GENERAL LIFE FH250S User manual

ROOM THERMOSTAT TEMPERATURE CALIBRATION
Temperature sensors used in Room Thermostats are very sensitive.
Based on the temperature on the thermometers in your living space you
need to calibrate your Room Thermostat. For this:
While your device is off, press and hold the button for 3 seconds.
 Press the button until you see the calibration menu that says “ ”
press it. The temperature difference you want from the calibration
menu, Adjust by turning the button to the right or left. This value can
be adjusted between “-8°C” and “+8°C”.
Press the button until the device turns off to save the settings and
exit.
o
Note: Recommended temperature calibration setting is “0.0 C”.
ROOM THERMOSTAT HYSTERESIS POSITIVE MENU
The hysteresis positive factory setting of your Room Thermostat is
0.5°C. This value can be adjusted between “0.1°C” and “2.0°C”. While the
hysteresis positive value is 0.5°C, your Room Thermostat will send a
command to your heating unit when the room temperature rises 0.5°C
above the set temperature. For example, when we set the Room
Thermostat to 22.0°C, your heating unit will stop when the room
temperature rises to 22.5°C. To change the hysteresis positive setting:
While your device is off, press and hold the button for 3 seconds.
“Press the button until the “ ” menu appears.
In the hysteresis positive menu, you can adjust the operating
sensitivity by turning the “ ” button to the right or left.
Press the button until the device turns off to save the settings and
exit.
The settings you have made have been saved. When you turn on your
device, it will work with the operating sensitivity you have set.
ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU
The hysteresis negative factory setting of your Room Thermostat is
-0.5°C. This value can be adjusted between “-0.1°C” and “-2.0°C”. While
the hysteresis negative value is -0.5°C, your Room Thermostat will send a
command to your heating unit when the room temperature drops 0.5°C
below the set temperature. For example, when we set the Room
Thermostat to 22.0°C, your heating unit will work when the room
temperature drops to 21.5°C. To change the hysteresis negative setting:
While your device is off, press and hold the button for 3 seconds.
Press the button until the “ ” menu appears.
In the hysteresis negative menu, you can adjust the operating
sensitivity by turning the “ ” button to the right or left.
Press the button until the device turns off to save the settings and
exit.
The settings you have made have been saved. When you turn on your
device, it will work with the operating sensitivity you have set.
GENERAL SPECIFICATIONS
FH250S is a digital room thermostat designed for underfloor heating
system. User provides more comfortable and affordable heating by
setting needed room temperature.
Sensitive Temperature Measurement Hysteresis Adjustment
Temperature Calibration ON/OFF Control
Wired connection
Floor sensor temperature setting
FH250S AND EQUIPMENTS
TECHNICAL DATA
ROOM THERMOSTAT
* External floor sensor is only active when it is connected.
ROOM THERMOSTAT PLACEMENTPlace your Room Thermostat in a
room you use frequently in your living space. For example; like the hall or
living room of your home. Avoid installing the Room Thermostat in
places where there is a lot of air circulation, such as at the doorway or by
the window. Also, do not place it close to heating units (heater core,
fireplace, etc.) and in direct sunlight. We recommend that the room
thermostat is placed at a height of 150 cm from the floor.
FLOOR SENSOR TEMPERATURE SETTING MENU
If a floor sensor is installed with Room Thermostat, only GENERAL Life
floor sensor should be installed. Otherwise, the product will be out of
warranty.
*In case of floor sensor connected, the following settings apply.
The factory temperature setting for floor sensor is 28°C. This value can
be adjusted between 23°C and 34°C. The floor sensor operating
sensitivity is 1°C. For example, when you set the floor sensor
temperature to 28°C, your Room Thermostat will stop the heating unit
from working when the floor temperature rises to 29°C. When the floor
temperature drops to 27°C, it starts the heating unit of the Room
Thermostat. To change the floor sensor temperature:
Press and hold the button for 3 seconds while your device is off.
Press the button until the “ ” menu appears.
Adjust the operating temperature by turning the “ ” button to the
right or left in the floor sensor temperature menu that appears.
Press the button until the device turns off to save the settings and
exit.
The settings you have made have been saved. When you turn on your
device, it will operate at the floor sensor temperature you have set.
FACTORY RESET
You can reset the Room Thermostat to its factory default settings. This
action resets the calibration setting and hysteresis settings to the
factory setting. To factory reset your Room Thermostat:
While your device is off, press and hold the button for 3 seconds.
Press the button until the “ ” menu appears.
While in the “ ” menu, turn the button to the right or left, select the
“ ” option and press the button.
Your device will turn off and reset to factory settings.
ROOM THERMOSTAT WORKING PRINCIPLE
As soon as you energize your Room Thermostat, it will start working. It is
based on the average temperature of the environment where the Room
Thermostat is located in the last 40 seconds. If the ambient
temperature rises above the hysteresis positive temperature you set,
your Room Thermostat turns off the heating unit, and if it drops below
hysteresis negative temperature value, it turns on the heating unit.
Thus, it is ensured that the ambient temperature remains within a
certain range.
If the floor sensor measures temperature ablove 28°C, it turns off the
heating unit.*
*External floor sensor is only active when it is connected.
1
FH250S Room Thermostat
85.7mm / 85.7mm / 33.5mm
230V AC
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
o
0.1 C
o o
(-2.0 C) – (+2.0 C)
o o
(5 C) – (30 C)
o o
(-10 C) – (+50 C)
o o
(-20 C) – (+60 C)
Dowels and
Screws
Dimensions ( H / L / W )
Operating Current
Relay NO Switching Current
Temperature Measurement
Accuracy
Operating Sensitivity
Operating Temperature Range
Operating Temperature
Storage Temperature
123
FH250S USER MANUAL
ENGLISH
generallife.com.tr
generallife.com.tr
FLOOR HEATING ROOM THERMOSTAT
FH250S
USER MANUAL
150 cm
min. 20 cm
1
23
4
FLOOR HEATING ROOM THERMOSTAT
1
2
3
4
Room Temperature
Underfloor Heating Temperature*
Set Temperature
Heating Indicator
- If the Heating Indicator is blinking, the heating unit is working.
- If the Heating Indicator lights up constantly, the heating unit
is not working.
Time
Heating
Unit Off
Heating
Unit On
Set
Temperature
Room
Temperature
o
22.0 C
o
22.5 C
o
21.5 C
4 7
56
WIRING DIAGRAM of ROOM THERMOSTAT
WARNING!
Operating related to the control panel, heating unit or electrical
installation must be carried out by persons with professional
qualifications.
14
2
36WARNING!
The assembly of product
should be done according to
the image above.
For electrical connection,
please see diagram 5.
5
NTC
L
L1
N
10-Devices and their apparatus are out of warranty if they are beaten,
broken or scratched by the customer.
11-Damages resulting from the use of devices and apparatus
belonging to other brands and models without the approval of the
manufacturer are not covered by the warranty.
12-Battery leakage and errors due to rust, oxidation and liquid contact
by working in acidic / humid environments are not covered by the
warranty.
13-When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that will occur are out
of warranty.
14-Damages that may occur during the transportation of devices and
apparatus are not covered by the warranty. Customers can take a
transportation insurance.
15-Damages caused by mains voltage / faulty electrical installation
are not covered by the warranty.
16-Devices and apparatuses are out of warranty for malfunctions
caused by force majeure such as fire, flood, earthquake etc.
17-All of the devices and apparatuses, including all their parts, are
under the warranty of our company.
18-In case of malfunction of the devices and apparatuses within the
warranty period, the time spent during repairment period is added to
the warranty period. The repair period of the product cannot exceed
20 working days. This period starts from the date of notification to the
service station of the malfunction related to the product or, in the
absence of a service station, to the seller, dealer, agency,
representative, importer or manufacturer of the product. Consumer
can report the problem by; phone, fax, e-mail, registered and reply paid
letter or a similar way. However,in case of a conflict , responsibility of
prove is belong to the customer. If the malfunction of the product is
not repaired within 20 working days, the manufacturer-producer or
importer; has to allocate another product with similar features to the
use of the consumer until the repair of the product is completed.
19-Although the consumer uses his/her repair rights,
-If the product breaks down for 4 times in a year or 6 times in warranty
duration and these problems effects main purpose of the product.
(starting from delivery time during warranty.)
- Exceeding the maximum time required for repair,
- In the event that the service station is not available, if it is determined
that the repair of the defect is not possible with the report prepared (in
order) by one of the seller, dealer, agency, representative, importer or
manufacturer, a refund or a price discount at the rate of defect can be
requested.
20-The customer can make complaints and appeals to consumer
courts or consumer arbitration committees.
21-The warranty document must be kept by the customer during the
warranty period. If the document is lost, a second document will not
be issued. In case of loss, repair and replacement of devices and
apparatus will be made for a fee.
DECLARATION OF CONFORMITY
ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which
Head Office and production site is located on Fatih Mah. 1188
Sk.No:13/A Sarnıç - Gaziemir - İZMİR – TÜRKİYE confirms and
declares that the product marked with CE and its specifications below
is covered by the provisions of the mentioned directive.
Brand
Product Name
Product Type
Compatible Directives:
Electromagnetic Compatibility Regulation 2014/30/EU
(EMC EN 61000-6-3: 2007 + A1: 2011, EN 61000-6-1: 2007)
Low Voltage Directive 2014/35/EU
(LVD EN 60730-2-9:2010, EN 60730-1:2011)
Additional Information: The mentioned product can be used with
boilers with on / off output and compliance with the directives only
covers the product. ISIPARK is not responsible for the entire system's
compliance with the directives. This statement is not valid if changes
are made to the product without our approval.
WARRANTY CONDITIONS
1- The warranty period starts from the invoice date and warranted
against manufacturing defects for 2 years.
2-Devices and apparatus are delivered to the customer in working
condition in our company. On-site commissioning is subject to a
service fee.
3-The repair of the devices and apparatus covered by the warranty is
carried out in our company factory and should send by contracted
transportation company. In on-site services, the transportation and
accommodation expenses of the service personnel belong to the
customer. The shift fee during transportation is added to the service
fee and collected in advance.
4-The maintenance of devices and apparatus is done in our company.
For the maintenance of the devices and apparatus, the round travel
fares belongs to the customer.
5-In case of malfunctioning of the devices and apparatus whose
warranty period continues, it is tested in our company whether the
malfunction is caused by a customer or manufacturer fault, and it is
reported with a report issued by our company.
6-In case of detection of manufacturer-induced errors of devices and
apparatus whose warranty period continues, the customer can
request a replacement or repair of the devices and apparatus at full
expense by the manufacturer, unless it's higher than the product's
price.
7-In the event that the faults of the devices and apparatus whose
warranty period continues are determined as caused by the customer,
all expenses would be belong to the customer.
8-Customers should be aware of damages (if there is any) of product
and warn manufacturer since the day warranty duration starts.If
customer do not warn manufacturer with knowledge of damage,
customer lose the rights of article 6.
9-Malfunctions resulting from the use of devices and apparatus
contrary to the matters stated in the User Manual are not covered by
the warranty.
: GENERAL Life
: FH250S
: Floor Heating Room Thermostat
ISIPARK reserves the rights of changing product specifications and
user manuals.
* For all changes, you may visit generallife.com.tr
Vendor
Title:
Adress:
Tel: Fax:
E-Mail:
Invoice Date and Number:
Delivery Time and Place:
Authorized Signature:
Company Stamp:
Product
Type: Floor Heating Room Thermostat
Brand: GENERAL Life
Model: FH250S
STAMP
V-01.2021
WARRANTY CERTIFICATE
Manufacturer
Title: ISIPARK İÇ DIŞ TİC. A.Ş.
Adress: Fatih Mah. 1188 Sk. No:13/A Sarnıç
Gaziemir İzmir-TÜRKİYE
Tel: +90 (232) 457 99 50
Fax: +90 (232) 457 91 22
E-mail: [email protected]
Authorized Signature:
Company Stamp:
Product
Type: Floor Heating Room Thermostat
Brand: GENERAL Life
Model: FH250S
Warranty Period: 2 Years
Max. Time to Repair: 20 Days
Bandrol and Serial Number:

Other GENERAL LIFE Thermostat manuals

GENERAL LIFE HT120 SET User manual

GENERAL LIFE

GENERAL LIFE HT120 SET User manual

GENERAL LIFE HT300 User manual

GENERAL LIFE

GENERAL LIFE HT300 User manual

GENERAL LIFE SOLARA 330S RF User manual

GENERAL LIFE

GENERAL LIFE SOLARA 330S RF User manual

GENERAL LIFE HT330S User manual

GENERAL LIFE

GENERAL LIFE HT330S User manual

GENERAL LIFE HT250S SET User manual

GENERAL LIFE

GENERAL LIFE HT250S SET User manual

GENERAL LIFE HT250 SET User manual

GENERAL LIFE

GENERAL LIFE HT250 SET User manual

GENERAL LIFE HT100S RF User manual

GENERAL LIFE

GENERAL LIFE HT100S RF User manual

GENERAL LIFE HT300 User manual

GENERAL LIFE

GENERAL LIFE HT300 User manual

GENERAL LIFE ARUNA 302S RF User manual

GENERAL LIFE

GENERAL LIFE ARUNA 302S RF User manual

GENERAL LIFE isipark HT260S User manual

GENERAL LIFE

GENERAL LIFE isipark HT260S User manual

GENERAL LIFE isipark HT250S User manual

GENERAL LIFE

GENERAL LIFE isipark HT250S User manual

GENERAL LIFE Senna 300S User manual

GENERAL LIFE

GENERAL LIFE Senna 300S User manual

GENERAL LIFE HT500 SET User manual

GENERAL LIFE

GENERAL LIFE HT500 SET User manual

GENERAL LIFE MITRA 110S User manual

GENERAL LIFE

GENERAL LIFE MITRA 110S User manual

GENERAL LIFE isipark NORA 270S User manual

GENERAL LIFE

GENERAL LIFE isipark NORA 270S User manual

GENERAL LIFE HT270 SET User manual

GENERAL LIFE

GENERAL LIFE HT270 SET User manual

GENERAL LIFE MITRA 110S User manual

GENERAL LIFE

GENERAL LIFE MITRA 110S User manual

GENERAL LIFE ARUNA 301S User manual

GENERAL LIFE

GENERAL LIFE ARUNA 301S User manual

GENERAL LIFE MITRA 220 RF User manual

GENERAL LIFE

GENERAL LIFE MITRA 220 RF User manual

GENERAL LIFE HT120 SET User manual

GENERAL LIFE

GENERAL LIFE HT120 SET User manual

Popular Thermostat manuals by other brands

Lennox iComfort E30 user guide

Lennox

Lennox iComfort E30 user guide

Frigor Tstat Series manual

Frigor

Frigor Tstat Series manual

Honeywell T498A manual

Honeywell

Honeywell T498A manual

Tempro TP500 operating instructions

Tempro

Tempro TP500 operating instructions

Kermi WFS Instructions for use

Kermi

Kermi WFS Instructions for use

Siemens EcoView installation instructions

Siemens

Siemens EcoView installation instructions

Saswell SAS6000UTK-7 Installation and operation instructions

Saswell

Saswell SAS6000UTK-7 Installation and operation instructions

White Rodgers 1C30(W) installation instructions

White Rodgers

White Rodgers 1C30(W) installation instructions

3M 3M-30 Operation guide

3M

3M 3M-30 Operation guide

Tecnosystemi Showgas Smart Plus user manual

Tecnosystemi

Tecnosystemi Showgas Smart Plus user manual

MIKOTERM mControl HT400 instructions

MIKOTERM

MIKOTERM mControl HT400 instructions

Spyder Robotics Herpstat HP user manual

Spyder Robotics

Spyder Robotics Herpstat HP user manual

Kanmor 501x Data brochure

Kanmor

Kanmor 501x Data brochure

Salus FT100 instruction manual

Salus

Salus FT100 instruction manual

HYSEN HY06RF-BW quick start guide

HYSEN

HYSEN HY06RF-BW quick start guide

Hep2O 52UH873 manual

Hep2O

Hep2O 52UH873 manual

TechniSat HT2 manual

TechniSat

TechniSat HT2 manual

Honeywell Home RCHT9610WFW2004 installation guide

Honeywell Home

Honeywell Home RCHT9610WFW2004 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.