Franklin Electric INLINE FLOW User manual

Owner's Manual
INLINE FLOW

BEFORE GETTING STARTED
Read and follow safety instructions. Refer to product data plate(s) for additional operating instructions and specifications. This device is an
independently-mounted operating control for use with water pumps that conform to the ratings listed in the specification table and comply
with type 1.C action.
This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and
be alert to the potential for personal injury:
DANGER warns about hazards that will cause serious personal injury, death, or major property damage if ignored.
WARNING warns about hazards that can cause serious personal injury, death, or major property damage if ignored.
CAUTION warns about hazards that will or can cause minor personal injury or major property damage if ignored.
NOTICE indicates special instructions which are important, but not related to hazards. Carefully read and follow all safety
instructions in this manual and on pump.
WARNING
RISK OF ELECTRIC SHOCK - This product is supplied with a grounding terminals. To reduce the risk of electrical shock, be certain that
incoming power and pump ground conductors are connected to the proper grounding terminals. Disconnect power before working
on or around the product.
This equipment should be installed by technically qualified personnel. Failure to install it in compliance with national and local electrical
and plumbing codes and within Franklin Electric recommendations may result in electrical shock or fire hazard, unsatisfactory performance,
or equipment failure. Installation information is available through pump manufacturers and distributors, or directly from Franklin Electric
at our toll-free number 1-800-701-7894.
This equipment must not be used by children or persons with reduced physical, sensory or mental abilities, or lacking in experience
and expertise, unless supervised or instructed. Children may not use the equipment, nor may they play with the equipment or in the
immediate vicinity.
If the power cord is damaged, it must only be replaced by qualified personnel.
CAUTION
• Keep work area clean, well-lit, and uncluttered.
• Keep safety labels clean and in good condition.
• Wear safety glasses while installing or performing maintenance on pump.
• Do not run pump dry. Fill pump with water before starting or pump will be damaged.
• Make sure all ELECTRICAL POWER IS OFF before connecting any electrical wires. Follow all device wiring instructions provided in the
“Installation: Electrical Wiring” section of this manual.
WARNING WARNING

3
TABLE OF CONTENTS
Before Getting Started.................................................................................2
Getting Started.......................................................................................4
Description ..........................................................................................4
Dimensions..........................................................................................4
Specifications ........................................................................................5
Installation: Pump Location ............................................................................5
Installation: Electrical Wiring ...........................................................................6
Operation ...........................................................................................8
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Troubleshooting ......................................................................................9
Standard Limited Warranty............................................................................ 12

4
IN FROM MAIN WATER SUPPLY
OUT TO SYSTEM
FLOW
FLOW
P1 P2
P1+P2
Figure 1 Incoming Main Pressure (e.g. City Main)
FLOW
FLOW
MIN. 8" (20 cm)
Figure 2 Gravity Flow System (e.g. Cistern)
WARNING
WARNING
DIMENSIONS
GETTING STARTED
This owner's manual provides you with the information required
to safely own and operate your flow control switch. Retain these
instructions for future reference.
This flow control switch is of the highest quality workmanship and
material. It has been engineered to give you long and reliable service.
Our products are carefully tested, inspected, and packaged, ensuring
safe delivery and operation.
Inspect Your Shipment
Please examine your product carefully to ensure that no damage
occurred during shipment. If damage is evident, please contact the
place of purchase or report this immediately to your shipping carrier.
They will assist you in replacement or repair, if required. In the case
of shipping damage, the carrier is fully responsible for the product's
safe arrival. Any claim for damage to the shipment, either visible or
concealed, must be made through the shipping carrier.
Package Includes:
• Pump control device
• Booster pump (in certain models)
• Installation manual
DANGER Do not use to pump flammable or explosive
fluids such as gasoline, fuel, oil, kerosene, etc. Do not use in explosive
atmospheres. Pump should only be used with liquids compatible with
pump component materials.
Hazardous Pressure
Booster pumps can produce significant
water pressure within a plumbing system.
This could cause damage to pipes and/or
fixtures. To prevent personal or property
damage, install a pressure relief valve
capable of conveying the entire water
volume to a drain. Relieve system pressure
before disassembling the device.
DESCRIPTION
This device activates your pump as water is used in the building.
Once the flow stops, the pump turns o. This will protect your pump
in case of a water shortage or dry run event. This product uses either
115 volts or 230 volts and can be installed on any surface-mounted
pump. When using this device, a pressure tank is not required, but
can be used as an optional accessory.
140.5 mm (5.5")
72.75 mm (2.9")
54 mm (2.1")
52.5 mm (2.1")
130 mm (5.1")

5
INSTALLATION: PUMP LOCATION
NOTICE Read and follow all instructions.
WARNING Liquid-tight cables or flexible conduit
and fittings must be used to maintain Type 4 rating.
Installation Procedure: Pump
Choose a clean, well-ventilated location that provides protection from
freezing, flooding, and excessive heat. Provide access for service and
draining of the device and pump.
The device can be installed directly on the pump discharge or
between the pump discharge and first water outlet. For proper
operation, Inline Controls must be installed vertically, as indicated by
the text on the product labeling of the control unit. Ensure the flow
direction arrow is facing upwards (Figure 3).
Auxillary Pressurized Bladder Tank Air Charge Setting:
Generally an auxillary pressurized bladder tank is not required, but
specific application driven conditions can facilitate the need for one.
For example, consider a system where the water flow starts/stops on
short intervals. If the system requires the motor to start beyond the
manufacturer's recommended number of starts per day, a bladder
tank can provide additional water supply, lengthening the total time
between motor starts (for Franklin Electric 4" Submersible Motors
see Table 1). For non-submerged, centrifugal pump/motors, regular
starts more frequent than 10 per minute would benefit from utilizing
a bladder tank.
Installation Consideration for 2-Wire 4" Submersible Biac Start Motors:
It may be necessary to use a small bladder tank with Biac
Start Submersible motors. The tank should be sized to provide
approximately 5 seconds of pressurized water allowing the biac switch
to cool and reset prior to the next pump start.
Description Inline Flow Control Switch
Name (on label) InlineFLW
Enclosure Rating NEMA Type 4
Max. Motor Size
and Voltage
0.75 hp 0.55 kW 115 V
1.5 hp 1.1 kW 230 V
Max. Current 15 A
Min. Flow 0.13 gpm
Electrical Connection FNPT 1/2"
Plumbing Connection MNPT 1"
Max. Operating Pressure 232 psi (16 bar)
Max. Operating Temperature 131 °F (55 °C)
Acceptable Voltage Fluctuation ±10%
Frequency 60 Hz
Male Connectors NPT 1"
Protection of Internal Components Pollution Degree 2
Impulse Voltage 2.5 kV
Nominal Fluid Temperature 68 °F (20 °C)
SPECIFICATIONS
Vertical Installation Only
Figure 3 Figure 4 Figure 5
Pump Location
NO
Table 1
MOTOR RATING MAXIMUM STARTS
PER 24 HR PERIOD
HP KW SINGLE PHASE THREE PHASE
Up to 0.75 Up to 0.55 300 300
1 through 5.5 0.75 through 4 100 300
7.5 through 30 5.5 through 22 50 100
40 and over 30 and over - 100

6
INSTALLATION: ELECTRICAL WIRING
WARNING Hazardous voltage can shock, burn, or
cause death.
CAUTION Improper wiring can result in permanent
damage to the system. Pump connection must comply with National
Electric Code (NEC) or Canadian Electric Code (CEC)
and all applicable local codes.
WARNING If you are not sure of the proper
electrical connections, employ a competent electrician for the
installation. This ensures the installation complies with all noted
electrical codes.
Disconnect power at electrical panel before making any electrical
connections. Supply voltage must be +/- 10% of device nameplate
voltage.
Low or high voltage can damage the device and will void the
warranty. Connect device to dedicated branch circuit with no other
appliances on it.
A fused disconnect switch or circuit breaker should be placed at
or near the pump as required by local electrical codes.
NOTICE Before installing the device, carefully check
the technical features and make sure they comply with those of the
pump and the system. The control label displays maximum pump HP.
Confirm compatibility between this device and the chosen pump.
NOTICE Follow all indications on the electrical
diagram shown in Figure 9.
WARNING Serious or fatal electrical shock may
result from failure to connect the pump and control to the service
entrance ground. Also ground metal plumbing and all other metal
near the device. When grounding these components, use a wire no
smaller than the power supply wires from the circuit breaker to the
device. To reduce the risk of electric shock, disconnect power before
working on or around the water system.
Installation Procedure: Wiring
1. Disconnect electrical power at the main breaker.
2. Confirm the voltage rating matches the pump/motor's voltage
rating and that the device's hp/kW rating is equal to or greater
than that of the pump/motor.
3. Verify that the dedicated branch circuit for the device is
equipped with a proper listed fuse/listed circuit breaker.
4. Remove the cover of the device by removing the screws as
shown in Figure 6. Cover features and label may vary based
on your model.
5. If mounting in wet environments, liquid-tight cables (Figure 7)
or flexible conduit fitting (Figure 8) are required (not supplied)
to ensure that the enclosure maintains a watertight Type 4
rating. Install the liquid-tight cables or flexible conduit fitting
into the conduit nuts in front of the power supply and motor
connectors (Figures 7 and 8).
WARNING Liquid-tight cables or flexible
conduit and fittings must be used to maintain Type 4 rating
(Figures 7 and 8). If you use water-resistant cables to run
electrical wire to the pump (Figure 7), tighten the supplied
cable/conduit connector to torque of 106 in-lbs (13 Nm).
If you use flexible conduit fittings to run electrical wire to the
pump (Figure 8), tighten the supplied cable/conduit connector to
a torque of 106 in-lbs (13 Nm), compressing the O-ring against
the outside housing of the flow control.
Cover Screws
Figure 6

7
NOTICE Install the cable/conduit connector with
the arrow pointing towards the flow control, as shown
in the figures.
6. Route supply wires through the flexible conduit fitting into the
wiring chamber of the flow control.
7. Connect the supply ground wires to the ground lug in the
wiring compartment.
NOTICE The safety earth ground connection is
marked at its terminal using the symbol (Figure 9).
8. Connect the supply wires to the screw terminal marked
L and N (Figure 9). Use only copper wires rated for at
least 60 °C. Lead wire terminals should be tightened
to a torque of 4 in-lbs (0.5 Nm).
9. Connect the motor wires to the screw terminal marked
U and V (Figure 9). Use only copper wires rated for at
least 60 °C. Lead wire terminals should be tightened
to a torque of 4 in-lbs (0.5 Nm).
10. Replace the cover and tighten the screws. For proper sealing,
the screws should be tightened to a torque of 13 in-lbs (1.5 Nm).
11. Once the cover has been replaced, ensure that the pump has
been correctly primed and reconnect the main breaker.
To Controller To 1/2" NPT
FOLLOW ARROW DIRECTION
Figure 7
Wiring for Liquid-tight Cables
To Controller Lead Input
FOLLOW ARROW DIRECTION
Figure 8
Wiring for Flexible Conduit
NOTE: The components marked out with an X in Figures 7 and 8
are not used for that specific installation.
N/L2
115 VAC 50-60 Hz
230 VAC 50-60 Hz
L1
115 VAC 50-60 Hz
230 VAC 50-60 Hz
Figure 9
Electrical DiagramVoltage Rating Table
On the product label, verify the voltage rating for the device and do
not exceed that voltage rating.
Supply Voltage Motor Voltage Motor Power kW Electrical
Diagram
Single-phase 115 V Single-phase 115 V Not more than 0.55 See Figure 9
Single-phase 230 V Single-phase 230 V Not more than 1.1 See Figure 9

8
OPERATION
Control Panel
Green LED on Power On Device energized
Yellow LED on Pump On Pump running
Button Restart Reset after failure
Startup
Once the power is turned back on to the device, the green “Power On”
LED should be illuminated.
1. Open a service point or tap in the system.
2. The pump should start and the yellow “Pump On” LED
should be illuminated.
3. The pump will run for several seconds to start the system.
You should begin to see water flowing from the faucet.
a. If more time is needed to see water flowing from the
faucet, press and hold the “Restart” button until water
flows from the faucet.
4. Close the service point and the pump will shut o in a few
seconds. The yellow “Pump On” LED should now be o. If the
pump does not shut o, refer to the Troubleshooting section.
5. Your device is ready to control your pump every time you use
water in the building.
Hazardous Pressure
Booster pumps can produce significant water
pressure within a plumbing system. This
could cause damage to pipes and/or fixtures.
To prevent personal or property damage,
install a pressure relief valve capable of
conveying the entire water volume to a
drain. Maximum system working pressure
is not to exceed 174 psi (400 ft of head).
Anti Pump-Lockup Start
If for any reason the pump remains idle for 24 consecutive hours,
the device will carry out an autorun feature to keep the system free
of debris and clogs. The pump/motor will run for approximately
5 seconds during this test.
MAINTENANCE
This device is maintenance-free. In case of system maintenance,
review and understand the following safety warnings and product
instructions prior to performing any service.
Hazardous voltage.
Can shock, burn, or cause death.
Ground the device before connecting to
power supply. Disconnect power before
working on the device, pump, or motor.
Hazardous pressure.
Relieve system pressure before
disassembling the device.
WARNING Before disconnecting the
pump, be sure the fuse box leads are disconnected or the
power is turned o. After reassembling the pump, refer to
these instructions before running.
WARNING Hazardous voltage can shock, burn,
or cause death. Disconnect power to pump before servicing unit.
Draining
NOTICE Disconnecting the pump will not necessarily
drain all other parts of the piping system. If there are
any concerns with the proper procedure or necessity of draining
the suction plumbing, contact a water systems professional.
All piping and water tanks exposed to freezing weather should be
drained. If there are any concerns with the proper procedure to
drain the system’s pressure tank, contact the tank manufacturer
for assistance.
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING

9
TROUBLESHOOTING
If the device and pump do not seem to be operating correctly
together by starting and stopping with water usage, first check
that the technical features of the flow controller and the pump
are compatible. Use the table and figures in this manual to
confirm compatibility.
For the flow control to properly operate the pump system, water
must pass through the device every time water is needed. The water
supply to the device and pump system is typically from a municipal
or utility water main line. The device can also operate on a cistern or
other non-pressurized water tank, but this should be located above
both the pump and the highest water outlet to ensure water flow
through the system.
Troubleshooting
Problem Probable Causes Corrective Action
Pump fails to start or restart
Bad electrical connection. Check the electrical connections.
Tripped electrical circuit breaker/fuse. Check electrical circuit breaker panel.
Pump obstructed. Check pump and suction line for debris.
No water flow. Check plumbing and water supply.
Control unit not installed vertically in proper orientation. Correct installation so that the control device is vertical, with all writing on
the product label in the proper upright position.
Pump works intermittently Minimum flow of 0.15 gpm not sustained. Increase water use.
Plumbing or check valve leak Repair or replace faulty plumbing/check valve
Pump will not shut o
System flow continues above 0.15 gpm.
Confirm that there is no water demand.
Check plumbing system for leak.
Device contains debris preventing switch closure. Clear debris from unit or plumbing.
Control unit not installed vertically in proper orientation. Correct installation so that the control device is vertical, with all writing on
the product label in the proper upright position.
Plumbing or check valve leak Repair or replace faulty plumbing/check valve

10
NOTES

11
NOTES

9255 Coverdale Road, Fort Wayne, IN 46809
Tel: 260.824.2900 Fax: 260.824.2909
www.franklinwater.com
STANDARD LIMITED WARRANTY
Except as set forth in an Extended Warranty, for twelve (12) months from the date of installation, but in no event more than twenty-four (24) months from the date of manufacture,
Franklin hereby warrants to the purchaser (“Purchaser”) of Franklin’s products that, for the applicable warranty period, the products purchased will (i) be free from defects in
workmanship and material at the time of shipment, (ii) perform consistently with samples previously supplied and (iii) conform to the specifications published or agreed to in
writing between the purchaser and Franklin. This limited warranty extends only to products purchased directly from Franklin. If a product is purchased other than from a distributor
or directly from Franklin, such product must be installed by a Franklin Certified Installer for this limited warranty to apply. This limited warranty is not assignable or transferable to
any subsequent purchaser or user.
a. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, STATUTORY, EXPRESS, OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. PURCHASER’S SOLE AND EXCLUSIVE REMEDY FOR FRANKLIN’S BREACH OF ITS OBLIGATIONS HEREUNDER, INCLUDING BREACH OF ANY EXPRESS OR IMPLIED
WARRANTY OR OTHERWISE, UNLESS PROVIDED ON THE FACE HEREOF OR IN A WRITTEN INSTRUMENT MADE PART OF THIS LIMITED WARRANTY, SHALL BE FOR THE PURCHASE PRICE
PAID TO FRANKLIN FOR THE NONCONFORMING OR DEFECTIVE PRODUCT OR FOR THE REPAIR OR REPLACEMENT OF NONCONFORMING OR DEFECTIVE PRODUCT, AT FRANKLIN’S ELECTION.
ANY FRANKLIN PRODUCT WHICH FRANKLIN DETERMINES TO BE DEFECTIVE WITHIN THE WARRANTY PERIOD SHALL BE, AT FRANKLIN’S SOLE OPTION, REPAIRED, REPLACED, OR A REFUND
OF THE PURCHASE PRICE PAID. Some states do not allow limitations on how long an implied warranty lasts, therefore, the limitations and exclusions relating to the products
may not apply.
b. WITHOUT LIMITING THE GENERALITY OF THE EXCLUSIONS OF THIS LIMITED WARRANTY, FRANKLIN SHALL NOT BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY FOR ANY AND
ALL (i) INCIDENTAL EXPENSES OR OTHER CHARGES, COSTS, EXPENSES (INCLUDING COSTS OF INSPECTION, TESTING, STORAGE, OR TRANSPORTATION) OR (ii) DAMAGES, INCLUDING
CONSEQUENTIAL, SPECIAL DAMAGES, PUNITIVE OR INDIRECT DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS, LOST TIME AND LOST BUSINESS OPPORTUNITIES, REGARDLESS
OF WHETHER FRANKLIN IS OR IS SHOWN TO BE AT FAULT, AND REGARDLESS OF WHETHER THERE IS OR THERE IS SHOWN TO HAVE BEEN A DEFECT IN MATERIALS OR WORKMANSHIP,
NEGLIGENCE IN MANUFACTURE OR DESIGN, OR A FAILURE TO WARN.
c. Franklin’s liability arising out of the sale or delivery of its products, or their use, whether based upon warranty contract, negligence, or otherwise, shall not in any case exceed the
cost of repair or replacement of the product and, upon expiration of any applicable warranty period, any and all such liability shall terminate.
d. Without limiting the generality of the exclusions of this limited warranty, Franklin does not warrant the adequacy of any specifications provided directly or indirectly by a
purchaser or that Franklin’s products will perform in accordance with such specifications. This limited warranty does not apply to any products that have been subject to misuse
(including use in a manner inconsistent with the design of the product), abuse, neglect, accident or improper installation or maintenance, or to products that have been altered or
repaired by any person or entity other than Franklin or its authorized representatives.
e. Unless otherwise specified in an Extended Warranty authorized by Franklin for a specific product or product line, this limited warranty does not apply to performance caused by
abrasive materials, corrosion due to aggressive conditions or improper voltage supply.
f. With respect to motors and pumps, the following conditions automatically void this limited warranty:
1. Mud or sand deposits which indicate that the motor has been submerged in mud or sand.
2. Physical damage as evidenced by bent shaft, broken or chipped castings, or broken or bent thrust parts.
3. Sand damage as indicated by abrasive wear of motor seals or splines.
4. Lightning damage (often referred to as high voltage surge damage).
5. Electrical failures due to the use of non-approved overload protection.
6. Unauthorized disassembly.
Form 998075002
Rev. 001
10/18

Manuel d’utilisation
CONTRÔLE DE
DÉBIT EN LIGNE

AVANT DE COMMENCER
Consultez et respectez toutes les directives de sécurité. Consultez les plaques signalétiques du produit pour obtenir des directives d’utilisation et des
spécifications additionnelles. Cet appareil est une commande de fonctionnement montée de manière indépendante, pour une utilisation avec des
pompes d’eau conformes aux valeurs nominales indiquées dans la table de spécifications et à une action de type1.C.
Voici le symbole d’alerte de sécurité. Si vous voyez ce symbole sur votre pompe ou dans ce manuel, recherchez un des mots de
signalement suivants et faites attention aux blessures potentielles:
DANGER informe des dangers qui entraîneront des blessures graves, la mort, ou des dommages matériels importants s’il est
ignoré.
AVERTISSEMENT informe des dangers qui risquent d’entraîner des blessures graves, la mort, ou des dommages
matériels importants s’il est ignoré.
ATTENTION signale des dangers qui entraîneront ou risquent d’entraîner des blessures mineures ou des dommages
matériels importants s’il est ignoré.
REMARQUE indique des instructions spéciales importantes, mais qui ne sont cependant pas liées à des dangers.
Consultez et respectez attentivement toutes les directives de sécurité qui figurent dans ce manuel et sur la pompe.
AVERTISSEMENT
RISQUE DE DÉCHARGE ÉLECTRIQUE– Ce produit est livré avec des bornes de mise à la terre. Afin de réduire le risque de décharge électrique,
s’assurer que l’alimentation entrante et les conducteurs de mise à la terre de la pompe sont branchés aux bornes de mise à la terre appropriées.
Coupez l’alimentation avant de commencer le travail sur le produit ou à proximité de celui-ci.
Cet équipement doit être installé par une personne qualifiée sur le plan technique. Une installation qui ne respecte pas les codes nationaux
et locaux de l’électricité et de la plomberie, ainsi que les recommandations de FranklinElectric est susceptible de provoquer une décharge
électrique, un incendie, un rendement insatisfaisant ou une défaillance de l’équipement. De l’information sur l’installation est disponible auprès
des fabricants et des distributeurs de pompes, ou directement auprès de FranklinElectric au moyen de notre numéro sans frais, 1-800-701-7894.
Cet équipement ne doit pas être utilisé par des enfants ou des personnes dont les capacités physiques, sensorielles ou mentales sont réduites,
ou ne possédant pas l’expérience ou l’expertise requise, sauf s’ils sont supervisés ou dirigés. Les enfants ne doivent pas utiliser l’équipement ni
jouer avec celui-ci ou à proximité de ce dernier.
Si le cordon d’alimentation est endommagé, il doit être remplacé uniquement par une personne compétente.
ATTENTION
• L’aire de travail doit être propre, bien éclairée et dégagée.
• Maintenez les étiquettes de sécurité propres et en bon état.
• Portez des lunettes de protection pendant les travaux d’installation ou de maintenance de la pompe.
• La pompe ne doit pas fonctionner à vide. Remplissez la pompe d’eau avant le démarrage afin de ne pas l’endommager.
• Assurez-vous que toute L’ALIMENTATION ÉLECTRIQUE EST COUPÉE avant de brancher des fils électriques. Respectez toutes les directives
de câblage du dispositif qui sont énoncées dans la section «Installation: câblage électrique» de ce manuel.
DANGER AVERTISSEMENT

3
TABLE DES MATIÈRES
Avant de commencer..................................................................................2
Pour commencer .....................................................................................4
Description ..........................................................................................4
Dimensions..........................................................................................4
Spécifications ........................................................................................5
Installation: Emplacement de la pompe .................................................................5
Installation: Câblage électrique.........................................................................6
Utilisation ...........................................................................................8
Entretien ............................................................................................8
Dépannage ..........................................................................................9
Garantie limitée standard ............................................................................. 12

4
POUR COMMENCER
Ce manuel d’utilisation vous fournit l’information requise pour
utiliser de manière sécuritaire votre interrupteur de contrôle du débit.
Conservez ces directives pour référence ultérieure.
Cet interrupteur de contrôle du débit utilise des matériaux et provient
d’une main-d’œuvre de la plus haute qualité. Elle a été conçue
pour vous orir un service durable et fiable. Nos produits ont été
soigneusement testés, inspectés et emballés pour en assurer la
livraison et le fonctionnement sécuritaires.
Inspectez le matériel reçu
Veuillez examiner votre produit soigneusement afin de vous assurer
qu’aucun dommage ne s’est produit pendant l’expédition. À la
réception du dispositif, examinez-le attentivement afin de vous
assurer qu’il n’a pas été endommagé pendant l’expédition. Si des
dommages sont visibles, veuillez communiquer avec le vendeur
ou le signaler immédiatement à votre transporteur. Il vous aidera à
obtenir un remplacement ou une réparation, le cas échéant. En cas
de dommage durant l’expédition, le transporteur est pleinement
responsable de la livraison sécuritaire du produit. Toute réclamation
concernant des dommages visibles ou cachés doit être transmise au
transporteur.
L’emballage comprend:
• Dispositif de commande de pompe
• Pompe de surpression (dans certains modèles)
• Manuel d’installation
DANGER N’utilisez pas pour pomper des
fluides inflammables ou explosifs, comme de l’essence, du mazout,
du kérosène,etc. Ne pas utiliser dans des atmosphères explosives.
La pompe ne doit être utilisée qu’avec des liquides qui sont
compatibles avec les matériaux des composants de la pompe.
Pression dangereuse
Les pompes de surpression peuvent
produire une pression d’eau importante
dans un système de plomberie. Cela peut
endommager les tuyaux ou les appareils.
Pour prévenir les blessures et les dommages
matériels, installer une soupape de sûreté qui peut prendre en charge
le volume d’eau complet vers un drain. Laissez s’échapper la pression
du système avant de désassembler l’appareil.
DESCRIPTION
Ce dispositif active votre pompe lorsqu’on utilise de l’eau dans
l’immeuble. Lorsque le débit cesse, la pompe s’arrête. Cela protège
votre pompe en cas de pénurie d’eau ou de fonctionnement à vide. Ce
produit utilise 115V ou 230V et peut être installé sur n’importe quelle
pompe de surface. Vous pouvez installer un réservoir pressurisé en
tant qu’accessoire facultatif à utiliser avec ce dispositif.
ENTRÉE À PARTIR DE L’ALIMENTATION
EN EAU PRINCIPALE
SORTIE VERS LE SYSTÈME
DÉBIT
DÉBIT
P1 P2
P1+P2
Figure1 Pression principale entrante (p.ex., réseau municipal)
DÉBIT
DÉBIT
MN. 8po (20 cm)
Figure2 Système de débit par gravité (p.ex., citerne)
DANGER
AVERTISSEMENT
DIMENSIONS 140.5 mm (5.5")
72.75 mm (2.9")
54 mm (2.1")
52.5 mm (2.1")
130 mm (5.1")

5
INSTALLATION:
EMPLACEMENT DE LA POMPE
REMARQUE Consultez et respectez toutes les
directives.
AVERTISSEMENT Des câbles étanches aux
liquides ou des raccords et des conduits flexibles doivent être utilisés
pour maintenir la catégorie de type4.
Procédure d’installation: Pompe
Optez pour un emplacement propre et bien aéré protégé du gel, des inondations et
des grandes chaleurs. Prévoyez l’accès pour l’entretien et la vidange du dispositif et
de la pompe.
Le dispositif peut être installé directement sur le refoulement de la pompe ou entre
le refoulement et la première sortie d’eau. Pour fonctionner de manière appropriée,
les dispositifs de contrôle en ligne doivent être installés à la verticale, comme
indiqué sur l’étiquette de l’unité de contrôle. Assurez-vous que la flèche de direction
du débit pointe vers le haut (figure3).
Réglage de la charge d'air du réservoir à vessie sous pression
auxiliaire:
En général, un réservoir à vessie pressurisé auxiliaire n'est pas requis, mais des
conditions spécifiques à l'application peuvent en faciliter l'utilisation. Par exemple,
considérons un système où le débit d'eau commence / s'arrête à intervalles
rapprochés. Si le système nécessite que le moteur démarre au-delà du nombre
de démarrages recommandé par jour par le fabricant, un réservoir à vessie peut
fournir une alimentation en eau supplémentaire, ce qui allonge le temps total entre
les démarrages (pour les moteurs submersibles Franklin Electric 4 " les pompes /
moteurs centrifuges immergés, les démarrages réguliers plus fréquents que 10 par
minute gagneraient à utiliser un réservoir à vessie.
Considération d'installation pour les moteurs bi-démarreurs Biac Start
à 2 fils:
Il peut être nécessaire d’utiliser un petit réservoir à vessie équipé de moteurs
submersibles Biac Start. Le réservoir doit être dimensionné pour fournir environ 5
secondes d’eau sous pression, ce qui permet à l’interrupteur biac de se refroidir et
de se réinitialiser avant le prochain démarrage de la pompe.
Description Interrupteur de contrôle
du débit en ligne
Nom (sur l’étiquette) InlineFLW
Type nominal NEMA du boîtier Type4
Tension et taille de moteur max. 0,75HP 0,55 kW 115V
1,5HP 1,1 kW 230 V
Intensité max. 15 A
Débit min. 0,13GPM
FNPT, connexion électrique 1/2po (12,7mm)
MNPT, connexion de plomberie 1po (25,4mm)
Pression de fonctionnement max. 232PSI (16bar)
Température de fonctionnement max. 131°F (55°C)
Variation de tension acceptable ±10%
Fréquence 60Hz
Connecteurs mâles NPT 1po (25,4mm)
Protection des composants internes Degré de pollution2
Tension d’impulsion 2,5 kV
Température nominale du fluide 68 °F (20 °C)
SPÉCIFICATIONS
Installation à la verticale seulement
Figure3 Figure4 Figure5
Emplacement de la pompe
NON
Tableau 1
SPÉCIFICATION MOTEUR MAXIMUM STARTS POUR UNE
PERIODE DE 24 HEURES
HP KW MONOPHASÉ TROIS PHASES
Jusqu'à 0.75 Jusqu'à 0.55 300 300
1 à 5.5 0.75 à 4 100 300
7.5 à 30 5.5 à 22 50 100
et plus de 40 et plus de 30 - 100

6
INSTALLATION: CÂBLAGE ÉLECTRIQUE
AVERTISSEMENT
Des tensions dangereuses peuvent provoquer une décharge
électrique, des brûlures ou la mort.
ATTENTION Un câblage inadéquat peut
provoquer des dommages permanents au système. Les branchements
de la pompe doivent satisfaire aux exigences du Code national de
l’électricité (NEC) ou du Code canadien de l’électricité (CCE), ainsi que
de tous les codes locaux applicables.
AVERTISSEMENT
Si vous avez des doutes sur les branchements, faites appel à un
électricien compétent pour procéder à l’installation. Vous garantirez
ainsi le respect de tous les codes de l’électricité en vigueur.
Coupez l’alimentation au panneau électrique avant d’eectuer
tout branchement électrique. La tension d’alimentation doit
correspondre à plus ou moins 10% à celle inscrite sur la plaque
signalétique de l’appareil.
Une tension trop faible ou trop élevée peut endommager
l’appareil et annulera la garantie. Brancher l’appareil à un circuit
de dérivation indépendant qui n’alimente aucun autre appareil.
Un sectionneur à fusibles ou un disjoncteur devrait être
situé sur la pompe ou à proximité, conformément aux codes
de l’électricité locaux.
REMARQUE
Avant d’installer l’appareil, vérifier soigneusement les caractéristiques
techniques et s’assurer qu’elles sont conformes à celles de la pompe
et du système. L’étiquette de commande indique la puissance
maximale (en HP) de la pompe. Confirmez la compatibilité
entre cet appareil et la pompe choisie.
REMARQUE
Suivez toutes les indications sur le schéma électrique de la figure9.
AVERTISSEMENT
Le fait de ne pas brancher la pompe et la commande au fil de mise à
la terre de l’entrée de service peut provoquer une décharge électrique
grave ou mortelle. Il faut également mettre à la terre la plomberie en
métal et tous les autres métaux à proximité de l’appareil. Pendant la
mise à la terre de ces composants, utiliser un câble dont le diamètre
n’est pas inférieur à celui des fils d’alimentation qui relient le
disjoncteur et l’appareil. Pour réduire le risque de décharge électrique,
débrancher l’alimentation avant de travailler sur le réseau d’eau ou à
proximité de celui-ci.
Procédure d’installation: Câblage
1. Coupez le courant du disjoncteur principal.
2. Confirmez que la tension nominale correspond à la tension
nominale de la pompe/du moteur et que la puissance
(en HP ou kW) du dispositif est égale ou supérieure à celle
de la pompe/du moteur.
3. Vérifiez que le circuit de dérivation indépendant du
dispositif est muni d’un fusible ou disjoncteur de taille
appropriée et homologué.
4. Retirez le couvercle du dispositif en retirant les vis, comme
illustré à la figure6. Les caractéristiques et l’étiquette du
couvercle peuvent varier selon votre modèle.
5. Dans le cas d’une installation dans un environnement humide,
des câbles étanches aux liquides (figure7) ou un raccord de
conduit flexible (figure8) sont requis (mais non fournis), pour
s’assurer que le boîtier maintient une étanchéité aux liquides de
type4. Installez les câbles étanches aux liquides ou le raccord
de conduit flexible dans les écrous du conduit en avant des
connecteurs d’alimentation et du moteur (figures7 et8).
AVERTISSEMENT Des câbles
étanches aux liquides ou des raccords et des conduits flexibles
doivent être utilisés pour maintenir la catégorie de type4
(figures7 et8). Si vous utilisez des câbles à l’épreuve de l’eau
pour acheminer le fil électrique à la pompe (figure7), serrez
le connecteur de conduit/câble fourni à un couple de 106po-lb
(13Nm).
Si vous utilisez un raccord de conduit flexible pour acheminer
le fil électrique à la pompe (figure8), serrez le connecteur
de conduit/câble fourni à un couple de 106po-lb (13Nm) en
compressant le joint torique contre le boîtier extérieur du
contrôle de débit.
Vis de couvercle
Figure6

7
REMARQUE Installez le connecteur
de conduit/câble avec la flèche pointant vers le contrôle de débit,
comme illustré dans les figures.
6. Acheminez les fils d’alimentation au travers du raccord de
conduit flexible et jusque dans la chambre de câblage du
contrôle de débit.
7. Branchez les fils de mise à la terre de l’alimentation à la
languette de mise à la terre dans le compartiment de câblage.
REMARQUE La connexion de
mise à la terre de sécurité est indiquée sur sa borne au moyen
du symbole (figure9).
8. Branchez les fils d’alimentation aux bornes à vis marquéesL etN
(figure9). Utilisez seulement des fils en cuivre conçus pour au
moins 60°C. Les bornes de fils de connexion doivent être serrées
à un couple de 4po-lb (0,5Nm).
9. Branchez les fils du moteur aux bornes à vis marquéesU etV
(figure9). Utilisez seulement des fils en cuivre conçus pour au
moins 60°C. Les bornes de fils de connexion doivent être serrées
à un couple de 4po-lb (0,5Nm).
10. Replacez le couvercle et serrez les vis. Pour une étanchéité
appropriée, les vis doivent être serrées à un couple
de 13po-lb (1,5Nm).
11. Une fois le couvercle remis en place, assurez-vous que
la pompe a été correctement amorcée, puis rebranchez
le disjoncteur principal.
Vers le
contrôleur Vers NPT 1/2po
(12,7mm)
SUIVRE LA DIRECTION DE LA FLÈCHE
Figure7
Câblage de câbles étanches aux liquides
Vers le
contrôleur Entrée de
connexion
SUIVRE LA DIRECTION DE LA FLÈCHE
Figure8
Câblage avec conduit flexible
REMARQUE Les composants marqués d’unX dans
les figures7 et8 ne sont pas utilisés pour cette installation particulière.
N/L2
115VCA 50 à 60Hz
230VCA 50 à 60Hz
L1
115VCA 50 à 60Hz
230VCA 50 à 60Hz
Figure9
Schéma électriqueTableau des tensions nominales
Sur l’étiquette du produit, vérifiez la tension nominale pour le
dispositif et ne la dépassez pas.
Tension
d’alimentation Tension du moteur Puissance du
moteur (kW) Schéma
électrique
Monophasé 115V Monophasé 115V Pas plus de 0,55 Voir la
figure9
Monophasé 230V Monophasé 230V Pas plus de 1,1 Voir la
figure9

8
FONCTIONNEMENT
Panneau de commande
Voyant à DEL
vert allumé En fonction Dispositif sous tension
Voyant à DEL
jaune allumé Pompe en fonction Pompe fonctionne
Bouton Redémarrage Réinitialisation après
une défaillance
Démarrage
Une fois l’alimentation de l’appareil rétablie, le voyant à DEL vert
«Power On» («Sous tension») devrait s’allumer.
1. Ouvrez un robinet ou un point de service dans le système.
2. La pompe devrait démarrer et le voyant à DEL jaune
«Pump On» («Pompe activée») devrait s’allumer.
3. La pompe fonctionnera pendant plusieurs secondes
pour démarrer le système. De l’eau devrait commencer
à s’écouler du robinet.
a. Si un délai plus long est nécessaire avant que de l’eau s’écoule
du robinet, appuyer et maintenir enfoncé le bouton «Restart»
(«Redémarrer») jusqu’à ce que de l’eau s’écoule du robinet.
4. Fermez le point de service; la pompe s’arrêtera après
quelques secondes. Le voyant à DEL jaune «Pump On»
(«Pompe activée») devrait s’éteindre. Si la pompe ne
s’arrête pas, consulter la section sur le dépannage.
5. L’appareil est maintenant prêt à commander la pompe toutes les
fois que de l’eau est utilisée dans l’immeuble.
Pression dangereuse
Les pompes de surpression peuvent
produire une pression d’eau importante
dans un système de plomberie. Cela peut
endommager les tuyaux ou les appareils.
Pour prévenir les blessures et les dommages
matériels, installer une soupape de sûreté qui peut prendre en charge
le volume d’eau complet vers un drain. La pression de fonctionnement
maximale du système ne doit pas dépasser 174PSI (400pi [122m] de
charge hydraulique).
Démarrage anti-verrouillage de pompe
Si, pour une quelconque raison, la pompe demeure inutilisée
pendant 24heures consécutives, le dispositif eectuera un
démarrage automatique pour garder le système exempt de débris
et d’obstructions. La pompe et le moteur fonctionneront pendant
environ cinq secondes durant ce test.
MAINTENANCE
Le dispositif n’a besoin d’aucune maintenance. En cas de
maintenance du système, revoyez et assurez-vous de comprendre les
avertissements de sécurité et les directives sur le produit qui suivent
avant d’eectuer tout entretien.
Voltage dangereux. Peut provoquer une
décharge, des brûlures ou la mort.
Mettez le dispositif à la terre avant de
brancher l’alimentation électrique.
Débranchez l’alimentation avant de travailler
sur le dispositif, la pompe ou le moteur.
Pression dangereuse.
Laissez s’échapper la pression du système
avant de désassembler l’appareil.
AVERTISSEMENT
Avant de déconnecter la pompe, assurez-vous que les fils de la
boîte à fusibles sont débranchés ou que l’alimentation est coupée.
Après avoir réassemblé la pompe, reportez-vous à ces directives
avant de la mettre en marche.
AVERTISSEMENT
Des tensions dangereuses peuvent provoquer une décharge
électrique, des brûlures ou la mort. Coupez le courant de la pompe
avant de procéder à l’entretien.
Vidange
REMARQUE Le fait de débrancher la pompe ne
vidangera pas nécessairement toutes les autres parties du système de
tuyauterie. Si vous avez des doutes concernant la procédure à suivre
ou la nécessité de vidanger la plomberie d’aspiration, faites appel à
un professionnel des réseaux d’eau.
Toute la tuyauterie et tous les réservoirs d’eau exposés au gel doivent
être vidangés. Si vous avez des doutes concernant la procédure à
suivre pour vidanger le réservoir pressurisé du système, contactez le
fabricant du réservoir pour obtenir de l'aide.
DANGER
AVERTISSEMENT
DANGER
AVERTISSEMENT
DANGER
AVERTISSEMENT
This manual suits for next models
1
Table of contents
Languages:
Popular Switch manuals by other brands

Meridian
Meridian hdmax 421 Specifications

enika
enika P8 T PSW quick start guide

Computronic
Computronic VPP404 Installation and user manual

Endress+Hauser
Endress+Hauser Nivotester FTL325N-1 1 manual

Precise Time and Frequency
Precise Time and Frequency ptf 1226 Operation and maintenance manual

PESA
PESA RCP-48X manual