GCS ZA1501IN-5 User manual

Federal Communications Commission Statement
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) This device
must accept any interference received, including interference that may cause undesired
operation.
FCC Caution
“the user that changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.”
FCC Statement in User’s Manual (for calss B) FCC Section 15.105 “Federal
Communications Commission (FCC) Statement”
This equipment has been tested and found to comply with the limits for a class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Limited Warranty
GCS Guarantees that every wireless Arrival Sensor is free from physical defects in
material and workmanship under normal use for one year from the date of purchase. If
the product proves defective during this one-year warranty period, Vision will replace it
free of charge. GCS does not issue any refunds. This warranty is extended to the original
end user purchase only and is not transferable. This warranty does not apply to: (1)
damage to units caused by accident, dropping or abuse in handling, or any negligent use;
(2) units which have been subject to unauthorized repair, taken apart, or otherwise
modified; (3) units not used in accordance with instruction; (4) damages exceeding the
cost of the product; (5) transit damage, initial installation costs, removal cost, or
reinstallation cost. For information on addtional devices, please visit us at www.gcs-st.com
Installation & Operation Manual
Arrival Sensor
ZA1501IN-5
ZA1501EU-5
ZA1501RU-5
ZA1501US-5
ZA1501IL-5
ZA1501KR-5
ZA1501HK-5
ZA1501JP-5
ZA1501BR-5
ZA1501-5
V0
1080128

Introduction
Thanks for choosing the Vision’s wireless Arrival Sensor of the home security device. This
sensor is a Z-Wave™ PLUS enabled device (interoperable, two-way RF mesh networking
technology) and is fully compatible with any Z-Wave™ enabled network and it’s security
framework. Every mains powered Z-Wave PLUS enabled device acts as a signal repeater and
multiple devices result in more possible transmission routes which helps eliminate “RF
dead-spots”
Z-Wave™ PLUS enabled devices displaying the Z-Wave™ PLUS logo can also be used with it
regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave™
PLUS enabled networks. This sensor assigns everyone an unique ID then you could take care
of your family to send you any instant notification when they are coming home or leaving home,
also you could interact some specific scenarios with specific persons When the device is
secure included into Z-Wave network, above communication will be encrypted. ARRIVAL
SENSOR supports SECURITY S0 / SECURITY S2 UNAUTHENTICATED / SECURITY S2
AUTHENTICATED.
Product Description and Specification
Specification:
Package
Content:
Protocol: Z-Wave™ (ZM5101)
Frequency Range:
865.22MHz (ZA1501IN-5)
868.42MHz (ZA1501EU-5)
869.00MHz (ZA1501RU-5)
908.42MHz (ZA1501US-5)
916.00MHz (ZA1501IL-5)
919~923MHz (ZA1501KR-5)
919.80MHz (ZA1501HK-5)
922~926MHz (ZA1501JP-5)
921.42MHz (ZA1501BR-5)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -10°C~ 60°C (14°F ~140°F)
1pc
1pc
1pc
Arrival sensor
Micro USB Cable
Operation manual
Z-Wave Command Classes:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Z-Wave S2 Support Command Class:
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_WAKE_UP_V2
Notification V8 Type
TYPE EVENT
Notification
Type
System (0x09) Heartbeat (0x05)
Clock (0x0B) Timer Ended (0x02)
(Table 1)
V1 Alarm:
TYPE VALUE
V1 Alarm
Type
0x09 0xFF
0x0B 0x00
(Table 2)
Configuration Command Class:
Byte Value
Parameter 1
1 1 ~ 127 (unsigned decimal) Seconds
(default: 2 (=16seconds x 2))
(Table 3)
(P.S.: This is the definition how long ZA1501-5 will contact
Gateway for having a synchronic information. The basic
interval time is 16 seconds, the synchronic time will be the
basic interval time by Parameter 1’s value.)
-1-
-2-

Operation
Notice: If you are installing the entire Z-Wave™ system for the first time, please
refer to the installation guide of Z-Wave™ Interface Controller and full charging the
arrival sensor before using..
LED Status:
- Charging: Red LED on.
- Charge Completely: Green LED on.
- Not Included: Red LED flashing.
1. For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into
“inclusion” mode, and following its instruction to add the arrival sensor to your
controller. To get in the “inclusion” mode, press the Program Switch of arrival sensor
then the device will send a signal to be included (or excluded) to/from the network;
otherwise, arrival sensor will go to sleep after 30 seconds.
For “Exclusion” from (removing from) a network: Put the Z-Wave™ Interface
Controller into “exclusion” mode, and following its instruction to delete the arrival
sensor from your controller. Press the Program Switch of arrival sensor to be
excluded.
Note: All user and network settings will be cleared and the device reset to factory
defaults when the device is excluded.
2. Trigger Response:
- The sensor will send Notification Report (refer to Table 1 & 2) if it has been moved.
- The sensor will send Notification Report (refer to Table 1 & 2) and exceed
the preset detecting time (refer to Table 3).
3. Wake Up Notification:
Press the program switch, arrival sensor will be “Wake Up Mode” for receiving all the
command class from controller. The arrival sensor will go to sleep mode or it will wait
10 seconds then go sleep mode. It will proceed all the commands after sending the
“Wake Up Notification”
4. Auto Wake Up:
Use “Wake Up” command to set up the awaking time and send the wake up
notification to controller. User can use command to change the auto wake up from
10 minutes to 1 week, Interval increment is 3 minutes. (Default Value: 30 minutes.)
5. Battery Capacity Detection:
Use “Battery Get” command to have the battery capacity back in %. It will detect the
battery capacity automatically. Low Battery Auto Report (low battery is set as 3.2+/-0.1
Voltage).
6. Association:
* Support one group with 1 node.
* Group 1 = Lifeline
7. Support Explorer Frame Function
8. All the rest commands depend on Z-Wave standard
9. Factory Default Reset: Long press the program switch up to 10 seconds to send the
“Device Reset Locally Notification” command and reset to the factory default.
(Remark: This is to be used only in the case of primary controller being inoperable or
otherwise unavailable.)
10. Support OTA Firmware update from controller. Please refer to your controller manual.
Once OTA function success, we recommend you exclusive the device & inclusive
again before use the device.
11. Support SECURITY S0, SECURITY S2 UNAUTHENTICATED & SECURITY S2
AUTHENTICATED.
12. Support SmartStart, please scan the QR Code from ARRIVAL SENSOR for SmartStart.
QR code and PIN is located on the device, also there is a Full DSK string on the
enclosed DSK card. Please keep DSK card carefully for future inclusion needed.
(P.S.: Z-Wave SmartStart aims to shift the tasks related to inclusion of an end device
into a Z-Wave network away from the end device itself, and towards the more
user-friendly interface of the gateway.)
13. A Security Enabled Z-Wave Controller must be used to fully utilize the products.
-3-
-4-
This manual suits for next models
8