IMPORTANT
Read these instructions for use carefully.
Familiarise yourself with the appliance before
connecting it to its gas container. Keep these
instructions for future reference.
ONLY USE IN WELL-VENTILATED AREAS.
CARBON MONOXIDE HAZARD - USING THIS
APPLIANCE IN AN ENCLOSED SPACE MAY CAUSE
DEATH. DO NOT USE IN CARAVANS, TENTS,
MARINE CRAFT, CARS, MOBILE HOMES OR
SIMILAR LOCATIONS.
• Do not modify this appliance.
• Check that seals between the appliance and the
gas container are in place and in good condition
before connecting the gas container.
• Do not use the appliance if it has damaged or worn
seals.
• Do not use this appliance if it is leaking, damaged
or does not operate properly.
• This appliance must only be serviced by an
authorized person.
• The openings at the base of the burner provide air
for combustion, they should never be obstructed. If
the ame becomes signicantly orange check these
openings for a blockage.
• If the appliance cannot be adjusted to perform
correctly it should not be used until serviced or
repaired.
• To check that the gas container is lled, when
shaken a sloshing sound will be heard.
CAUTION: Accessible parts may be very hot. Keep
young children away.
USE OUTDOORS ONLY.
PROPANE/UNIVERSAL LPG PRODUCT
This appliance shall only be used with a propane gas
cylinder certied to AS2469 or Universal L.P.G.
IT MAY BE HAZARDOUS TO ATTEMPT TO FIT
OTHER TYPES OF GAS CONTAINERS.
Gas cylinders should be stored outdoors in a well
ventilated area out of reach of children. Any indoor
storage shall comply with AS/NZS 1596.
Only use the hose assembly as supplied with this
appliance for connection to the cylinder - DO NOT USE
ADAPTORS.
Maximum hose length is 100cm.
After use, turn the gas cylinder valve off, wait for the
ame to go out, and then turn the appliance control
valve(s) off.
Avoid twisting or kinking the exible hose.
If there is a leak on your appliance (smell of gas)
immediately attempt to turn off the cylinder valve.
Remove the appliance to a well-ventilated location
away from any ignition source. Check for leaks using
soapy water. Do not try to detect leaks using a ame.
Model No. CS1095
Fine burner adjustment controls
Durable powder coated nish
Removable cooking trivet for easy cleaning
Units folds to a compact size with handle
Windshields on three sides
Complete with hose to suit 3/8” BSP-LH cylinders
For outdoor use only
Gas certied to Australian and New Zealand Standards
Gasmate®is a registered trademark of: Sitro Group Australia Pty Ltd www.gasmate.com.au
Aber Holdings Ltd - N.Z www.gasmate.co.nz
Important: Retain these instructions for future use.
03962 09/19
For any queries or assistance call
Customer Service
(Australia Only)
1300 174 876
Hours of operation:
Monday to Friday 8.00am - 5.00pm EST
Do not return to place of purchase.
Keep your purchase receipt, this will be required to
make any claims under the 12 month warranty.
Gasmate®is a registered trademark of:
Sitro Group Australia Pty Ltd www.gasmate.com.au
Aber Holdings Ltd, N.Z www.gasmate.co.nz

GENERAL INFORMATION
This appliance shall only be used in an above ground
open-air situation with natural ventilation, without stagnant
areas, where gas leakage and products of combustion are
rapidly dispersed by wind and natural convection.
Any enclosure in which the appliance is used shall
comply with the following:
An enclosure with walls on all sides, but at least one
permanent opening at ground level and no overhead
cover (see Example 1).
Within a partial enclosure that includes an overhead cover
and no more than two walls (see Example 2 & 3).
Within a partial enclosure that includes an overhead
cover and more than two walls, the following will
apply:
at least 25% of the total wall area is completely open,
and at least 30% of the remaining wall area is open and
unrestricted (see Example 4 & 5).
In the case of balconies, at least 20% of the total wall
area shall be and remain open and unrestricted.
DIAGRAMMATIC REPRESENTATIONS OF OUTDOOR AREAS
The following gures are diagrammatic representations of outdoor areas. Rectangular areas have been used in these
gures – the same principles apply to any other shaped area.
INSTRUCTIONS
Read these instructions for use carefully. Familiarise
yourself with the appliance before connecting it to its gas
container. Keep these instructions for future reference.
1. Remove appliance from carton and remove any
transit protection material.
2. Open the lid to the vertical position, fold out the
windshield and engage the clips with the slots in the
side of the body.
3. Lift the front edge of the wire trivet to remove the
hose from its storage position and replace the
trivet. Check the “O” rings for any damage before
connecting hose. Connect the hose to the appliance
by pushing the hose tting into the inlet connector,
then tightening the knurled nut until hand tight and
rm.
4. Check that the control valves for the burners are
turned OFF (clockwise for off).
5. Connect the hose to the cylinder and use a spanner
to tighten rmly.
6. Ensure the chrome wire lid latches or feet are in
position to maintain clearance between the appliance
and the support surface and for good airow and
correct operation.
This appliance should only be operated on a hard,
at, level surface.
a. The appliance area must be kept clear and
free of combustible materials, gasoline and other
ammable vapours and liquids.
b. Gas orices and burner must be kept clear of dirt
and cobwebs. Flow of combustion and
ventilation air through the perforated portions of
the appliance must not be obstructed.
c. Any cleaning agent used on the appliance should
be of a non-combustible and non-corrosive
nature.
7. Proper clearance from combustible materials must be
maintained at all times. The minimum clearances are
as follows:
Minimum Clearance from Combustibles:
Rear 600mm Side 600mm Top 600mm
Combustible materials are considered to be wood,
compressed paper, plant bres, plastic, plexiglas or other
materials capable of being ignited and burned.
Such materials shall be considered combustible even
though ame proofed, re-retardant treated or plastered.
Additional clearance may be required for glass, painted
surfaces and other materials which may be damaged by
radiant or convection heat.
LIGHTING & BURNER ADJUSTMENT
1. Open the cylinder control valve about one full turn
ensuring that all the control knobs on the stove are
turned OFF at this point. DO NOT ATTEMPT TO
LIGHT THE STOVE!
2. To check for leaks on all connections use a solution
of soapy water (dish washing liquid and water is
ne). Brush it on or use a spray bottle. Ensure the
connections have a good coating.
3. If the connection is leaking, bubbles will start to grow
in the soapy solution. If this happens shut off the gas
supply at the cylinder.
4. Tighten the connections using a spanner then repeat
steps 1-2. The connection is gas tight when no
bubbles grow around the gas connection.
5. Each burner can be operated independently by
turning the control valve on (rotating the knob anti-
clockwise about one turn) and applying a lighted
match to the burner. The ame can be regulated by
opening or closing the valve.
6. If the burner fails to ignite after several attempts,
turn the control knob to OFF and wait a few minutes
before attempting re-ignition.
7. Turn the control knob anti-clockwise to increase the
ame, or clock-wise to decrease the ame.
8. IMPORTANT: When turning the stove off at
completion of use, the gas supply should be rst
turned off at the cylinder, and all gas in the hose burnt
away before closing the valves on the stove. Leaving
the gas in the hose can cause injector blockage.
Note: If re-ignition if necessary while the stove is still
hot, you must wait for a minimum of 5 minutes before
commencing to re-ignite (this allows accumulated gas
fumes to clear).
REGULAR MAINTENANCE
Clean the body of your appliance using a cotton cloth
soaked in soapy hot water. Never use abrasive or
ammable cleaning products. Use a soft brush to clean
the burner.
STORAGE
When the appliance is not used it must be
stored in a suitable area to protect it from any risk of
deterioration. Keep it in a well ventilated area and out of
reach of children.
HANDY HINTS
a. The hose connections, cylinder valve outlet
connection and appliance inlet connection should
be kept clean. If grit or dirt is present when the
connections are made, the rubber seals at each end
of the hose may be damaged.
b. To clear blocked injector wash in petrol or use
compressed air to blow out obstruction. Do not use
wires or prickers. If washing is unsuccessful, t new
injector.
c. Check for gas leaks with SOAPY WATER. DO NOT
USE A FLAME.
d. Ensure that the area in which the appliance is to be
used is well ventilated and DO NOT use as a space
heater in tent, caravan, etc.
e. Ensure the appliance is completely extinguished
before disconnecting from the cylinder.
f. DO NOT place the appliance closer than 60cm from
ceiling or ammable material.
g. Avoid moving the appliance during use as this can
cause large ames.
h. Allow the appliance to cool down after use before
touching the burners, trivet, windshields or folding up
for transportation.
WARNING
Be very careful when turning the burner down.
Visually check to ensure the ame does not go out.
INJECTOR REPLACEMENT
If the burner will not light the injector may be blocked.
1. Undo and remove the burner screw on the
underside of the body.
2. With a small shifter remove the injector from the gas
valve and either clean or replace it (refer to Handy
Hints).
3. Re-attach the burner.
SAFE APPLIANCE LOCATIONS
KNOB MARKINGS
INJECTOR
SPARE PARTS
Knob GMKN-2
Hose GMH3
O-Ring (Spindle) GMORN1
O-Ring (Cyl End) GMORN6
O-Ring (Stove End) GMORN4
Burner 85 1095HBNR
Jet 85 1095HJET
Gas Type Number of
Burners
Injector
Size Total BTU MJ/h
Total g/h Total Certificate
ULPG 2 0.20mm 20,850 BTU 22 MJ/h 436 g/h GMK10385
GAS CONSUMPTION

GENERAL INFORMATION
This appliance shall only be used in an above ground
open-air situation with natural ventilation, without stagnant
areas, where gas leakage and products of combustion are
rapidly dispersed by wind and natural convection.
Any enclosure in which the appliance is used shall
comply with the following:
An enclosure with walls on all sides, but at least one
permanent opening at ground level and no overhead
cover (see Example 1).
Within a partial enclosure that includes an overhead cover
and no more than two walls (see Example 2 & 3).
Within a partial enclosure that includes an overhead
cover and more than two walls, the following will
apply:
at least 25% of the total wall area is completely open,
and at least 30% of the remaining wall area is open and
unrestricted (see Example 4 & 5).
In the case of balconies, at least 20% of the total wall
area shall be and remain open and unrestricted.
DIAGRAMMATIC REPRESENTATIONS OF OUTDOOR AREAS
The following gures are diagrammatic representations of outdoor areas. Rectangular areas have been used in these
gures – the same principles apply to any other shaped area.
INSTRUCTIONS
Read these instructions for use carefully. Familiarise
yourself with the appliance before connecting it to its gas
container. Keep these instructions for future reference.
1. Remove appliance from carton and remove any
transit protection material.
2. Open the lid to the vertical position, fold out the
windshield and engage the clips with the slots in the
side of the body.
3. Lift the front edge of the wire trivet to remove the
hose from its storage position and replace the
trivet. Check the “O” rings for any damage before
connecting hose. Connect the hose to the appliance
by pushing the hose tting into the inlet connector,
then tightening the knurled nut until hand tight and
rm.
4. Check that the control valves for the burners are
turned OFF (clockwise for off).
5. Connect the hose to the cylinder and use a spanner
to tighten rmly.
6. Ensure the chrome wire lid latches or feet are in
position to maintain clearance between the appliance
and the support surface and for good airow and
correct operation.
This appliance should only be operated on a hard,
at, level surface.
a. The appliance area must be kept clear and
free of combustible materials, gasoline and other
ammable vapours and liquids.
b. Gas orices and burner must be kept clear of dirt
and cobwebs. Flow of combustion and
ventilation air through the perforated portions of
the appliance must not be obstructed.
c. Any cleaning agent used on the appliance should
be of a non-combustible and non-corrosive
nature.
7. Proper clearance from combustible materials must be
maintained at all times. The minimum clearances are
as follows:
Minimum Clearance from Combustibles:
Rear 600mm Side 600mm Top 600mm
Combustible materials are considered to be wood,
compressed paper, plant bres, plastic, plexiglas or other
materials capable of being ignited and burned.
Such materials shall be considered combustible even
though ame proofed, re-retardant treated or plastered.
Additional clearance may be required for glass, painted
surfaces and other materials which may be damaged by
radiant or convection heat.
LIGHTING & BURNER ADJUSTMENT
1. Open the cylinder control valve about one full turn
ensuring that all the control knobs on the stove are
turned OFF at this point. DO NOT ATTEMPT TO
LIGHT THE STOVE!
2. To check for leaks on all connections use a solution
of soapy water (dish washing liquid and water is
ne). Brush it on or use a spray bottle. Ensure the
connections have a good coating.
3. If the connection is leaking, bubbles will start to grow
in the soapy solution. If this happens shut off the gas
supply at the cylinder.
4. Tighten the connections using a spanner then repeat
steps 1-2. The connection is gas tight when no
bubbles grow around the gas connection.
5. Each burner can be operated independently by
turning the control valve on (rotating the knob anti-
clockwise about one turn) and applying a lighted
match to the burner. The ame can be regulated by
opening or closing the valve.
6. If the burner fails to ignite after several attempts,
turn the control knob to OFF and wait a few minutes
before attempting re-ignition.
7. Turn the control knob anti-clockwise to increase the
ame, or clock-wise to decrease the ame.
8. IMPORTANT: When turning the stove off at
completion of use, the gas supply should be rst
turned off at the cylinder, and all gas in the hose burnt
away before closing the valves on the stove. Leaving
the gas in the hose can cause injector blockage.
Note: If re-ignition if necessary while the stove is still
hot, you must wait for a minimum of 5 minutes before
commencing to re-ignite (this allows accumulated gas
fumes to clear).
REGULAR MAINTENANCE
Clean the body of your appliance using a cotton cloth
soaked in soapy hot water. Never use abrasive or
ammable cleaning products. Use a soft brush to clean
the burner.
STORAGE
When the appliance is not used it must be
stored in a suitable area to protect it from any risk of
deterioration. Keep it in a well ventilated area and out of
reach of children.
HANDY HINTS
a. The hose connections, cylinder valve outlet
connection and appliance inlet connection should
be kept clean. If grit or dirt is present when the
connections are made, the rubber seals at each end
of the hose may be damaged.
b. To clear blocked injector wash in petrol or use
compressed air to blow out obstruction. Do not use
wires or prickers. If washing is unsuccessful, t new
injector.
c. Check for gas leaks with SOAPY WATER. DO NOT
USE A FLAME.
d. Ensure that the area in which the appliance is to be
used is well ventilated and DO NOT use as a space
heater in tent, caravan, etc.
e. Ensure the appliance is completely extinguished
before disconnecting from the cylinder.
f. DO NOT place the appliance closer than 60cm from
ceiling or ammable material.
g. Avoid moving the appliance during use as this can
cause large ames.
h. Allow the appliance to cool down after use before
touching the burners, trivet, windshields or folding up
for transportation.
WARNING
Be very careful when turning the burner down.
Visually check to ensure the ame does not go out.
INJECTOR REPLACEMENT
If the burner will not light the injector may be blocked.
1. Undo and remove the burner screw on the
underside of the body.
2. With a small shifter remove the injector from the gas
valve and either clean or replace it (refer to Handy
Hints).
3. Re-attach the burner.
SAFE APPLIANCE LOCATIONS
KNOB MARKINGS
INJECTOR
SPARE PARTS
Knob GMKN-2
Hose GMH3
O-Ring (Spindle) GMORN1
O-Ring (Cyl End) GMORN6
O-Ring (Stove End) GMORN4
Burner 85 1095HBNR
Jet 85 1095HJET
Gas Type Number of
Burners
Injector
Size Total BTU MJ/h
Total g/h Total Certificate
ULPG 2 0.20mm 20,850 BTU 22 MJ/h 436 g/h GMK10385
GAS CONSUMPTION

GENERAL INFORMATION
This appliance shall only be used in an above ground
open-air situation with natural ventilation, without stagnant
areas, where gas leakage and products of combustion are
rapidly dispersed by wind and natural convection.
Any enclosure in which the appliance is used shall
comply with the following:
An enclosure with walls on all sides, but at least one
permanent opening at ground level and no overhead
cover (see Example 1).
Within a partial enclosure that includes an overhead cover
and no more than two walls (see Example 2 & 3).
Within a partial enclosure that includes an overhead
cover and more than two walls, the following will
apply:
at least 25% of the total wall area is completely open,
and at least 30% of the remaining wall area is open and
unrestricted (see Example 4 & 5).
In the case of balconies, at least 20% of the total wall
area shall be and remain open and unrestricted.
DIAGRAMMATIC REPRESENTATIONS OF OUTDOOR AREAS
The following gures are diagrammatic representations of outdoor areas. Rectangular areas have been used in these
gures – the same principles apply to any other shaped area.
INSTRUCTIONS
Read these instructions for use carefully. Familiarise
yourself with the appliance before connecting it to its gas
container. Keep these instructions for future reference.
1. Remove appliance from carton and remove any
transit protection material.
2. Open the lid to the vertical position, fold out the
windshield and engage the clips with the slots in the
side of the body.
3. Lift the front edge of the wire trivet to remove the
hose from its storage position and replace the
trivet. Check the “O” rings for any damage before
connecting hose. Connect the hose to the appliance
by pushing the hose tting into the inlet connector,
then tightening the knurled nut until hand tight and
rm.
4. Check that the control valves for the burners are
turned OFF (clockwise for off).
5. Connect the hose to the cylinder and use a spanner
to tighten rmly.
6. Ensure the chrome wire lid latches or feet are in
position to maintain clearance between the appliance
and the support surface and for good airow and
correct operation.
This appliance should only be operated on a hard,
at, level surface.
a. The appliance area must be kept clear and
free of combustible materials, gasoline and other
ammable vapours and liquids.
b. Gas orices and burner must be kept clear of dirt
and cobwebs. Flow of combustion and
ventilation air through the perforated portions of
the appliance must not be obstructed.
c. Any cleaning agent used on the appliance should
be of a non-combustible and non-corrosive
nature.
7. Proper clearance from combustible materials must be
maintained at all times. The minimum clearances are
as follows:
Minimum Clearance from Combustibles:
Rear 600mm Side 600mm Top 600mm
Combustible materials are considered to be wood,
compressed paper, plant bres, plastic, plexiglas or other
materials capable of being ignited and burned.
Such materials shall be considered combustible even
though ame proofed, re-retardant treated or plastered.
Additional clearance may be required for glass, painted
surfaces and other materials which may be damaged by
radiant or convection heat.
LIGHTING & BURNER ADJUSTMENT
1. Open the cylinder control valve about one full turn
ensuring that all the control knobs on the stove are
turned OFF at this point. DO NOT ATTEMPT TO
LIGHT THE STOVE!
2. To check for leaks on all connections use a solution
of soapy water (dish washing liquid and water is
ne). Brush it on or use a spray bottle. Ensure the
connections have a good coating.
3. If the connection is leaking, bubbles will start to grow
in the soapy solution. If this happens shut off the gas
supply at the cylinder.
4. Tighten the connections using a spanner then repeat
steps 1-2. The connection is gas tight when no
bubbles grow around the gas connection.
5. Each burner can be operated independently by
turning the control valve on (rotating the knob anti-
clockwise about one turn) and applying a lighted
match to the burner. The ame can be regulated by
opening or closing the valve.
6. If the burner fails to ignite after several attempts,
turn the control knob to OFF and wait a few minutes
before attempting re-ignition.
7. Turn the control knob anti-clockwise to increase the
ame, or clock-wise to decrease the ame.
8. IMPORTANT: When turning the stove off at
completion of use, the gas supply should be rst
turned off at the cylinder, and all gas in the hose burnt
away before closing the valves on the stove. Leaving
the gas in the hose can cause injector blockage.
Note: If re-ignition if necessary while the stove is still
hot, you must wait for a minimum of 5 minutes before
commencing to re-ignite (this allows accumulated gas
fumes to clear).
REGULAR MAINTENANCE
Clean the body of your appliance using a cotton cloth
soaked in soapy hot water. Never use abrasive or
ammable cleaning products. Use a soft brush to clean
the burner.
STORAGE
When the appliance is not used it must be
stored in a suitable area to protect it from any risk of
deterioration. Keep it in a well ventilated area and out of
reach of children.
HANDY HINTS
a. The hose connections, cylinder valve outlet
connection and appliance inlet connection should
be kept clean. If grit or dirt is present when the
connections are made, the rubber seals at each end
of the hose may be damaged.
b. To clear blocked injector wash in petrol or use
compressed air to blow out obstruction. Do not use
wires or prickers. If washing is unsuccessful, t new
injector.
c. Check for gas leaks with SOAPY WATER. DO NOT
USE A FLAME.
d. Ensure that the area in which the appliance is to be
used is well ventilated and DO NOT use as a space
heater in tent, caravan, etc.
e. Ensure the appliance is completely extinguished
before disconnecting from the cylinder.
f. DO NOT place the appliance closer than 60cm from
ceiling or ammable material.
g. Avoid moving the appliance during use as this can
cause large ames.
h. Allow the appliance to cool down after use before
touching the burners, trivet, windshields or folding up
for transportation.
WARNING
Be very careful when turning the burner down.
Visually check to ensure the ame does not go out.
INJECTOR REPLACEMENT
If the burner will not light the injector may be blocked.
1. Undo and remove the burner screw on the
underside of the body.
2. With a small shifter remove the injector from the gas
valve and either clean or replace it (refer to Handy
Hints).
3. Re-attach the burner.
SAFE APPLIANCE LOCATIONS
KNOB MARKINGS
INJECTOR
SPARE PARTS
Knob GMKN-2
Hose GMH3
O-Ring (Spindle) GMORN1
O-Ring (Cyl End) GMORN6
O-Ring (Stove End) GMORN4
Burner 85 1095HBNR
Jet 85 1095HJET
Gas Type Number of
Burners
Injector
Size Total BTU MJ/h
Total g/h Total Certificate
ULPG 2 0.20mm 20,850 BTU 22 MJ/h 436 g/h GMK10385
GAS CONSUMPTION

IMPORTANT
Read these instructions for use carefully.
Familiarise yourself with the appliance before
connecting it to its gas container. Keep these
instructions for future reference.
ONLY USE IN WELL-VENTILATED AREAS.
CARBON MONOXIDE HAZARD - USING THIS
APPLIANCE IN AN ENCLOSED SPACE MAY CAUSE
DEATH. DO NOT USE IN CARAVANS, TENTS,
MARINE CRAFT, CARS, MOBILE HOMES OR
SIMILAR LOCATIONS.
• Do not modify this appliance.
• Check that seals between the appliance and the
gas container are in place and in good condition
before connecting the gas container.
• Do not use the appliance if it has damaged or worn
seals.
• Do not use this appliance if it is leaking, damaged
or does not operate properly.
• This appliance must only be serviced by an
authorized person.
• The openings at the base of the burner provide air
for combustion, they should never be obstructed. If
the ame becomes signicantly orange check these
openings for a blockage.
• If the appliance cannot be adjusted to perform
correctly it should not be used until serviced or
repaired.
• To check that the gas container is lled, when
shaken a sloshing sound will be heard.
CAUTION: Accessible parts may be very hot. Keep
young children away.
USE OUTDOORS ONLY.
PROPANE/UNIVERSAL LPG PRODUCT
This appliance shall only be used with a propane gas
cylinder certied to AS2469 or Universal L.P.G.
IT MAY BE HAZARDOUS TO ATTEMPT TO FIT
OTHER TYPES OF GAS CONTAINERS.
Gas cylinders should be stored outdoors in a well
ventilated area out of reach of children. Any indoor
storage shall comply with AS/NZS 1596.
Only use the hose assembly as supplied with this
appliance for connection to the cylinder - DO NOT USE
ADAPTORS.
Maximum hose length is 100cm.
After use, turn the gas cylinder valve off, wait for the
ame to go out, and then turn the appliance control
valve(s) off.
Avoid twisting or kinking the exible hose.
If there is a leak on your appliance (smell of gas)
immediately attempt to turn off the cylinder valve.
Remove the appliance to a well-ventilated location
away from any ignition source. Check for leaks using
soapy water. Do not try to detect leaks using a ame.
Model No. CS1095
Fine burner adjustment controls
Durable powder coated nish
Removable cooking trivet for easy cleaning
Units folds to a compact size with handle
Windshields on three sides
Complete with hose to suit 3/8” BSP-LH cylinders
For outdoor use only
Gas certied to Australian and New Zealand Standards
Gasmate®is a registered trademark of: Sitro Group Australia Pty Ltd www.gasmate.com.au
Aber Holdings Ltd - N.Z www.gasmate.co.nz
Important: Retain these instructions for future use.
03962 09/19
For any queries or assistance call
Customer Service
(Australia Only)
1300 174 876
Hours of operation:
Monday to Friday 8.00am - 5.00pm EST
Do not return to place of purchase.
Keep your purchase receipt, this will be required to
make any claims under the 12 month warranty.
Gasmate®is a registered trademark of:
Sitro Group Australia Pty Ltd www.gasmate.com.au
Aber Holdings Ltd, N.Z www.gasmate.co.nz

IMPORTANT
Read these instructions for use carefully.
Familiarise yourself with the appliance before
connecting it to its gas container. Keep these
instructions for future reference.
ONLY USE IN WELL-VENTILATED AREAS.
CARBON MONOXIDE HAZARD - USING THIS
APPLIANCE IN AN ENCLOSED SPACE MAY CAUSE
DEATH. DO NOT USE IN CARAVANS, TENTS,
MARINE CRAFT, CARS, MOBILE HOMES OR
SIMILAR LOCATIONS.
• Do not modify this appliance.
• Check that seals between the appliance and the
gas container are in place and in good condition
before connecting the gas container.
• Do not use the appliance if it has damaged or worn
seals.
• Do not use this appliance if it is leaking, damaged
or does not operate properly.
• This appliance must only be serviced by an
authorized person.
• The openings at the base of the burner provide air
for combustion, they should never be obstructed. If
the ame becomes signicantly orange check these
openings for a blockage.
• If the appliance cannot be adjusted to perform
correctly it should not be used until serviced or
repaired.
• To check that the gas container is lled, when
shaken a sloshing sound will be heard.
CAUTION: Accessible parts may be very hot. Keep
young children away.
USE OUTDOORS ONLY.
PROPANE/UNIVERSAL LPG PRODUCT
This appliance shall only be used with a propane gas
cylinder certied to AS2469 or Universal L.P.G.
IT MAY BE HAZARDOUS TO ATTEMPT TO FIT
OTHER TYPES OF GAS CONTAINERS.
Gas cylinders should be stored outdoors in a well
ventilated area out of reach of children. Any indoor
storage shall comply with AS/NZS 1596.
Only use the hose assembly as supplied with this
appliance for connection to the cylinder - DO NOT USE
ADAPTORS.
Maximum hose length is 100cm.
After use, turn the gas cylinder valve off, wait for the
ame to go out, and then turn the appliance control
valve(s) off.
Avoid twisting or kinking the exible hose.
If there is a leak on your appliance (smell of gas)
immediately attempt to turn off the cylinder valve.
Remove the appliance to a well-ventilated location
away from any ignition source. Check for leaks using
soapy water. Do not try to detect leaks using a ame.
Model No. CS1095
Fine burner adjustment controls
Durable powder coated nish
Removable cooking trivet for easy cleaning
Units folds to a compact size with handle
Windshields on three sides
Complete with hose to suit 3/8” BSP-LH cylinders
For outdoor use only
Gas certied to Australian and New Zealand Standards
Gasmate®is a registered trademark of: Sitro Group Australia Pty Ltd www.gasmate.com.au
Aber Holdings Ltd - N.Z www.gasmate.co.nz
Important: Retain these instructions for future use.
03962 09/19
For any queries or assistance call
Customer Service
(Australia Only)
1300 174 876
Hours of operation:
Monday to Friday 8.00am - 5.00pm EST
Do not return to place of purchase.
Keep your purchase receipt, this will be required to
make any claims under the 12 month warranty.
Gasmate®is a registered trademark of:
Sitro Group Australia Pty Ltd www.gasmate.com.au
Aber Holdings Ltd, N.Z www.gasmate.co.nz
Table of contents
Other Gasmate Stove manuals

Gasmate
Gasmate CS601 User manual

Gasmate
Gasmate PC1090 User manual

Gasmate
Gasmate CS405 User manual

Gasmate
Gasmate TRAVELMATE II User manual

Gasmate
Gasmate CS601K1 User manual

Gasmate
Gasmate TRAVELMATE II CS403 User manual

Gasmate
Gasmate PC2090 User manual

Gasmate
Gasmate CS170Y User manual

Gasmate
Gasmate CS400 User manual

Gasmate
Gasmate CS751 User manual
Popular Stove manuals by other brands

Godin
Godin 3465 manual

EASYSTEAM
EASYSTEAM ANAPA Installation and Maintenance

Axley
Axley 769-019 operating instructions

Blaze King
Blaze King KWC-1400 Owner installation and user manual

Dunsley Heat
Dunsley Heat YORKSHIRE 4022250 Installation and operating instructions

Dovre
Dovre 250 Installation instructions and operating manual