Gemco 2500 Series User manual

High-Speed Programmable Limit Switch
2500
High-SpeedPLS
Series956
ABSOLUTEPROCESSCONTROL
KNOWWHEREYOUARE...REGARDLESS
INSTALLATION MANUAL
2500Series

2
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
Preface
This manual is for the Installation
and Maintenance of the Gemco 2500
Programmable Limit Switch.
AMETEK has checked the accuracy of
this manual at the time it was printed.
Any comments you may have for
the improvement of this manual are
welcomed.
AMETEK reserves the right to revise
and redistribute the entire contents
or selected pages of this manual.All
rights to the contents of this manual are
reserved byAMETEK.
WARNING: Caution must be
taken when adjusting limit
outputs!
Disconnect power before servicing.
The Gemco 2500 PLS contains no
serviceable components other than
relays and fuses. Consult factory for
repair or replacement.

3
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
Contents
Chapter 1: Introduction.............................4
1.1 Mechanical Cams..................................5
1.2 Description.............................................5
1.3 Standard Features.................................7
Chapter 2: Hardware Overview................9
2.1 PLS Module...........................................9
2.2 Remote Operator Interface...................11
2.3 Expansion Modules..............................11
2.4 ResolverAssembly..............................12
2.5 Status Display/Programming Keys......14
2.6 Dimension Drawings............................16
Chapter 3: Mounting and Wiring............20
3.1 Mechanical Installation........................20
3.2 Electrical Installation............................21
3.3 Wiring Instructions...............................21
Chapter 4: Programming........................30
4.1 Main Controller Keypad.......................30
4.2 Programming Keys Defined.................31
4.3 Before You Start..................................32
4.4 Menu Tree...........................................33
4.5 User and Supervisor ModeAccess.....33
Chapter 5: Global Parameters................35
5.1 Quick Start...........................................35
5.2 Initialize System...................................36
5.3 Expansion Boards...............................37
5.4 Lockout Functions...............................38
5.5 Scale Factor........................................39
5.6 Customize Decimal Pt.
(Decimal Location)...............................40
5.7 Electronic Offset..................................41
5.8 Motion Detect......................................42
5.9 Enable Brake Input..............................43
5.10 Brake Monitor....................................43
5.11 Set Fault Clear Option.......................45
5.12 Customize Display.............................46
5.13 Define Title Screen............................47
5.14 Label Outputs....................................48
5.15 Label Inputs.......................................49
5.16 Define User Password.......................50
5.17 Define Supervisor Password.............51
5.18 Software Version...............................52
Chapter 6: Limit Switch Outputs............53
6.1 Setpoint Data.......................................54
Chapter 7: Multiple Program..................56
7.1 NamingAProgram..............................57
7.2 EditingAProgram................................58
7.3 CopyingAProgram..............................59
7.4AccessingAProgram...........................60
7.5 Initialize Program.................................61
Chapter 8: Linear Speed Compensation 62
8.1 Linear Speed Compensation...............64
8.2 Minimum Speed Disable......................65
Chapter 9: Time Based Outputs.............66
Chapter 10: Inputs...................................67
10.1 Input Configuration............................71
10.2 Input Configuration for No Input........73
10.3 Input Configuration for
Reset to Preset Continuous...............74
10.4 Input Configuration for
Reset to Preset Single.......................75
10.5 Input Configuration for
Output Enable One Shot...................76
10.6 Input Configuration for
Output Enable Level..........................77
10.7 Enable Brake Input............................78
Chapter 11: Die Protection Inputs..........79
11.1Applications for Die Protection Inputs 79
11.2 Input Configuration for
Die Protect Momentary......................82
11.3 Input Configuration for
Die Protect Maintain..........................83
11.4 Input Configuration for
Die Protect Partial..............................84
Chapter 12: Faults...................................85
AppendixA: Ordering Information ........89
Appendix B: Specifications....................90
B.1: Main Controller Specifications............90
B.2: Expansion Module Specifications......91
B.3: Remote Operator Interface
Specifications....................................91

4
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
Chapter 1: Introduction
The 2500 PLS is a high speed resolver
based Programmable Limit Switch that
monitors rotary machine position and
provides discrete limit switch outputs.
These outputs are updated at a much
faster rate than can be accomplished
using any conventional PLC.
The single turn resolver is usually
coupled to the machine shaft at a 1:1
ratio so that one resolver shaft rotation
corresponds to one machine cycle.
As the resolver rotates it generates a
ratiometric analog signal representing an
absolute rotary position. The ratiometric
signal is converted to a digital signal
at the 2500 PLS. Resolvers have no
brushes, contacts, or any frictional parts
to wear out.
As the resolver passes through the user
programmed dwell settings, the 2500
PLS turns electrical switches, known as
outputs, on and off. Outputs can energize
solenoids, relays, or solid-state circuitry
to control external devices. Because the
2500 PLS is completely electronic and
has no frictional parts, it offers several
advantages over mechanical cam
switches:
• Long life with no parts to wear out.
• Easy to use menu driven displays.
• Setpoints can be adjusted instantly
from the controller.
•Adjustments can be made while the
machine is running.
• Programmable inputs allow for complex
output functions that are impossible
with mechanical cams.
• Operating speeds up to 2,000 RPM.

5
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
1.1 Mechanical Cams
The 2500 Programmable Limit Switch
electronically simulates mechanical cam
switches.Amechanical cam consists
of a mechanical limit switch and a roller
follower whose roller follower rides on
the cam assembly as shown in Figure 1.
The camshaft is driven by the machine
at a 1:1 ratio so that the cam limit switch
turns ON and OFF at specific positions
in the machine cycle. Cam limit switches
have the following disadvantages:
• The roller follower and limit switches
wear out.
• The machine must be stopped during
adjustment.
• On/off patterns are limited to typically
one on and one off per cam. Multiple
on and off points require custom cams.
• The mechanical cam switches are
typically not installed in an easily
accessible location.
• They cannot run at high speeds
because of contact bounce and
mechanical wear.
1.2 Description
The 2500 is a family of PLS’s that
offer unparalleled flexibility. The main
controller is a resolver-based controller
that consists of 8 input and 8 output
relays, one fault check output relay and
one optional brake monitor input relay.
The optional expansion module will
provide 8 additional inputs and outputs
per module. Up to 7 expansion modules
can be driven by the controller for a total
of 64 inputs and 64 outputs.
The 2500 PLS uses a unique, easy to
understand programming sequence. The
traditional number buttons have been
replaced with a rotary knob and the main
controller has a 2x24 vacuum fluorescent
display along with 4 pushbutton keys for
programming.
The keys have been defined as MENU,
ÕÖ and . The rotary knob scrolls
you easily through the menu drive
alphanumeric display. On-line help
screens have been added to aid in the
setup and troubleshooting of the unit.
System parameters are entered through
a scrolling menu, which is accessed
through the main display. The rotary
knob is used to scroll through the
selections and the key is used to
select the menu item. The user can view
any system value without entering a
password. However, if the user wants to
change a value, a password is required.
All the parameters are password
protected. Once the password is entered,
the user will be allowed to edit any value
as long as the user does not return to the
main display and the program input is in
the correct state.
System data such as position, RPM, and
brake monitor status will be shown on the
main display. This data can be toggled
through using the rotary knob.
Figure 1-1:
1980 Rotating Cam Limit Switch

6
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
2500 Stand Alone Main Controller
Clawson, MI 48017 U.S.A.
NP0197900
R
ENTER
SCROLL
MENU
2500 SERIES PLS
• 8 Isolated DC Inputs and 8 Solid-StateAC or DC Outputs,
Expandable to 64 (in groups of 8) using 2500E Expansion
Modules
• Rotary Knob with Simple, Menu Driven Programming and Help
Menus
• Brake Monitor
• 2 x 24 Vacuum Fluorescent Display
• Panel Mountable
2500R Remote Operator Interface
Clawson, MI 48017 U.S.A.
NP0197900
R
ENTER
SCROLL
MENU
2500 SERIES PLS
• Keypad only, used with 2500C Blind Main Controller Units
• 2 x 24 Vacuum Fluorescent Display
• Panel Mountable, up to 25 feet from Main Controller
• Simple RJ45 Connections to Main Controller
• Rotary Knob, with Scrolling, Menu Driven Programming
2500C Blind Main Controller Units
w
SDEC
TR5
V
F4A 250V
V
SC
DE
TR5
w
F4A 250V
w
C
V
DE
S
TR5
F4A 250V
C
V
DE
S
TR5
w
F4A 250V
w
TR5
C
V
DE
S
F4A 250V
DE
SC
V
TR5
w
F4A 250V
w
C
V
DE
S
TR5
F4A 250V
C
V
DE
S
TR5
w
F4A 250V
INPUT STATUS
OUT6 OUT8OUT7OUT5OUT4
IN8IN7IN5 IN6IN4
OUT1 OUT2 OUT3BK IN
AC POWER
50/60 Hz
INTERNALLY FUSED
100-240 VAC
IN3IN2IN1
GND
L2
L1
2500CBXXXX
2500 SERIES PLS
SERIAL No. >>>>>> D/C >>>>
Clawson, MI 48017 U.S.A.
R
• 8 Isolated DC Inputs and 8 Solid-StateAC or DC Ouptuts,
Expandable to 64 (in groups of 8) using 2500E Expansion
Modules
• Brake Monitor
• Panel or DIN Rail Mountable
2500E Expansion Modules
w
SDEC
TR5
V
F4A 250V
V
SC
DE
TR5
w
F4A 250V
w
C
V
DE
S
TR5
F4A 250V
C
V
DE
S
TR5
w
F4A 250V
w
TR5
C
V
DE
S
F4A 250V
DE
SC
V
TR5
w
F4A 250V
w
C
V
DE
S
TR5
F4A 250V
C
V
DE
S
TR5
w
F4A 250V
IN4
INPUT STATUS
IN1 IN2 IN3 IN6IN5 IN7 IN8
INTERNALLY FUSED
L1
100-240 VAC
50/60 Hz
AC POWER
GND
L2
OUT4OUT1 OUT2 OUT3 OUT6OUT5 OUT7 OUT8
SERIAL No. >>>>>> D/C >>>>
2500EXXXXX
Clawson, MI 48017 U.S.A.
2500 SERIES PLS
R
• 8 Isolated DC Inputs and 8 Solid-StateAC or DC Outputs
• Panel or DIN Rail Mountable
• Up to 7 Expansions Modules can be Driven From the Main
Controller
• Simple Depluggable Connections
2500 PLS configurations include:

7
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
1.3 Standard Features
Scale Factor
The Scale Factor is the number of
increments that the PLS counts through
over one rotation of the resolver. For
example, a PLS with a Scale Factor of
360 will count from 0 to 359 over one
revolution.
Offset
The Offset feature is used to electronically
synchronize the PLS displayed position
with the actual machine position. Valid
values are 0 to (one less than the
programmed Scale Factor).
Supervisor Menu
Two levels of programming access are
provided: User and Supervisor. In the
Supervisor Menu, display screens can
be customized and outputs and functions
can be locked out. Each level can be
assigned a password that must be entered
to program the locked out functions. This
can provide key personnel the flexibility
they need while protecting settings against
accidental or unauthorized changes.
Onboard Help
Onboard Help is available from the
2500 PLS 2x24 alphanumeric vacuum
fluorescent display. Each programming
screen has easy to follow English
programming screens.
Multi-program
The Multi-program feature allows
the storage of multiple sets of output
sequences that are pre-programmed
based on various requirements of different
jobs. When jobs are changed, the new
program is simply called up from the
Interface or remote inputs and all outputs
and inputs are automatically set to the
new output sequences. The 2500 PLS is
capable of storing 15 different programs.
Program Name
The Program Name feature allows the
user to assign a name to each program.
Program Copy
The Program Copy feature copies all
parameters from one program to another.
This is useful when inputting data from
one program to another where only minor
changes are needed.
Brake Monitor
The Brake Monitor checks the stopping
time of the machine against a selected
preset stopping time in milliseconds.A
user defined output remains energized
when the stop time parameters are within
tolerance.An excessive stop time will
cause the relay to de-energize, which
could be used to stop further machine
operation.
Motion Detector
Aprogrammable Motion Detector output
will energize a user selected relay when
the transducer speed meets or exceeds
the user programmed RPM value.
Fault Check
The 2500 PLS offers an on-line Fault
Check which provides an automatic,
in-process mechanism to verify that all
major programmable limit switch functions
are operating properly. The fault check
output can be energized by activating
the fault check enable input. The output
is a mechanical relay, which remains
energized during normal operation.

8
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
Input
Each Input can be configured as either
a reset to preset input, an output
configuration enable input, or a die
protection input.
Output Enabler
The output enable input will enable the
setpoints for one revolution when the input
is activated in a programmed window. The
user can program the window.
Reset to Preset
The Reset to Preset feature allows the
user to reset a pre-defined output to any
preprogrammed position. This feature can
be used to compensate for mechanical
slippage. NOTE: Each output has its own
independent reset input.
Reset Single Shot
The Reset Single Shot feature allows the
user to reset a pre-defined output to any
pre-programmed position. However, with
this feature the output associated with
this input waits for the input signal before
it allows the output to fire. Once the input
is made, the output will only fire one time
and wait for the next input signal.
Die Protection
Die Protection is used in stamping
applications where it is necessary to
monitor a part as it is progressing through
the die. If the part is not detected in the
location, an output will signal the press to
stop.
Output Enable
Output Enable is used in conjunction with
an input. If the input is not seen within a
programmed range, the output associated
with that input will not fire. Output enables
are typically used in gluing applications
where if a product is not present, the
gluing output does not fire.
Setpoint Data
There are up to eight setpoint pairs
available per revolution for each output.
The user can add, delete, or change a
setpoint in the list. Valid setpoints range
from 0 to a value (one less than the
current scale factor). For example, if the
scale factor is set at 1000, then valid
setpoint values range from 0 to 999.
Timed Outputs
Time Based outputs are programmed
like standard outputs to turn on at a
specific resolver position and stay on for a
programmable amount of time.
Minimum Speed
The Minimum Speed Disable will disable
the selected outputs when the Disable
actual RPM falls below the minimum
speed programmed by the user. Valid
minimum speed values range from 0 to
2048.Avalue of zero will disable this
feature. The default value is zero.
Linear Speed
Linear Speed Compensation allows for
setpoints to be adjusted to compensate
for mechanical lag at higher speeds. Each
output can be programmed with its own
adjusted values. The user will program an
on offset and an off offset and the RPM
that is associated with that offset. The unit
will linearize the offset values and adjust
the setpoints for that output based on the
actual RPM value.
Software Version
The software version can be viewed
through the Software Version menu
item. The version number will follow our
standard numbering system with two
digits before the decimal indicating major
releases and the two digits after the
decimal indicating minor releases.

9
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
This section contains mechanical and
electrical information on the 2500 PLS
main controller, expansion modules,
remote operator interface, and resolver
assembly. For specifications, see
Appendix B.
2.1 PLS Module
The 2500 PLS module is an electronic
assembly that can be configured many
different ways.The three main parts are
described in Chapter 1. The following are
features found on the module:
•Arotary knob replaces the standard
number buttons.As the knob is
rotated, it helps guide you through the
programming process. Convenient help
screens guide you through the entire
programming process.
•A2 line x 24 character vacuum
fluorescent display indicates all PLS
functions.
• Eight depluggable solid-state output
relays are located on the back of the
controller. Each output has its own
input located on the opposite side of
the controller.
•An optional depluggable Brake monitor
input relay is located on the back of the
controller. This input can be used to
determine stopping time of the
machine.
• The auxiliary communication port
currently supports ModbusASCII
protocol.
• Resolver input terminals allow
connection to a Gemco resolver or
compatible equipment.
• Expansion ports allow for further
relay expansion. The main controller
is capable of driving 64 outputs and
inputs.
• Fault check.Amechanical relay output
is held closed as long as the PLS is
working properly. If the PLS resolver
circuitry or microprocessor fails, the
relay will open.
• Universal input power. The 2500 PLS
can operate over a wide input range,
100 - 240 VAC, 50/60 Hz.
Chapter 2: Hardware Overview

10
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
Clawson, MI 48017 U.S.A.
NP0197900
R
ENTER
SCROLL
MENU
2500 SERIES PLS
w
SDE C
TR5
V
F 4A 250V
V
SC
DE
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
w
TR5
C
V
DE
S
F 4A 250V
DE
SC
V
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
INPUT STATUS
IN8IN7IN5 IN6IN4
100-240 VAC
INTERNALLY FUSED
IN1
50/60 Hz
IN3IN2
AC POWER
GND
L2
L1
OUT4 OUT6OUT5 OUT7 OUT8OUT2 OUT3OUT1BK IN
Figure 2-1: 2500CF Main Controller
Figure 2-2: 2500CB Blind Main Controller
w
SDEC
TR5
V
F 4A 250V
V
SC
DE
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
D E
S
TR5
w
F 4A 250V
w
TR5
C
V
DE
S
F 4A 250V
DE
SC
V
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
EXPANSION OUT
INPUT STATUS
OUT6 OUT8OUT7OUT5OUT4
IN8IN7IN5 IN6IN4
OUT1 OUT2 OUT3BK IN
AC POWER
50/60 Hz
INTERNALLY FUSED
100-240 VAC
IN3IN2IN1
GND
L2
L1
2500CBXXXX
2500 SERIES PLS
SERIAL No. >>>>>> D/C >>>>
Clawson, MI 48017 U.S.A.
R

11
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
Clawson, MI 48017 U.S.A.
NP0197900
R
ENTER
SCROLL
MENU
2500 SERIES PLS
The Remote Operator Interface connects
to the main controller through an 8-pin
Ethernet cable commonly know as an
RJ45. Full duplex RS-485 is used to
communicate to the main controller. The
remote operator interface is made up of
a 2x24 vacuum fluorescent display, along
with four pushbutton keys and a rotary
knob for programming. The keys have
been defined as MENU,Õ,Öand . The
2500R Remote Operator Interface can
be used with the 2500CB main controller
unit. This allows a means of mounting the
main controller unit remotely.
2.2 Remote Operator Interface
Figure 2-3: 2500R Remote Operator Interface
2.3 Expansion Modules
The standard 2500 PLS is supplied with
8 inputs and 8 outputs. The system is
expandable to 64 inputs and 64 outputs
by adding the 2500E Expansion Module.
Each expansion module consists of 8
output modules and 8 inputs. These
solid-state outputs are an optically
isolated barrier between the PLS and the
field devices they control. These output
modules are also pluggable and either
AC or DC relays can be used.
• Panel mount or DIN rail mountable.
• Plug and play cable design.
• Pluggable output relays.
• No increase in update time regardless
of number of Expansion Modules.
• LED’s are located next to each input
and output. These LED’s specify the
state of each input and output.

12
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
Stator 1 Voltage
Stator 2 Voltage
90 180 270 360
Ratiometric conversion of the
two secondary coil voltages
provides absolute position data,
and factors out EMI.
w
SDEC
TR5
V
F 4A 250V
V
SC
DE
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
w
TR5
C
V
DE
S
F 4A 250V
DE
SC
V
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
IN4
INPUT STATUS
IN1 IN2 IN3 IN6IN5 IN7 IN8
INTERNALLY FUSED
L1
100-240 VAC
50/60 Hz
AC POWER
GND
L2
OUT4OUT1 OUT2 OUT3 OUT6OUT5 OUT7 OUT8
EXPANSION OUT
SERIAL No. >>>>>> D/C >>>>
2500EXXXXX
Clawson, MI 48017 U.S.A.
2500 SERIES PLS
R
2.4 Resolver Assembly
The resolver assembly consists of a
highly accurate and repeatable brushless
resolver, housed in an industrial-grade
enclosure. Rotary shaft position is
calculated from two analog signals that
vary as a function of the angular rotation
of the input shaft.
The resolver works on the same principle
as a rotary transformer to couple power
into the rotor. The resolver consists of
a two-phase stator and a single-phase
rotor. Each stator is positioned 90º
apart from each other. The two stators
continually provide two different output
voltages. Using these two outputs, the
PLS performs a ratiometric conversion
which factors out electro-magnetic
interference (EMI) and provides an
absolute position. See Figure 2-5.
This results in a highly accurate and
repeatable unit with excellent reliability
and infinite resolution.
The resolver assembly is contained in a
rugged NEMA4 enclosure with a plug-in
connector. The input shaft is a 3/4 inch
diameter and is made of stainless steel. It
is mounted in sealed ball bearings with a
radial load rating of 150 lbs. This results
in the most rugged duty transducer
available for industrial applications. The
operating temperature range is -40º C
to 125º C. See Figure 2-7 or 2-8 for the
resolver dimensions.
Figure 2-4: 2500E Expansion Module
Figure 2-5: Voltages of Stator Coils

13
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
1.42
2.25
1.08
.7475
.7490
DIA.
.75
1.38
.62
2.50
8.50
8.00
2.12
5.50
4.25
KEY
#606WOODRUFF
.38
(52.58)
8.88
w/ ST.
CONN.
2.50
3.74
2 PLACES
.44 (11.18) DIA. MOUNTING HOLES
8.00 w/
R.A. CONN.
(139.70)
(107.95)
(53.85)
(15.75)
(63.50)
(203.20)
(215.90)
(225.55)
(203.20)
(35.05)
(19.05)
(36.07)
(27.43)
(57.15)
(63.50)
(95.00)
2.07
(9.65)
(19.02)
(18.99)
(COSINE)
YELLOW/WHITE
RED/WHITE
2500 PROGRAMMABLE LIMIT SWITCH
TO TERMINALS OF GEMCO
RESOLVER CABLE
SD0508200LX TRANSDUCER
RESOLVER
BLACK
GREEN
BLACK
ALPHA CABLE 6053
COLOR CODE
R2
S4
S2
S1
S3 WHITE
BLACK
R1 RED
S1
STATOR
B
F
E
D
C
A
S4 S2
(SINE)
STATOR
ROTOR
R1 R2
S3
BLACK
YELLOW RESOLVER COLOR CODE
RESOLVER HOUSING
JUMPER INSIDE
BLUE
RED
BCD
G
F
A
E
YELLOW
BLUE
RED
BLACK
WHITE
E
F
D
C
RED/WHITE
YELLOW B
A
RESOLVER
Figure 2-6: Reslover Wiring
Figure 2-7: 1986 “A” Style Brushless Resolver
NOTE: Other Gemco resolver assemblies are available. Contact factory for details.

14
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
(TOTAL CLEARANCEOF5.5"
REQUIREDFORREMOVAL
OFMATINGCONNECTOR)
[ ] = DIMENSIONS IN MILLIMETERS
CONNECTOR: MS3102E16S-1P
1/4-20UNC-2B
.50 [12.7]DEEP
(8 PLACES)
SEE KEYWAY
SPECIFICATIONS
1.25 [31.8]
.150 [3.8]
1.500
[38.1]
.500
[12.7]
3.250
[82.6]
4.87
[123.7]
.750
[19.1]
2.500
[63.5]
2.000
[50.8]
1.000
[25.4]
.250 [6.4]
.250
[6.4]
2.000
[50.8]
.673[17.1]
1.180
[30.0]
.6247
.6237[15.87]
[15.84]
Side mount
connector
Rear mount
connector
.673
[17.1]
2.50
[63.5]
Clawson, MI 48017 U.S.A.
NP0197900
R
ENTER
SCROLL
MENU
2500 SERIES PLS
Shift Keys:
Moves cursor right
or left.
Menu Key:
Used to access menu driven
display.
2 x 24 Alpha Numeric:
Vacuum Fluorescent Display.
POS 12345
RPM 2000
Rotary Knob:
The Rotary knob is used to
scroll and move through the
menu driven displays.
Enter Key:
Enter must be pressed
to enter a value.
Figure 2-8: 1986 “F” Style Brushless Resolver
The 2500 PLS has a 2 line by 24
character vacuum fluorescent display
(VFD), four programming buttons
and a rotary knob. The VFD provides
programming and status information.
The programming keys and rotary knob
are used to program functions and
perform basic operations.
Figure 2-9: Main Controller (Front View)
2.5 Status Display/Programming Keys

15
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
Incoming AC Power
Input Status LED’s
Output Status LED’s
Relay Output Fuse
Output Relays AC or DC:
Refer to part number
Red = DC relays
Black = AC relays
Optional Brake Monitor
Input Relay
w
SDEC
TR5
V
F 4A 250V
V
SC
DE
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
w
TR5
C
V
DE
S
F 4A 250V
DE
SC
V
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
IN8IN7IN5 IN6IN4
100-240 VAC
INTERNALLY FUSED
IN1
50/60 Hz
IN3IN2
AC POWER
GND
L2
L1
OUT4 OUT6OUT5 OUT7 OUT8OUT2 OUT3OUT1BK IN
SERIAL No. >>>>>> D/C >>>>
Clawson, MI 48017 U.S.A.
2500 SERIES PLS
2500CFXXXX
R
INPUT STATUS
Figure 2-10: Main Controller (Rear View)
The scrolling menu is accessed through
the main display by pressing the MENU
button. The rotary knob is used to scroll
through the selections and the key is
used to select the menu item.
Any system value can be viewed without
entering a password. However, if the
user wants to change a value he must
enter a password into the system.All
the parameters are password protected.
Once the password is entered, the user
will be allowed to edit any value as long
as the user does not return to the main
display and the program input is in the
correct state. On-board help is offered for
each menu item.
System data such as position, RPM, and
brake monitor status will be shown on the
main display.

16
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
6.31
7.50
4.73
.54
.13 3.32
3.98
4.50
1.50
5.88.22
.66
6.19
5.31.50
.18 (4 PLACES)
5.88
.22 5.43
6.31 4.50
.90
PANEL CUT OUT
DIMENSIONS #8-32 UNC-2B
(4 PLACES)
Clawson, MI 48017 U.S.A.
NP0197900
R
ENTER
SCROLL
MENU
2500 SERIES PLS
w
SDEC
TR5
V
F 4A 250V
V
SC
DE
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
w
TR5
C
V
DE
S
F 4A 250V
DE
SC
V
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
IN8IN7IN5 IN6IN4
100-240 VAC
INTERNALLY FUSED
IN1
50/60 Hz
IN3IN2
AC POWER
GND
L2
L1
OUT4 OUT6OUT5 OUT7 OUT8OUT2 OUT3OUT1BK IN
SERIAL No. >>>>>> D/C >>>>
Clawson, MI 48017 U.S.A.
2500 SERIES PLS
2500CFXXXX
R
INPUT STATUS
2.6 Dimension Drawings
Figure 2-11: 2500CF Main Controller Dimensions

17
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
w
SDE C
TR5
V
F 4A 250V
V
SC
DE
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
w
TR5
C
V
DE
S
F 4A 250V
DE
SC
V
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
EXPANSION OUT
INPUT STATUS
OUT6 OUT8OUT7OUT5OUT4
IN8IN7IN5 IN6IN4
OUT1 OUT2 OUT3BK IN
AC POWER
50/60 Hz
INTERNALLY FUSED
100-240 VAC
IN3IN2IN1
GND
L2
L1
6.31
7.50
5.88.22
1.50
4.50
.18
(4 PLACES)
5.31.50
6.19
.66
4.20
3.32 .13
.90
4.506.31
.22
(4 PLACES)
PANEL CUT OUT
(HALF SCALE)
DIMENSIONS #8-32 UNC-2B
5.43
5.88
.36
OPTIONAL 35MM DIN RAIL
MOUNTING HARDWARE
2500CBXXXX
2500 SERIES PLS
SERIAL No. >>>>>> D/C >>>>
Clawson, MI 48017 U.S.A.
R
Figure 2-12: 2500CB Blind Main Controller Dimensions

18
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
6.31
7.50
1.82
2.36
4.50
1.50
5.88.22
6.19
.66
.50 5.31
2500RX
2500 SERIES PLS
SERIAL No. >>>>>> D/C >>>>
Clawson, MI 48017 U.S.A.
NP0197900
R
ENTER
SCROLL
MENU
2500 SERIES PLS
Clawson, MI 48017 U.S.A.
R
.90
4.506.31
.22
(4 PLACES)
PANEL CUT OUT
DIMENSIONS
#8-32 UNC-2B
5.43
5.88
Figure 2-13: 2500R Remote Operator Interface

19
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
w
SDEC
TR5
V
F 4A 250V
V
SC
DE
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
w
TR5
C
V
DE
S
F 4A 250V
DE
SC
V
TR5
w
F 4A 250V
w
C
V
DE
S
TR5
F 4A 250V
C
V
DE
S
TR5
w
F 4A 250V
IN4
INPUT STATUS
IN1 IN2 IN3 IN6IN5 IN7 IN8
INTERNALLY FUSED
L1
100-240 VAC
50/60 Hz
AC POWER
GND
L2
OUT4OUT1 OUT2 OUT3 OUT6OUT5 OUT7 OUT8
6.31 4.50 (HALF SCALE)
5.88
5.43
PANEL CUT OUT
.22
.90
DIMENSIONS #8-32 UNC-2B
(4 PLACES)
3.39
.13
2.51
6.31
7.50 4.50
1.50
6.19
.66
5.88
.22
5.31.50
.18
(4 PLACES)
EXPANSION OUT
.36
OPTIONAL 35MM DIN RAIL
MOUNTING HARDWARE
SERIAL No. >>>>>> D/C >>>>
2500EXXXXX
Clawson, MI 48017 U.S.A.
2500 SERIES PLS
R
Figure 2-14: 2500E Expansion Module

20
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Fax 248.435.8120 • www.AMETEKAPT.com
This section describes the installation
and wiring of the 2500 PLS family.
Changes to these instructions should
be made as necessary if special options
and/or equipment are used.
The 2500 PLS should be installed in an
area free of water spray, corrosive gases,
flying chips or other foreign matter.
The operating temperature should be
between 32 and 125 degrees Fahrenheit,
with less than 95% relative humidity.
3.1 Mechanical Installation
Mounting the 2500 PLS
The 2500 PLS is designed to be panel
or DIN-rail mounted. The face of the
2500 can be affected by water and/or
oil spray. Provisions should be made to
protect the face of the unit from spraying
or splashing.
Panel cutouts, mounting holes and
sizes for each component are shown in
Chapter 2.
The controller should be mounted in the
appropriate panel cutout and securely
bolted into place using the four (4) 3/6”
diameter mounting holes. ADIN-rail
mounting kit is supplied with all blind
main controller units and expansion
modules for an optional means of
mounting. See Fig. 3-1.
NOTE: In instances where the 2500 is
being mounted directly on high vibration
machinery, care should be taken to
isolate the controller from shock load
and vibration.
It is always good design practice to
mount the controller in the enclosure
as far away from the motor starters
and control relays as possible to
minimize the effects of electromagnetic
interference (EMI).
Interconnecting wiring should also be
routed to minimize EMI coupling.
To attach DIN-rail to the Expansion
Module or Blind Main Controller unit,
place the two supplied 8-32 x 5/8” lg.
screws through the DIN-rail bracket and
firmly attach to aluminum plate.
Chapter 3: Mounting and Wiring
This manual suits for next models
3
Table of contents
Popular Switch manuals by other brands

Rose electronics
Rose electronics Vista KM III/A1 Installation and operation manual

Endress+Hauser
Endress+Hauser Liquipoint T FTW31 operating instructions

Sony
Sony BKPF-R70 installation manual

D-Link
D-Link DGS-1008MP Quick installation guide

StarTech.com
StarTech.com SV431HDU3A2 quick start guide

Monoprice
Monoprice 8146 user manual

Multico
Multico EW-K1302DPC4K Quick installation guide

3Com
3Com SUPERSTACK 3 4500 Quick reference guide

PTN
PTN SC51D user manual

Alcatel-Lucent
Alcatel-Lucent 1830 PSS-16 Maintenance and trouble-clearing user guide

Kindermann
Kindermann HDMI Switch 41 automatic 4K60 Commissioning and operating instructions

ANTAIRA
ANTAIRA LNP-0500-24 Series user manual