The product has undergone static load testing at 400 kg. The minimum size of the wall mounting
fixtures is ≥45 x ≥195 x (700) mm. The fixtures must be affixed to solid structures. The fixtures
must be mounted in accordance with the measurements specified in the diagram.
The electrical junction box must be positioned to the left of the mid-line, as shown in the drawing.
IP44 junction box (not included)
The base comes with a 230V AC 10A socket.
A residual-current device is recommended for the 230 V AC power supply.
A qualified electrician must perform the connection.
The water connection must be positioned to the right of the mid-line, as shown in the drawing.
1. Mid-line
2. Wall
3. Electrical connection
4. Water connection
5. Wall mounting fixtures ≥45 x ≥195
6. Finished floor
7. Wastewater connection on the wall (Ø110 mm). The pipe is cut at the level of the wall.
8. Wastewater connection on the floor (Ø110 mm). The pipe is cut at the level of the finished floor.
9. Water supply with a shut-off valve equipped with a 1/2” external thread (G15). Thread upwards.
50
195
500
195
60 60
400
Note the dimensions!
3
21
4
5
6
7
5
0110 mm
9
The electrical and water connection must not extend from the
wall by more than 50 mm. NOTE! Exceeding the maximum
depth of 50 mm prevents the toilet seat’s downward move-
ment!
110 mm
8
180 mm
= 0 mm!
0110 mm