Fuji Electric AR22VQR/VQL User manual

62E9-E-0185
ø22, ø30 Command Switches Equipped with Synchro Safe Contact
Emergency Stop Pushbutton Switches
AR22VQR/VQL, VPR, AR30VPR/VPL
CONTROL

●ø30 command switches
• Emergency stop pushbutton switches
Operator Appearance Contact arrangement*1 Type Button color
Push-lock, turn-reset AR30VPR 1NC AR30VPR-01R Red [R]
Mushroom head (ø44) 1NO+1NC AR30VPR-11R
2NC AR30VPR-02R
Support for Padlock 1NO+2NC AR30VPR-12R
1NO+3NC AR30VPR-13R
4NC AR30VPR-04R
2NO+4NC AR30VPR-24R
*1: Contacts other than those in the table above are also available. 3NC [03], 2NO+1NC [21], 1NO+4NC [14], 2NO+2NC [22], 2NO+3NC [23]
• Emergency stop illuminated pushbutton switches
Operator Appearance Operational lamp voltage/
lamp type
Contact arrangement*2 Type Button color
Push-lock, turn-reset AR30VPL 24 V AC/DC
LED lamp
1NC AR30VPL-01E3R Red [R]
Mushroom head (ø44) 1NO+1NC AR30VPL-11E3R
2NC AR30VPL-02E3R
Support for Padlock 1NO+2NC AR30VPL-12E3R
1NO+3NC AR30VPL-13E3R
4NC AR30VPL-04E3R
1NO+4NC AR30VPL-14E3R
24 V AC/DC
LED lamp
Interlocked with lamp circuit
1NC AR30VPL-01EAR
1NO+1NC AR30VPL-11EAR
2NC AR30VPL-02EAR
1NO+2NC AR30VPL-12EAR
1NO+3NC AR30VPL-13EAR
4NC AR30VPL-04EAR
1NO+4NC AR30VPL-14EAR
*2: Contacts other than those in the table above are also available. 3NC [03]
●ø22 command switches
• Emergency stop pushbutton switches
Operator Appearance Contact arrangement*1 Type Button color
Push-lock, turn reset or
pull reset
Mushroom head
(ø40)
AR22VQR 1NC AR22VQR-01R Red [R]
1NO+1NC AR22VQR-11R
2NC AR22VQR-02R
1NO+2NC AR22VQR-12R
1NO+3NC AR22VQR-13R
4NC AR22VQR-04R
2NO+4NC AR22VQR-24R
Push-lock, turn-reset
Giant Mushroom head
(ø65)
AR22VPR 1NC AR22VPR-01R
1NO+1NC AR22VPR-11R
2NC AR22VPR-02R
1NO+2NC AR22VPR-12R
1NO+3NC AR22VPR-13R
4NC AR22VPR-04R
2NO+4NC AR22VPR-24R
*1: Contacts other than those in the table above are also available. 3NC [03], 2NO+1NC [21], 1NO+4NC [14], 2NO+2NC [22], 2NO+3NC [23]
• Emergency stop illuminated pushbutton switches
Operator Appearance Operational lamp voltage/
lamp type
Contact arrangement*2 Type Button color
Push-lock, turn reset or
pull reset
Mushroom head (ø40)
AR22VQL 24 V AC/DC
LED lamp
1NC AR22VQL-01E3R Red [R]
1NO+1NC AR22VQL-11E3R
2NC AR22VQL-02E3R
1NO+2NC AR22VQL-12E3R
1NO+3NC AR22VQL-13E3R
4NC AR22VQL-04E3R
1NO+4NC AR22VQL-14E3R
24 V AC/DC
LED lamp
Interlocked with lamp circuit
1NC AR22VQL-01EAR
1NO+1NC AR22VQL-11EAR
2NC AR22VQL-02EAR
1NO+2NC AR22VQL-12EAR
1NO+3NC AR22VQL-13EAR
4NC AR22VQL-04EAR
1NO+4NC AR22VQL-14EAR
*2: Contacts other than those in the table above are also available. 3NC [03]
■Types
Emergency Stop Pushbutton Switches equipped with Synchro Safe Contact
AR22VQR/VQL, VPR, AR30VPR/VPL
Full Specification of Emergency Stop Pushbutton Switches Equipped with Safety Function

●New safetyfunction: Synchro safetycontact
When the Contact unit is removed from the operator, the NC contact opens and automatically turns off
●Side indicator is adopted by default (only for AR22V)
Easily check the green side indicator to ensure the condition of the NC
contact
●Integrated frame (bezel) for the protrusion There is
no need to acquire it separately as an accessory.
●
Safety trigger-action mechanism locks the pushbutton only when the contact is activated. Accidental lock of the
pushbutton is prevented. (compliant with EN60947-5-5)
●Direct opening mechanism for NC contacts to ensure that the contacts can be opened even in the unlikely event that
they become fused. (compliant with EN-60947-5-1, Appendix K/EN60947-5-5)
●Support by default for the degree of protection of operator: IP65 and the degree of protection of terminal section: IP2X
(compliant with EN60204-1).
●The arrows on the button have been standardized to the same color as the button itself in order to prevent erroneous
operation.
●Certified with UL/CSA standard and TÜV EN standard, and acquired China Compulsory Certification (CCC).
CE mark is attached.
●Certified with UL category code NISD (EMERGENCY STOP DEVICE).
■Enhanced safety
Operator
Contact unit
Safety
NC contact : OFFNC contact : ON
Side indicator : green Side indicator : none
NC contact is closed (ON)
under normal conditions
When the Contact unit is
removed, NC contact opens
(OFF).
AR22VQR AR30VPR
Flange
Button
AR22VQR
Shape of
protrusion
Frame
Shape of
protrusion
Bezel
●Enhanced visibility byadopting larger flange
on all models.
The larger yellow flange allows for better visibility of
the yellow background with no need of the
nameplate. (only for AR22V)

●Enhanced release performance of contact unit
One Touch mounting. The wire is not twisted at the time of attaching and detaching the unit.
●Reduce panel-mounting depth, connectable to up to six
contacts.
"2NO+4NC" contacts (an emergency stop) enables you
to construct two kinds of mechanical safety circuits (2NC:
redundancy).
●Pull-reset or turn-reset is available for the reset method (turn-reset only for AR30V type).
●The illumination can be interlocked with the lamp circuit.
●Adapter dedicated for ø30 mounting hole (only for AR22V)
●The layout of NC contacts can be arbitrarily designated (only contact specifications for 1NC to 3NC, special model).
For details, refer to the terminal arrangement designation on the final page.
Contact unit
Release cover
One
Touch!
Mounting
Operator
Only the release cover is turned around,
and the contact is not turned around.
Push down the
release cover
and turn the
cover to the left
Removal
■Support for Padlock
■Enhanced operability
●Enhanced routing
Since the layout of each contact is fixed regardless
of the number of contacts, any miswiring can be
prevented.
Terminal
arrangement
M3.5 is adopted for the
terminal screw diameter. It is
possible to unify it with other
inner devices.
Contact
arrange-
ment
Non-
illuminated
type
Illuminated
type Illuminated
type
(interlocked with
lamp circuit)
1NC to
4NC
1NO
1NC to
4NC
2NO
1NC to
4NC
Red square means contact
terminal “NC”
Green square means a lamp
terminal
Blue square means contact
terminal “NO”
32mm 47.5mm
Short!
●To avoid a restart due to careless reset of a pushbutton switch in case of emergency stop, make use of Padlock or HASP.
The total mass should be 1500 g or less. For information on applicable Padlock and HASP, refer to the final page.
HASP
When one is mounted at the
center
Padlock
Equivalent of 6835KARFRED manufactured
by Master Lock
Up to two mountable
HASP
Equivalent of 420 manufactured
by Master Lock
Up to two mountable
Release cover

■Specifications (indoor use)
Item Performance
Rated insulation voltage Ui 250 V AC/DC
Durability Mechanical 250,000 operations
Electrical 100,000 operations (AC-12, DC-13, DC-12)
Operating cycles per hour 900 operations/hour (On-load factor: 40%)
Withstand voltage Between live section and grounding: 2,000V AC, 1 minute
Between opposite polarity live sections: 2,000V AC, 1 minute
Insulation resistance Between live section and grounding: 100M:or more (500V DC megger)
Between opposite polarity live sections: 100M:or more (500V DC megger)
Rated impulse withstand voltage Uimp 2.5 kV
Conditional short-circuit current 1000 A
Short-circuit protective device gG10A (IEC60269 fuse)
Pollution degree 3 (panel inside: 2)
Vibration Malfunction: maximum double amplitude: 0.7 mm (maximum: 50 m/s2), frequency: 10 to 500 Hz
Durability: maximum double amplitude: 0.7 mm (maximum: 50 m/s2), frequency: 10 to 500 Hz *1
Shock Malfunction: 150 m/s2
Durability: 1000 m/s2*2
Operational ambient temperature Non illuminated type: -20 to +60°C, illuminated type: -20 to +50°C (no icing or no condensation)
Storage temperature -40 to +80°C (no icing or no condensation)
Relative humidity 45 to 85%RH (-5 to +40°C) (no icing or no condensation)
Degree of protection of operator (displaying) section IP65 (dust-proof, water jet proof): IEC 60529
Degree of protection of terminal section IP2X (when wired)
Connectable wire Stranded wire: up to 1.25 mm2, 24 to 16 AWG-CU
Solid wire: up to ø1.2 mm, 24 to 16 AWG-CU
*1: The feature is decided based on the test condition for EN60947-5-5 (1998).
*2: Except when the switch is mounted upside down.
■Contact ratings
●TÜV (EN60947-5-1), CCC (GB14048.5), and JIS C 8201-5-1
Conventional free air thermal current
(rated thermal current)
Ith
Rated operational voltage
Ue
Rated operational current Ie
AC DC
AC-15 (Inductive load) AC-12 (Resistive load) DC-13 (Inductive load) DC-12 (Resistive load)
5 A 24 V – – 1.0 A 2.0 A
120 V 3.0 A 5.0 A – –
125 V – – 0.22 A 0.4 A
240 V 1.5 A 3.0 A 0.1 A 0.2 A
●UL/CSA standards
• AC (cosø = 0.35) • DC (T0.95 = 6P, maximum: 300 ms)
Contact rating
Conventional free
air thermal current
120 V 240 V Contact rating Conventional free air
thermal current
Making current & breaking current
Code
(rated thermal current)
Making current
Breaking current
Making current
Breaking current
Code (rated thermal current) 125 V 250 V
B300 5 A 30 A 3 A 15 A 1.5 A R300 1 A 0.22 A 0.11 A
●NECA C 4521
Conventional free air thermal current
(rated thermal current)
Ith
Rated operational voltage
Ue
Rated operational current Ie
AC DC
AC-15 (Inductive load) AC-12 (Resistive load) DC-13 (Inductive load) DC-12 (Resistive load)
5 A 24 V – – 1.0 A 2.0 A
110 V 3.0 A 5.0 A 0.22 A 0.4 A
220 V 1.5 A 3.0 A 0.1 A 0.2 A
■Contact reliability
FUJI has confirmed that the product can be used in 1mA circuit conditions
at 5V AC or DC.
The operable range, however, may vary depending on the operational
ambient conditions and type of load.
Type of lamp Luminous color Operational lamp
voltage
Current consumption
LED lamp Red 24 V AC/DC 7.5 mA AC, 7.5 mA DC
Note: The LED lamp of these products cannot be replaced.
■Lamp rating and current consumption
■Dimensions, mm
●AR22VQR
●AR22VQL
●AR22VPR
●AR30VPR / VPL
Side indicator (green)
42
42
ø40
47.5 32
Ring packing
Washer
Terminal screw M3.5
Terminal cover
Panel thickness
1 to 6
Nut
ø42
Side indicator (green)
ø40
47.5 32
Ring packing
Washer
Terminal
cover Panel thickness
1 to 6
Nut
ø42
Side indicator (green)
ø65
47.5 32
Ring packing
Washer
Terminal
cover
Panel thickness
1 to 6
Nut
56 43 ø44
Nut
Ring packing
Terminal
cover Panel thickness
1 to 6
ø44

■Panel cutout [mm]
• AR22 • AR30
ø22.3 24.1
3.2 max R0.8
+0.2
0
+0.4
0
+0.4
0
4.8+0.2
0max R0.8
ø30.5+0.5
033.0+0.5
0
■Applicable panel thickness
The applicable panel thickness is 1 to 6mm. However, a ø30
switch mounted with their adapters should have an applicable
panel thickness of 1 to 4.5mm.
If a legend plate is used, the panel should be made thinner
by subtracting the thickness ofthatcomponent.
Note: If a legend plate or similar is used between the switch and
the fitting surface of the panel, the thickness of the legend panel should be
1.6mm or less. If the thickness exceeds the value of 1.6mm, it may prevent
the fixing function of the switch.
■Mounting the switch
●Removing the operator from the contact unit
Pull down the release cover of the contact unit, turn it
counter clock wise in 15 degrees, at the position pull the
contact unit, after that, the contact unit can be removed
from the operator.
Contactunit
Release cover
Operator
• Caution at the removing process of the contact unit from the operator
(1) When the contact unit is removed from the operator, at the process, “NO”
contact of the unit is turned into “ON” position.
(2) At the process when the contact unit is removed from the operator, don’t
give excessive force to the unit. It may cause the switch to break or to go
into maloperation.
●Mounting the operator onthe panel
Remove the tightening nut and washer from the packaged
state of the operator, checking the packing whether it is
placed properly onto the fitting surface of the front side of
the panel, insert the operator while keeping the mark at
the top position into the installation hole ofthe panel. The
operator penetrates the panel through the installation hole
tothe rear side ofthe panel. Itisfixed atthe rear side of
the panel with the tightening nut turned by the tightening
wrench.
Note 1 : The proper tightening torque is 1.0 to 1.5N·m for AR22, and 1.5 to 2.5N·m
for AR30.
Note 2 : The tightening nut has two faces, convex and concave. Face the concave
side of it to the panel when it tightens up the operator at the rear side of
the panel. If it is used in the opposite face, the operator will not be fixed
properly there.
Note 3 : Check the tightening nut regularly whether it tightens the operator
properly. If it seems that tightening is not sufficient, do not forget to
tighten the screw increasingly.
Note 4 : Do not use pliers or other improper tools to tighten the nut, and do not
tighten it excessively, or the nut may be damaged or the switch may
malfunction.
●Mounting the contact unit
Meet themark on the contact unit to the same mark
on the operator, insert the contact unit completely into the
operator until it makes a click sound. (The click sound
indicates the contact unit iscompletely connected to the
operator.)
After the contact unit is set, check the sequence and test
the unit.
●Caution when the contact unit is set in
(1) This release cover must be twisted in order to remove or
connect the contact unit to the operator portion. Please
note: The position of the release cover will be in a
different position (either twisted to the right or left) from
when it is connected to the operator.
(2) The triangle marks on the grooves of the operator and
contact unit will need to match up when connecting the
two parts. Please note: Not connecting the correct
grooves with the correct marks can cause it to break.
Operator
Panel
Triangular on contact unit mark
Triangular on operator mark
Contact unit
■Others
●Operation
• Do not hit or flip the button, or the button may be damaged.
Be sure to operate the button by hand. Operate the switch
manually. Don’t use any tools such as a hummer or other
tool to hit the switch for operation. It
may break the switch.
• To unlock the switch, turn the button
approximately 45° clockwise (in the
direction of the arrow) or pull out the
button. Do not operate or handle the
button with excessive force.
●Effect of receiving shock for the switch
•
•
●
•
•
Protrusion
Triangular on operator mark
Packing Tightening nut concave side
*1: The washer does not come with AR30.
*2: AHX536 for AR30 type.
Operator Panel
Washer *1
Tightening nut
Tightening wrench *2
(AR9A701)
Effects of receiving shock is based on the installation of
the switch. If the switch is mounted upside down, it may
not operate correctly.
Don't give excess force to the button as it will damage the
circuit.
Contact Unit
The contact unit is not dust proof, water proof or oil-tight.Do
not allow liquid or cutting chips to pass through inside or the
unprotected contact unit.
Don’t give any excessive physical load or shock to the
contact unit. It may break the switch ormake itintrouble to
lose its ON and OFF function.
Contact point
Gravity direction
Operator
Panel

Description Type Outline dimensions
Control box Type
AR9Y920
Application:
• Plastic control box for mounting the emergency stop pushbut-
ton switch separately.
• Mounting pitch
58
[Unit: mm]
79
ø22.3 (Equipped with a protrusion)
●Be sure to use and store the product within the rated ambient temperature and humidity ranges.
●Although the product resists ordinary cutting oils and coolant oils, do not use the unit in places where special oils may be
sprayed onto the product. If you experience this issue, please contact Fuji Electric.
●If dusts or filings accumulate in the gap between the button and the frame, the switch may fail to operate normally.
●This switch are for indoor use. Don’t use the switch for outdoor use and make sure that the product is not exposed to direct
sunlight.
●Do not use the product in the places that are subject to the adverse effects of ozone or corrosive gases.
●Features
• Control box for mounting the emergency stop pushbutton switch AR22VQR/VQL, VPR.
• It is easy to mount or add this box to the desired places away from the operating panel.
• Degree of protection : IP65 (when using applicable connector)
• Double-insulation structure without the need for an earth wire. (compliant with IEC536 class II)
• The knockout holes open at the top, bottom, and back.
• The emergency stop Legend plate (AR9P722) can be mounted.
■Storage and Usage Locations
■Control box dedicated for emergency stop pushbutton switch
■Accessories
Description Type Dimensions
Wrench Type Used with
AR9A701 AR22VQR, VQL, VPR
AHX536 AR30VPR, VPL
Application:
This allows you to tighten the tightening ring when mounting the
command switch on a panel.
AR9A701: ø28 mm × 60 mm
AHX536 : ø32 mm × 76 mm
Legend plate Type Used with
AR9P722-(1)(2) AR22VQR, VQL
AR9P723-(1)(2) AR22VPR
AR9P724-(1)(2) AR30VPR, VPL
Note 1: The values of code (1) and (2) above represent the Legend
below to be printed on the Legend plate
Type Code (1), (2) Letter height
Blank 00
EMERGENCY STOP 5A 5 mm
Note 2: These Legend plate are pasted on the product.
Note 3: The Legend plate is yellow and the Legend text is black
[Unit: mm]
ø60 *1
ø23 *2
Thickness: 0.35
*1: AR9P723: ø80
*2: AR9P724: ø31
AR22VQ, VPR
ø30 mounting adapter Type
AR9Y958
Application:
• This adapter allows you to
mount the switch on a panel of
ø30.5mm cutout in combination
with the operator of AR22VQ
and VPR (made of plastics, with
ring packing and tightening nut).
• The applicable panel thickness is
1 to 4.5 mm.
[Unit: mm]
ø30 mounting adapter ø30 packing ø30 tightening nut
ø45
2.5
5.5
0.5
6
ø30
ø42.4
ø22.2
ø41
ø30.3
ø40
ø36.5
r max = 0.8mm
4.8+0.2mm
0
33+0.5mm
0 ø30.5+0.5mm
0
●Applicable connector
• Knockout holes at the top and bottom: M20, Pg13.5, or G1/2
• Knockout holes at the back: M14 or G1/4
Applicable panel cutout size
62 Screw diameter: M4
41
* Tightening torque for mounting screws :
1.6 to 2.0 Nsm

●Positions of contact terminals "NC"
Emergency stop pushbutton switches Emergency stop illuminated pushbutton
switches
Emergency stop illuminated pushbutton
switches (interlocked with a lamp circuit)
Contact arrangement
1NC 2NC 3NC 4NC
24
4142
3231
13 11 12 14
22 21 23
RightLeft
TOP (▲)
RightLeft
b
4142
3231
13 11 12 14
22 21 a
TOP(▲)
RightLeft
b
4142
3231
13 11 12 14
22 21 a
TOP(▲)
11-12 11-12 11-12 11-12
21-22 21-22 21-22
31-32 31-32
41-42
■Terminal arrangement
■Others
Before mounting this product, wiring cables, operating this product, or maintaining and inspecting this product, make sure you read this
"Instruction Manual" and use this product properly.
■Recommended Padlock and HASP [unit: mm]
●Padlock ●HASP
●The total mass of the Padlock and HASP should be 1500 g or less.
20
Manufacturer Type
Master Lock 6835KARFRED
shackle
Body
38
45 38
20
ø6
ø45
Manufacturer Type
Master Lock 420, 421
ø25.4
P=75
6.5
115
5.5
* This figure shows the dimensions of a
type-420 HASP.
Information in this catalog is subject to change without notice.
1-5-45 Minami, Konosu-shi, Saitama, 369-0192, Japan
URL http://www.fujielectric.co.jp/fcs/eng
2018-10 PDF FOLS 62E9-E-0185
This manual suits for next models
2
Table of contents
Popular Switch manuals by other brands

TRENDnet
TRENDnet TK-802R Quick installation guide

ELMARK
ELMARK TE 17 manual

Kramer
Kramer DIP-31M user manual

Teltronics
Teltronics SEB NET-PATH Installation and operation guide

GE
GE CWLSWDMBWF1 installation guide

Brocade Communications Systems
Brocade Communications Systems VDX6730 Hardware reference manual