Specifications
subject to change.
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-800-FRIGIDAIRE
•
frigidaire.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
frigidaire.ca
FGGF3030P 01/14 © 2014 Electrolux Home Products, Inc.
Freestanding Ranges
FGGF3030P F/ W/ B 30" Gas
30" Gas Freestanding Ranges
Gallery
Freestanding Range Specifications
• Product Shipping Weight (approx.) – 196 Lbs.
• Voltage Rating – 120V / 60 Hz / 15 Amps
• Connected Load (kW Rating) @ 120 Volts = TBD kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
• Amps @ 120 Volts = 15 Amps
• Always consult local and national electric and gas codes.
• Make sure wall coverings around range can withstand heat generated
by range.
• Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
• Do not obstruct flow of combustion air at oven vent nor around base
or beneath lower front panel of range. Range requires fresh air for
proper burner combustion.
• Do not install range beneath any downward-blowing, overhead vent
hood or air curtain.
• Range ships with 3/4" factory regulator.
• Range is LP Gas convertible. (Optional LP Gas Conversion
Kit available.)
• Floor beneath range MUST be solid and level.
• Overhead cabinetry should not exceed a 13" maximum depth.
• Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
• Range can be installed flush to wall with 0" minimum rear clearance.
• Minimum clearance required (from edge of rangetop to nearest
combustible wall on either side of range above 36" height) is based
on largest burner output rating on cooking surface.
• To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
• Follow all dimension requirements provided to prevent property
damage, potential fire hazard, and incorrect countertop and
cabinet cuts.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.