FS.COM ELPS Instruction sheet

ELPS Configuration Commands

Table of Contents
Table of Contents
Chapter 1 ELPS Configuration Commands ................................................................................................................... 1
1.1 Global Commands........................................................................................................................................ 1
1.1.1
eellppss
id
.............................................................................................................................................. 1
1.1.2
wwoorrkkiinngg--vvllaannmmaapp
vlanmap
................................................................................................................ 2
1.1.3
pprrootteeccttiioonn--mmooddee {{11pplluuss11--bbiiddiirreeccttiioonnaall
|
11pplluuss11--uunniiddiirreeccttiioonnaall
|
11ttoo11--bbiiddiirreeccttiioonnaall}}
........................ 2
1.1.4
rreevveerrttiivvee--mmooddee {{rreevveerrttiivvee
|
nnoonnrreevveerrttiivvee}}
........................................................................................... 4
1.1.5
ddeetteecctt--ffaauulltt {{pphhyyssiiccaall--ppoorrtt--cchheecckk
|
ccoonnttiinnuuiittyy--cchheecckk
|
bbootthh--cchheecckk}}
.................................................... 5
1.1.6 WWTTRR--ttiimmee ......................................................................................................................................... 6
1.1.7 hhoolldd--ooffff--ttiimmee .................................................................................................................................... 6
1.2 Port Configuration Commands...................................................................................................................... 7
1.2.1 eellppss
id
{{wwoorrkkiinngg--ttrraannssppoorrtt
|
prrotteecctiioonn--ttrraannssppoorrtt}} ............................................................................. 7
1.2.2 eellppss
id
mmeepp mmdd
md-string
mmaa
ma-string
lleevveell
level-id
llooccaall
local-id
rreemmoottee
remote-id
....................... 9
1.3 Control Commands .................................................................................................................................... 10
1.3.1 eellppss
id
LLoocckkOOuutt...............................................................................................................................10
1.3.2 eellppss
id
FFoorrcceeddSSwwiittcchh ...................................................................................................................... 11
1.3.3 eellppss
id
MMaannuuaallSSwwiittcchh ..................................................................................................................... 11
1.3.4 eellppss
id
MMaannuuaallSSwwiittcchh--WWoorrkkiinngg........................................................................................................ 12
1.3.5 eellppss
id
EExxeerrcciissee ..............................................................................................................................13
1.3.6 eellppss
id
CCLLEEAARR................................................................................................................................. 14
1.4 Show ......................................................................................................................................................... 15
1.4.1 sshhooww eellppss ....................................................................................................................................... 15
- I -

ELPS Configuration Commands
Chapter 1 ELPS Configuration Commands
1.1 Global Commands
1.1.1 elps id
To set an instance of ELPS node and enter the node mode, run the following
command:
elps id
To cancel an instance of ring, run the following command:
no elps id
Parameter
Parameter Description
id Stands for the node instance ID, which ranges from 0 to 7.
Default value
By default, the ELPS node instance is not configured.
Command mode
Global configuration mode
Explanation
N/A.
Example
S1_config#elps 1
S1_config_elps1#
Related command
N/A.
- 1 -

ELPS Configuration Commands
1.1.2 working-vlanmap vlanmap
To set the working vlan map of the ELPS node, run the following command:
working-vlanmap vlanmap
Parameter
Parameter Description
vlanmap Stands for the VLAN range table (1-4094), which is similar with
(1,3,5,7), (1,3-5,7) or (1-7).
Default value
By default, the working vlan map of a node is not configured.
Command mode
EPLS node configuration mode
Explanation
1. Configuring working VLAN does not mean creating this VLAN, so you have to
establish the control VLAN manually.
2. After working-vlanmap, protection-mode, revertive-mode and detect-fault are
configured, the ELPS configuration mode exits and the ELPS node is started, the
working-vlanmap cannot be modified.
Example
S1_config#elps 1
S1_config_elps1#working-vlanmap 1-10
S1_config_elps1#
Related command
protection-mode {1plus1-bidirectional | 1plus1-unidirectional | 1to1-bidirectional}
revertive-mode {revertive | nonrevertive}
detect-fault {physical-port-check| continuity-check | both-check}
1.1.3 protection-mode {1plus1-bidirectional | 1plus1-unidirectional |
1to1-bidirectional}
To set the protection mode of the ELPS node to be the 1plus1-bidirectional mode, run
the following command:
- 2 -

ELPS Configuration Commands
protection-mode 1plus1-bidirectional
To set the protection mode of the ELPS node to be the 1plus1-unidirectional mode, run
the following command:
protection-mode 1plus1-unidirectional
To set the protection mode of the ELPS node to be the 1to1-bidirectional mode, run the
following command:
protection-mode 1to1-bidirectional
Parameter
N/A.
Default value
By default, the ELPS node’s protection mode is not configured.
Command mode
ELPS node configuration mode
Explanation
1. When the ELPS node's protection mode is set to 1plus1-bidirectional or
1plus1-unidirectional, the revertive mode of node is non-revertive by default; the
protection mode is 1to1-bidirectional, it is revertive by default.
2. After working-vlanmap, protection-mode, revertive-mode and detect-fault are
configured, the ELPS configuration mode exits and the ELPS node is started, the
working-vlanmap cannot be modified.
Example
S1_config#elps 1
S1_config_elps1#working-vlanmap 1-10
S1_config_elps1#protection-mode 1plus1-bidirectional
S1_config_elps1#
Related command
working-vlanmap vlanmap
revertive-mode {revertive | nonrevertive}
detect-fault {physical-port-check| continuity-check | both-check}
- 3 -

ELPS Configuration Commands
1.1.4 revertive-mode {revertive | nonrevertive}
To set the mode of the ELPS to revertive, run the following command:
revertive-mode revertive
To set the mode of the ELPS to non-revertive, run the following command:
revertive-mode nonrevertive
Parameter
N/A.
Default value
By default, the ELPS node’s mode is not configured.
Command mode
ELPS node configuration mode
Explanation
1. When the ELPS node's protection mode is set to 1plus1-bidirectional or
1plus1-unidirectional, the revertive mode of node is non-revertive by default; the
protection mode is 1to1-bidirectional, it is revertive by default. The two cases change
after the configuration of the revertive mode.
2. After working-vlanmap, protection-mode, revertive-mode and detect-fault are
configured, the ELPS configuration mode exits and the ELPS node is started, the
working-vlanmap cannot be modified.
Example
S1_config#elps 1
S1_config_elps1#working-vlanmap 1-10
S1_config_elps1#protection-mode 1plus1-bidirectional
S1_config_elps1#revertive-mode revertive
S1_config_elps1#
Related command
working-vlanmap vlanmap
protection-mode {1plus1-bidirectional | 1plus1-unidirectional | 1to1-bidirectional}
detect-fault {physical-port-check| continuity-check | both-check}
- 4 -

ELPS Configuration Commands
1.1.5 detect-fault {physical-port-check| continuity-check | both-check}
To set the trouble monitoring mode of the ELPS node to physical-port-check, run the
following command:
detect-fault physical-port-check
To set the trouble monitoring mode of the ELPS node to continuity-check, run the
following command:
detect-fault continuity-check
To set the trouble monitoring mode of the ELPS node to both-check, run the following
command:
detect-fault both-check
Default value
By default, the ELPS node’s trouble monitoring mode is not configured.
Command mode
ELPS node configuration mode
Explanation
1. After working-vlanmap, protection-mode, revertive-mode and detect-fault are
configured, the ELPS configuration mode exits and the ELPS node is started, the
working-vlanmap cannot be modified.
Example
S1_config#elps 1
S1_config_elps1#working-vlanmap 1-10
S1_config_elps1#protection-mode 1plus1-bidirectional
S1_config_elps1#revertive-mode revertive
S1_config_elps1#detect-fault continuity-check
S1_config_elps1#
Related command
working-vlanmap vlanmap
protection-mode {1plus1-bidirectional | 1plus1-unidirectional | 1to1-bidirectional}
revertive-mode {revertive | nonrevertive}
- 5 -

ELPS Configuration Commands
1.1.6 WTR-time
To set the WTR time of the ELPS node, run the following command:
WTR-time value
To resume the default WTR time of the ELPS node, run the following command:
no WTR-time
Parameter
Parameter Description
value Stands for the WTR time, which ranges from 5 to 12 minutes. Its
step is 1 minute and its default value is 5 minutes.
Default value
By default, the WTR-time is 5 minutes.
Command mode
ELPS node configuration mode
Explanation
N/A.
Example
S1_config#elps 1
S1_config_elps1#working-vlanmap 1-10
S1_config_elps1#protection-mode 1plus1-bidirectional
S1_config_elps1#revertive-mode revertive
S1_config_elps1#detect-fault continuity-check
S1_config_elps1#WTR-time 6
S1_config_elps1#
Related command
N/A
1.1.7 hold-off-time
To set the hold-off time of the ELPS node, run the following command:
- 6 -

ELPS Configuration Commands
hold-off-time value
To resume the default hold-off time of the ELPS node, run the following command:
no hold-off-time
Parameter
Parameter Description
value Stands for the hold-off time, which ranges from 1 to 10 seconds.
Its step is 100ms and its default value is 1 second.
Default value
By default, the hold-off time is one second.
Command mode
ELPS node configuration mode
Explanation
N/A.
Example
S1_config#elps 1
S1_config_elps1#working-vlanmap 1-10
S1_config_elps1#protection-mode 1plus1-bidirectional
S1_config_elps1#revertive-mode revertive
S1_config_elps1#detect-fault continuity-check
S1_config_elps1#hold-off-time 2
S1_config_elps1#
Related command
N/A
1.2 Port Configuration Commands
1.2.1 elps id {working-transport | protection-transport}
To set a port where the ELPS working transport entity is located, run the following
command:
- 7 -

ELPS Configuration Commands
elps id working-transport
To delete the ELPS working transport entity configuration on a port, run the following
command:
no elps id working-transport
To set a port where the ELPS protection transport entity is located, run the following
command:
elps id protection-transport
To delete the ELPS protection transport entity configuration on a port, run the following
command:
no elps id protection-transport
Parameter
Parameter Description
id ID of the node
Default value
No ELPS configuration exists on ports by default.
Command mode
The physical port configuration mode and the converged port configuration mode
Explanation
The port cannot be configured until working-vlanmap, protection-mode, revertive-mode
and default-fault are all configured.
Example
S1_config#interface GigaEthernet 0/1
S1_config_g0/1# elps 1 working-transport
S1_config_g0/1#exit
Related command
elps id mep md md-string ma ma-string level level-id local local-id remote remote-id