German Light Products Impression XL User manual

Usermanual
from Software Version 1.09/0.3
(Manual Version 1.00)
Internet: http://www.glp.de

For your notes:

R
R
R-
-
-G
G
G-
-
-B
B
B
Table of content
1Description of Device.......................................................................................................... 4
1.1 Safety Instructions ...................................................................................................................... 5
2Preparation and Installation............................................................................................... 6
2.1 Mounting..................................................................................................................................... 6
2.1.1 Mounting on the Floor (Upright).................................................................................. 7
2.1.2 Mounting in hanging Position (Head first) .................................................................. 8
2.1.3 Mounting in sidewise Position .................................................................................... 8
2.2 Secure the Device ...................................................................................................................... 9
2.3 Connections................................................................................................................................ 9
2.3.1 Power Supply.............................................................................................................. 9
2.3.2 DMX............................................................................................................................ 9
3The Menu Field..................................................................................................................10
4DMX Channel Sheet .......................................................................................................... 12
5Maintaining and Cleaning the IMPRESSION................................................................... 17
5 IMPRESSION
5.1 Safety regulations..................................................................................................................... 17
5.2 Circumference and Interval (rule-of-thumb) ............................................................................. 17
6Technical Specifications .................................................................................................. 18
7Index................................................................................................................................... 19
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 3

R
R
R-
-
-G
G
G-
-
-B
B
B
1 Description of Device
1. Moving head (actively and
passively cooled)
2. Arm with various cooling vents
3. LCD-Display/Menu (data entry)
4. Base with various connectors
and Camlock mounting system
ÆSafety eyes
5. DMX- Output (5 Pin)
6. DMX- Output (3 Pin)
7. Micro-fuse 6.3x32mm, T15A
8. Power On/Off
9. 2x Safety eyes
10. Powercon (Mains supply)
11. Empty
12. DMX- Input (3 Pin)
13. DMX- Input (5 in)
Only connect one cable to the DMX-
Out/Input at a time!
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 4

R
R
R-
-
-G
G
G-
-
-B
B
B
1.1 Safety Instructions
The
I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
XL
L
is a High-Tech Product. To guarantee a smooth
operation, it is necessary to respect the following rules.
The manufacturer of this device will not take responsibility of damages
through any disregard of the information in this manual. Warranty claims also
will be cancelled in case the system casing is opened.
1. Make sure before putting the system into operation, that the fan and the air inlets are clean
and not blocked by anything.
2. It must be assured that the system-head can rotate unhindered throughout his complete
rotating range. A safety distance of at least 0.5 m to any easily inflammable material (e.g.
decoration material) must be adhered.
3. Attention! Don’t touch the device during the operation. This can cause injuries or
damages.
4. Only connect one cable to the DMX-Out/Input at a time!
5. Attention! The Tilt-Lock shall only be used to secure the head of the unit during transport
– or during repair of the fixture. Never lift or carry the fixture by holding its head when the
Tilt-Lock is in position. Otherwise the Tilt-Lock may become dysfunctional.
6. The system doesn’t contain any maintainable parts. Don’t open it!
7. It is necessary to wait at least 15 minutes after disconnecting the AC before changing the
optical carrier. Pay attention to possibly hot parts of the system.
-- Danger of BURNING --
8. Never look directly into the beam of light or one of the LEDs. Never use optical
apertures with a distance less than 0.5 m to observe the beam of light. LED Class 2M.
You'll risk a serious injury of your eyes and in particular of your retina.
Attention: LED Class 2M can cause injuries of your eyes even
without optical instruments in front of them or within a distance
of less than 0.5m and short exposure time.
Hence: Avoid direct radiation of your eyes!
9. To allow a secure operation, follow also the Installation guide described in chapter 2.
Operating the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
XL
L
without suitable safety aids like Safety cables or
clamps/hooks can increase the risk of an accident.
10. Repair-, maintenance- and installation work shall be done by qualified or GLP certified staff
only. You need to pay attention to the common rules of technology that are not explicit
mentioned in this manual.
11. Use only original spare parts. Any structural modification on the system will terminate all
warranty claims.
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 5

R
R
R-
-
-G
G
G-
-
-B
B
B
2 Preparation and Installation
2.1 Mounting
The I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
XL
L
is fully operational whether it hangs or is mounted to the wall. It can also
be operated while standing on the floor. Keep a safety distance of 0.5 m towards any easily
inflammable materials (decoration etc.).
Pay attention to the regulations of: BGV C1 (former VBG 70) and DIN VDE
0711-217.
The installation shall be done by qualified staff only.
For the various mounting positions of the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
XL
L(standing on the floor, sideways or
hanging) different accessories kits are available. Through this a safe and firm installation is
assured. You'll find special connectors on the bottom side of the system which are put to use
here. In addition the front side of the system is marked with (FRONT) as this is important for a
even orientation during installation.
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 6

R
R
R-
-
-G
G
G-
-
-B
B
B
2.1.1 Mounting on the Floor (Upright)
To operate the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
Nin an upright position, please use the dedicated tripod
which is mounted to the bottom side of the system. It is fixed with fasteners called
Camlock quick-release connectors. Turn the two fasteners both 90° to lock them. Do
the opposite to release them again. On both sides you'll find eyelets to pull though a
fixing strap. This allows an additional bracing of the system during the upright
operation.
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 7

R
R
R-
-
-G
G
G-
-
-B
B
B
2.1.2 Mounting in hanging Position (Head first)
To operate the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
XL
Lin an hanging position, please use two half-couplers
(clamp) which need to be mounted to the camlock brackets.
2.1.3 Mounting in sidewise Position
To operate the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
Nin a sidewise position, please use an addition mounting
bar. Also this is fixed by two Camlock quick-release connectors. Two half-couplers
(clamps) are now used to mount the system to a standard truss bar. This technique is
necessary to cope with the torque which accrues in this mounting position. In addition it
allows a concentrically position between two truss belts. Never use the "Mounting in
hanging Position" technique described above to fasten the system in the sidewise
position. A safe and sound installation can not be assured in this way. This can also
damage the system base.
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 8

R
R
R-
-
-G
G
G-
-
-B
B
B
Without mounting bar
2.2 Secure the Device
Regardless of the mounting method of the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
you'll have to use a stipulated safety
wire. Therefore you have to pull the safety wire through to two provided holes on the bottom
side of the system and connect it with the truss-support. Pay attention to a safe and proper
fastening. Install a safety wire that can hold at least 10 times the weight of the fixture. Never use
the carrying handles for this purpose.
2.3 Connections
2.3.1 Power Supply
~100-240 Volt AC, 50-60 Hz, earth contact type plug - Powercon
Connected load 1200 VA (W) <=> 14 AT (micro-fuse 5x20mm)
Please see printing on the case for the right electronic supply!
Disconnect from the mains supply for changing the fuse and use only the above
described micro-fuse type.
2.3.2 DMX
USITT DMX-512 Standard input/output in 3 pole and 5 pole connectors.
Pin 1 = [Ground] / Pin 2 = [-] / Pin 3 = [+]
The DMX- Addressing starts at the DMX- Address [001].
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 9

R
R
R-
-
-G
G
G-
-
-B
B
B
3 The Menu Field
You’ll find the control board on the side part of
the arm. It allows you to make all necessary
adjustments of the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N.
.With the
Mode-key you get into the main menu.
Afterwards you can navigate through the menu
with the scrollwheel. Push the Enter-key to
get in the next menu level or to confirm your
settings. Make them and set functions ON/OFF
with the scrollwheel. Confirm and save it with
the Enter-key (the display shows OK). Push
the Mode-key to cancel the entry and go back
to the main menu.
ÅMODE - ENTER Æ
Level1 Level 2 Level 3 Level 4 Remark
DMX Start
Address
001 Define the DMX start address
Special Manual DMX Manual control of all system functions
Pan Manual control for Pan (X-movement)
Speed Movements Speed adjustment for Pan/Tilt movements Æsee
also item below
Pan/Tilt Movements Manual control for Pan/Tilt movement
Special Activate the White- or Full-Power Mode; see also
DMX table
White Temperature Abgleich der Farbtemperatur der Farbe WEIß
Dimmer Manual control for Dimmer
Shutter Manual control for Shutter
Blue Manual control for blue
Green Manual control for green
Red Manual control for red
Color Wheel Manual control for the color wheel
Tilt Manual control for Tilt (Y-movement)
Display
Contrast Adjustment for the Display contrast
Default Set Resetting all functions to original values
Set Dimmer
Frequency Changes PMW frequency between 600Hz and
1200Hz
LED Dimmer
Version Reads out the current LED dimmer (software)
version
Impression
Version Reads out the current CPU software version
ÅDOWN - UP Æ
Adjust Key code
xxxx Use the code for entering the calibration menu
(for authorized persons only)
Ente
r
Mode
Scrollwheel ÆU
p
- & Down
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 10

R
R
R-
-
-G
G
G-
-
-B
B
B
Pan Offset Calibration for Pan-Offset
Tilt Offset Calibration for Tilt-Offset
Clear EEPROM Erase EEPROM memory
Diagnose Diagnose functions
Pos
Feed
Pan
Delta
Internal data and function diagnose
Anz
Ti0-Int-
Err Internal data and function diagnose
PFC
Voltage Show the present PFC voltage
LED
PWM
Vers 1 Shows Dimmer-1-Software Version
LED
PWM
Vers 2 Shows Dimmer-2-Software Version
LED
PWM
Vers 3 Shows Dimmer-3-Software Version
Pos
Feed
Tilt
Delta
Internal data and function diagnose
Temperature
Arm
Indicates the arm temperature
Temperature
Head Indicates the head temperature
PAN/TILT
Motor Power Switches power for Pan/Tilt ON or OFF
(disconnected from power)
PAN/TILT
Silent Mode Reduces maximum speed for Pan/Tilt
DMX Hold
Defines whether the last DMX signal is stored or
the lamp is switched OFF in case of signal
interruption
Position
Feedback Automatically position feedback (correction) for
Pan/Tilt movement
White Adjust Adjustments for a uniform white color (white
balance); only in white-mode
Red Input for red adjustments
Blue Input for blue adjustments
Green Input for green adjustments
ÅDOWN - UP Æ
Set DMX
Image Stores the Scene currently sent to the unit
DMX input
Monitor Indicates the presently received DMX signal per
DMX channel
Pan Instantaneous value for Pan
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 11

R
R
R-
-
-G
G
G-
-
-B
B
B
Speed Movements Speed adjustment for Pan/Tilt movements Æsee
item below
Pan/Tilt Movements Instantaneous value for Pan/Tilt movements
Special Instantaneous value for Special
White Temperature Adjustment of the color temperature for WHITE
Dimmer Instantaneous value for Dimmer
Shutter Instantaneous value for Shutter
Blue Instantaneous value for Blue
Green Instantaneous value for Green
Red Instantaneous value for Red
Color Wheel Instantaneous value for Color Mixing unit
Tilt Instantaneous value for Tilt movement
Live time Indicates the overall operation time of the system
Display Adjust the display
Blackout ON/OFF: Display OFF
Select DMX
Mode Please select the desired DMX Mode
Compressed Only 10 DMX channels are being used if this
Mode is activated
Normal 14 DMX channels are being used if this Mode is
activated
High-
Resolution 13 DMX channels are being used if this Mode is
activated. Dimmer operates at 16 bit.
White
Mode ON/OFF: Adjustments for white-balance are
activated
Reverse
Pan ON/OFF: Invert Pan movements
ÅDOWN - UP Æ
Reverse
Tilt ON/OFF: Invert Tilt movements
Reset RESET and new calibration for all functions
4 DMX Channel Sheet
Normal-Mode 14 DMX channels
Channel Function Time and Value DMX HEX %
1) PAN-
coarse 0 .. 660° 0..255 00..FF 0..100
2) PAN-fine High- Pos ... High- Pos + 2,6° (16 Bit) 0..255 00..FF 0..100
3) Tilt-
coarse 0 .. 300° 0..255 00..FF 0..100
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 12

R
R
R-
-
-G
G
G-
-
-B
B
B
Channel Function Time and Value DMX HEX %
4) Tilt-fine High- Pos … High- Pos + 1,2° (16 Bit) 0..255 00..FF 0..100
5) Color Colors adjustable via RGB 0..7 00..07 0..2,5
(fixed) Color 01 - Red 1) 8..15 08..0F 3..5,5
Color 02 - Amber 1) 16..23 10..17 6..8,5
Color 03 - Warm Yellow 1) 24..31 18..1F 9..12,5
Color 04 - Yellow 1) 32..39 20..27 13..15,5
Color 05 - Green 1) 40..47 28..2F 16..18,5
Color 06 - Turquoise 1) 48..55 30..37 19..21,5
Color 07 - Cyan 1) 56..63 38..3F 22..24,5
Color 08 - Blue 1) 64..71 40..47 25..27,5
Color 09 - Lavender 1) 72..79 48..4F 28..30,5
Color 10 - Mauve 1) 80..87 50..57 31..34,5
Color 11 - Magenta 1) 88..95 58..5F 35..37,5
Color 12 - Pink 1) 96..103 60..67 38..40,5
White - CTO Color temperature
3200K
104..111 68..6F 41..43,5
White Color temperature
5600K
112..119 70..77 44..46,5
White - CTB Color temperature
7200K
120..127 78..7F 47..49,5
Rainbow Effect Stop 2) 128 80 50
Rainbow Effect
3) slow - fast 129..223 81..DF 51..88
Rainbow Effect, random colors slow - fast 224.255 E=..FF 89..100
6) Red Color mixing system - Red 0 - 100% 0..255 00..FF 0..100
7) Green Color mixing system - Green 0 - 100% 0..255 00..FF 0..100
8) Blue Color mixing system - Blue 0 - 100% 0..255 00..FF 0..100
9) Shutter Shutter closed 0..15 00..0F 0..5,5
Random Pulse effect slow - fast 16..47 10..2F 6..18,5
Up-dimming then Shutter closing
(random patterns)
slow - fast 48..79 30..4F 19..31
Shutter open then down-dimming
(random patterns)
slow - fast 80..111 50..6F 32..43
Up-dimming then down-dimming
(random patterns)
slow - fast 112..143 70..8F 44..56
Strobe effect pause 5s to 1s 144..199 A0..C7 57..77
Strobe effect, slow - fast 1 Hz .. 10 Hz 200..239 C8..EF 78..94
Shutter open 240..255 F0..FF 95..100
10) Dimmer Dimmer 0% - 100% 0..255 0..FF 0..100
11) Color No color temperature correction 0 0 0
temperature Continuous color temperature
correction between 3200k - 7200k
Applicable only for
White color 5) 1..255 1..FF 1..100
12) Special Max. Power-Mode 4) Max. light output without
white balance
0..15 0..0F 0..5,5
White-Mode 4) White balance used 16..31 10..1F 6..12,5
Fan min. as long as temp. < 60°C 224..229 E0..E5 88..89,5
RESET (Normal Mode) 250..255 FA..FF 98..100
13) Move- No movement 0 00 0
ment Movement Size Phase
PAN 1 0° 01..01 01..01 0,5
1 90° 02..03 02..03 1,0
1 180° 04..05 04..05 1,7
1 270° 06..07 06..07 2,5
PAN 2 0° 08..09 08..09 3,3
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 13

R
R
R-
-
-G
G
G-
-
-B
B
B
Channel Function Time and Value DMX HEX %
2 90° 10..11 0A..0B 4,1
2 180° 12..13 0C..0D 4,9
2 270° 14..15 0E..0F 5,7
PAN 3 0° 16..17 11..11 6,5
3 90° 18..19 12..13 7,3
3 180° 20..21 14..15 8,0
3 270° 22..23 16..17 8,8
PAN 4 0° 24..25 18..19 9,6
4 90° 26..27 1A..1B 10,4
4 180° 28..29 1C..1D 11,2
4 270° 30..31 1E..1F 12
TILT size / phase see also PAN 32..63 20..3F 13..25
PAN / TILT size / phase see also PAN 64..95 40..5F 26..37
PAN / TILT (inverse) size / phase see also PAN 96..127 60..7F 38..50
Circle size / phase see also PAN 128..159 80..9F 51..62
Circle (inverse) size / phase see also PAN 160..191 A0..BF 63..75
Lying eight size / phase see also PAN 192..223 C0..DF 76..87
Random movement size see also PAN 224..255 E0..FF 88..100
14) Speed Pan/Tilt relative movement 0..15 00..0F 0..6
Pan/Tilt Pan/Tilt slow – fast
Use this channel 14) also for the speed
of the movements (channel 13).
Pan Min. 660° = 200s
Pan Max. 660°
Tilt Min. 300° = 110s
Tilt Max. 300°
16..255 10..FF 7..100
4) Max. Power-Mode vs. White-Mode
The I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
XL
Lcan regard the white-balance adjustments for each individual color setting.
Whether the White-Mode is used with RGB can be selected in the Normal DMX-Mode during
operation with the Special DMX channel. If the Special channel is set to a value between DMX 0..15,
the White-Mode is not used and the RGB goes for the maximum light output. If the Special channel is
set to a value between DMX 16..31, the white balance is used for the RGB output.
Since there is no Special DMX channel in the Compress DMX-Mode, the possibility exists to likewise
select these settings also in the display menu. Is the White-Mode set to “ON”, the white-balance is
activated. If the White-Mode is set to “OFF”, the RGB goes for the maximum light output (Max. Power-
Mode).
5) The continuous color temperature correction is applicable only for the White color i.e. if this function
is selected (DMX ≥001) the I
Im
mp
pr
re
es
ss
si
io
on
n
X
XL
Lwill change the color to white immediately and will then
be adjustable in the color temperature in a range between 3200K and 7200K. Hence a color correction
for others than white is not intended.
Compress-Mode 10 DMX channels
Channel Function Time and Value DMX HEX %
1) PAN-
coarse 0 .. 660° 0..255 00..FF 0..100
2) PAN-fine High- Pos ... High- Pos + 2,6° (16 Bit) 0..255 00..FF 0..100
3) Tilt- 0 .. 300° 0..255 00..FF 0..100
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 14

R
R
R-
-
-G
G
G-
-
-B
B
B
Channel Function Time and Value DMX HEX %
coarse
4) Tilt-fine High- Pos … High- Pos + 1,2° (16 Bit) 0..255 00..FF 0..100
5) Color Colors adjustable via RGB 0..7 00..07 0..2,5
(fixed) Color 01 - Red 1) 8..15 08..0F 3..5,5
Color 02 - Amber 1) 16..23 10..17 6..8,5
Color 03 - Warm Yellow 1) 24..31 18..1F 9..12,5
Color 04 - Yellow 1) 32..39 20..27 13..15,5
Color 05 - Green 1) 40..47 28..2F 16..18,5
Color 06 - Turquoise 1) 48..55 30..37 19..21,5
Color 07 - Cyan 1) 56..63 38..3F 22..24,5
Color 08 - Blue 1) 64..71 40..47 25..27,5
Color 09 - Lavender 1) 72..79 48..4F 28..30,5
Color 10 - Mauve 1) 80..87 50..57 31..34,5
Color 11 - Magenta 1) 88..95 58..5F 35..37,5
Color 12 - Pink 1) 96..103 60..67 38..40,5
White - CTO Color temperature
3200K
104..111 68..6F 41..43,5
White Color temperature
5600K
112..119 70..77 44..46,5
White - CTB Color temperature
7200K
120..127 78..7F 47..49,5
Rainbow Effect Stop 2) 128 80 50
Rainbow Effect
3) slow - fast 129..223 81..DF 51..88
Rainbow Effect, random colors slow - fast 224.255 E=..FF 89..100
6) Red Color mixing system - Red 0 - 100% 0..255 00..FF 0..100
7) Green Color mixing system - Green 0 - 100% 0..255 00..FF 0..100
8) Blue Color mixing system - Blue 0 - 100% 0..255 00..FF 0..100
9) Shutter Shutter closed 0..15 00..0F 0..5,5
Random Pulse effect slow - fast 16..47 10..2F 6..18,5
Up-dimming then Shutter closing
(random patterns)
slow - fast 48..79 30..4F 19..31,5
Shutter open then down-dimming
(random patterns)
slow - fast 80..111 50..6F 32..43
Up-dimming then down-dimming
(random patterns)
slow - fast 112..143 70..8F 44..56
Strobe effect pause 5s to 1s 144..199 A0..C7 57..77
Strobe effect, slow - fast 1 Hz .. 10 Hz 200..239 C8..EF 78..94
Shutter open 240...249 F0..F9 95..97,5
RESET Min. 3 Sec. 250 FA 98
Shutter open 251..255 FB..FF 99..100
10) Dimmer Dimmer (0% - 100%) 0..255 0..FF 0..100
High Resolution (Extended) -Mode 13 DMX Channels
Channel Function Time and Value DMX HEX %
1) PAN-
coarse 0 .. 660° 0..255 00..FF 0..100
2) PAN-fine High- Pos ... High- Pos + 2,6° (16 Bit) 0..255 00..FF 0..100
3) Tilt-
coarse 0 .. 300° 0..255 00..FF 0..100
4) Tilt-fine High- Pos … High- Pos + 1,2° (16 Bit) 0..255 00..FF 0..100
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 15

R
R
R-
-
-G
G
G-
-
-B
B
B
Channel Function Time and Value DMX HEX %
5) Red-
coarse Color mixing system – Red 0 - 100% 0..255 00..FF 0..100
6) Red-fine Color mixing system – Red-Low 0..255 00..FF 0..100
7) Green-
coarse Color mixing system – Green 0 - 100% 0..255 00..FF 0..100
8) Green-
fine Color mixing system – Green-Low 0..255 00..FF 0..100
9) Blue-
coarse Color mixing system – Blue 0 - 100% 0..255 00..FF 0..100
10) Blue-fine Color mixing system – Blue-Low 0..255 00..FF 0..100
11) Shutter Shutter closed 0..15 00..0F 0..5,5
Random Pulse effect slow - fast 16..47 10..2F 6..18,5
Up-dimming then Shutter closing
(random patterns)
slow - fast 48..79 30..4F 19..31,5
Shutter open then down-dimming
(random patterns)
slow - fast 80..111 50..6F 32..43
Up-dimming then down-dimming
(random patterns)
slow - fast 112..143 70..8F 44..56
Strobe effect pause 5s to 1s 144..199 A0..C7 57..77
Strobe effect, slow - fast 1 Hz .. 10 Hz 200..239 C8..EF 78..94
Shutter open 240...249 F0..F9 95..97,5
RESET Min. 3 Sec. 250 FA 98
Shutter open 251..255 FB..FF 99..100
12) Dimmer-
coarse Dimmer 0% - 100% 0..255 0..FF 0..100
13) Dimmer-
fine Dimmer - Low 0..255 0..FF 0..100
1) The predefined colors can be used as start-colors for the Rainbow effect. Please select first a
desired start-color before you activate the rainbow effect. All I
Im
mp
pr
re
es
ss
si
io
on
n
X
XL
Ls
swill afterwards start
from that color and will execute the rainbow effect synchronously. Different I
Im
mp
pr
re
es
ss
si
io
on
n
X
XL
Ls
scan
certainly have different start-colors but will still execute the rainbow effect synchronously. If you
choose a color different from the once marked with 1) in the tables above the rainbow start-color will be
red.
2) Rainbow-effect Stop will pause this function. After resuming the rainbow-effect will be continued with
the current color.
3) The Rainbow-effect will run synchronously only if it will be started going out from one of the
predefined colors (see also 1) before).
Additional Display Indication
As a default you'll find the following additional information in the first row of the LCD display:
XX/X/XX
06 = 600Hz / 12 = 1200Hz
N = Normal Mode / C = Compressed Mode / H = High Res. Mode
N = Tilt normal / I = Tilt inverted
N = Pan normal / I = Pan inverted
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 16

R
R
R-
-
-G
G
G-
-
-B
B
B
5
5
Maintaining and Cleaning the I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
The I
IM
MP
PR
RE
ES
SS
SI
IO
ON
N
X
XL
Lis a system of very low maintenance. It is only necessary to clean the air in-
and outlets as well as the optical LED lenses from time to time. For a safe operation it is absolutely
essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not built up on
or within the fixture. Otherwise the fixture's light-output will be significantly reduced or damages can
occur. Regular cleaning will not only ensure the maximum light-output, but will also allow the fixture to
operate reliably throughout its life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no
circumstances should alcohol or solvents be used!
5.1 Safety regulations
•Pull out the main plug!
•Wait min. 15 minutes after the last operation to cool down the fixture.
5.2 Circumference and Interval (rule-of-thumb)
The contamination of the fixture depends on the environment details. Hence no general
guidelines can be given. The intervals given below are only suggestions from our practice
experience.
Position Interval In this way
LED reflector and optical system weekly soft brush /lint-free cloth
Fan and air channel monthly vacuum cleaner, airbrush, etc.
Attention:
•Never let optical parts come into contact with oil or fat.
•Before running the fixture wait until all parts are dried up.
•Never tough lenses with bare fingers.
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 17

R
R
R-
-
-G
G
G-
-
-B
B
B
6 Technical Specifications
Power supply
Power consumption 1200 VA (Watt)
Power Input ~100-240 V AC, 50-60 Hz (wide range input)
Fuse protection Micro-fuse 5x20 mm, T 14A
Operational Parameters
Max. Ambient
Temperature 45°C (integrated overheating switch)
Mounting Position Any (see chapter mounting)
Lighting System - Additive Color mixing
LED Type 240x Luxeon K2 High-power- LEDs
Lifetime 100.000 h
78 red, 84 green, 78 blue LEDs, wavelength optimized for maximum presentable color space.
Optical System
High efficient Collimator cluster
Exchangeable optical carrier with 10° light distribution angle (25° optional)
Scattering light aperture
Shutter / Dimmer (8 Bit)
Strobe- Effect with variable speed between 1 - 10 flashes per second, Random-Strobe, Pulse-Effects
Continuous Dimmer 0 - 100%
DMX Control
Standard USITT DMX-512, 3/5 pole XLR; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.
DMX- Addressing starts at the DMX channel [001].
Pan / Tilt (8/16 Bit)
Pan- movement 660° (Position Feedback)
Tilt- movement 300° (Position Feedback)
Weights and Measures
Width of the base 550 mm
Length of the base 200 mm
Height (head vertical) 515 mm
Fixture weight (net) 23,5 kg
Floor Mount weight (net) 2 kg
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 18

R
R
R-
-
-G
G
G-
-
-B
B
B
7 Index
A
Anleitung Version ............................................1
B
BGV C1............................................................6
C
Camlock...........................................................7
Circumference ...............................................17
Cleaning.........................................................17
Compress-Mode ....................................14, 15
D
Danger of BURNING......................................5
DIN VDE 0711-217..........................................6
DMX.................................................................9
E
e-mail...............................................................1
Enter-key.......................................................10
Eyelets .............................................................7
H
Half-couplers (clamps).....................................8
I
Internet.............................................................1
L
LED Class 2M.................................................5
M
Maintenance ..................................................17
Max. Power-Mode........................................14
Menu Field.....................................................10
Micro-fuse........................................................9
Mode-key.......................................................10
Mounting........................................................ 5
Mounting in hanging Position.......................... 8
Mounting in sidewise Position......................... 8
Mounting on the Floor..................................... 7
N
Normal-Mode............................................... 12
O
Optical parts................................................ 17
P
Pan- Movement............................................. 18
Power Supply................................................ 9
S
Safety distance ............................................... 5
Safety Instructions .......................................... 5
Secure the Device......................................... 9
Software Version............................................. 1
T
Technical Specifications............................ 18
Tilt- Movement .............................................. 18
U
Up/Down-keys.............................................. 10
V
VBG 70 ........................................................... 6
W
Warranty claims .............................................. 5
Weights and Measures ................................. 18
White-Mode.................................................. 14
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 19

R
R
R-
-
-G
G
G-
-
-B
B
B
GLP German Light Products GmbH (Manual Version 1. / from Software Version 1.09/0.3) 20
Table of contents
Other German Light Products Dj Equipment manuals

German Light Products
German Light Products Impression X4 BAR 10 Operating manual

German Light Products
German Light Products JDC1 User manual

German Light Products
German Light Products KNV User manual

German Light Products
German Light Products GT-1 User manual

German Light Products
German Light Products X4 atom free connect User manual

German Light Products
German Light Products GT-1 User manual