Genie PWIPN4EB User manual

Quick Start Guide
Please read these instructions carefully before operating the unit
and keep for further reference.
4MP H.265 IP IR Eyeball
Camera with 2.8mm Lens
PWIPN4EB

ii
Intro Section
Please read this instruction carefully before operating the product and keep it for further
reference. All examples and pictures used here are for reference only.
The contents of this manual are subject to change without notice.
CAUTION:
• If the product does not work properly, please contact your dealer or the nearest service
centre. Never attempt to disassemble the camera yourself. We shall not be responsible
for any problems caused by unauthorised repair or maintenance.
• Do not allow water or liquid into the camera while in use.
• When using the product, you must be in strict compliance with the electrical safety
regulations of the nation and region.
• When the product is mounted on wall or ceiling, the device needs to be firmly fixed.
• Make sure the power supply voltage is correct before using the camera.
• Do not drop the camera or subject it to any physical shock.
• If cleaning, please use a clean soft cloth with a little neutral detergent to wipe it gently.
• Do not aim the camera at the sun or in any area where there is bright lighting.
• The device may be burned out by a laser beam, so when any laser equipment is in use,
make sure that the surface of the device will not be exposed to the laser beam.
• Do not place the camera in extremely hot, cold , dusty or damp locations, and do not
expose it to high electromagnetic radiation.
• To avoid heat accumulation, good ventilation is required for operating environment.

Contents
iii
1.0 Introduction..........................................................................................................4
1.1 Product Features...........................................................................................4
1.2 Product Dimensions.....................................................................................4
1.3 Contents ......................................................................................................4
1.4 Specification ................................................................................................5
2.0 Overview..............................................................................................................6
3.0 Installation............................................................................................................7
4.0 Network Connection ...........................................................................................8

4
The Genie PWIPN4EB is a 4MP IP IR eyeball camera with a 2.8mm lens. The camera also
features up to 30m IR night view distance as well as being IP67.
1.1 Product Features
• NDAA compliant
• 4MP (2560 × 1440) H.265 coding
• Maximum resolution: 2560 × 1440
• ICR auto switch, true day / night, ROI coding
• 3D DNR, digital WDR, HLC, BLC, defog
• 20~30m IR night view distance
• DC12V / PoE power supply
• 1CH built-in MIC
• IP67 ingress protection
• Supports three streams
• Supports remote monitoring by smart phones and tablet PC’s with iOS and Android OS
• Intelligent analytics : Object removal detection, abnormal video signal detection, line
crossing detection and region intrusion detection
• Onvif compliant
1.2 Product Dimensions
1.3 Contents
1.0 Introduction
Camera Quick Start Guide Tapping Screw x3
CD Drill Template
L-Wrench
Plastic Plug x3
82.8mm
94.6mm

Quick Start Guide 4MP H.265 IP IR Eyeball Camera with 2.8mm Lens
5
1.4 Specification
Camera
Image Sensor 1 / 2.7 “CMOS
Image Size 2560 × 1440
Electronic Shutter 1 / 25 s ~ 1 / 100000 s
Iris Type Fixed Iris
Minimum Illumination 0.011 Lux @ F1.2, AGC ON, 0 Lux with IR,
0.04 Lux @ F2.26, AGC ON, 0 Lux with IR
Lens 2.8 mm @ F2.0, Horizontal field of view: 110°
Lens Mount M12
Wide Dynamic Range Digital WDR
BLC Yes
HLC Yes
Defog Yes
Digital NR 3D DNR
Angle Adjustment Pan: 0°~360°, Tilt: 0°~75°, Rotation: 0°~360°
Image
Video Compression H.265, H.264
H.265 Compression Standard Main Profile @ Level 4.1 High Tier
Resolution 4MP (2560 × 1440), 3MP (2304 × 1296), 1080p (1920 × 1080),
720p (1280 × 720), D1, CIF, 480 × 240
Main Stream 60Hz : 4MP, 3MP, 1080p (1~30fps), 50Hz : 4MP, 3MP, 1080p (1~25fps)
Sub Stream 60Hz : 720p (1~15fps), D1 (1~30fps), CIF (1~30fps),
50Hz: 720p (1~12fps), D1 (1~25fps), CIF (1~25fps)
Bit Rate 64 Kbps ~ 5 Mbps
Bit Rate Type VBR / CBR
Image Settings ROI, Saturation, Brightness, Chroma, Contrast, Wide Dynamic, Sharpen,
NR, etc. Adjustable through client software or web browser
ROI Each ROI to be configured separately
Functions
Remote Monitoring Web browsing, CMS remote control
Online Connection Supports simultaneous monitoring for up to 4 users. Supports multi-
stream real time transmission
Network Protocol UDP, IPv4, IPv6, DHCP, NTP, RTSP, PPPoE, DDNS, SMTP, FTP, 802.1x,
UPnP, HTTP, HTTPs, QoS
Interface Protocol Onvif compatible
Intelligent Analytics Video blur detection, Line crossing detection, Region intrusion
detection
Storage Network remote storage
Smart Alarm Motion detection
General Function Watermark, IP address filtering, video mask, heartbeat, password
protection
PoE Yes
IR Distance 20 ~ 30 m
Interface
Network RJ45
Video Output No
Audio Built-in MIC x1
Storage No
Hardware Reset No
Others
Ingress Protection IP67
Power Supply DC12V (PoE power supply optional)
Power Consumption < 5.5W
Operating Environment - 30 °C ~ 60°C (-22°F~140°F), Humidity: Less than 95% (Non-condensing)
Dimensions 94.6 × 82.8 mm
Weight Approximately 0.45Kg

6
2.0 Overview
Security Cap
DC12V
1. Network Connector
2. Power Connector
3. Mounting Base
4. Fixed Screw
5. Micro SD Card Slot*
6. Reset*
1. Loosen the nut from the main element.
2. Run the network cable (without RJ 45 connector) through both elements. Then crimp
the cable with RJ 45 connector.
3. Connect the cable to the hermetic connector. Then tighten the nut and the main
cover.
Connecting Network Cable
Note: Micro SD card slot and reset are optional. If no such interfaces, please
skip these instructions.
• It is recommended to install the security cap for outdoor installation.
• If the PoE switch is used to power the camera that supports PoE power supply, DC12V
power supply is not required.

7
Please make sure that the wall or ceiling is strong enough to withstand 3 times the weight
of the camera. Please install the camera in and under a dry environment.
1. Loosen the fixed screw to disassemble the camera.
2. Remove the cover from the dome to insert the SD card. Then, install the cover back
to the dome and fix it firmly with the screws. Please note that the cover should not be
installed unevenly. (Please skip this step if your camera has no micro SD card slot).
3. Attach the drill template to the place where you want to fix the camera and then drill
the screw holes and the cable hole on the wall according to the drill template.
4. Route and connect the cables. Then secure the mounting base to the ceiling or wall
with the screws provided.
5. Install the dome and enclosure to the mounting base and then adjust the dome to
obtain an optimum view angle. Finally, fix the camera with the fixed screw.
3.0 Installation
Fixed Screw
Mounting Base
Enclosure
Dome
Cover

8
In LAN, there are two ways to access the camera:
1. Access Through IP-Tool
2. Direct Access Through Web Browser
Access the Camera through the IP Tool
1. Make sure that the camera and the PC are well connected via LAN.
2. Find the IP-Tool from the CD and then install it in the computer. After that, run the IP
Tool as shown below.
3. Modify the IP address. The default IP address of this camera is 192.168.226.201.
Click the information of the camera listed in the above table to show the network
information on the right hand. Modify the IP address and gateway of the camera and
make sure its network address is in the same local network segment as that of the
computer. Please modify the IP address of your device according to the practical
situation.
4. Double-click the camera listed in the IP-Tool or manually enter the IP address in
the address bar of the web browser to connect IP-CAM. Then follow directions to
download and install the plugin. Enter the username and password in the login
interface. The default username is admin; the default password is 123456.
4.0 Network Connection
For example, the IP address of your computer is 192.168.1.4. So the IP address of the
camera shall be changed to 192.168.1.X and the gateway shall be changed to 192.168.1.1.
After modification, please enter the password of the administrator and click “Modify”
button to modify the settings. The default password of the administrator is “123456”.

Quick Start Guide 4MP H.265 IP IR Eyeball Camera with 2.8mm Lens
9
Access the Web Browser
The default network settings are as shown below:
• IP address: 192.168.226.201
• HTTP:80
• Subnet Mask: 255.255.255.0
• Data Port:9008
• Gateway: 192.168.226.1
You may use the above default settings when you log in the camera for the first time.
1. Set the IP address of the PC and make sure the network segment should be as the
same as the default settings of IP-CAM. Open the network and share center. Click
“Local Area Connection” to pop up the following window. Select “Properties” and
then select Internet protocol according to the actual situation (for example: IPv4).
Next, click “Properties” button to set the network of the PC.
2. Open a browser and enter the default address of IP-CAM and confirm.
3. Download and run the plugin in the computer.
4. Enter the default username and password in the login interface to log in.
Table of contents
Other Genie IP Camera manuals
Popular IP Camera manuals by other brands

Foscam
Foscam FI9851P Upgrade guide

Paradox
Paradox HD78 installation manual

Airlink101
Airlink101 AIC250 Quick installation guide

Moxa Technologies
Moxa Technologies VPORT P06-1MP-M12 Quick installation guide

RDS
RDS 720P Weatherproof IR Night vision camera Quick installation guide

StarVedia
StarVedia IC212 user manual