Fujitsu UTY-LRHYM User manual

English
DeutschFrançaisEspañolItalianoEλληvIkάPortuguêsРусскийTϋrkçe
PART NO. 9378626041-03
INSTALLATION MANUAL
For authorized service personnel only.
AIR CONDITIONER
IR RECEIVER UNIT
UTY-LRHYM
9378626041-03_IM.indb 1 14/5/2555 9:07:09

En-1
2. ACCESSORIES
The following installation parts are supplied.
Use them as required.
Name and Shape Q’ty Application
Installation manual
1
This manual
Operating manual
1
Instruction book for operation
Receiver unit
1
For receiving the signal from the
remote controller
Cover
1
For covering receiver unit
Insulation
1
For protecting PCB from dust
Receiver unit wire A
5m
1
For connecting receiver unit wire B
to receiver unit
Receiver unit wire B
0.2m
1
For connecting receiver unit wire A
to PCB of indoor unit
Bracket (cover)
1
For xing receiver unit to the wall or
ceiling
Screw (M3 x 12mm)
2
For installing remote controller
holder to the wall
Screw (M4 x 20mm)
2
For installing receiver unit to the
wall or ceiling
Remote
controller
1
For air conditioner operation
Battery (R03/LR03)
2
For remote controller
Remote
controller
holder 1
Use as remote controller holder
1. SAFETY PRECAUTIONS
Let the customer keep this installation manual because it is needed•
when the air conditioner or receiver unit is serviced or moved.
WARNING
This mark indicates procedures which, if improperly
performed, might lead to the death or serious injury of
the user.
Never touch electrical components immediately after the power supply•
has been turned off. Electrical shock may occur. After turning off
the power, always wait 5 minutes or more before touching electrical
components.
For the air conditioner to operate satisfactorily, install it as outlined in•
this installation manual.
Installation work must be performed in accordance with national wiring•
standards by authorized personnel only.
Do not cut, shorten, or extend the cable in the standard parts.•
Do not turn on the power until all installation work is complete.•
CAUTION
This mark indicates procedures which, if improperly
performed, might possibly result in personal harm to
the user, or damage to property.
Do not wire the receiver unit wire together with or parallel to the•
connection cables, transmission cables, remote controller cables, bus
cable and power supply cables of the indoor and outdoor units. It may
cause erroneous operation.
Do not install the receiver unit cable near a source of electromagnetic•
waves.
Do not install where there is the danger of combustible gas leakage.•
Do not install near heat sources, steam.•
Contents
1. SAFETY PRECAUTIONS .....................................................................1
2. ACCESSORIES ....................................................................................1
3. OPTIONAL PARTS................................................................................2
4. FUNCTIONS AND DIMENSIONS .........................................................2
5. SELECTING THE INSTALLATION LOCATION.....................................2
6. INSTALLING THE RECEIVER UNIT
6.1. Select the wiring pattern.................................................................3
6.2. Select the installation method ........................................................3
7. WIRING.................................................................................................3
8. TURNING ON THE POWER.................................................................4
9. SETTING THE REMOTE CONTROLLER
9.1. Load batteries (R03/LR03 × 2).......................................................4
9.2. Installing the remote controller holder ............................................4
10. FUNCTION SETTING ...........................................................................4
11. SELECTING THE REMOTE CONTROLLER SIGNAL CODE ..............6
12. TEST OPERATION ...............................................................................6
13. ERROR CODES ...................................................................................7
9378626041-03_IM.indb 1 14/5/2555 9:07:10

En-2
5.
SELECTING THE INSTALLATION LOCATION
Consult the customer and determine the installation location according to the
following:
(1) The receiver unit cable can be extended up to 10m. (To extend the
wiring, purchase the optional receiver unit wire C.)
(2) The signal reception angle of the receiver unit is shown in the gures
below.
(3) Do not install the receiver unit near a uorescent light. (The unit must be
at least 1m away from a light source.)
(4) Do not install the receiver unit where it will be exposed to direct sunlight.
(5) Do not install the receiver unit where it will be exposed directly to the
airow from the indoor unit.
Indoor unit
Ceiling
120°
Max. 10m
5m Receiver
unit
Remote
controller
Signal reception
angle
Indoor unit
Ceiling
120°
Remote
controller
Max. 10m
5m
Receiver unit
Signal reception angle
6. INSTALLING THE RECEIVER UNIT
CAUTION
Do not touch the PCB or PCB parts of receiver unit directly with your•
hands.
Fixing of the holder cover with the screws in the standard parts may be •
unsuitable if the wall or ceiling material is weak. If so, prepare screws
suitable for the wall or ceiling material, and x it.
3. OPTIONAL PARTS
Name and Shape Q’ty Application Part No.
Receiver unit wire C
10m 1
For extending
the receiver
unit wire
9707598025
4. FUNCTIONS AND DIMENSIONS
OPERATION indicator
lamp (GREEN)
TIMER indicator
lamp (ORANGE)
ECONOMY indicator
lamp (GREEN)
MANUAL AUTO button
90
145
REMOTE CONTROL
SIGNAL RECEIVER
84.6
Unit: mm
57.6
22.9
72.4
60
83.5
118.4
71.8
57.4
11.5
Dimensions
18.5
17
9378626041-03_IM.indb 2 14/5/2555 9:07:10

En-3
II. Attaching the receiver unit (Wiring pattern A)
1
2
Holder
(PCB)
Holder cover
Screw
1Remove the screw.
2Remove holder (PCB) from
holder cover.
1Cut the projections in the areas
indicated with a and
remove them.
(Be careful not to injure
yourself on the cut edges of
the holder cover.)
1
2
2
Screws (M4 x 20mm)
Wall or
ceiling
Hook
1
2
1 Afx the insulation to the
holder cover.
2Attach the holder cover to the
wall or ceiling with the screws
(included with the standard
parts).
1Reattach holder cover. (Make
sure that the hook on the
holder cover is caught on the
holder [PCB].)
2 Fix holder (PCB) by the screw.
7. WIRING
WARNING
Before starting work, make sure that power is not being supplied to the•
indoor unit.
Always fasten the outside covering of the connection cord with the cord•
clamp. (If the insulator is chafed, electric leakage may occur.)
CAUTION
Do not touch the PCB or PCB parts of indoor unit directly with your•
hands.
When xing the wiring, be careful to avoid touching the edge of the •
indoor unit or the control box.
Install the remote controller wires so as not to be direct touched with•
your hand.
Make sure to use and roll an insulation tube of more than 1 mm thick•
at the connection point of the receiver unit wire A and the receiver unit
wire B.
Insulation tube
CONNECT
Tape
6.1. Select the wiring pattern
Pattern A From the top of the receiver unit: No additional work is
necessary.
Pattern B From behind the receiver unit: Perform the following procedure
to route the wiring behind the receiver unit.
1
2
Holder
(PCB)
Holder cover
Screw
1
1Remove the screw.
2Remove holder (PCB) from
holder cover.
1Route the wiring as shown
in the gure.
2
1
Hook Holder cover
Screw
1Reattach holder cover. (Make sure that the hook on the holder
cover is caught on the holder [PCB].)
2 Fix holder (PCB) by the screw.
6.2. Select the installation method
Method 1 Receiver unit embedded in a wall or ceiling:
Refer to “I. Embedding the receiver unit.”
Method 2 Receiver unit attached to a wall or ceiling:
Refer to “II. Attaching the receiver unit.”
I. Embedding the receiver unit (Wiring pattern A or B)
60mm - 64mm
120mm - 140mm
Screws (M4 x 20mm)
1
2
2
Wall or ceiling
1Make a hole in the wall or
ceiling.
(Depth: 25mm or more)
1 Afx the insulation to the
holder cover.
2
Attach the holder cover and
bracket (cover) to the wall
or ceiling with the screws
(included with the standard
parts).
Cover
Bracket
(cover)
Cover
11
2
1Install the cover.
Hook the 2 projections on the top of the cover onto the bracket
(cover), and then hook the projection on the bottom of the cover
onto the bracket (cover).
2Make sure that there is no gap between the cover and the wall
or ceiling.
3
4
3
3
1
1
2
1
2
2
9378626041-03_IM.indb 3 14/5/2555 9:07:11

En-4
9.2. Installing the remote controller holder
CAUTION
Check that the indoor unit correctly receives the signal from the remote•
controller, then install the remote controller holder.
Select the remote controller holder selection site by paying careful•
attention to the following:
Avoid places in direct sunlight.
Select a place that will not be affected by the heat from a stove, etc.
Install the remote controller with a distance of 5 m between the remote•
controller and the signal receiver of the receiver unit as the criteria.
However, when installing the remote controller, check that it operates
positively.
Install the remote controller holder to a wall, pillar, etc. with the screw.•
(1) Mount the Holder.
Screws
(M3 ×12)
(2) Set the Remote Controller.
Insert
Press in
(3)
To remove the Remote Controller (when use at hand).
Slide up
Pull out
10. FUNCTION SETTING
Perform the “FUNCTION SETTING” according to the installation conditions
using the remote controller.
Entering the Function Setting Mode
While pressing the FAN button and SET TEMP. (•) simultaneously,
press the RESET button to enter the function setting mode.
STEP 1
Selecting the Remote Controller Signal Code
Use the following steps to select the signal
code of the remote controller. (Note that the air
conditioner cannot receive a signal code if the
air conditioner has not been set for the signal
code.)
The signal codes that are set through this
process are applicable only to the signals in the
FUNCTION SETTING.
For details on how to set the signal codes
through the normal process, refer to 11.
SELECTING THE REMOTE CONTROLLER
SIGNAL CODE.
1Press the SET TEMP. ( ) ( ) button to
change the signal code between .
Match the code on the display to the air conditioner signal code. (initially
set to )
(If the signal code does not need to be selected, press the MODE button
and proceed to STEP 2.)
2Press the TIMER MODE button and check that the indoor unit can
receive signals at the displayed signal code.
3Press the MODE button to accept the signal code, and proceed to STEP 2.
PROCEDURE
Please refer to the installation manual of each indoor unit for details.
EXAMPLE
Connect the wires, and then use heat shrink tubing to
protect the connection from dust and water droplets.
Provide a trap in the receiver
unit wiring.
(To prevent water droplets
from entering the receiver unit
and the connector)
If the wiring length is 10m, replace with
receiver unit wire C (optional parts).
Receiver unit wire A 5m
CONNECT
Receiver unit
Heat shrink
tubing
(ø25 L130)
MAX. 10m
Bundle and fasten
the excess wiring.
After shrinking
both ends of
the heat shrink
tubing, seal
the ends with
electrical tape.
Indoor unit
Ceiling
8. TURNING ON THE POWER
1Turn on the breaker.
2Make sure that the operation indicator lamp and timer indicator lamp are
slowly ashing alternately.
If the auto restart function has been set, the air conditioner will operate•
with the settings immediately before the power supply was turned off.
If an error has occurred, the lamps on the receiver unit will ash quickly •
to indicate the error code. (Referring to 13 of this installation manual)
9. SETTING THE REMOTE CONTROLLER
9.1. Load batteries (R03/LR03 × 2)
1Press and slide the battery compartment lid on the reverse side to open
it.
Slide in the direction of the arrow while pressing the mark.
2Insert batteries.
Be sure to align the battery polarities ( ) correctly.
3Close the battery compartment lid.
CAUTION
Take care to prevent infants from accidentally swallowing batteries.•
When not using the Remote Controller for an extended period, remove •
the batteries to avoid possible leakage and damage to the unit.
If leaking battery uid comes in contact with your skin, eyes, or mouth, •
immediately wash with copious amounts of water, and consult your
physician.
Dead batteries should be removed immediately and disposed of properly,•
either in a battery collection receptacle or to the appropriate authority.
Do not attempt to recharge dry batteries.•
NOTES
Never mix new and used batteries, or batteries of different types.•
Batteries should last about 1 year under normal use. If the Remote•
Controller’s operating range becomes appreciably reduced, replace the
batteries and press the RESET button with the tip of a ballpoint pen or
other small object.
10°C HEAT
9378626041-03_IM.indb 4 14/5/2555 9:07:12

En-5
1) Filter sign
The indoor unit has a sign to inform the user that it is time to clean the lter.
Select the time setting for the lter sign display interval in the table below
according to the amount of dust or debris in the room. If you do not wish the
lter sign to be displayed, select the setting value for “No indication”.
( ... Factory setting)
Setting description Function number Setting value
Standard
11
00
Long interval 01
Short interval 02
No indication 03
The lter sign interval time is different according to Indoor unit type.
Please refer to the installation manual of each indoor unit for details.
FILTER INDICATOR RESET
It lights on if the lter became dirty.
Clean the lter referring to “CLEANING AND CARE (indoor unit operating
manual)”.
After cleaning, press the MANUAL AUTO button (indoor unit) for 2 seconds
or less on the indoor unit.
Indicator Lamp
OPERATION or
TIMER or
ECONOMY or
: Flashing (3 times) : OFF
2) Static pressure
Select appropriate static pressure according to the installation conditions.
Please refer to the installation manual of each indoor unit for details.
3) Cooler room temperature correction
Depending on the installed environment, the room temperature sensor may
require a correction.
Please refer to the installation manual of each indoor unit for details.
4) Heater room temperature correction
Depending on the installed environment, the room temperature sensor may
require a correction.
Please refer to the installation manual of each indoor unit for details.
5) Auto restart
Enable or disable automatic system restart after a power outage.
( ... Factory setting)
Setting description Function
number
Setting
value
Yes 40 00
No 01
* Auto restart is an emergency function such as for power failure etc.
Do not start and stop the indoor unit by this function in normal operation.
Be sure to operate by the controller, or external input device.
6) Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when use the control by Wired remote
controller temperature sensor.
( ... Factory setting)
Setting description Function
number
Setting
value
No 42 00
Yes 01
* If setting value is “00” :
Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is “01” :
Room temperature is controlled by either indoor unit temperature sensor or
remote controller unit sensor.
The air conditioner signal code is set to A prior to shipment. Contact your
retailer to change the signal code.
The remote controller resets to signal code A when the batteries in the
remote controller are replaced. If you use a signal code other than signal
code A, reset the signal code after replacing the batteries.
If you do not know the air conditioner signal code setting, try each of the
signal codes ( ) until you nd the code which operates the air
conditioner.
STEP 2
SELECTING THE FUNCTION NUMBER AND SETTING VALUE
Refer to the indoor unit installation manual for details on the function
numbers and setting values.
Selecting the Function Number and Setting Value
1Press the SET TEMP. ( ) ( ) buttons to select the function number.
(Press the MODE button to switch between the left and right digits.)
2Press the FAN button to proceed to setting the value.
(Press the FAN button again to return to the function number selection.)
3Press the SET TEMP. ( ) ( ) buttons to select the setting value.
(Press the MODE button to switch between the left and right digits.)
4Press the TIMER MODE button, and START/STOP button, in the order
listed to conrm the settings.
5Press the RESET button to cancel the function setting mode.
6After completing the FUNCTION SETTING, be sure to turn off the power
and turn it on again.
10°C HEAT
Function number
Setting value
CAUTION
After turning off the power, wait 10 seconds or more before turning on it
again. The FUNCTION SETTING doesn’t become effective if it doesn’t
do so.
Function Details
Functions Function
number Slim duct
1) Filter sign 11 * 1
2) Static pressure -
3) Cooler room temperature
correction 30
4) Heater room temperature
correction 31
5) Auto restart 40
6) Indoor room temperature
sensor switching function 42
7) Remote controller signal code 44
8) External input control 46
9) Room temperature control
switching 48
*1: It is effective only to install IR Receiver unit.
9378626041-03_IM.indb 5 14/5/2555 9:07:13

En-6
7) Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
( ... Factory setting)
Setting description Function
number
Setting
value
A
44
00
B 01
C 02
D 03
8) External input control
“Operation/Stop” mode or “Forced stop” mode can be selected.
( ... Factory setting)
Setting description Function
number
Setting
value
Operation/Stop mode
46
00
(Setting forbidden) 01
Forced stop mode 02
9) Room temperature control switching
(Only for Wired remote controller)
This setting is used to set the room temperature control method when the
wired remote controller is selected by the Indoor Room Temperature
Sensor Switching Function.
( ... Factory setting)
Setting description Function
number
Setting
value
Control by the sensors of both
the indoor unit and the wired
remote controller. 48
00
Control only by the sensor of
the wired remote controller 01
10) Setting record
Record any changes to the settings in the following table.
Setting description Setting value
Filter sign
Static pressure
Cooler room temperature correction
Heater room temperature correction
Auto restart
Indoor room temperature sensor switching
function
Remote controller signal code
External input control
Room temperature control switching
After completing the FUNCTION SETTING, be sure to turn off the power
and turn it on again.
11. SELECTING THE REMOTE
CONTROLLER SIGNAL CODE
When 2 or more air conditioners are installed in a room and the remote
controller is operating an air conditioner other than the one you wish to
set, change the signal code of the remote controller to operate only the air
conditioner you wish to set (4 selections possible).
When two or more air conditioners are installed in a room, please contact
your retailer to set the individual air conditioner signal codes.
Selecting the Remote Controller Signal Code
Use the following steps to select the signal code of the remote controller.
(Note that the air conditioner cannot receive a signal code if the air
conditioner has not been set for the signal code.)
1Press the START/STOP button until only the clock is displayed on the
remote controller display.
2Press the MODE button for at least 5 seconds to display the current
signal code (initially set to ).
3Press the SET TEMP. ( ) ( ) button to change the signal code
between .
Match the code on the display to the air conditioner signal code.
4Press the MODE button again to return to the clock display. The signal
code will be changed.
10°C HEAT
If no buttons are pressed within 30 seconds after the signal code is
displayed, the system returns to the original clock display. In this case,
start again from step 1.
The air conditioner signal code is set to A prior to shipment. Contact your
retailer to change the signal code.
The remote controller resets to signal code A when the batteries in the
remote controller are replaced. If you use a signal code other than signal
code A, reset the signal code after replacing the batteries.
If you do not know the air conditioner signal code setting, try each of the
signal codes ( ) until you nd the code which operates the air
conditioner.
12. TEST OPERATION
The outdoor unit may not operate depending on the room temperature. In
this case, press the test run button on the remote controller while the air
conditioner is running. (Point the transmitter section of the remote controller
toward the air conditioner and press the test run button with the tip of a
ballpoint pen, etc.)
Transmitter section
Test run button
To end test operation, press the remote controller START/STOP button.
9378626041-03_IM.indb 6 14/5/2555 9:07:13

En-7
13. ERROR CODES
If you use a wired type remote control, error codes will appear on the remote
control display. If you use a wireless remote control, the lamp on the IR
receiver unit will output error codes by way of blinking patterns. See the
lamp blinking patterns and error codes in the table below.
An error display is displayed only during operation.
Error display Wired
remote
controller
Error code
Mode
DESCRIPTION
OPERA-
TION
lamp
(green)
TIMER
lamp
(orange)
ECONO-
MY lamp
(green)
(1)
(1)
Communi-
cation
Serial commu-
nication error
(1)
(2)
Communi-
cation
Remote controller
communication
error
(1)
(5)
Communi-
cation
Scan error
(2)
(1)
Function
setting
Initial setting
error
(2)
(2)
Function
setting
Indoor unit
capacity error
(2)
(3)
Function
setting
Connection
disabled
(series error)
(2)
(4)
Function
setting
Connection
unit number
error
(3)
(2)
Indoor
unit
Indoor unit
main PCB
error
(3)
(5)
Indoor
unit
Manual auto
switch error
(4)
(1)
Indoor
unit
Room
(temperature)
thermistor error
(4)
(2)
Indoor
unit
Indoor unit
Heat Ex.
sensor error
(5)
(1)
Indoor
unit
Indoor unit fan
motor error
(5)
(3)
Indoor
unit
Water Drain
error
(5)
(15)
Indoor
unit
Indoor unit
error
(6)
(2)
Outdoor
unit
Outdoor unit
main PCB
error
(6)
(3)
Outdoor
unit
Inverter PCB
error
(6)
(4)
Outdoor
unit
Active lter
error, PFC
circuit error
(6)
(5)
Outdoor
unit
IPM error
(6)
(10)
Outdoor
unit
Display panel
error
(7)
(1)
Outdoor
unit
Discharge
thermistor
error
(7)
(2)
Outdoor
unit
Compressor
thermistor
error
(7)
(3)
Outdoor
unit
Outdoor unit
Heat Ex.
Sensor error
(7)
(4)
Outdoor
unit
Outdoor
thermistor
error
(7)
(5)
Outdoor
unit
Suction Gas
thermistor
error
(7)
(7)
Outdoor
unit
Heat sink
thermistor
error
(8)
(2)
Outdoor
unit
Sub-cool Heat
Ex. gas
thermistor
error
(8)
(3)
Outdoor
unit
Liquid pipe
thermistor
error
(8)
(4)
Outdoor
unit
Current sensor
error
(8)
(6)
Outdoor
unit
Pressure
sensor error
(9)
(4)
Outdoor
unit
Trip detection
(9)
(5)
Outdoor
unit
Compressor
motor control
error
(9)
(7)
Outdoor
unit
Outdoor unit
fan motor 1
error
(9)
(9)
Outdoor
unit
4-way valve
error
(10)
(1)
Refrigerant
system
Discharge
temperature 1
error
(10)
(3)
Refrigerant
system
Compressor
temperature
error
(10)
(5)
Refrigerant
system
Pressure
error 2
(13)
(2)
Branch
box
Unit ow
divider error
9378626041-03_IM.indb 7 14/5/2555 9:07:16

En-8
Display mode : 0.5s ON / 0.5s OFF
: 0.1s ON / 0.1s OFF
( ) : Number of ashing
Wired Remote Controller Display
Error code
9378626041-03_IM.indb 8 14/5/2555 9:07:16
Other manuals for UTY-LRHYM
1
Table of contents
Other Fujitsu Receiver manuals