
Never face the detector to the place that
pests can climb up directly
The upper part of the detection
area is non anti-pests area
1.Introduction
MC-735 is a digital micro-processing dual-tech detector adopting the technology
of DMF(digital memory focus ).DMT (dynamic matrixing time) .that can be
applying to decorative indoor with small size and flown line figure .The PIR parts
adopt column fresnel lens to effect of energy-receiving and four-layer screening
technology to anti blind-corner. Its advanced true motion recognition function .
anti-pets function can prevent wrong alarm to 15 kg pets or 5 cats .insects .mouse
or birds etc. It won’t trigger wrong alarm or miss alarm so it is far excellent in
function than common detectors. It can be used for different kind of indoor. With
the built-in large capability battery and exclusive circuitsave up powerl.
MC-735/760 intelligent with PIR
intrusion detector installation manual
WALK-
TEST
LED
LENS
PIR
SENSOR
LED
switch
SINGLE OR
DOUBLE
SELECTION
JUMPER
LED
Figure 1.General View Figure 2.Inside View
Suggestion angle
installation
B. Insert the wireline to
base through bacl slot
The detector will be in a visible area spy mode automatically after 3 minutes
of power connect. And adjust JUMPER to choosethe PIR function testing soley
or simultaneously.
Step-check LED lighting
Normal working state (LED on)
3.3Illustrated Installation Procedure
3.3.1 Disassemble unit
3.3.2 Mount base
1.8-2.4m 6-8ft above ground
Singleside45
angled side
Surface
mount
(1 of 2)
A. Mark the drilling points
and drilling the wall
C. Insert two dowels and
attach the base to the wall
with two screws
D.Insert the bottom edge of
the large PCB under this
TAB & Press the top edge in
3.10 Perform motion test to the detection area: install the cover and close the fasten part
(refer to the right diagram)
1. Start the test at least 2 minutes after power supply
2. Crossing to any direction of the detection area, your walking with 0.75m/s will cause the LED
indicator to light for 2-3 seconds (refer to the right diagram)
3 .Perform motion test from contrary directions in order to confirm the boundary of two sides. Make
confirmed that detection center pointing to the center of protected area.
4. Away from the detector 3 to 6 m, raise slowly your arm and reach into the detection zone, mark the
lower limit of PIR detection. Do the same step to confirm the upper limit.
5.the center of detection zone should not uphill incline. To obtain a good detection range , please adjust
the vertical detection range, en-sure the detector is in a correct position.
6. After MW sensitivity or detection angle are adjusted, walking test
must be performed according to the above steps.
Even the most sophisticated detcetors can sometimes be defeated or may fail to warn due to :DC power failure/improper connection, malicious mask-
ing of the lens,tampering with the optical system, decreased sensitivity in ambient temperatures near that of the human body and unexpected fail-
ure of a component part.The above list includes the most common reasons for failure recommended that the detector and the entire alarm system be ch-
ecked weekly, to ensure proper performance.An alarm system should not be regarded as a substitute for insurance. Home & property owners or renters sh-
ouldbe prudent enough to continue insuring their lives & property, even though they are protected by an alarm system.
WARNING! Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user s authority to operate the equipment.
This device has been tested and found to comply with the limits for a Class B digitaldevice, pursuant harmful interference in residential installations .This equipment
generates,uses and can radiate radio frequency energy and ,if not installed and used in accordance with the ins-tructions ,may cause harmful in-terference to radio and t-
elevision reception. However, there is no guarantee that interference will not occur in aparticular installation .If this device does cause such interference , which can be ver-
fied by turning the device off and on ,the user is encouraged to eliminate the interference by one or more of the followingmeasures:
- Increase the distance between the device and the receiver.
- Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
- Consult the dealer or an expericnced radio/TV technician.
4.Special comments
Loose the screw
6Wire up the terminal block

This manual suits for next models

1

Other foc.us Security Sensor manuals

foc.us MC-760R User manual

foc.us

foc.us MC-760R User manual

foc.us 64 RF User manual

foc.us

foc.us 64 RF User manual

foc.us ABH-50L User manual

foc.us

foc.us ABH-50L User manual

foc.us ABH-50L User manual

foc.us

foc.us ABH-50L User manual

foc.us MC-7380R User manual

foc.us

foc.us MC-7380R User manual

foc.us HMI Basic User manual

foc.us

foc.us HMI Basic User manual

Popular Security Sensor manuals by other brands

jablotron JA-120PW quick start guide

jablotron

jablotron JA-120PW quick start guide

B.E.G. 93386 quick start guide

B.E.G.

B.E.G. 93386 quick start guide

Interlogix SB Series installation manual

Interlogix

Interlogix SB Series installation manual

RKI 35-3010A-12 manual

RKI

RKI 35-3010A-12 manual

Elko iNELS RFMD-100 manual

Elko

Elko iNELS RFMD-100 manual

Zeiss 4QBSD instruction manual

Zeiss

Zeiss 4QBSD instruction manual

Bosch DS935 VdS installation instructions

Bosch

Bosch DS935 VdS installation instructions

theben HTC thePrema P360-101 UP WH user guide

theben HTC

theben HTC thePrema P360-101 UP WH user guide

STEINEL professional HPD2 KNX quick start guide

STEINEL

STEINEL professional HPD2 KNX quick start guide

IFM PN701 Series operating instructions

IFM

IFM PN701 Series operating instructions

Elk Products ELK-319PIRW quick start guide

Elk Products

Elk Products ELK-319PIRW quick start guide

Climax EIR-32 manual

Climax

Climax EIR-32 manual

Bircher TopScan G3 Translation of the original instructions

Bircher

Bircher TopScan G3 Translation of the original instructions

REV Ritter LED GIGA SENSOR Assembly and operating instructions

REV Ritter

REV Ritter LED GIGA SENSOR Assembly and operating instructions

Chamberlain 772E installation manual

Chamberlain

Chamberlain 772E installation manual

Petzl I'D S manual

Petzl

Petzl I'D S manual

DINUY DM KNT 002 quick start guide

DINUY

DINUY DM KNT 002 quick start guide

INIM Vega V200 Installation

INIM

INIM Vega V200 Installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.